Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Indian J Nucl Med ; 39(2): 98-105, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38989310

RESUMO

Purpose of the Study: The primary objective was to establish the reference values for liquid gastric emptying and small bowel. The secondary objectives encompassed comparing the anterior view and geometric mean methods, assessing gender differences, and exploring potential correlations with age. Materials and Methods: Thirty-five consecutive healthy participants (28 females and 7 males) with a mean age of 42 ± 11 years (median, 42; range, 23-65) underwent liquid gastric emptying scintigraphy at five intervals (0, 0.5, 1, 2, and 4 h), with optional additional imaging at 24 h. Liquid gastric emptying was evaluated using percent retention and half-time (T1/2). Small-bowel transit was assessed using the index of small-bowel transit (ISBT), calculated as the ratio of terminal ileal reservoir counts to total abdominal counts at 4 h. Reference values were established based on percentiles or mean and standard deviation (SD). Rapid small-bowel transit was determined through visual inspection. Statistical analysis involved paired Samples t-test or Wilcoxon signed-rank test for comparing imaging methods, independent Samples t-test or Mann-Whitney U-test for gender comparison, and Spearman's rank correlation for assessing age-related associations. A 2-tailed P < 0.05 indicated significance. Results: Rapid liquid gastric emptying based on the geometric mean method was defined as percent retention <8% at 30 min, while delayed emptying as percent retention >33%, >20%, and >4% at 1, 2, and 4 h, respectively. The reference range of T1/2 of gastric emptying was 10-60 min. The reference value for small-bowel transit using the geometric mean method was established as ISBT >30% at 4 h, while rapid small-bowel transit was defined as the first visualization of activity in the cecum-ascending colon within 1 h. Parameters for liquid gastric emptying and small-bowel transit were notably higher in the anterior view method compared to the geometric mean method (P ≤ 0.019), except for percent retention at 2 h (P = 0.510). Nevertheless, the obtained reference values, whether based on percentiles or mean and SD, showed no notable variance between the two methods to warrant clinical significance. Gender did not display an impact on liquid gastric emptying or small-bowel transit in either method (P ≥ 0.173), and age demonstrated no significant moderate or strong correlations (Spearman's ρ ≤ 0.397). Conclusion: The study determined reference values for liquid gastric emptying and small-bowel transit through a standard gastric emptying scintigraphy protocol, avoiding additional complex procedures or extended imaging sessions. The established normative data can apply to individuals of both genders aged ≥18 years. While advocating the geometric mean method as the primary choice, the study acknowledges that in busy centers handling multiple studies with limited resources and a single-head gamma camera catering to multiple studies, the anterior view method remains a feasible alternative.

2.
Indian J Nucl Med ; 39(2): 150-152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38989316

RESUMO

We present a case of a 22-year-old male patient who underwent a bone scan for evaluation of left condylar hyperplasia. Incidentally, the bone scan revealed bilateral thighs muscular uptake of technetium-99m methylene diphosphonate, which initially raised concerns for an underlying pathological process. However, further investigation revealed that the abnormal uptake was due to postexercise effects. This case report highlights the importance of considering benign causes of abnormal radiotracer uptake and the need for careful correlation with clinical history to avoid unnecessary diagnostic interventions.

3.
Neuroradiology ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39060800

RESUMO

PURPOSE: This study evaluates the efficacy of SISCOS (Subtraction ictal-interictal SPECT coregistered to SPECT) in localizing the epileptogenic zone (EZ) in focal cortical dysplasia (FCD), comparing its predictive performance with MRI and post-surgical outcomes based on ILAE classification. METHODS: 84 patients with drug refractory epilepsy (DRE) who were operated and had histopathology consistent with FCD, were included in the study. All patients had undergone a complete work-up including SISCOS and MRI for EZ localization, followed by discussion in the multidisciplinary epilepsy surgery meeting prior to surgery. Ictal & interictal perfusion SPECT studies were performed with Tc-99 m Ethylene Cysteinate Dimer (Tc-99 m ECD) followed by SISCOS analysis using SPM2 and Bioimage Suite 2.6. Concordance for localization was determined by comparing with the surgical resection site and post-surgical outcomes were assessed using the ILAE classification. RESULTS: The concordance for EZ localization demonstrated by SISCOS was 73.8% and MRI was 82.1%. 52 patients (61.9%) had good surgical outcome and 31(59%) of these were FCD type 2. In patients with discordant MRI findings, SISCOS was able to provide localisation in 86% (13/15), with 69.2% showing good surgical outcomes. Sensitivity of SISCOS and MRI was 73% (95% CI = 59-84.8%) and 78% (95% CI = 67.5-90.3%) respectively with no significant difference between the two. In FCD type I, both SISCOS and MRI revealed a similar a sensitivity of 76.4% (95%CI = 50.1-93.2%). Concordant cases exhibited higher seizure-free odds ratios for both modalities. CONCLUSION: SISCOS is effective in localizing the EZ in FCD patients, comparable to MRI. Integrating SISCOS and MRI enhances lesion detection, especially in MRI discordant cases. A comprehensive diagnostic approach utilizing SISCOS and MRI can optimize the non-invasive pre-surgical assessment in DRE thereby guiding surgical decision-making in a resource-limited setting.

4.
Indian J Nucl Med ; 39(1): 29-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38817721

RESUMO

Purpose of the Study: The primary objective was to establish the reference values for small-bowel and colonic transit within the context of the routine standard solid meal gastric emptying scintigraphy (GES). The secondary objective was to compare the small-bowel and colonic transit between the anterior view and geometric mean methods. Materials and Methods: Twenty-nine healthy controls underwent routine GES, with additional imaging at 24 h if feasible. Small-bowel transit was assessed using the index of small-bowel transit (ISBT), calculated as the ratio of terminal ileal reservoir counts to total abdominal counts at 4 h. Colonic transit was evaluated using the colonic geometric center (CGC) by dividing the large bowel into four segments, with an additional fifth segment accounting for the eliminated counts. Reference values were established based on the fifth percentile or mean ± 1.96 standard deviations. Rapid small-bowel transit was visually determined. Paired Samples t-test or Wilcoxon signed-rank test, as applicable, was used to compare the small-bowel and colonic transit between the anterior view and geometric mean methods. For comparing small-bowel and colonic transit between females and males, the Independent samples t-test or Mann-Whitney U-test was applied, as appropriate. The correlation between age and small-bowel and colonic transit was assessed using Spearman's rank correlation analysis. Results: The reference value for small-bowel transit using the geometric mean method was established as ISBT >37% at 4 h, whereas rapid small-bowel transit was defined as the first visualization of activity in the cecum-ascending colon within 2 h. For colonic transit, the reference range was established as CGC 2.8-4.4 at 24 h. Comparing the anterior view and geometric mean methods, there were no significant differences in ISBT and CGC values (P ≥ 0.125). Gender did not affect small-bowel and colonic transit in both methods (P ≥ 0.378), and age showed no significant correlations (P ≥ 0.053). Conclusion: This study determined the reference values for small-bowel and colonic transit in the Indian population using routine GES, avoiding the need for additional complex procedures. The results may be generalized to the Indian population, emphasizing the importance of assessing small-bowel and colonic transit in patients with normal gastric emptying parameters to enhance gastrointestinal transit evaluation.

5.
Nucl Med Mol Imaging ; 58(3): 150-151, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38633286

RESUMO

The prevalence of double primary prostate and bladder cancer is not uncommon. Though both share a common pathway of malignant transformation, they bear to differ in the case of 2-[18F]FDG PET/CT and [68Ga]Ga-PSMA uptake. We present a case of double primary cancer involving the bladder and prostate, where the prostatic primary showed intense [68Ga]Ga-PSMA uptake with non-avid skeletal and pulmonary metastases, which showed intense 2-[18F]FDG uptake, thus showing discordance due to different clonal origins.

6.
Clin Nucl Med ; 49(4): e168-e169, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350069

RESUMO

ABSTRACT: Pulmonary mucoepidermoid carcinoma (PMEC) is a rare pulmonary neoplasm. Although 18 F-FDG PET/CT has been shown to present with increased metabolic activity in PMEC, literature does not report increased somatostatin receptor expression in these tumors. We present the case of a 15-year-old boy where PMEC mimicked a typical carcinoid of the lung on DOTANOC PET/CT by showing significant uptake on 68 Ga-DOTANOC.


Assuntos
Tumor Carcinoide , Carcinoma Mucoepidermoide , Carcinoma Neuroendócrino , Neoplasias Pulmonares , Masculino , Humanos , Adolescente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18/metabolismo , Carcinoma Mucoepidermoide/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Pulmão/metabolismo
7.
Nucl Med Commun ; 45(2): 121-127, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982572

RESUMO

OBJECTIVE: F-18 Fluorodeoxyglucose PET/CT (FDG-PET) is emerging as a useful imaging adjunct to MRI in the initial diagnostic evaluation of autoimmune encephalitis (AIE)-though presently it is not included in the diagnostic criteria. MATERIALS AND METHODS: In this prospective study we enrolled a total of 52 patients with clinically diagnosed and treated AIE. MRI evaluation was done in each case along with CSF and EEG where feasible. FDG-PET was done for all and images were interpreted visually and using SPM. RESULTS: The mean age group of patients included was 38.5 ± 22.6 years with 31 females and 21 males. 23 antibody-positive cases underwent PET, the most common antibody detected was anti-NMDAR type followed by anti-LGI 1. Most common metabolic pattern in NMDARE was hypermetabolism in basal ganglia and hypometabolism in parieto-occipital cortices and ovarian teratoma was detected in two of these patients on whole-body PET. A metabolic pattern consistent with AIE was demonstrated in 22/29 (75.8%) antibody-negative patients with hypermetabolism in basal ganglia and mesial temporal cortices. The overall sensitivity of FDG PET was 86% (45/52). MRI abnormalities were detected in 22/52 (42%) cases, 10/23 antibody positive and 12/29 antibody negative cases. PET was positive in 23/30 (76%) MRI negative cases. CONCLUSION: Sensitivity of FDG PET for supporting a diagnosis of AIE was higher compared to MRI in both antibody-positive (definitive) and antibody-negative (presumed) AIE. Specific metabolic patterns can be demonstrated on FDG PET in AIE, prompting an early diagnosis so that timely treatment can be instituted.


Assuntos
Doenças Autoimunes do Sistema Nervoso , Fluordesoxiglucose F18 , Masculino , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética
8.
Indian J Nucl Med ; 38(3): 231-238, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38046967

RESUMO

Aim and Objective: The objective of this study was to optimize the threshold for discrete cosine transform (DCT) coefficients for near-lossless compression of Tc-99 m Dimercaptosuccinic acid (DMSA) scan images using discrete cosine transformation. Materials and Methods: Two nuclear medicine (NM) Physicians after reviewing several Tc-99 m DMSA scan images provided 242 Tc-99 m DMSA scan images that had scar. These Digital imaging and communication in medicine (DICOM) images were converted in the Portable Network Graphics (PNG) format. DCT was applied on these PNG images, which resulted in DCT coefficients corresponding to each pixel of the image. Four different thresholds equal to 5, 10, 15, and 20 were applied and then inverse discrete cosine transformation was applied to get the compressed Tc-99 m DMSA scan images. Compression factor was calculated as the ratio of the number of nonzero elements after thresholding DCT coefficients to the number of nonzero elements before thresholding DCT coefficients. Two NM physicians who had provided the input images visually compared the compressed images with its input image, and categorized the compressed images as either acceptable or unacceptable. The quality of compressed images was also assessed objectively using the following eight image quality metrics: perception-based image quality evaluator, structural similarity index measure (SSIM), multiSSIM, feature similarity indexing method, blur, global contrast factor, contrast per pixel, and brightness. Pairwise Wilcoxon signed-rank sum tests were applied to find the statistically significant difference between the value of image quality metrics of the compressed images obtained at different thresholds and the value of the image quality metrics of its input images at the level of significance = 0.05. Results: At threshold 5, (1) all compressed images (242 out of 242 Tc-99 m DMSA scan images) were acceptable to both the NM Physicians, (2) Compressed image looks identical to its original image and no loss of clinical details was noticed in compressed images, (3) Up to 96.65% compression (average compression: 82.92%) was observed, and (4) Result of objective assessment supported the visual assessment. The quality of compressed images at thresholds 10, 15, and 20 was significantly better than that of input images at P < 0.0001. However, the number of unacceptable compressed images at thresholds 10, 15, and 20 was 6, 38, and 70, respectively. Conclusions: Up to 96.65%, near-losses compression of Tc-99 m DMSA images was found using DCT by thresholding DCT coefficients at a threshold value equal to 5.

