Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 88(7): 1167-1175, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38522901

RESUMO

BACKGROUND: The prevalence of transthyretin amyloid cardiomyopathy (ATTR-CM) in atrial fibrillation (AF) patients remains unclear. We explored the efficacy of computed tomography-based myocardial extracellular volume (CT-ECV) combined with red flags for the early screening of concealed ATTR-CM in AF patients undergoing catheter ablation.Methods and Results: Patients referred for AF ablation at Oita University Hospital were prescreened using the red-flag signs defined by echocardiographic or electrocardiographic findings, medical history, symptoms, and blood biochemical findings. Myocardial CT-ECV was quantified in red flag-positive patients using routine pre-AF ablation planning cardiac CT with the addition of delayed-phase cardiac CT scans. Patients with high (>35%) ECV were evaluated using technetium pyrophosphate (99 mTc-PYP) scintigraphy. A cardiac biopsy was performed during the planned AF ablation procedure if 99 mTc-PYP scintigraphy was positive. Between June 2022 and June 2023, 342 patients were referred for AF ablation. Sixty-seven (19.6%) patients had at least one of the red-flag signs. Myocardial CT-ECV was evaluated in 57 patients because of contraindications to contrast media, revealing that 16 patients had high CT-ECV. Of these, 6 patients showed a positive 99 mTc-PYP study, and 6 patients were subsequently diagnosed with wild-type ATTR-CM via cardiac biopsy and genetic testing. CONCLUSIONS: CT-ECV combined with red flags could contribute to the systematic early screening of concealed ATTR-CM in AF patients undergoing catheter ablation.


Assuntos
Neuropatias Amiloides Familiares , Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Miocárdio , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/cirurgia , Cardiomiopatias/diagnóstico por imagem , Miocárdio/patologia , Tomografia Computadorizada por Raios X , Diagnóstico Precoce
2.
Clin Chim Acta ; 511: 298-305, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33096031

RESUMO

BACKGROUND AND AIMS: Polymerase chain reaction-based techniques require expensive equipment for fluorescence detection of the products. However, the measurement of inorganic pyrophosphate (PPi) released during DNA synthesis can be used to quantify target genes without such equipment. Here, we devised a high-sensitivity enzymatic assay for detection of PPi. MATERIALS AND METHODS: In our assay method, PPi was converted to hypoxanthine by hypoxanthine phosphoribosyl transferase. Xanthine dehydrogenase converted the hypoxanthine to uric acid and yielded two molecules of NADH, which in turn reduced Fe3+ to Fe2+ (mediated by 1-methoxy-5-ethylphenazinium ethylsulfate). 2-Nitroso-5-(N-propyl-N-sulfopropylamino) phenol chelated the Fe2+, which resulted in an intensely colored product that could be measured using a biochemical automated analyzer. RESULTS: The assay was able to detect PPi within 10 min. It was linear between 0 and 10 µmol/L PPi, and intra-run and inter-run coefficients of variation were 1%-2%. Other validation tests with a biochemical automated analyzer were satisfactory. The assay could potentially be used to directly quantify samples after isothermal nucleic acid sequence-based amplification of a target gene. CONCLUSION: The method developed here for detection of PPi can be used to measure nucleic acid biomarkers in biological samples in clinical practice using a high-throughput biochemical automated analyzer.


Assuntos
Difosfatos , Replicação de Sequência Autossustentável , Humanos , Técnicas de Amplificação de Ácido Nucleico , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA