Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Anal Toxicol ; 46(9): 1025-1031, 2023 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-34922356

RESUMO

Oxycodone (OC) is a schedule II semisynthetic opioid in the USA that is prescribed for its analgesic effects and has a high potential for abuse. Prescriptions for OC vary based on the dosage and formulation, immediate release (IR) and controlled release (CR). Monitoring OC metabolites is beneficial for forensic casework. The limited studies that involve pharmacokinetics of the urinary excretion of OC metabolites leave a knowledge gap regarding the excretion of conjugated and minor metabolites, pharmacokinetic differences by formulation, and the impact of CYP2D6 activity on the metabolism and excretion of OC. The objectives of this study were to compare urinary excretion of phase I and II metabolites by formulation and investigate if ratio changes over time could be used to predict the time of intake. Subjects (n = 7) received a single 10 mg IR tablet of Oxycodone Actavis. A few weeks later the same subjects received a single 10 mg CR tablet of Oxycodone Actavis. During each setting, urine was collected at 0, 0.5, 1, 1.5, 2, 3, 4, 5, 6, 8, 9, 10, 12, 14, 24, 48 and 72 h. Urine samples (100 µL) were diluted with 900 µL internal standard mixture and analyzed on an Acquity UPLC® I-class coupled to a Waters Xevo TQD using a previously validated method. The CYP2D6 phenotypes were categorized as poor metabolizers (PM), intermediate metabolizers (IM), extensive metabolizers (EM) and ultrarapid metabolizers (UM). Comparisons between IR and CR were performed using two-tailed paired t-test at a significance level of P = 0.05. The metabolite ratios showed a general increase over time. Four metabolite to parent ratios were used to predict the time of intake showing that predictions were best at the early time points.


Assuntos
Analgésicos Opioides , Oxicodona , Analgésicos Opioides/farmacocinética , Analgésicos Opioides/urina , Cromatografia Líquida , Citocromo P-450 CYP2D6/genética , Preparações de Ação Retardada , Oxicodona/farmacocinética , Oxicodona/urina , Espectrometria de Massas em Tandem , Humanos
2.
Molecules ; 27(7)2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35408749

RESUMO

The importance of the dynamic interplay between the opioid and the serotonin neuromodulatory systems in chronic pain is well recognized. In this study, we investigated whether these two signalling pathways can be integrated at the single-cell level via direct interactions between the mu-opioid (MOP) and the serotonin 1A (5-HT1A) receptors. Using fluorescence cross-correlation spectroscopy (FCCS), a quantitative method with single-molecule sensitivity, we characterized in live cells MOP and 5-HT1A interactions and the effects of prolonged (18 h) exposure to selected non-peptide opioids: morphine, codeine, oxycodone and fentanyl, on the extent of these interactions. The results indicate that in the plasma membrane, MOP and 5-HT1A receptors form heterodimers that are characterized with an apparent dissociation constant Kdapp = (440 ± 70) nM). Prolonged exposure to all non-peptide opioids tested facilitated MOP and 5-HT1A heterodimerization and stabilized the heterodimer complexes, albeit to a different extent: Kd, Fentanylapp = (80 ± 70) nM), Kd,Morphineapp = (200 ± 70) nM, Kd, Codeineapp = (100 ± 70) nM and Kd, Oxycodoneapp = (200 ± 70) nM. The non-peptide opioids differed also in the extent to which they affected the mitogen-activated protein kinases (MAPKs) p38 and the extracellular signal-regulated kinase (Erk1/2), with morphine, codeine and fentanyl activating both pathways, whereas oxycodone activated p38 but not ERK1/2. Acute stimulation with different non-peptide opioids differently affected the intracellular Ca2+ levels and signalling dynamics. Hypothetically, targeting MOP−5-HT1A heterodimer formation could become a new strategy to counteract opioid induced hyperalgesia and help to preserve the analgesic effects of opioids in chronic pain.


Assuntos
Analgésicos Opioides , Dor Crônica , Receptores Opioides mu , Analgésicos Opioides/farmacologia , Codeína , Fentanila/farmacologia , Humanos , Sistema de Sinalização das MAP Quinases , Morfina/farmacologia , Oxicodona , Receptor 5-HT1A de Serotonina/metabolismo , Receptores Opioides mu/metabolismo
3.
Metabolites ; 12(2)2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35208184

RESUMO

Postmortem metabolomics has recently been suggested as a potential tool for discovering new biological markers able to assist in death investigations. Interpretation of oxycodone concentrations in postmortem cases is complicated, as oxycodone tolerance leads to overlapping concentrations for oxycodone intoxications versus non-intoxications. The primary aim of this study was to use postmortem metabolomics to identify potential endogenous biomarkers that discriminate between oxycodone-related intoxications and non-intoxications. Ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry data from 934 postmortem femoral blood samples, including oxycodone intoxications and controls positive and negative for oxycodone, were used in this study. Data were processed and evaluated with XCMS and SIMCA. A clear trend in group separation was observed between intoxications and controls, with a model sensitivity and specificity of 80% and 76%. Approximately halved levels of short-, medium-, and long-chain acylcarnitines were observed for oxycodone intoxications in comparison with controls (p < 0.001). These biochemical changes seem to relate to the toxicological effects of oxycodone and potentially acylcarnitines constituting a biologically relevant biomarker for opioid poisonings. More studies are needed in order to elucidate the potential of acylcarnitines as biomarker for oxycodone toxicity and their relation to CNS-depressant effects.

4.
Eur J Drug Metab Pharmacokinet ; 47(2): 259-270, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35025054

RESUMO

BACKGROUND AND OBJECTIVES: Oxycodone is frequently prescribed as well as detected in postmortem cases. Concurrent use of pharmacodynamically or pharmacokinetically interacting drugs can cause adverse effects or even fatal intoxication. The aims of this study were to investigate differences in prescriptions for and toxicological findings of pharmacodynamically and pharmacokinetically interacting drugs in fatal oxycodone-related intoxications and other causes of death. We also aimed to investigate the differences in prevalence of oxycodone prescriptions, and the detected postmortem oxycodone concentrations between fatal oxycodone-related intoxications and other causes of death. METHODS: Forensic autopsy cases (2012-2018) where oxycodone was identified in femoral blood (n = 1236) were included. Medical history and prescription data were retrieved from national databases and linked to the forensic toxicology findings. RESULTS: Oxycodone-related deaths were found to have higher blood concentrations of oxycodone (median 0.30 µg/g vs. 0.05 µg/g) and were less likely to have a prescription for oxycodone (OR 0.62) compared to nonintoxication deaths. Pharmacodynamically interacting drugs were prescribed in 79% and found in blood in 81% of the cases. Pharmacokinetically interacting drugs were rarely prescribed (1%). Oxycodone-related deaths were more likely to have prescriptions for a pharmacodynamically interacting drug (OR 1.7) and more often have co-findings of one or multiple pharmacodynamically interacting drugs (OR 5.6). CONCLUSION: The results suggest that combined use of oxycodone and pharmacodynamically interacting drugs is associated with oxycodone-related death and that non-medical use of oxycodone is a potential risk factor for oxycodone-related intoxication.


Assuntos
Analgésicos Opioides , Oxicodona , Analgésicos Opioides/efeitos adversos , Bases de Dados Factuais , Interações Medicamentosas , Toxicologia Forense , Oxicodona/efeitos adversos , Fatores de Risco
5.
J Anal Toxicol ; 46(1): 55-63, 2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-33270113

RESUMO

The purpose of this research was to develop and validate an analytical method for the detection and quantification of noroxymorphone-3ß-D-glucuronide (NOMG), oxymorphone-3ß-D-glucuronide (NOMG), noroxymorphone (NOM), oxymorphone (OM), 6α-oxycodol (αOCL), 6ß-oxycodol (ßOCL), noroxycodone (NOC) and oxycodone (OC) in urine by liquid chromatography tandem mass spectrometry to be used in a human study. The method was validated according to the Academy Standards Board Standard Practices for Method Development in Forensic Toxicology. The method was then applied to a single-dose pilot study of a subject. Urine samples were collected from the subject after ingesting 10-mg OC as an immediate-release tablet. Additionally, urine specimens (n = 15) that had previously been confirmed positive for OC were analyzed using the validated method. The calibration range for NOMG and OMG was 0.05-10 µg/mL; for all other analytes, it was 0.015-10 µg/mL. Validation parameters such as bias, precision, carryover and dilution integrity, all met the validation criteria. After the method was validated, urine samples from the first subject in the controlled dose study were analyzed. It was observed that OC, NOC and OMG contained the highest concentrations and were present in either the 0.5 or 1 h void. NOC and OMG were detected until the 48 h collection, while OC was detectable till the 24 h collection. Time to reach maximum concentration (Tmax) in the urine was achieved within 1.5 h for OC and within 3 h for NOC and OMG. Maximum concentration (Cmax) in the urine for OC, NOC and OMG was 3.15, 2.0 and 1.56 µg/mg, respectively. OC concentrations in authentic urines ranged from 0.015 to 12 µg/mL. Ranges for NOMG and OMG were 0.054-9.7 µg/mL and 0.14-67 µg/mL, respectively. A comprehensive method for the quantification of NOMG, OMG, NOM, OM, αOCL, ßOCL, NOC and OC in urine was optimized and met the validation criteria. The concentrations of NOMG and OMG presented in this study provide the details needed in the forensic community to better comprehend OC pharmacokinetics.


Assuntos
Oxicodona , Espectrometria de Massas em Tandem , Cromatografia Líquida , Humanos , Oximorfona , Projetos Piloto
6.
Forensic Sci Int Genet ; 53: 102510, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33799050

RESUMO

Genetic disposition can cause variation in oxycodone pharmacokinetic characteristics and decrease or increase the expected clinical response. In forensic medicine, determination of cause of death or assessing time between drug intake and death can be facilitated by knowledge of parent and metabolite concentrations. In this study, the aim was to investigate if CYP2D6 genotyping can facilitate interpretation by investigating the frequency of the four CYP2D6 phenotypes, poor metabolizer, intermediate metabolizer, extensive metabolizer, and ultra-rapid metabolizer in postmortem cases, and to study if the CYP2D6 activity was associated with a certain cause of death, concentration, or metabolic ratio. Cases positive for oxycodone in femoral blood (n = 174) were genotyped by pyrosequencing for CYP2D6*3, *4, and *6 and concentrations of oxycodone, noroxycodone, oxymorphone, and noroxymorphone were determined by LC-MS/MS (LLOQ 0.005 µg/g). Digital droplet PCR was used to determine the copy number variation for CYP2D6*5. Cases were categorized by cause of death. It was found that poor and intermediate CYP2D6 metabolizers had significantly higher oxycodone and noroxycodone concentrations compared to extensive and ultra-rapid metabolizers. CYP2D6 phenotype were equally distributed between cause of death groups, showing that no phenotype was overrepresented in any of the cause of death groups. We also found that the concentration ratio between oxymorphone and oxycodone depended on the CYP2D6 activity when death was unrelated to intoxication. In general, a low metabolite to parent ratio indicate an acute intake. By using receiver operating characteristic (ROC) analysis, we conclude that an oxymorphone/oxycodone ratio lower than 0.075 has a high sensitivity for separating intoxications with oxycodone from other intoxications and non-intoxications. However, the phenotype needs to be known to reach a high specificity. Therefore, the ratio should not be used as a biomarker on its own to distinguish between different causes of death but needs to be complemented by genotyping.


Assuntos
Analgésicos Opioides/sangue , Citocromo P-450 CYP2D6/genética , Oxicodona/sangue , Testes Farmacogenômicos , Adolescente , Adulto , Idoso , Analgésicos Opioides/farmacocinética , Variações do Número de Cópias de DNA , Feminino , Genética Forense , Genótipo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Morfinanos/sangue , Oxicodona/farmacocinética , Fenótipo , Polimorfismo de Nucleotídeo Único , Adulto Jovem
7.
Artigo em Inglês | MEDLINE | ID: mdl-33744597

RESUMO

The objective of this study was to develop and validate a highly sensitive method for the detection of oxycodone, noroxycodone, 6ß-oxycodol, 6α-oxycodol, oxymorphone, and noroxymorphone in blood by liquid chromatography tandem mass spectrometry. The analytes were extracted from blood (0.5 mL) using Bond Elut Certify Solid Phase Extraction columns, evaporated to dryness and reconstituted before analysis was performed on an Acquity UPLC® I-class coupled to a Waters Xevo TQD. Academy Standards Board Standard Practices for Method Development in Forensic Toxicology were used for the validation of this method. The limit of quantitation for all analytes was established at 0.5 ng/mL. Calibration range for noroxymorphone, oxymorphone, 6α-oxycodol and 6ß-oxycodol was 0.5-25 ng/mL and 0.5-100 ng/mL for noroxycodone and oxycodone. Precision (2.90-17.3%) and bias studies resulted in a ±15% deviation. There were no interferences observed from internal standard, matrix, or common drugs of abuse. Stability of all analytes at two concentrations at 24, 48, and 72 h in the autosampler did not exceed ±20% difference from the initial T0. Dilution integrity at a ten-fold dilution was acceptable as analyte concentrations ranged between (±18%) of the target concentration. Once validated, the method was used in a pilot dosing study of one male subject after taking a 10 mg immediate release tablet of oxycodone. Blood samples were collected at 0.25, 0.50, 0.75, 1.0, 1.5, 2, 3, 4, 5, 6, 8, 9, and 24 h after ingestion. Oxycodone and noroxycodone both reached Tmax at 1.5 h and had Cmax values of 25.9 and 12.8 ng/mL, respectively. Oxycodone, 6α-oxycodol, and 6ß-oxycodol were detectable up to 9 h, while noroxymorphone and noroxycodone were still detected at 24 h.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Morfinanos/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Morfinanos/química , Morfinanos/farmacocinética , Reprodutibilidade dos Testes
8.
J Anal Toxicol ; 45(2): 124-133, 2021 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-32435814

RESUMO

Oxycodone (OC) is an opioid with strong analgesic effects widely used to treat acute and chronic pain. Interpretation of OC concentrations in postmortem cases is complicated due to tolerance and overlapping concentrations for fatal and non-fatal levels. In this study, our aim was to develop and validate a method for OC and its three metabolites: noroxycodone (NOC), oxymorphone (OM) and noroxymorphone (NOM) in postmortem femoral blood. Our goal was to define reference concentrations for intoxications and non-intoxications and investigate metabolic ratios in different causes of death. A rapid LC-MS-MS method using protein-precipitated postmortem blood was developed. Lower limit of quantitation was 0.005 µg/g blood for all analytes; upper limit of quantitation was 1.0 µg/g for OC and NOC and 0.25 µg/g for OM and NOM. The method displayed high precision (3.3-7.7%) and low bias (-0.3 to 12%). In total, 192 cases were analyzed and concentrations ranged from 0.005 to 13 µg/g for OC, 0.005 to 2.0 µg/g for NOC, 0.005 to 0.24 µg/g for OM, and 0.005 to 0.075 µg/g for NOM. We found a significant difference in OC concentration between the cases where OC contributed and those where it did not. In spite of that, we do not recommend the use of a specific blood concentration to distinguish fatal intoxications. Instead, the percentiles from our data set suggest that concentrations >0.2 µg/g are likely to have contributed to toxicity, but that concentrations as high as 0.3 might be tolerated without toxic effects. In addition, we also found that a low NOC/OC ratio could point toward an acute fatal intoxication. In conclusion, the OC concentration alone may not be sufficient to diagnose a fatal intoxication.


Assuntos
Overdose de Opiáceos/sangue , Oxicodona/sangue , Detecção do Abuso de Substâncias/métodos , Cromatografia Líquida , Toxicologia Forense , Humanos , Espectrometria de Massas em Tandem
9.
J Anal Toxicol ; 45(3): 215-225, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33031535

RESUMO

Analysis of postmortem samples with the presence of morphine can sometimes be challenging to interpret. Tolerance complicates interpretation of intoxications and causes of death due to overlap in therapeutic and fatal concentrations. Determination of metabolites and metabolic ratios can potentially differentiate between abstinence, continuous administration, and perhaps time of administration. The purpose of this study was to (a) develop and validate a method for quantitation of morphine-3ß-D-glucuronide, morphine-6ß-D-glucuronide, normorphine, codeine-6ß-D-glucuronide, norcodeine, codeine, 6-acetylmorphine, and ethylmorphine in urine using liquid chromatography-tandem mass spectrometry; (b) apply the method to opiate related deaths; (c) compare metabolic ratios in urine in different causes of death (CoD) and after different drug intakes and (d) compare heroin intoxications in rapid and delayed deaths. Validation parameters such as precision, bias, matrix effects, stability, process efficiency, and dilution integrity were assessed and deemed acceptable. Lower limits of quantitation ranged from 0.01-0.2 µg/mL for all analytes. Autopsy cases (n=135) with paired blood and urine samples were analyzed. Cases were divided into three groups based on CoD; opiate intoxication, intoxication with other drugs than opiates, and other CoD. The cases were classified by intake: codeine (n=42), heroin (n=36), morphine (n=49), and ethylmorphine (n=3). Five cases were classified as mixed intakes and excluded. Heroin intoxications (n=35) were divided into rapid (n=15) or delayed (n=20) deaths. Parent drug groups were compared using metabolic ratio morphine-3ß-D-glucuronide/morphine and significant differences were observed between codeine vs morphine (p=0.005) and codeine vs heroin (p≤0.0001). Urine and blood concentrations, and metabolic ratios in rapid and delayed heroin intoxications were compared and determined a significant difference for morphine (p=0.001), codeine (p=0.009), 6-acetylmorphine (p=0.02) in urine, and morphine (p=0.02) in blood, but there was no significant difference (p=0.9) between metabolic ratios. Morphine-3ß-D-glucuronide results suggested a period of abstinence prior to death in 25% of the heroin intoxications.


Assuntos
Heroína , Espectrometria de Massas em Tandem , Analgésicos Opioides , Cromatografia Líquida , Codeína , Morfina , Derivados da Morfina , Detecção do Abuso de Substâncias
10.
Drug Test Anal ; 6 Suppl 1: 22-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24817045

RESUMO

A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated.


Assuntos
Anfetaminas/análise , Cromatografia Líquida de Alta Pressão/métodos , Cabelo/química , Detecção do Abuso de Substâncias/métodos , Espectrometria de Massas em Tandem/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA