1.
Sci Rep ; 14(1): 2962, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-38316842

RESUMO

Pulmonary artery catheterization (PAC) has been used as a clinical standard for cardiac output (CO) measurements on humans. On animals, however, an ultrasonic flow sensor (UFS) placed around the ascending aorta or pulmonary artery can measure CO and stroke volume (SV) more accurately. The objective of this paper is to compare CO and SV measurements using a noninvasive electrical impedance tomography (EIT) device and three invasive devices using UFS, PAC-CCO (continuous CO) and arterial pressure-based CO (APCO). Thirty-two pigs were anesthetized and mechanically ventilated. A UFS was placed around the pulmonary artery through thoracotomy in 11 of them, while the EIT, PAC-CCO and APCO devices were used on all of them. Afterload and contractility were changed pharmacologically, while preload was changed through bleeding and injection of fluid or blood. Twenty-three pigs completed the experiment. Among 23, the UFS was used on 7 pigs around the pulmonary artery. The percentage error (PE) between COUFS and COEIT was 26.1%, and the 10-min concordance was 92.5%. Between SVUFS and SVEIT, the PE was 24.8%, and the 10-min concordance was 94.2%. On analyzing the data from all 23 pigs, the PE between time-delay-adjusted COPAC-CCO and COEIT was 34.6%, and the 10-min concordance was 81.1%. Our results suggest that the performance of the EIT device in measuring dynamic changes of CO and SV on mechanically-ventilated pigs under different cardiac preload, afterload and contractility conditions is at least comparable to that of the PAC-CCO device. Clinical studies are needed to evaluate the utility of the EIT device as a noninvasive hemodynamic monitoring tool.


Assuntos
Pressão Arterial , Tomografia Computadorizada por Raios X , Humanos , Suínos , Animais , Volume Sistólico , Impedância Elétrica , Débito Cardíaco
2.
Sensors (Basel) ; 23(11)2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37300035

RESUMO

Electrical impedance tomography (EIT) can monitor the real-time hemodynamic state of a conscious and spontaneously breathing patient noninvasively. However, cardiac volume signal (CVS) extracted from EIT images has a small amplitude and is sensitive to motion artifacts (MAs). This study aimed to develop a new algorithm to reduce MAs from the CVS for more accurate heart rate (HR) and cardiac output (CO) monitoring in patients undergoing hemodialysis based on the source consistency between the electrocardiogram (ECG) and the CVS of heartbeats. Two signals were measured at different locations on the body through independent instruments and electrodes, but the frequency and phase were matched when no MAs occurred. A total of 36 measurements with 113 one-hour sub-datasets were collected from 14 patients. As the number of motions per hour (MI) increased over 30, the proposed algorithm had a correlation of 0.83 and a precision of 1.65 beats per minute (BPM) compared to the conventional statical algorithm of a correlation of 0.56 and a precision of 4.04 BPM. For CO monitoring, the precision and upper limit of the mean ∆CO were 3.41 and 2.82 L per minute (LPM), respectively, compared to 4.05 and 3.82 LPM for the statistical algorithm. The developed algorithm could reduce MAs and improve HR/CO monitoring accuracy and reliability by at least two times, particularly in high-motion environments.


Assuntos
Artefatos , Monitorização Hemodinâmica , Humanos , Impedância Elétrica , Reprodutibilidade dos Testes , Movimento (Física) , Tomografia Computadorizada por Raios X , Algoritmos , Tomografia/métodos
3.
Ann Biomed Eng ; 51(2): 394-409, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35960417

RESUMO

Continuous monitoring of both hemodynamic and respiratory parameters would be beneficial to patients, e.g., those in intensive care unit. The objective of this exploratory animal study was to test the feasibility of simultaneous measurements of relative tidal volume (rTV) and relative stroke volume (rSV) using an electrical impedance tomography (EIT) device equipped with a new real-time source separation algorithm implemented as two spatial filters. Five pigs were anesthetized and mechanically ventilated. The supplied tidal volume from a mechanical ventilator was reduced to 70, 50 and 30% from the 100% normal volume to simulate hypoventilation. The respiratory volume signal and cardiac volume signal were generated by applying the spatial filters to the acquired EIT data, from which values of rTV and rSV were extracted. The measured rTV values were compared with the TV values from the mechanical ventilator using the four-quadrant concordance analysis method. For changes in TV, the concordance rate in each animal ranged from 81.8% to 100%, while it was 92.5% when the data from all five animals were pooled together. When the measured rTV values for each animal were scaled to the absolute TVEIT values in mL using the TVVent data from the mechanical ventilator, the smallest 95% limits of agreement (LoA) were - 6.04 and 7.44 mL for the 70% ventilation level, and the largest 95% LoA were - 18.1 and 19.4 mL for the 50% ventilation level. The percentage error between TVEIT and TVVent was 10.3%. Although similar statistical analyses on rSV data could not be performed due to limited intra-animal variability, changes in rSV values measured by the EIT device were comparable to those measured by an invasive hemodynamic monitor. In this animal study, we were able to demonstrate the feasibility of an EIT device for noninvasive and simultaneous measurements of rTV and rSV in real time. However, the performance of the real-time source separation method needs to be further validated on animals and human subjects, particularly over a wide range of SV values. Future clinical studies are needed to assess the potential usefulness of the new method in dynamic cardiopulmonary monitoring and explore other clinical applications.


Assuntos
Tomografia , Humanos , Animais , Suínos , Volume de Ventilação Pulmonar , Estudos de Viabilidade , Tomografia/métodos , Volume Sistólico , Impedância Elétrica
4.
IEEE Trans Biomed Eng ; 69(6): 1964-1974, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34855581

RESUMO

OBJECTIVE: The objectives of this study were to develop a multi-channel trans-impedance leadforming method for beat-to-beat stroke volume (SV) and breath-by-breath tidal volume (TV) measurements and assess its feasibility on an existing in vivo animal dataset. METHODS: A deterministic leadforming algorithm was developed to extract a cardiac volume signal (CVS) and a respiratory volume signal (RVS) from 208-channel trans-impedance data acquired every 20 ms by an electrical impedance tomography (EIT) device. SVEIT and TVEIT values were computed as a valley-to-peak value in the CVS and RVS, respectively. The method was applied to the existing dataset from five mechanically-ventilated pigs undergoing ten mini-fluid challenges. An invasive hemodynamic monitor was used in the arterial pressure-based cardiac output (APCO) mode to simultaneously measure SVAPCO values while a mechanical ventilator provided TVVent values. RESULTS: The leadforming method could reliably extract the CVS and RVS from the 208-channel trans-impedance data measured with the EIT device, from which SVEIT and TVEIT were computed. The SVEIT and TVEIT values were comparable to those from the invasive hemodynamic monitor and mechanical ventilator. Using the data from 5 pigs and a simple calibration method to remove bias, the error in SVEIT and TVEIT was 9.5% and 5.4%, respectively. CONCLUSION: We developed a new leadforming method for the EIT device to robustly extract both SV and TV values in a deterministic fashion. Future animal and clinical studies are needed to validate this leadforming method in various subject populations. SIGNIFICANCE: The leadforming method could be an integral component for a new cardiopulmonary monitor in the future to simultaneously measure SV and TV noninvasively, which would be beneficial to patients.


Assuntos
Algoritmos , Tomografia , Animais , Impedância Elétrica , Estudos de Viabilidade , Humanos , Suínos , Volume de Ventilação Pulmonar , Tomografia/métodos
5.
Sci Rep ; 11(1): 24312, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34934083

RESUMO

The importance of perioperative respiration monitoring is highlighted by high incidences of postoperative respiratory complications unrelated to the original disease. The objectives of this pilot study were to (1) simultaneously acquire respiration rate (RR), tidal volume (TV), minute ventilation (MV), SpO2 and PETCO2 from patients in post-anesthesia care unit (PACU) and (2) identify a practical continuous respiration monitoring method by analyzing the acquired data in terms of their ability and reliability in assessing a patient's respiratory status. Thirteen non-intubated patients completed this observational study. A portable electrical impedance tomography (EIT) device was used to acquire RREIT, TV and MV, while PETCO2, RRCap and SpO2 were measured by a Capnostream35. Hypoventilation and respiratory events, e.g., apnea and hypopnea, could be detected reliably using RREIT, TV and MV. PETCO2 and SpO2 provided the gas exchange information, but were unable to detect hypoventilation in a timely fashion. Although SpO2 was stable, the sidestream capnography using the oronasal cannula was often unstable and produced fluctuating PETCO2 values. The coefficient of determination (R2) value between RREIT and RRCap was 0.65 with a percentage error of 52.5%. Based on our results, we identified RR, TV, MV and SpO2 as a set of respiratory parameters for robust continuous respiration monitoring of non-intubated patients. Such a respiration monitor with both ventilation and gas exchange parameters would be reliable and could be useful not only for respiration monitoring, but in making PACU discharge decisions and adjusting opioid dosage on general hospital floor. Future studies are needed to evaluate the potential clinical utility of such an integrated respiration monitor.

6.
Resuscitation ; 166: 66-73, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34271129

RESUMO

BACKGROUND: Seismocardiography measures the vibrations produced by the beating heart using an accelerometer sensor placed on the chest. We evaluated the ability of smartphone seismocardiography to distinguish between the presence and absence of spontaneous circulation. METHODS: Seismocardiography signals were obtained using a smartphone placed on the sternum in a convenience sample of 60 adult patients (30 comatose patients with spontaneous circulation and 30 deceased patients). The maximum, minimum, and standard deviation (SD) of acceleration values for head-to-foot, right-to-left, and dorsoventral axes and the three axis-root mean square (RMS) of the acceleration signals were calculated. Blinded observers (n = 156) were each asked to determine the presence or absence of spontaneous circulation based on seismocardiography video clips for each of the 60 patients. RESULTS: The seismocardiography revealed periodic large positive peaks in the patients with spontaneous circulation, which were absent in the patients without spontaneous circulation. For each of the four output measurements (three independent axes plus the three-axis RMS), the acceleration maxima and SD were significantly higher and the minima significantly lower in the patients with spontaneous circulation than in those without spontaneous circulation (all P < 0.001 except the minimum of three axis-RMS results [P = 0.009]). The observers accurately identified the seismocardiography signals from patients without spontaneous circulation, with a sensitivity of 97.6% (95% confidence interval, 97.0%-98.2%) and a specificity of 98.4% (95% confidence interval, 97.8%-99.0%). CONCLUSIONS: In conclusion, blinded observers accurately distinguished between seismocardiography signals from patients with and without spontaneous circulation.


Assuntos
Acelerometria , Smartphone , Aceleração , Adulto , Coração , Humanos , Vibração
7.
Sleep Breath ; 25(4): 2025-2038, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33683548

RESUMO

PURPOSE: Breath-by-breath tidal volume (TV) and beat-by-beat stroke volume (SV) were continuously measured in patients with OSA undergoing polysomnography (PSG). The objectives were to (1) determine the changes in TV/SV in response to respiratory events and (2) assess the relationship between these changes and the disease severity. METHODS: From the PSG data of nine patients with OSA, six different types of respiratory events were identified, i.e., flow limitation (FL), respiratory effort related arousal (RERA), hypopnea with arousal only (Ha), hypopnea with desaturation only (Hd), hypopnea with arousal and desaturation (Had), and apnea. The measured TV and SV values during and after each respiratory event were compared with the pre-event baseline values. RESULTS: The mean TV/SV reductions during all hypopneas and apneas were 38.1%/4.2% and 70.5%/8.8%, respectively. Among three different hypopnea types, the reductions in TV during Hd and Had were significantly greater than those during Ha. The TV reductions during Ha and FL were similar. After RERA, Ha, Had, and apnea, there was an overshoot in TV and SV values, whereas there was no overshoot after FL and Hd. During RERA, there was no reduction in TV/SV. CONCLUSIONS: The changes in TV during and after each type of respiratory event were significantly different in most cases. The changes in SV between hypopnea and apnea were different with statistical significance. The AHI does not properly account for the ventilation losses caused by respiratory events. Thus, TV measurements might be useful in the future in assessing the OSA severity in conjunction with the AHI.


Assuntos
Apneia Obstrutiva do Sono/fisiopatologia , Volume Sistólico/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Projetos Piloto , Polissonografia
8.
Shock ; 56(5): 850-856, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33534400

RESUMO

ABSTRACT: Cardiac output (CO) is an important parameter in fluid management decisions for treating hemodynamically unstable patients in intensive care unit. The gold standard for CO measurements is the thermodilution method, which is an invasive procedure with intermittent results. Recently, electrical impedance tomography (EIT) has emerged as a new method for noninvasive measurements of stroke volume (SV). The objectives of this paper are to compare EIT with an invasive pulse contour analysis (PCA) method in measuring SV during mini-fluid challenge in animals and determine preload responsiveness with EIT. Five pigs were anesthetized and mechanically ventilated. After removing 25% to 30% of the total blood from each animal, multiple fluid injections were conducted. The EIT device successfully tracked changes in SV beat-to-beat during varying volume states, i.e., from hypovolemia and preload responsiveness to target volume and volume overload. From a total of 50 100-mL fluid injections on five pigs (10 injections per pig), the preload responsiveness value was as large as 32.3% in the preload responsiveness state while in the volume overload state it was as low as -4.9%. The bias of the measured SV data using EIT and PCA was 0 mL, and the limits of agreement were ±3.6 mL in the range of 17.6 mL to 51.0 mL. The results of the animal experiments suggested that EIT is capable of measuring beat-to-beat SV changes during mini-fluid challenge and determine preload responsiveness. Further animal and clinical studies will be needed to demonstrate the feasibility of the EIT method as a new tool for fluid management.


Assuntos
Frequência Cardíaca , Volume Sistólico , Animais , Hidratação , Testes de Função Cardíaca/métodos , Modelos Animais , Suínos
9.
Sci Rep ; 10(1): 11242, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32647206

RESUMO

Currently, there is no noninvasive method available for simultaneous measurements of tidal volume and stroke volume. Electrical impedance tomography (EIT) has been used for regional lung ventilation imaging. Cardiac EIT imaging, however, has not been successful due to the technical difficulty in extracting weak cardiogenic components. Instead of regional imaging, in this paper, we use the EIT technique to simultaneously measure two global variables of tidal volume and stroke volume. Time-varying patterns of boundary voltage data originating from lung ventilation and cardiac blood flow were extracted from measured boundary voltage data using the principal component analysis (PCA) and independent component analysis (ICA). The source consistency theory was adopted to separately synthesize time-series of boundary voltage data associated with lung ventilation and cardiac blood flow. The respiratory volume signal (RVS) and cardiac volume signal (CVS) were extracted from reconstructed time-difference EIT images of lung ventilation and cardiac blood flow, respectively. After calibrating the volume signals using the mechanical ventilator and the invasive transpulmonary thermodilution (TPTD) method, tidal volume and stroke volume were computed as valley-to-peak values of the RVS and CVS, respectively. The difference in the tidal volume data between EIT and mechanical ventilator was within ± 20 ml from six pigs. The difference in the stroke volume data between EIT and TPTD was within ± 4.7 ml from the same animals. The results show the feasibility of the proposed method as a new noninvasive cardiopulmonary monitoring tool for simultaneous continuous measurements of stroke volume and tidal volume that are two most important vital signs.


Assuntos
Coração/diagnóstico por imagem , Modelos Animais , Modelos Cardiovasculares , Volume Sistólico , Volume de Ventilação Pulmonar , Animais , Calibragem , Eletrocardiografia , Eletrodos , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Pulmão/fisiologia , Análise de Componente Principal , Reprodutibilidade dos Testes , Respiração , Respiração Artificial , Suínos , Termodiluição
10.
Biomed Eng Online ; 18(1): 83, 2019 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-31345220

RESUMO

BACKGROUND: Electrical impedance tomography (EIT) has been used for functional lung imaging of regional air distributions during mechanical ventilation in intensive care units (ICU). From numerous clinical and animal studies focusing on specific lung functions, a consensus about how to use the EIT technique has been formed lately. We present an integrated EIT system implementing the functions proposed in the consensus. The integrated EIT system could improve the usefulness when monitoring of mechanical ventilation for lung protection so that it could facilitate the clinical acceptance of this new technique. METHODS: Using a custom-designed 16-channel EIT system with 50 frames/s temporal resolution, the integrated EIT system software was developed to implement five functional images and six EIT measures that can be observed in real-time screen view and analysis screen view mode, respectively. We evaluated the performance of the integrated EIT system with ten mechanically ventilated porcine subjects in normal and disease models. RESULTS: Quantitative and simultaneous imaging of tidal volume (TV), end-expiratory lung volume change ([Formula: see text]EELV), compliance, ventilation delay, and overdistension/collapse images were performed. Clinically useful parameters were successfully extracted including anterior/posterior ventilation ratio (A/P ratio), center of ventilation ([Formula: see text], [Formula: see text]), global inhomogeneity (GI), coefficient of variation (CV), ventilation delay and percentile of overdistension/collapse. The integrated EIT system was demonstrated to suggest an optimal positive end-expiratory pressure (PEEP) for lung protective ventilation in normal and in the disease model of an acute injury. Optimal PEEP for normal and disease model was 2.3 and [Formula: see text], respectively. CONCLUSIONS: The proposed integrated approach for functional lung ventilation imaging could facilitate clinical acceptance of the bedside EIT imaging method in ICU. Future clinical studies of applying the proposed methods to human subjects are needed to show the clinical significance of the method for lung protective mechanical ventilation and mechanical ventilator weaning in ICU.


Assuntos
Pulmão/fisiologia , Ventilação Pulmonar , Tomografia/métodos , Animais , Impedância Elétrica , Software , Suínos , Volume de Ventilação Pulmonar
11.
Physiol Meas ; 39(12): 124004, 2018 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-30523963

RESUMO

OBJECTIVE: Quantitative ventilation monitoring and respiratory event detection are needed for the diagnosis of sleep apnea and hypoventilation. We developed a portable device with a chest belt, nasal cannula and finger sensor to continuously acquire multi-channel signals including tidal volume, nasal pressure, respiratory effort, body position, snoring sound, ECG and SpO2. The unique feature of the device is the continuous tidal volume signal obtained from real-time lung ventilation images produced by the electrical impedance tomography (EIT) technique. APPROACH: The chest belt includes 16 electrodes for real-time time-difference EIT imaging and ECG data acquisitions. It also includes a microphone, accelerometer, gyroscope, magnetometer and pressure sensor to acquire, respectively, snoring sound, respiratory effort, body position and nasal pressure signals. A separate finger sensor is used to measure SpO2. The minute ventilation signal is derived from the tidal volume signal and respiration rate. MAIN RESULTS: The experimental results from a conductivity phantom, four swine subjects and one human volunteer show that the developed multi-parameter EIT device could supplement existing polysomnography (PSG) and home sleep test (HST) devices to improve the accuracy of sleep apnea diagnosis. The portable device could be also used as a new tool for continuous hypoventilation monitoring of non-intubated patients with respiratory depression. SIGNIFICANCE: Following the feasibility study in this paper, future validation studies in comparison with in-lab PSG, HST and end-tidal CO2 devices are suggested to find its clinical efficacy as a sleep apnea diagnosis and hypoventilation monitoring tool.


Assuntos
Hipoventilação/complicações , Hipoventilação/diagnóstico por imagem , Monitorização Fisiológica/instrumentação , Síndromes da Apneia do Sono/complicações , Tomografia , Animais , Impedância Elétrica , Desenho de Equipamento , Estudos de Viabilidade , Hipoventilação/fisiopatologia , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Polissonografia , Processamento de Sinais Assistido por Computador , Software , Suínos , Fatores de Tempo