Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Water Health ; 17(1): 113-123, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30758308

RESUMO

Ultraviolet disinfection (UVD) units enhance onsite sewage systems (OSSs) in areas where conventional treatment is limited by site characteristics. Although UVD units are efficacious under testing conditions, few studies have considered their effectiveness when installed. This study used a mixed-methods approach to examine UVD unit effluent quality and determine the association between UV bulb status and fecal coliform levels. Samples from UVD units and pump chambers were tested for bacterial and physiochemical parameters. Field data were supplemented with data from retrospective compliance samples. A multivariate Tobit regression model predicted that the geometric mean (GM) fecal coliform concentration was 122% higher when the UV bulb was deficient than when it was not deficient, adjusted for other OSS deficiencies (95% CI: 36-428, p-value <0.001). The predicted GM fecal coliform concentration in malfunctioning UVD unit effluent (745 CFU/100 mL) exceeded field compliance standards (400 CFU/100 mL), and the odds of exceedance were 7.48 times higher when the UV bulb was deficient, adjusted for other OSS deficiencies (95% CI: 4.03-13.9, p-value <0.001). Despite limitations in the characterization of UV dose, the results validate the importance of UVD units to reduce bacterial loads and the need for further research into their field effectiveness.


Assuntos
Desinfecção , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/microbiologia , Enterobacteriaceae , Fezes , Estudos Retrospectivos , Esgotos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA