RESUMO
Right ventricular failure (RVF) is a common complication that occurs after a left ventricular assist device (LVAD) is implanted. We report an interesting case of severe and refractory hypoxia during the early postoperative period after HeartMate3 (HM3) (Abbott Laboratories, Lake Forest, IL) implantation resulting in the unmasking of a right-to-left intracardiac shunt through a patent foramen ovale (PFO), triggered by early RVF. Importantly, the patient had a small left-to-right shunt after receiving a left-sided Impella 5.5 micro-axial pump (Abiomed, Danvers, MA, USA) pre-LVAD implantation. We observed improved hypoxia but worsening RVF after percutaneous PFO closure, necessitating right-sided mechanical circulatory support. We outline potential reasons for the significant PFO-related shunting seen after HM3 implantation, but not after Impella 5.5 placement. Uncertainty exists regarding the approach to a PFO in patients undergoing LVAD implantation. We propose an approach based on existing literature.
RESUMO
BACKGROUND: The Minnesota Pectoralis Risk Score (MPRS) utilizes computed tomography-quantified thoracic muscle and clinical variables to predict survival after left ventricular assist device (LVAD) implantation. The model has not been prospectively tested in HeartMate 3 recipients. METHODS: A single-center HeartMate 3 cohort from July 2016 to July 2021 (n = 108) was utilized for this analysis. Cohort subjects with complete covariates for MPRS calculation (pectoralis muscle measures, Black race, creatinine, total bilirubin, body mass index, bridge to transplant status, and presence/absence of contrast) implanted after MPRS development were included. MPRS were calculated on each subject. Receiver operating characteristic curves were generated to test model discrimination at 30-day, 90-day, and 1-year mortality post-LVAD. Next, the performance of the 1-year post-LVAD outcome was compared to the HeartMate 3 survival risk score (HM3RS). RESULTS: The mean age was 58 (15 years), 80% (86/108) were male, and 26% (28/108) were destination therapy. The area under the curve (AUC) for the MPRS model to predict post-LVAD mortality was 0.73 at 30 days, 0.78 at 90 days, and 0.81 at 1 year. The AUC for the HM3RS for the 1-year outcome was 0.693. Each 1-unit point of the MPRS was associated with a significant increase in the hazard rate of death after LVAD (hazard ratio 2.1, 95% confidence interval 1.5-3.0, p < 0.0001). CONCLUSIONS: The MPRS had high performance in this prospective validation, particularly with respect to 90-day and 1-year post-LVAD mortality. Such a tool can provide additional information regarding risk stratification to aid informed decision-making.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Insuficiência Cardíaca/cirurgia , Minnesota , Fatores de Risco , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Background and Aims: Transcatheter aortic valve replacement (TAVR) is the mainstay of treatment of inoperable and severe high-risk aortic stenosis and is noninferior to surgical aortic valve replacement (SAVR) for low-risk and intermediate-risk patients as well. We aim to compare the valve size, area, and transaortic mean gradients in SAVR patients before and after the implementation of TAVR since being approved by the Food and Drug Administration in 2011. Methods: Patients who underwent a bioprosthetic SAVR placement were divided into two groups based on the date of procedure: the early pre-TAVR implementation group (years 2011-2012) and the contemporary post-TAVR group (years 2019-2020). The primary endpoint was the mean gradient across the aortic valve within 16 months of surgery. The secondary endpoints included the difference in valve size and various aortic valve echocardiographic variables. Results: One hundred and thirty patients had their valves replaced in the years 2011-2012 and 134 in the years 2019-2020. The early group had a significantly higher mean gradient (median of 13 mmHg [interquartile range, IQR: 9.3-18] vs. 10 mmHg [IQR: 7.5-13.1], p = 0.001) and a smaller median effective orifice area index (0.8 cm2/m2 [IQR: 0.6-1] vs. 1.1 cm2/m2 [IQR: 0.8-1.3], p < 0.001). The median valve size was significantly smaller in the early group (median of 21 mm [IQR: 21-23] vs. 23 mm [IQR: 22.5-25], p < 0.001). Conclusion: In the contemporary era, surgical patients receive larger valves which translates into lower mean gradients, larger valve area, and lower rates of patient-prosthesis mismatch than in previous years before the routine introduction of TAVR.
RESUMO
PURPOSE OF REVIEW: Thyroid disorders, especially hypothyroidism, are known to be associated with pericardial diseases. The aim of this paper is to review the current knowledge of the pericardial manifestations of hypothyroidism and hyperthyroidism. RECENT FINDINGS: Many reports have described associations between dysthyroidism, which encompasses hypothyroidism and hyperthyroidism, and several pericardial diseases, including acute pericarditis, constrictive pericarditis, pericardial effusion, and tamponade. The diagnosis of dysthyroidism-induced pericardial diseases consists of a combination of thyroid blood levels that fall outside of the normal range and the exclusion of other causes. Treatment of the thyroid disorder is key, along with treatment of the pericardial disease as recommended by the guidelines. Early recognition of the thyroid disorder is key in patients with pericardial diseases, since treating the underlying cause should assist resolution of the pericardial issues and ideally prevent recurrence and possible future complications of suboptimally treated pericarditis or pericardial effusions.
Assuntos
Tamponamento Cardíaco , Hipertireoidismo , Hipotireoidismo , Derrame Pericárdico , Pericardite Constritiva , Pericardite , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Humanos , Hipertireoidismo/complicações , Hipotireoidismo/complicações , Derrame Pericárdico/complicações , Derrame Pericárdico/terapia , Pericardite/complicações , Pericardite/terapia , Pericardite Constritiva/diagnóstico , Pericardite Constritiva/etiologia , Pericardite Constritiva/terapiaRESUMO
The association between ventricular arrhythmias (VAs) and mortality in patients supported by continuous flow left ventricular assist devices (LVAD) remains controversial. To evaluate the association between pre-implantation, early (≤ 30 day) post-implantation VAs and mortality in bridge to transplant (BTT) and destination therapy (DT) LVAD patients, separately. The risk factors for post LVAD VAs were also investigated. In this observational cohort study, we included 341 patients who received a first time, continuous flow LVAD between January 1st 2010 and July 30th 2018. We used Kaplan-Meier curves and multivariable cox regression analyses to study the association between VAs and mortality in the BTT and DT populations. The mean age of the cohort was 58 ± 14 years, with 82% males, 53% had ischemic cardiomyopathy, and 45% were DT. The mean follow-up was 2.2 ± 2.1 years. In both BTT and DT cohorts, pre LVAD VAs were not associated with mortality after LVAD implantation (log-rank p = 0.95 and p = 0.089, respectively). In the BTT population, early post-LVAD VAs were not statistically associated with increased mortality (log rank p = 0.072). In the DT patients, early post LVAD VAs were associated with a 67% increase in the hazards rate of mortality on LVAD support (HR 1.67 [1.05-2.65], p = 0.029). The final model was adjusted for type of cardiomyopathy, INTERMACS profile, glomerular filtration rate, post LVAD atrial fibrillation, age and cerebrovascular events. Early post-LVAD VA is common after LVAD implantation and is an independent predictor of mortality in the DT LVAD population.