9.
Nucl Med Mol Imaging ; 57(6): 265-274, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37982099

RESUMO

Purpose: To assess the diagnostic efficacy of 99mTc-sulfur colloid lymphoscintigraphy in chylothorax and chylous ascites, and the utility of single-photon emission computed tomography-computed tomography (SPECT/CT) in localizing the sites of leaks. Methods: Data from patients who underwent lymphoscintigraphy for clinical suspicion of chylothorax or chylous ascites were retrospectively analyzed. Biochemical fluid analysis was taken as the reference standard. Pleural fluid triglyceride level > 110 mg/dL (with pleural fluid/serum ratio > 1) and a cholesterol level < 200 mg/dL (with pleural fluid/serum ratio < 1) were considered confirmatory for chylothorax. Ascitic fluid triglyceride level > 200 mg/dL with a low cholesterol level (ascites fluid/serum ratio < 1) was considered confirmatory for chylous ascites. Results: 26 patients (15 males, 57.7%) aged 9 months to 68 years were enrolled in the study. Based on the reference standard, 17 had chylothorax or chylous ascites (9 with surgical history). Lymphoscintigraphy was positive in 16 (with 1 false positive) and negative in 10 (with 2 false negatives). The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy of lymphoscintigraphy were 88.2% (63.6-98.5%), 88.9% (51.8-99.7%), 80.0% (51.6-93.8%), 93.8% (70.1-99.0%), and 88.5% (69.9-97.6%), respectively. SPECT/CT could localize sites of leaks in 61.5% (8/13) with a localization rate of 77.8% (7/9) and 25.0% (1/4) in patients with surgical and nonsurgical causes, respectively. Conclusion: 99mTc-sulfur colloid lymphoscintigraphy is a highly efficacious noninvasive modality to diagnose chylothorax or chylous ascites with a high positive predictive value. SPECT/CT could localize the sites of leaks more frequently in patients with surgical causes.

11.
Indian J Nucl Med ; 38(2): 140-144, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37456185

RESUMO

Diagnosis of cardiac infections, which includes infective endocarditis (IE) and cardiac device infections, despite having a high death rate, is still challenging. Frequently used modalities such as echocardiography, computed tomography (CT), and magnetic resonance imaging cannot confirm the presence of an active infection or extracardiac findings. Taking these things to consideration, newer guidelines have suggested the inclusion of 18F fluorodeoxyglucose positron emission tomography/CT (18F FDG PET/CT) in the workup of patients with suspected prosthetic valve IE. In this pictorial essay, we are demonstrating the utility of 18F-FDG PET/CT in varied cases of IE, cardiac implantable electronic devices, and coronary stent infection and how they helped in solving diagnostic dilemmas.

12.
Indian J Nucl Med ; 38(1): 8-15, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180179

RESUMO

Introduction: In this pilot study, we have proposed and evaluated pipelined application of the dynamic stochastic resonance (DSR) algorithm and block-matching 3D (BM3D) filter for the enhancement of nuclear medicine images. The enhanced images out of the pipeline were compared with the corresponding enhanced images obtained using individual applications of DSR and BM3D algorithm. Materials and Methods: Twenty 99m-Tc MDP bone scan images acquired on SymbiaT6 SPECT/CT gamma camera system fitted with low-energy high-resolution collimators were exported in DICOM format to a personal computer and converted into PNG format. These PNG images were processed using the proposed algorithm in MATLAB. Two nuclear medicine physicians visually compared each input and its corresponding three enhanced images to select the best-enhanced image. The image quality metrics (Brightness, Global Contrast Factor (GCF), Contrast per pixel (CPP), and Blur) were used to assess the image quality objectively. The Wilcoxon signed test was applied to find a statistically significant difference in Brightness, GCF, CPP, and Blur of enhanced and its input images at a level of significance. Results: Images enhanced using the pipelined application of SR and BM3D were selected as the best images by both nuclear medicine physicians. Based on Brightness, Global Contrast Factor (GCF), CPP, and Blur, the image quality of our proposed pipeline was significantly better than enhanced images obtained using individual applications of DSR and BM3D algorithm. The proposed method was found to be very successful in enhancing details in the low count region of input images. The enhanced images were bright, smooth, and had better target-to-background ratio compared to input images. Conclusion: The pipelined application of DSR and BM3D algorithm produced enhancement in nuclear medicine images having following characteristics: bright, smooth, better target-to-background ratio, and improved visibility of details in the low count regions of the input image, as compared to individual enhancements by application of DSR or BM3D algorithm.

13.
Indian J Nucl Med ; 38(1): 67-68, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180184

RESUMO

Uptake of 68Ga-prostate-specific membrane antigen (PSMA) in various nonprostatic tumors is well documented in the literature. We present a case of a gastrointestinal stromal tumor, incidentally detected on 68Ga-PSMA positron emission tomography/computed tomography imaging in a patient who underwent imaging for a suspected recurrence of carcinoma prostate.

14.
Indian J Nucl Med ; 38(1): 69-70, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37180195

RESUMO

Somatostatin receptor (SSTR) imaging is a useful method in the diagnosis of acute myocarditis. We present a case of a 54-year-old male with a clinical diagnosis of acute myocarditis in whom, 68Ga-DOTANOC positron emission tomography/computed tomography PET/CT showed diffuse left ventricular myocardial uptake. SSTR imaging can act as a surrogate marker of active inflammation. SSTR imaging is useful in deciding site of biopsy, assessing response to therapy and for prognostication.

15.
J Nucl Cardiol ; 30(5): 2213-2214, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36045251

RESUMO

Cardiac sarcoidosis usually occurs as a manifestation of systemic sarcoidosis, even though isolated cardiac involvement is not uncommon. The usefulness of 68Ga-DOTANOC PET/CT in the diagnosis of CS has been previously documented in the literature. We present a case of cardiac sarcoidosis, where 68Ga-DOTANOC PET/CT was used for monitoring response to therapy.


Assuntos
Miocardite , Compostos Organometálicos , Sarcoidose , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sarcoidose/diagnóstico por imagem
16.
Indian J Nucl Med ; 38(4): 392-393, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38390546

RESUMO

Tertiary hyperparathyroidism (THPT) is characterized by over secretion of parathyroid hormone caused by long-standing secondary hyperparathyroidism. THPT can affect the bones as well as cause extraskeletal calcifications. The bony lesions often mimic multiple skeletal metastases or multiple myeloma. We report a case of a 48-year-old man with chronic kidney disease on dialysis, who presented with chief complaints of low back ache and swelling over the left clavicle. In view of clinical suspicion of malignancy with bony metastases, he underwent 18F-fluorodeoxyglucose positron emission tomography/computed tomography and was subsequently found to have parathyroid adenomas, which were confirmed on 99mTc-methoxy-isobutyl-isonitrile scintigraphy.

17.
Nucl Med Commun ; 43(10): 1099-1106, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35989610

RESUMO

AIMS AND OBJECTIVES: The aim of the study is to compare the single matrix approach and slice-by-slice approach for computing singular value decomposition (SVD) to achieve near-lossless compression of PET/CT images. MATERIALS AND METHODS: The parameters used for comparison were SVD computation time, percentage compression and percentage difference between ROI counts on compressed and original images. SVD of 49 F-18-FDG PET/CT studies (33 370 PET/CT images) was computed using both approaches. The smaller singular values contributing insignificant information to the image were truncated, and then, the compressed image was reconstructed. A mask (101 × 101pixels) was used to extract the ROI counts from compressed and original images. Two nuclear medicine physicians compared compressed images with their corresponding original images for loss of clinical details and the presence of generated artifacts. Structural Similarity Index Measure, blur, brightness, contrast per pixel and global contrast factor were used for objective assessment of image quality. Wilcoxon test was applied to find a statistically significant difference between the parameters used for comparison at alpha = 0.05. RESULTS: Nuclear medicine physicians found compressed image identical to the corresponding original image. The values of comparation parameters were significantly larger for the single matrix approach in comparison with the slice-by-slice approach. The maximum percentage error between the compressed image and original image was less than 5%. CONCLUSIONS: Up to 64 % and 44% near-lossless compression of PET and CT images were achieved, respectively using the slice-by-slice approach, and up to 58 and 53% near-lossless compression of PET and CT images were achieved respectively using the single matrix approach.


Assuntos
Compressão de Dados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Algoritmos , Artefatos , Compressão de Dados/métodos , Fluordesoxiglucose F18 , Tomografia Computadorizada por Raios X
18.
PET Clin ; 17(3): 533-542, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35717106

RESUMO

The role of nuclear medicine for noninvasive assessment of infection and inflammation is well established. The role of nuclear medicine is limited to initial diagnosis, recurrence, and response assessment of infections and inflammations such as tuberculosis, sarcoidosis, vasculitis, osteomyelitis, immunoglobulin G4-related diseases, and coronavirus disease 2019, as the specificity is affected by false positivity due to physiologic fluorodeoxyglucose uptake in specific organ and nonspecific uptake in postoperative cases. PET with fludeoxyglucose F 18/CT is a well-established modality for diagnosis of fever of unknown origin helping in optimized management of the patient.


Assuntos
COVID-19 , Compostos Radiofarmacêuticos , COVID-19/diagnóstico por imagem , Fluordesoxiglucose F18 , Humanos , Inflamação/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos
19.
Nucl Med Commun ; 43(5): 518-528, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35102077

RESUMO

INTRODUCTION: In this study, the optimal input parameters point spread function (PSF) and the number of iterations of the Richardson-Lucy algorithm were experimentally determined to restore Tc-99 m methyl diphosphonate (MDP) whole-body bone scan images. MATERIALS AND METHODS: The experiment was performed on 60 anonymized Tc-99 m MDP whole-body bone scan images. Ten images were used for estimating the optimum value of PSF and the number of iterations to restore scintigraphic images. The remaining 50 images were used for validation of estimated parameters. The image quality of observed and restored images was assessed objectively using blind/referenceless image spatial quality evaluator (BRISQUE), mean brightness (MB), discrete entropy (DE), and edge-based contrast measure (EBCM) image quality metrics. Image quality was subjectively assessed by two nuclear medicine physicians (NMPs) by comparing the restored image quality with observed image quality and assigning a score to each image on the scale of 0-5. RESULTS: Based on BRISQUE, MB, DE, and EBCM scores, the restored images were significantly sharper, less bright, had more detailed information, and had less contrast around edges compared to the input images. The restored images had improved resolution based on visual assessment as well; NMPs assigned an average image quality score of 4.00 to restored images. Maximum resolution enhancement was noticed at PSF (size: 11 pixels, sigma: 1.75 pixels) and the number of iterations = 10. With the increase in the number of iterations, noise also gets amplified along with resolution enhancement and affects the detectability of small lesions; in the case of relatively low noisy input images, the number of iterations = 5 gave better results. CONCLUSION: Tc-99 m MDP bone scan images were restored to improve image quality using the Richardson-Lucy algorithm. The optimum value of the PSF parameter was found to be of size = 11 pixels and sigma = 1.75 pixels.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Cintilografia , Imagem Corporal Total
20.
Indian J Nucl Med ; 37(4): 404-405, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36817191

RESUMO

A 13-year-old adolescent male presented with an episode of rectal bleed. He has had five such episodes in the past year where he witnessed black tarry stools mixed with fresh blood, painless, not associated with fever or hematemesis. Clinical examination revealed pallor and a soft, non-tender abdomen. Vitals were stable. Blood investigations revealed haemoglobin of 102g/L, WBC count of 10 X 109/L and platelet count of 165 × 109/L. The clotting screen was normal. Upper GI endoscopy and colonoscopy revealed no abnormality. The patient underwent Tc-99m pertechnetate scintigraphy to look for Meckel's Diverticulum in view of painless lower GI bleed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA