Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Ann Lab Med ; 42(6): 621-629, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35765870

RESUMO

Background: Anti-Müllerian hormone (AMH) is one of the most reliable markers of ovarian reserve. Automated AMH assays are widely used in clinical laboratories, but reference intervals for the Elecsys AMH assay for Asian populations have not yet been determined. We aimed to determine reference intervals in healthy Korean women. Methods: The study included 1,450 women aged 19 to 54 years who participated in the Korea National Health and Nutrition Examination Survey between 2013 and 2016. The study participants were divided into seven 5-year age groups. AMH and progesterone concentrations were measured using Roche Elecsys assays, and bone morphogenetic protein-15 (BMP15) was genotyped for the detection of major variants. Age group-specific reference intervals for AMH were established as recommended by the CLSI EP28-A3c guidelines. Results: The mean age was 37.4 years. AMH concentrations decreased with increasing age, especially after 40 years, with the median AMH decreasing from 30.9 pmol/L in participants of 19-24 years to 0.071 pmol/L in participants of 50-54 years. The mid-95 percentile AMH reference intervals decreased from 7.93-81.21 pmol/L in participants of 19-24 years to 0.07-3.86 pmol/L in participants of 50-54 years. Disease-associated BMP15 variants were not detected. Conclusions: We determined Elecsys AMH assay reference intervals in healthy Korean women. The results may provide basic information for the interpretation of AMH concentrations and assessment of ovarian reserve in Korean women.


Assuntos
Hormônio Antimülleriano , Reserva Ovariana , Adulto , Povo Asiático/genética , Feminino , Humanos , Inquéritos Nutricionais , Valores de Referência
2.
Clin Lab ; 67(6)2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34107631

RESUMO

BACKGROUND: Essential trace elements play key roles in multiple biological systems, and hemodialysis patients are at risk for deficiency of essential trace elements. The aim of the study was to assess the essential element status in end stage renal disease patients undergoing online hemodiafiltration (online HDF) in outpatient dialysis clinic. METHODS: A total of 28 Korean patients with regular online HDF were included. Blood samples were collected before and after one HDF session, and serum concentrations of zinc, copper, selenium, and manganese were simulta-neously measured by inductively coupled plasma mass spectrometry. RESULTS: Selenium, zinc, copper deficiencies were observed in 71.4%, 35.8%, and 21.4%, compared with the reference range. No patients revealed manganese deficiency. After the HDF, the post-HDF level significantly increased in all trace elements, compared with the pre-HDF (11.2% for selenium, 10.7% for copper, and 6.6% for zinc). However, 50% patients were still deficient for selenium at the post-HDF. CONCLUSIONS: Our data suggest that the patients undergoing online HDF are at an increased risk of trace element deficiency, especially for selenium.


Assuntos
Hemodiafiltração , Selênio , Oligoelementos , Idoso , Cobre , Humanos , Zinco
3.
Scand J Clin Lab Invest ; 78(6): 477-482, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30073867

RESUMO

Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.


Assuntos
Anticorpos Antiproteína Citrulinada/sangue , Artrite Reumatoide/diagnóstico , Automação Laboratorial/normas , Imunoensaio/normas , Osteoartrite/diagnóstico , Adulto , Idoso , Artrite Reumatoide/sangue , Artrite Reumatoide/imunologia , Artrite Reumatoide/patologia , Biomarcadores/sangue , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/sangue , Osteoartrite/imunologia , Osteoartrite/patologia , Curva ROC
4.
Medicine (Baltimore) ; 97(30): e11594, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30045292

RESUMO

Hand washing plays a key role in preventing respiratory infection in many clinical settings. However, its effectiveness in preventing acute respiratory illness (ARI) during field training in military training facilities has been not studied.A quasi-interventional study was performed to evaluate the prevalence of ARIs over 4 weeks in a Korean army training center in South Korea from January 2009 to February 2009. A total of 1291 recruits participating in military training for 4 weeks were randomly distributed to 2 battalions (one with 631 and the other with 660). After noticing there is a difference between the 2 battalions in terms of the development of ARIs at the end of 2 weeks of training, we conducted interviews with the battle commanders to determine factors that may be related to one battalion having a higher incidence of ARI. Thereafter, we performed an intervention, which consists of instructing the battalion having a higher incidence of ARI to implement field hand washing from the third week. Following the intervention, we compared the cumulative rate of ARI during 4 weeks of training.The interviews revealed that there were no major differences between the 2 battalions in terms of the training schedules, living environments, or indoor hand washing methods. However, there was difference in terms of hand washing during field training for the first 2 weeks; whereas one battalion (the early hand washing group) implemented hand washing during field training starting in the first week, the other battalion did not implement hand washing for the first 2 weeks but instead began in the third week (the late hand washing group). The cumulative incidence rate of ARI during 4 weeks of training was significantly lower in the early hand washing group (13.0%, 95% confidence interval [CI]: 10.6%-15.9%) than in the late hand washing group (28.0%, 95% CI, 24.7%-31.5%).Our study suggests that outdoor hand washing during field training may be an effective precaution for reducing ARI incidence among recruits participating in military training.


Assuntos
Desinfecção das Mãos/métodos , Higiene Militar/métodos , Militares/educação , Doenças Profissionais/prevenção & controle , Infecções Respiratórias/prevenção & controle , Humanos , Incidência , Instalações Militares , Ensaios Clínicos Controlados não Aleatórios como Assunto , Doenças Profissionais/epidemiologia , Prevalência , República da Coreia/epidemiologia , Infecções Respiratórias/epidemiologia
6.
Clin Chem Lab Med ; 55(8): 1234-1242, 2017 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-28107170

RESUMO

BACKGROUND: Quantification of glycated hemoglobin (HbA1c) is a challenge in patients with hemoglobin (Hb) variants. We evaluated the impact of various Hb variants on five routine HbA1c assays by comparing with the IFCC reference measurement procedure (RMP). METHODS: Whole blood samples showing warning flags or no results on routine HPLC HbA1c assays were confirmed for Hb variants and were submitted to HbA1c quantification using Sebia Capillarys 2 Flex Piercing, Roche Tina-quant HbA1c Gen. 2, Bio-Rad Variant II Turbo 2.0, ADAMS HA-8180, Tosoh G8 standard mode, and IFCC RMP using LC-MS. RESULTS: Among 114 samples, the most common variants were Hb G-Coushatta (n=47), Queens (n=41), Ube-4 (n=11), Chad (n=4), Yamagata (n=4), G-His-Tsou (n=2), G-Taipei (n=1), Fort de France (n=1), Hoshida (n=1), and two novel variants (Hb α-globin, HBA 52 Gly>Cys and Hb ß-globin, HBB 146 His>Asn). In terms of control samples, all the result of HbA1c were "acceptable", within the criteria of ±7% compared to IFCC RMP target values. However, percentage of "unacceptable" results of samples with Hb variants were 16% for Capillarys 2, 7% for Tina-quant, 51% for Variant II Turbo 2.0, 95% for G8 standard mode, and 89% for HA-8180. The Capillarys 2 and HA-8180 assay did not provide the results in 5 and 40 samples with Hb variants, respectively. CONCLUSIONS: HbA1c results from five routine assays in patients with relatively common Hb variants in Korea showed various degrees of bias compared to those of IFCC RMP. Therefore, laboratories should be aware of the limitation of their methods with respect to interference from Hb variants found commonly in their local population and suggest an alternative HbA1c quantification method.


Assuntos
Análise Química do Sangue/métodos , Hemoglobinas Glicadas/análise , Hemoglobinas Glicadas/genética , Análise Química do Sangue/normas , Cromatografia Líquida de Alta Pressão , Humanos , Espectrometria de Massas , Mutação , Padrões de Referência , República da Coreia
7.
Ann Lab Med ; 37(2): 180-193, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28029011

RESUMO

Pharmacogenetic testing for clinical applications is steadily increasing. Correct and adequate use of pharmacogenetic tests is important to reduce unnecessary medical costs and adverse patient outcomes. This document contains recommended pharmacogenetic testing guidelines for clinical application, interpretation, and result reporting through a literature review and evidence-based expert opinions for the clinical pharmacogenetic testing covered by public medical insurance in Korea. This document aims to improve the utility of pharmacogenetic testing in routine clinical settings.


Assuntos
Testes Farmacogenômicos/métodos , Anticoagulantes/uso terapêutico , Antidepressivos/uso terapêutico , Antimetabólitos Antineoplásicos/uso terapêutico , Antituberculosos/uso terapêutico , Arilamina N-Acetiltransferase/genética , Clopidogrel , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/genética , Citocromo P-450 CYP2C19/genética , Citocromo P-450 CYP2C9/genética , Citocromo P-450 CYP2D6/genética , Transtorno Depressivo/tratamento farmacológico , Transtorno Depressivo/genética , Genótipo , Isoniazida/uso terapêutico , Laboratórios Hospitalares/normas , Metiltransferases/genética , Testes Farmacogenômicos/normas , Inibidores da Agregação Plaquetária/uso terapêutico , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/genética , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Tuberculose/tratamento farmacológico , Tuberculose/genética , Vitamina K Epóxido Redutases/genética , Varfarina/uso terapêutico
8.
Ann Lab Med ; 37(1): 1-8, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27834059

RESUMO

BACKGROUND: For correct interpretation of the high-density lipoprotein cholesterol (HDL-C) data from the Korea National Health and Nutrition Examination Survey (KNHANES), the values should be comparable to reference values. We aimed to suggest a way to calibrate KNHANES HDL-C data from 2008 to 2015 to the Centers for Disease Control and Prevention (CDC) reference method values. METHODS: We derived three calibration equations based on comparisons between the HDL-C values of the KNHANES laboratory and the CDC reference method values in 2009, 2012, and 2015 using commutable frozen serum samples. The selection of calibration equation for correcting KNHANES HDL-C in each year was determined by the accuracy-based external quality assurance results of the KNHANES laboratory. RESULTS: Significant positive biases of HDL-C values were observed in all years (2.85-9.40%). We created the following calibration equations: standard HDL-C=0.872×[original KNHANES HDL-C]+2.460 for 2008, 2009, and 2010; standard HDL-C=0.952×[original KNHANES HDL-C]+1.096 for 2012, 2013, and 2014; and standard HDL-C=1.01×[original KNHANES HDL-C]-3.172 for 2011 and 2015. We calibrated the biases of KNHANES HDL-C data using the calibration equations. CONCLUSIONS: Since the KNHANES HDL-C values (2008-2015) showed substantial positive biases compared with the CDC reference method values, we suggested using calibration equations to correct KNHANES data from these years. Since the necessity for correcting the biases depends on the characteristics of research topics, each researcher should determine whether to calibrate KNHANES HDL-C data or not for each study.


Assuntos
HDL-Colesterol/sangue , Inquéritos Nutricionais , Algoritmos , Calibragem , HDL-Colesterol/normas , Humanos , Valores de Referência , República da Coreia
9.
Ann Lab Med ; 37(1): 34-38, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27834063

RESUMO

BACKGROUND: The associations of vitamin D deficiency with various clinical conditions highlighted the importance of vitamin D testing. Currently, clinicians measure only the total 25-hydroxyvitamin D [25(OH)D] concentration, regardless of its bioavailability. We aimed to determine the effect of vitamin D-binding protein (VDBP) on 25(OH)D bioavailability. METHODS: Serum samples were collected from 60 healthy controls, 50 pregnant women, and 50 patients in intensive care units (ICUs). Total 25(OH)D was quantified by liquid chromatography with tandem mass spectrometry, and VDBP levels were determined by using an ELISA kit (R&D Systems, USA). The bioavailable 25(OH)D levels were calculated by using total 25(OH)D, VDBP, and albumin concentrations. RESULTS: In comparison with healthy controls, the total 25(OH)D concentration was significantly lower in ICU patients (median, 11.65 vs 18.25 ng/mL; P<0.00001), but no significant difference was noted between pregnant women (18.25 ng/mL) and healthy controls. The VDBP level was significantly lower in ICU patients (95.58 vs 167.18 µg/mL, P=0.0002) and higher in pregnant women (225.01 vs 167.18 µg/mL, P=0.008) compared with healthy controls. Nonetheless, the calculated bioavailable 25(OH)D levels of ICU patients and pregnant women were significantly lower than those of healthy controls (1.97 and 1.93 ng/mL vs 2.56 ng/mL; P=0.0073 and 0.0027). CONCLUSIONS: A single marker of the total 25(OH)D level is not sufficient to accurately evaluate vitamin D status, especially in pregnant women. In cases where VDBP concentrations may be altered, VDBP measurements and bioavailable 25(OH)D calculations may help to determine vitamin D status accurately.


Assuntos
Proteína de Ligação a Vitamina D/sangue , Vitamina D/sangue , Adulto , Idoso , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Gravidez , Gestantes , Albumina Sérica/análise , Espectrometria de Massas em Tandem
10.
Clin Chim Acta ; 464: 1-5, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27823950

RESUMO

BACKGROUND: Since the 99th percentile reference limit for cardiac troponin (Tn) can vary depending on the reference population, Sandoval et al. published systematic selection criteria. In this study, these systematic criteria were applied for the first time to obtain the 99th percentile reference limits for 6 Tn tests. METHODS: The reference population was selected in accordance with the systematic criteria, and reference limits were set with respect to the six types of Tn assays. The coefficient of variation (CV) at the reference limit was determined using 3-4 concentrations of frozen serum. RESULTS: In total, 641 South Koreans (303 males, 338 females) were selected as the reference population. The 99th percentile reference limit of Tn in the six assays ranged from 13.4 to 34.2pg/ml. The measurable fractions among the reference population ranged from 1.3% to 80.5%. The CVs at the reference limit ranged from 5.3% to 43.0%, and three were <10%. CONCLUSIONS: In this study, a reference population was selected for the first time in accordance with the systematic criteria of Sandoval et al., and the reference limit for South Koreans was established. The values obtained in this study are different from those proposed by manufacturers, which confirms the importance of having a reference population. Four out of six assays did not fulfill the criteria for high-sensitivity tests.


Assuntos
Análise Química do Sangue/normas , Miocárdio/metabolismo , Seleção de Pacientes , Troponina/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
11.
Sci Rep ; 6: 34257, 2016 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-27698484

RESUMO

The functionality and viability of stored human red blood cells (RBCs) is an important clinical issue in transfusions. To systematically investigate changes in stored whole blood, the hematological properties of individual RBCs were quantified in blood samples stored for various periods with and without a preservation solution called citrate phosphate dextrose adenine-1 (CPDA-1). With 3-D quantitative phase imaging techniques, the optical measurements for 3-D refractive index (RI) distributions and membrane fluctuations were done at the individual cell level. From the optical measurements, the morphological (volume, surface area and sphericity), biochemical (hemoglobin content and concentration), and mechanical parameters (dynamic membrane fluctuation) were simultaneously quantified to investigate the functionalities and progressive alterations of stored RBCs. Our results show that stored RBCs without CPDA-1 had a dramatic morphological transformation from discocytes to spherocytes within two weeks which was accompanied by significant decreases in cell deformability and cell surface area, and increases in sphericity. However, the stored RBCs with CPDA-1 maintained their morphology and deformability for up to 6 weeks.


Assuntos
Preservação de Sangue/métodos , Deformação Eritrocítica , Transfusão de Sangue , Citratos/administração & dosagem , Glucose/administração & dosagem , Hemoglobinas/metabolismo , Humanos
12.
Ann Lab Med ; 36(6): 521-8, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27578504

RESUMO

BACKGROUND: Estimated glomerular filtration rate (eGFR) is a widely used index of kidney function. Recently, new formulas such as the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations or the Lund-Malmö equation were introduced for assessing eGFR. We compared them with the Modification of Diet in Renal Disease (MDRD) Study equation in the Korean adult population. METHODS: The study population comprised 1,482 individuals (median age 51 [42-59] yr, 48.9% males) who received annual physical check-ups during the year 2014. Serum creatinine (Cr) and cystatin C (CysC) were measured. We conducted a retrospective analysis using five GFR estimating equations (MDRD Study, revised Lund-Malmö, and Cr and/or CysC-based CKD-EPI equations). Reduced GFR was defined as eGFR <60 mL/min/1.73 m². RESULTS: For the GFR category distribution, large discrepancies were observed depending on the equation used; category G1 (≥90 mL/min/1.73 m²) ranged from 7.4-81.8%. Compared with the MDRD Study equation, the other four equations overestimated GFR, and CysC-based equations showed a greater difference (-31.3 for CKD-EPI(CysC) and -20.5 for CKD-EPI(Cr-CysC)). CysC-based equations decreased the prevalence of reduced GFR by one third (9.4% in the MDRD Study and 2.4% in CKD-EPI(CysC)). CONCLUSIONS: Our data shows that there are remarkable differences in eGFR assessment in the Korean population depending on the equation used, especially in normal or mildly decreased categories. Further prospective studies are necessary in various clinical settings.


Assuntos
Algoritmos , Taxa de Filtração Glomerular/fisiologia , Adulto , Idoso , Creatinina/sangue , Cistatina C/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos
13.
Ann Clin Lab Sci ; 46(4): 435-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27466307

RESUMO

Mixed phenotype acute leukemia (MPAL) includes biphenotypic leukemia, bilineal leukemia, or its combination by the 2008 WHO classification. A few cases of combined biphenotypic/bilineal MPAL have been reported so far; they all had biphenotypic expressions in only one of the two distinct leukemic populations. A 43-year-old female presented with leukocytosis and bicytopenia. Her complete blood counts were: hemoglobin, 6.9 g/dL; white blood cells, 62.8×10(9)/L; and platelets, 83×10(9)/L. Neither lymphadenopathy nor organomegaly was observed. Blasts and promonocytes/monoblasts were increased in her peripheral blood (42%) and bone marrow (60.1%). Flow cytometric analysis revealed two distinct populations of leukemic cells, which expressed CD11c, CD19, and cytoplasmic CD79a in common. Additionally, the first population expressed CD10 and CD117 (B/myeloid), and the second one expressed CD14 and CD20 (B/monocytic). She had a karyotype of 46,XX,inv(9)(p12q13),t(9;22)(q34;q11.2)[20] and BCR/ABL1 rearrangement. To the best of our knowledge, this is the first reported case of biphenotypic/bilineal MPAL with B/myeloid and B/monocytic expressions.


Assuntos
Cromossomos Humanos Par 22/genética , Cromossomos Humanos Par 9/genética , Proteínas de Fusão bcr-abl/genética , Leucemia/genética , Leucemia/patologia , Monócitos/patologia , Células Mieloides/patologia , Translocação Genética , Adulto , Feminino , Citometria de Fluxo , Humanos , Fenótipo
14.
Ann Clin Lab Sci ; 46(3): 308-11, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27312558

RESUMO

At diagnosis, fewer than 10% of chronic myelogenous leukemia (CML) patients have additional cytogenetic abnormalities (ACAs), which are frequently found in transformation to blast crisis. We report a case of CML-chronic phase (CML-CP) that showed t(1;15) at diagnosis. A 64-year-old man presented with sustained leukocytosis and thrombocytosis. His bone marrow (BM) was hypercellular with 2.5% blasts and BCR-ABL1 rearrangement. The karyotype in the BM was 46,XY,t(1;15)(q32;p13),t(9;22)(q34;q11.2)[20], while the karyotype in the peripheral blood was 46,XY[20]. This is the first report on the presence of t(1;15) at diagnosis of CML-CP, and its clinical significance remains unclear.


Assuntos
Aberrações Cromossômicas , Cromossomos Humanos Par 15/genética , Cromossomos Humanos Par 1/genética , Leucemia Mielogênica Crônica BCR-ABL Positiva/diagnóstico , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Translocação Genética , Humanos , Cariotipagem , Masculino , Pessoa de Meia-Idade
16.
Clin Biochem ; 49(10-11): 756-61, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27067595

RESUMO

OBJECTIVES: This study aimed to determine the 99th percentile upper reference limit (URL) concentration of cardiac troponin I (cTnI) with a high-sensitivity assay in a Korean population. DESIGN AND METHODS: Cardio-healthy males and females were enrolled between March 2014 and March 2015. Participants with possible subclinical conditions were excluded on the basis of laboratory measures (primary: estimated glomerular filtration rate and glycated hemoglobin; secondary: B-type natriuretic peptide). Serum cTnI was measured using ARCHITECT STAT High-Sensitive Troponin-I Assay (Abbott Diagnostics, USA). RESULTS: A total of 1204 participants completed a self-reporting questionnaire for inclusion in the study. Of these, we excluded 349 (29.0%) participants on the basis of primary (n=283) and secondary (n=66) laboratory measures. Ultimately, we included 854 participants (mean age, 49.8±10.2years) in the final analysis. The 99th percentiles of cTnI concentrations were 18 (90% confidence interval [CI], 14-35) ng/L for all participants, 20 (90% CI, 15-69) ng/L for males and 19 (90% CI, 11-41) ng/L for females. In both males and females, the median cTnI concentrations were significantly higher in participants aged 50years and older than in those younger than 50years old. CONCLUSIONS: In this study, the reference population with Korean ethnicity had lower overall and male 99th percentile URLs than other reference populations. Our data suggest that 99th percentile URLs may be influenced by factors such as ethnicity, age distribution of participants, and selection criteria used to define a healthy reference population.


Assuntos
Biomarcadores/sangue , Doenças Cardiovasculares/diagnóstico , Imunoensaio/métodos , Troponina I/sangue , Troponina T/sangue , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/sangue , Feminino , Seguimentos , Humanos , Laboratórios , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Prognóstico , Curva ROC , Valores de Referência , Adulto Jovem
17.
Scand J Clin Lab Invest ; 76(3): 256-63, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26963924

RESUMO

INTRODUCTION: The results of urine sediment analysis have been reported semiquantitatively. However, as recent guidelines recommend quantitative reporting of urine sediment, and with the development of automated urine sediment analyzers, there is an increasing need for quantitative analysis of urine sediment. Here, we developed a protocol for urine sediment analysis and quantified the results. METHODS: Based on questionnaires, various reports, guidelines, and experimental results, we developed a protocol for urine sediment analysis. The results of this new protocol were compared with those obtained with a standardized chamber and an automated sediment analyzer. Reference intervals were also estimated using new protocol. RESULTS: We developed a protocol with centrifugation at 400 g for 5 min, with the average concentration factor of 30. The correlation between quantitative results of urine sediment analysis, the standardized chamber, and the automated sediment analyzer were generally good. The conversion factor derived from the new protocol showed a better fit with the results of manual count than the default conversion factor in the automated sediment analyzer. CONCLUSIONS: We developed a protocol for manual urine sediment analysis to quantitatively report the results. This protocol may provide a mean for standardization of urine sediment analysis.


Assuntos
Urinálise/métodos , Centrifugação , Serviços de Laboratório Clínico , Humanos , Guias de Prática Clínica como Assunto , Padrões de Referência , Valores de Referência , Urinálise/normas
18.
J Korean Med Sci ; 31(2): 310-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26839488

RESUMO

CYP2D6 is primarily responsible for the metabolism of clomiphene citrate (CC). The purpose of the present study was to investigate the relationship between CYP2D6 genotypes, concentrations of CC and its major metabolites and drug response in infertility patients. We studied 42 patients with ovulatory dysfunction treated with only CC. Patients received a dose of 100 mg/day CC on days 3-7 of the menstrual cycle. CYP2D6 genotyping and measurement of CC and the major metabolite concentrations were performed. Patients were categorized into CC responders or non-responders according to one cycle response for the ovulation. Thirty-two patients were CC responders and 10 patients were non-responders with 1 cycle treatment. The CC concentrations were highly variable within the same group, but non-responders revealed significantly lower (E)-clomiphene concentration and a trend of decreased concentrations of active metabolites compared to the responders. Nine patients with intermediate metabolizer phenotype were all responders. We confirmed that the CC and the metabolite concentrations were different according to the ovulation status. However, our results do not provide evidence for the contribution of CYP2D6 polymorphism to either drug response or CC concentrations.


Assuntos
Clomifeno/uso terapêutico , Citocromo P-450 CYP2D6/genética , Infertilidade/tratamento farmacológico , Polimorfismo Genético , Adulto , Cromatografia Líquida de Alta Pressão , Clomifeno/sangue , Clomifeno/metabolismo , Antagonistas de Estrogênios/análise , Antagonistas de Estrogênios/metabolismo , Antagonistas de Estrogênios/uso terapêutico , Feminino , Genótipo , Humanos , Infertilidade/genética , Indução da Ovulação , Fenótipo , República da Coreia , Espectrometria de Massas em Tandem
19.
J Clin Lab Anal ; 30(5): 485-9, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26499918

RESUMO

BACKGROUND: Vancomycin is the treatment of choice for serious methicillin-resistant Staphylococcus aureus (MRSA) infections. The area under the concentration-time curve from 0 to 24 hr (AUC24 )/minimum inhibitory concentration (MIC) ratio was recently introduced as a parameter for assessing clinical outcome by S. aureus. This study was purposed to apply the vancomycin AUC24 /MIC in patients with MRSA pneumonia. METHODS: Forty-seven patients with confirmed lower respiratory infection caused by MRSA during 2011 were enrolled. All patients were treated with vancomycin. Clinical characteristics and laboratory data were collected. AUC24 /MIC values were calculated as previously reported and patients were divided into two groups based on the bacteriologic response, which was eradicated or not, and an AUC24 /MIC value (above or below 400). RESULTS: MRSA infections were eradicated in 39 patients but 8 patients had persistent MSRA infection in the following cultures. The mean AUC24 /MIC values and vancomycin concentrations were not statistically different between patients with and without MRSA eradication. All 13 patients with a vancomycin MIC of 2 mg/L had an AUC24 /MIC below 400. CONCLUSION: AUC24 /MIC might not be a reliable indicator for assessing treatment response of vancomycin in MRSA pneumonia. Relationship between vancomycin AUC24 /MIC and therapeutic outcome needs to undergo further studies, including sufficiently large sample size.


Assuntos
Antibacterianos/uso terapêutico , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Staphylococcus aureus Resistente à Meticilina/metabolismo , Vancomicina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/sangue , Área Sob a Curva , Farmacorresistência Bacteriana , Feminino , Humanos , Masculino , Meticilina/efeitos adversos , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Estudos Retrospectivos , Estatísticas não Paramétricas , Vancomicina/sangue , Adulto Jovem
20.
J Korean Med Sci ; 30(11): 1698-700, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26539017

RESUMO

Acute cholecystitis is a rare complication of scrub typhus. Although a few such cases have been reported in patients with scrub typhus, the clinical course is not well described. Of 12 patients, acute cholecystitis developed in 66.7% (8/12) of patients older than 60 yr. The scrub typhus group with acute cholecystitis had marginal significant longer hospital stay and higher cost than the group without cholecystitis according to propensity score matching. Scrub typhus should be kept in mind as a rare etiology of acute cholecystitis in endemic areas because the typical signs of scrub typhus such as skin rash and eschar can present after the abdominal pain.


Assuntos
Colecistite Aguda/diagnóstico , Colecistite Aguda/etiologia , Tifo por Ácaros/complicações , Tifo por Ácaros/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Colecistite Aguda/terapia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , República da Coreia , Tifo por Ácaros/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA