Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Physiol Meas ; 38(3): 539-554, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28151429

RESUMO

OBJECTIVE: Near-infrared spectroscopy (NIRS) measurements of tissue oxygen saturation (StO2) are useful for the assessment of skeletal muscle perfusion and function during exercise, however, they are influenced by overlying skin and adipose tissue. This study explored the extent and nature of the influence of adipose tissue thickness (ATT) on StO2. APPROACH: NIR spatially resolved spectroscopy (SRS) derived oxygenation was measured on vastus lateralis in 56 patients with chronic heart failure (CHF) and 20 healthy control (HC) subjects during rest and moderate intensity exercise with simultaneous assessment of oxygen uptake kinetics (τ [Formula: see text]). In vitro measurements were performed on a flow cell with a blood mixture with full oxygen saturation (100%), which was gradually decreased to 0% by adding sodium metabisulfite. Experiments were repeated with 2 mm increments of porcine fat layer between the NIRS device and flow cell up to 14 mm. MAIN RESULTS: Lower ATT, higher τ [Formula: see text], and CHF were independently associated with lower in vivo StO2 in multiple regression analysis, whereas age and gender showed no independent relationship. With greater ATT, in vitro StO2 was reduced from 100% to 74% for fully oxygenated blood and increased from 0% to 68% for deoxygenated blood. SIGNIFICANCE: This study shows that ATT independently confounds NIR-SRS derived StO2 by overestimating actual skeletal muscle oxygenation and by decreasing its sensitivity for deoxygenation. Because physiological properties (e.g. presence of disease and slowing of τ [Formula: see text]) also influence NIR-SRS, a correction based on optical properties is needed to interpret calculated values as absolute StO2.


Assuntos
Tecido Adiposo/citologia , Tecido Adiposo/patologia , Músculo Esquelético/metabolismo , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Doença Crônica , Feminino , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/patologia , Humanos , Masculino , Pessoa de Meia-Idade
2.
Clin Physiol Funct Imaging ; 37(1): 68-78, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26147875

RESUMO

The potential purpose of near-infrared spectroscopy (NIRS) as a clinical application in patients with chronic heart failure (CHF) is the identification of limitations in O2 delivery or utilization during exercise. The objective of this study was to evaluate absolute and relative test-retest reliability of skeletal muscle oxygenation measurements in patients with CHF. Thirty patients with systolic heart failure (left ventricular ejection fraction 31 ± 8%) performed 6-min constant-load cycling tests at 80% of the anaerobic threshold (AT) with tissue saturation index (TSI) measurement at the vastus lateralis. Tests were repeated after 10 ± 5 days to evaluate reliability. Absolute reliability was assessed with limits of agreement (LoA, expressed as bias ± random error) and coefficients of variation (CV) for absolute values (LoA range: 0·4 ± 6·2% to 0·6 ± 7·9%; CV range: 4·7-7·1%), amplitudes (LoA range -0·5 ± 5·8% to -0·7 ± 6·8%; CV range: 26·2-42·1%), onset and recovery kinetics (mean response times; LoA 0·4 ± 9·5 s, CV 23·5% and LoA -5·8 ± 50·8 s, CV 67·4% respectively) and overshoot characteristics (CV range 45·7-208·6%). Relative reliability was assessed with intraclass correlation coefficients for absolute values (range 0·74-0·90), amplitudes (range 0·85-0·92), onset and recovery kinetics (0·53 and 0·51, respectively) and overshoot characteristics (range 0·17-0·74). In conclusion, absolute reliability of absolute values and onset kinetics seems acceptable for serial within-subject comparison, and as such, for evaluation of treatment effects. Absolute reliability of amplitudes and recovery kinetics is considered unsatisfactory. Relative reliability of absolute values and amplitudes is sufficient for purposes of physiological distinction between patients with CHF. Despite lower relative reliability, kinetics may still be useful for clinical application.


Assuntos
Ciclismo , Reabilitação Cardíaca/métodos , Terapia por Exercício/métodos , Insuficiência Cardíaca/reabilitação , Músculo Esquelético/irrigação sanguínea , Consumo de Oxigênio , Oxigênio/sangue , Espectroscopia de Luz Próxima ao Infravermelho , Idoso , Limiar Anaeróbio , Biomarcadores/sangue , Teste de Esforço , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
J Exerc Sci Fit ; 15(1): 43-47, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29541131

RESUMO

PURPOSE: It is still equivocal whether oxygen uptake recovery kinetics are limited by oxygen delivery and can be improved by supplementary oxygen. The present study aimed to investigate whether measurements of muscle and pulmonary oxygen uptake kinetics can be used to assess oxygen delivery limitations in healthy subjects. METHODS: Sixteen healthy young adults performed three sub-maximal exercise tests (6 min at 40% Wmax) under hypoxic (14%O2), normoxic (21%O2) and hyperoxic (35%O2) conditions on separate days in randomized order. Both Pulmonary VO2 and near infra red spectroscopy (NIRS) based Tissue Saturation Index (TSI) offset kinetics were calculated using mono-exponential curve fitting models. RESULTS: Time constant τ of VO2 offset kinetics under hypoxic (44.9 ± 7.3s) conditions were significantly larger than τ of the offset kinetics under normoxia (37.9 ± 8.2s, p = 0.02) and hyperoxia (37±6s, p = 0.04). TSI mean response time (MRT) of the offset kinetics under hypoxic conditions (25.5 ± 13s) was significantly slower than under normoxic (15 ± 7.7, p = 0.007) and hyperoxic (13 ± 7.3, p = 0.008) conditions. CONCLUSION: The present study shows that there was no improvement in the oxygen uptake and muscle oxygenation recovery kinetics in healthy subjects under hyperoxic conditions.Slower TSI and VO2 recovery kinetics under hypoxic conditions indicate that both NIRS and spiro-ergometry are appropriate non-invasive measurement tools to assess the physiological response of a healthy individual to hypoxic exercise.

4.
BMC Cardiovasc Disord ; 15: 57, 2015 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-26100151

RESUMO

BACKGROUND: Patients with chronic heart failure (CHF) suffer from exercise intolerance due to impaired central hemodynamics and subsequent alterations in peripheral skeletal muscle function and structure. The relative contribution of central versus peripheral factors in the reduced exercise capacity is still subject of debate. The main purpose was to investigate heterogeneity in the nature of exercise intolerance by evaluating individual cardiac output (Q) patterns. The secondary purpose was to evaluate whether patient and disease characteristics were associated with a central hemodynamic exercise limitation. METHODS: Sixty-four stable CHF patients performed a symptom limited incremental exercise test with respiratory gas analysis and simultaneous assessment of Q, using a radial artery pulse contour analysis method. A central hemodynamic exercise limitation was defined as a plateau or decline in Q from 90 to 100 % of exercise duration. RESULTS: Data from 61 patients were analyzed. A central hemodynamic exercise limitation was observed in 21 patients (34 %). In these patients, a higher occurrence of a plateau/decrease in oxygen uptake (VO2) (52 % vs 23 %, p = 0.02), stroke volume (SV) (100 % vs. 75 %, p = 0.01) and chronotropic incompetence (31 % vs. 2.5 %, p = 0.01) was observed, while presence of a left bundle branch block (LBBB) occurred significantly less (19 % vs 48 %, p = 0.03) There was no difference in disease characteristics such as etiology, duration, NYHA class, mitral regurgitation or ischemia. CONCLUSIONS: The study revealed considerable heterogeneity in the nature of exercise limitations between moderately impaired CHF patients. In one third of the study population a plateau or decrease in Q towards peak exercise was demonstrated, which is indicative of a central hemodynamic exercise limitation. A central hemodynamic exercise limitation was associated with an impairment to augment stroke volume and heart rate.


Assuntos
Débito Cardíaco , Tolerância ao Exercício , Insuficiência Cardíaca/fisiopatologia , Consumo de Oxigênio , Volume Sistólico , Idoso , Bloqueio de Ramo/complicações , Bloqueio de Ramo/fisiopatologia , Estudos de Coortes , Teste de Esforço , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Troca Gasosa Pulmonar , Análise de Onda de Pulso , Artéria Radial , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA