Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Sci Data ; 11(1): 379, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38615072

RESUMO

Electroencephalography (EEG) microstate analysis is a neuroimaging analytical method that has received considerable attention in recent years and is widely used for analysing EEG signals. EEG is easily influenced by internal and external factors, which can affect the repeatability and stability of EEG microstate analysis. However, there have been few reports and publicly available datasets on the repeatability of EEG microstate analysis. In the current study, a 39-year-old healthy male underwent a total of 60 simultaneous electroencephalography and electrocardiogram measurements over a period of three months. After the EEG recording was completed, magnetic resonance imaging (MRI) was also conducted. To date, this EEG dataset has the highest number of repeated measurements for one individual. The dataset can be used to assess the stability and repeatability of EEG microstates and other analytical methods, to decode resting EEG states among subjects with open eyes, and to explore the stability and repeatability of cortical spatiotemporal dynamics through source analysis with individual MRI.


Assuntos
Eletroencefalografia , Adulto , Humanos , Masculino , Eletrocardiografia , Neuroimagem
2.
MethodsX ; 12: 102700, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38633419

RESUMO

Interstitial fluid, owing to its similarity to blood components and higher sensitivity and specificity, finds widespread application in disease diagnosis and tumor marker detection. However, collecting interstitial fluid, particularly from the deep subcutaneous connective tissue, remains challenging.•This study aimed to compare three different collection methods - push-pull perfusion, multi-filament nylon thread implantation, and tissue centrifugation - for collecting interstitial fluid from the subcutaneous connective tissue layer of mini-pigs. High-performance ion chromatography was employed to analyze the conventional cation components in the samples and compare ion composition analysis between the different methods.•Results indicated that while the distribution of conventional cations in the interstitial fluid collected by the three methods was generally consistent, there were slight variations in the detection rates and concentrations of different ions. Hence, suitable collection methods should be selected based on the ions or collection sites of interest.

3.
Phys Chem Chem Phys ; 26(12): 9096-9111, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38456310

RESUMO

As one of the most promising energy storage devices, supercapacitors exhibit a higher power density than batteries. However, its low energy density usually requires high-performance electrode materials. Although the RuO2 material shows desirable properties, its high cost and toxicity significantly limit its application in supercapacitors. Recent developments demonstrated that Co-based materials have emerged as a promising alternative to RuO2 for supercapacitors due to their low cost, favorable redox reversibility and environmental friendliness. In this paper, the morphological control and performance engineering of Co-based materials are systematically reviewed. Firstly, the principle of supercapacitors is briefly introduced, and the characteristics and advantages of pseudocapacitors are emphasized. The special forms of cobalt-based materials are introduced, including 1D, 2D and 3D nanomaterials. After that, the ways to enhance the properties of cobalt-based materials are discussed, including adding conductive materials, constructing heterostructures and doping heteroatoms. Particularly, the influence of morphological control and modification methods on the electrochemical performances of materials is highlighted. Finally, the application prospect and development direction of Co-based materials are proposed.

4.
Quant Imaging Med Surg ; 13(10): 6434-6445, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37869294

RESUMO

Background: Visually evaluating liver function is a hot topic in hepatology research. There are few reliable and practical visualization methods for evaluating the liver function in vivo in experimental studies. In this study, we established a multimodal imaging approach for in vivo liver function evaluation and compared healthy mice with chronic alcoholic liver injury (cALI) model mice to explore its potential applicability in experimental research. Methods: In vivo fluorescence imaging (IVFI) technology was utilized to visually represent the clearance of indocyanine green from the liver of both healthy mice and mice with cALI. The reserve liver function was evaluated via IVFI using the Cy5.5-galactosylated polylysine probe, which targets the asialoglycoprotein receptor of hepatocytes. Hepatic microcirculation was assessed through laser speckle perfusion imaging of hepatic blood perfusion. The liver microstructure was then investigated by in vivo confocal laser endomicroscopy imaging. Finally, hepatic asialoglycoprotein receptor expression, histology, and the levels of serum alanine aminotransferase and aspartate aminotransferase were measured. Results: In vivo multimodal imaging results intuitively and dynamically showed that indocyanine green clearance [mean ± standard deviation (SD): 30.83±14.71, 95% confidence interval (CI): 20.3 to 41.35], the fluorescence signal intensity (mean ± SD: 1,217.92±117.63; 95% CI: 1,148.38 to 1,290.84) and fluorescence aggregation area (mean ± SD: 5,855.80±1,271.81; 95% CI: 5,051.57 to 6,653.88) of Cy5.5-galactosylated polylysine targeting the asialoglycoprotein receptor, and hepatic blood perfusion (mean ± SD: 1,494.86±299.33; 95% CI: 1,316.98 to 1,690.16) in model mice were significantly lower than those in healthy mice (all P<0.001). Compared to healthy mice, the model mice exhibited a significant decline in liver asialoglycoprotein receptor expression (mean ± SD: 219.03±16.34; 95% CI: 208.97 to 230.69; P<0.001), increased serum alanine aminotransferase (mean ± SD: 149.70±47.89 U/L; 95% CI: 81.75 to 128.89; P=0.01) and aspartate aminotransferase levels (mean ± SD: 106.30±36.13 U/L; 95% CI: 122.01 to 180.17; P=0.021), hepatocyte swelling and deformation, disappearance of the hepatic cord structure, partial necrosis, and disintegration of hepatocytes. The imaging features of fluorescence signals in liver regions, hepatic blood perfusion and microstructure were biologically related to hepatic asialoglycoprotein receptor expression, serum indices of liver function, and histopathology in model mice. Conclusions: Utilizing in vivo multimodal imaging technology to assess liver function is a viable approach for experimental research, providing dynamic and intuitive visual evaluations in a rapid manner.

5.
J Acupunct Meridian Stud ; 16(3): 101-108, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37381032

RESUMO

Background: The biophysical properties of the meridian system, an important concept of traditional Chinese medicine, include low impedance, resounding voice, and high acoustic conductance, all of which are helpful for elucidating the essence of meridians. Objectives: To visualize the human pericardium meridian (PC) based on the resounding voice property of meridians. Methods: Visualization of the PC was performed by injection of fluorescein sodium at the PC6 acupoint (Neiguan) on the PC. Before injection, percussion active points (PAPs) were identified by the virtue of their resounding voice properties. After injection, the trajectories of fluorescein migration throughout the body surface were recorded and analyzed. The distribution of fluorescein in the tissue was further studied using cross-sections of hind limbs of mini-pigs, in which fluorescein was injected into low impedance points. Results: The identified PAP lines were colocalized with PC. Following intradermal fluorescein injection, 1-3 fluorescent lines, which were unrelated to the arm veins, were observed in 7 of 10 participants; 85.4% of fluorescent signals were coincident with PAPs and their intensity had a negative correlation with the body mass index (r = -0.56, p = 0.045). Cross-sections showed a Y-shaped fluorescence pattern where the two migration lines on the surface were the two vertices of the "Y." Conclusion: The trajectories of fluorescein in the body are suggestive of the anatomical structure of meridians. The PC is related to the deep horizontal interstitial channels that connect to the body surface through vertical interstitial spaces. These biophysical properties and techniques for meridian visualization are valuable for revealing the anatomical structure of meridians.


Assuntos
Meridianos , Animais , Humanos , Suínos , Porco Miniatura , Pontos de Acupuntura , Índice de Massa Corporal , Fluoresceína
6.
Mikrochim Acta ; 190(5): 180, 2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37043083

RESUMO

A one-step electrodeposition-assisted self-assembly technique has been developed for preparation of ZnTCPP@MOF films with three-dimensional mesoporous structure in a three-electrode system. The internal structure of the ZnTCPP@MOF films was tuned by adjusting the electrochemical deposition voltage, deposition time, and the concentration of ZnTCPP at room temperature. The ZnTCPP@MOF films under different deposition conditions were characterized by scanning electron microscopy, Fourier transformation infrared spectroscopy, and X-ray photoelectron spectroscopy. The prepared ZnTCPP@MOF films exhibited excellent fluorescence properties, in which ZnTCPP molecules were encapsulated inside the MOF as fluorescent signal probes and structure-directing agents, which affected the electrochemical response of the ZnTCPP@MOF films. The sensing platform based on ZnTCPP@MOF film was used to detect microcystin with a wide determination range (1.0 × 10-12 mol/L ~ 1.0 × 10-5 mol/L), low determination limit (3.8 × 10-13 mol/L), and high sensitivity. More importantly, the strategy is simple, low-cost, green, and environmentally friendly, and it provides a new strategy for the direct use of MOFs films as signaling components.

7.
Small ; 19(19): e2207562, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36799138

RESUMO

Na3 V2 (PO4 )2 F3 (NVPF) is a suitable cathode for sodium-ion batteries owing to its stable structure. However, the large radius of Na+ restricts diffusion kinetics during charging and discharging. Thus, in this study, a phosphomolybdic acid (PMA)-assisted hydrothermal method is proposed. In the hydrothermal process, the NVPF morphologies vary from bulk to cuboid with varying PMA contents. The optimal channel for accelerated Na+ transmission is obtained by cuboid NVPF. With nitrogen-doping of carbon, the conductivity of NVPF is further enhanced. Combined with crystal growth engineering and surface modification, the optimal nitrogen-doped carbon-covered NVPF cuboid (c-NVPF@NC) exhibits a high initial discharge capacity of 121 mAh g-1 at 0.2 C. Coupled with a commercial hard carbon (CHC) anode, the c-NVPF@NC||CHC full battery delivers 118 mAh g-1 at 0.2 C, thereby achieving a high energy density of 450 Wh kg-1 . Therefore, this work provides a novel strategy for boosting electrochemical performance by crystal growth engineering and surface modification.

8.
Sci Rep ; 13(1): 1586, 2023 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-36709364

RESUMO

Skin blood flux (SkBF) changes caused by drinking cold water are generally associated with vagal tone and osmotic factors in the digestive system. However, there is still a lack of relevant research on whether there are left and right differences in these SkBF change. In the current study, a total of 60 subjects were recruited. Skin blood perfusion of the bilateral lower extremities was recorded simultaneously before and after drinking saline of different temperatures saline by using Laser Doppler flowmetry (LDF). The electrogastrogram (EGG) was also monitored, and the dominant frequency of the EGG and heart rate variability were analyzed. The results indicated that after drinking saline, the laterality index of SkBF at the lower extremities was different and the laterality index changes of SkBF were mainly reflected in the frequency interval V (0.4-1.6 Hz). There was a weak negative correlation between the laterality index of endothelial NO-dependent component and change rate of root mean square of successive differences (RMSSD) after drinking 4 °C saline. However, after drinking 30 °C saline, there was a weak positive correlation between neurogenic component and RMSSD The distribution and regulation of bilateral blood flow are not symmetrical but exhibit a certain laterality.


Assuntos
Extremidade Inferior , Pele , Humanos , Temperatura , Fluxo Sanguíneo Regional/fisiologia , Pele/irrigação sanguínea , Fluxometria por Laser-Doppler , Perfusão
9.
Acupunct Med ; 41(4): 215-223, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36263700

RESUMO

OBJECTIVE: Acupuncture can improve the symptoms of alcohol-induced bodily injury and has been accepted by the World Health Organization. In this study, in vivo fluorescence imaging (IVFI) was applied to display and evaluate the effect of electroacupuncture (EA) on liver function (LF) in mice with chronic alcoholic liver injury (cALI). METHODS: IVFI of the Cy5.5-galactosylated polylysine (Cy5.5-GP) probe targeting the liver asialoglycoprotein receptor (ASGPR) and liver indocyanine green (ICG) clearance was performed to visually evaluate the effect of EA at ST36 and BL18 on liver reserve function and hepatic metabolism in mice with cALI. In addition, changes in ASGPR expression, serum indexes of LF, and hepatic morphology were observed. RESULTS: After EA at ST36 and BL18, the ASGPR-targeted fluorescence signals (FS) in the liver increased significantly in cALI mice (p < 0.05) and exhibited relationships with liver ASGPR expression, liver ICG clearance, liver histology, and serum marker levels of LF in cALI mice undergoing EA intervention. CONCLUSIONS: As displayed by IVFI, EA at ST36 and BL18 appears to improve liver reserve function and inhibit the development of liver injury in mice with cALI. EA may have potential as a treatment strategy to protect against ALI.


Assuntos
Eletroacupuntura , Camundongos , Animais , Pontos de Acupuntura , Fígado/diagnóstico por imagem , Fígado/metabolismo , Imagem Óptica
10.
Zhen Ci Yan Jiu ; 47(6): 549-52, 2022 Jun 25.
Artigo em Chinês | MEDLINE | ID: mdl-35764524

RESUMO

This paper introduced the research ideas and methods for the development of the national standard, "Pure moxa stick". According to the orientation of product standard and related documents, on the basis of extensive investigation and in consultation with manufacturers and experts, the problems encountered in this standard development were solved. The general technical requirements were specified in association with the basic experimental data. The technical requirements should not only conform to the current technological status of moxa sticks production, but also present a certain of innovation. The innovation of this standard lies in the concepts of the ratio of leaves to floss, the ratio of whole plant to floss, density, etc. Besides, the main technical requirements of "Pure moxa stick" have been specified, i.e. material, shape and structure, combustion characteristics, physical and chemical characteristics. The development of national standard "Pure moxa stick" contributes to the favorable exploration and practice of the standardization of traditional Chinese medicine and provides the effective reference for the further stan-dardization of acupuncture and moxibustion.


Assuntos
Terapia por Acupuntura , Moxibustão , Medicina Tradicional Chinesa
11.
Artigo em Inglês | MEDLINE | ID: mdl-34868329

RESUMO

Acupuncture and moxibustion are widely used in clinical practice; however, the differences between their mechanisms are unclear. In the present study, the response of blood perfusion resulting from acupuncture or moxibustion at Ximen (PC4) and its surrounding points was explored. Using the wavelet method, the differences in the frequency interval of blood flux were observed. Furthermore, the correlations between these points were analyzed. The results suggested that moxibustion could significantly improve blood flow perfusion at PC4 compared to acupuncture; however, there was no significant difference around PC4. The response of blood flux at PC4 to different stimulations was related to the frequency V (0.4-1.6 Hz) component. However, a difference in response at other points was not observed. Correlation analysis showed that both acupuncture and moxibustion could cause a decline in the correlation of blood flux signals at these recorded points, but there was no significant difference between these techniques. The results suggested that, at least in the forearm, the acupuncture or moxibustion only influenced the level of blood perfusion locally.

12.
Front Physiol ; 12: 656527, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34483950

RESUMO

Previous studies have explored the relationship between the complexity of local blood flow signals and heart rate variability (HRV) under different thermal stimulations. However, the relationship between the complexity of local blood flow signals and HRV in different positions is not clear. In this study, healthy participants were placed in different body positions. The bilateral blood flux and ECG were monitored, and refined composite multiscale entropy (RC MSE) and refined composite multiscale fuzzy entropy (RC MFE) were used to measure the complexity of the local blood flux. The sample entropy was calculated to evaluate the HRV complexity. The change of body position did not affect the time domain or frequency domain of HRV, but did reverse the blood flux laterality of the lower extremities. Furthermore, there was a negative correlation between the complexity of right-side blood flux and sample entropy of HRV when the participant was in the -10 degrees position. These results provide a new perspective of the relationship between skin blood flux signals and cardiac function.

13.
Artigo em Inglês | MEDLINE | ID: mdl-34035822

RESUMO

In more than half a century, exploring the biological connotation of the meridians was one of the core components of scientific research studies in traditional Chinese medicine (TCM). Based on the previous works of low hydraulic resistance channel (LHRC) along meridians (LHRCM), the differential proteomics between the Alcian blue track (ABT) on LHRC along the conception vessel (CV) and nonmeridians tissue next to the CV were investigated in this study to explore the material basis and biological function of LHRCM. Proteomics based on LC-MS was introduced into the subcutaneous connective tissues (SCT) of ABT along the CV and the adjacent nonmeridian (1 cm from the CV). A total of 2328 proteins were identified from ABT along the CV and adjacent nonmeridian based on data-dependent acquisition (DDA) mode. In total, 1970 proteins were quantified based on the SWATH (sequential window acquisition of all theoretical fragment ions) label-free model, and the nonstandard and quantitative methods of MSALL were applied to analyze the data. There were 468 proteins differentially expressed. GO analytic results showed that the differential proteins were of varieties in molecular function and biological process. Most of differential proteins were involved in metabolic process, cellular process, response to hormone, and response to wounding. Further analysis showed that the upregulated differential proteins involved in ATP metabolism (ATP5E, GAPDH), redox reactions (Gpx-3), and Ca2+ transmembrane transport (CACNA2D1) were closely related to meridian phenomenon and acupuncture effect. These differential proteins would be potential characteristic proteins of the LHRC along the CV in rats which may be useful to deepen the knowledge on LHRCM.

14.
Zhen Ci Yan Jiu ; 46(4): 289-94, 2021 Apr 25.
Artigo em Chinês | MEDLINE | ID: mdl-33931993

RESUMO

OBJECTIVE: To observe the effect of electroacupuncture (EA) on the hemorheology and hepatic microcirculation in mice with chronic alcoholic liver injury (cALI), so as to explore the microcirculation mechanism of EA underlying regulating liver function in cALI mice. METHODS: Forty Kunming mice were randomly assigned to control, model, acupoint EA and non-acupoint EA groups, with 10 mice in each group. The cALI model was established by gavage with 50% ethanol (15 mL/kg,2 times per day with 8 hours' interval) for 28 d. Mice in the acupoint EA group received EA at bilateral "Zusanli" (ST36) and "Ganshu"(GB11) for 20 min, once daily for 14 d. And mice in the non-acupoint EA group received EA the spot about 1 cm lateral to GB11 and 0.5 cm lateral to ST36 respectively for 20 min, once daily for 14 d. The hepatic blood perfusion (HBP) of mice was detected by laser speckle perfusion imaging. The index of hemorheology, serum markers of liver function and hepatic histology in mice were observed by automatic blood rheometer, automatic bio-analysis machine and H.E. staining, respectively. RESULTS: Compared with the control group, the HBP of the model group was significantly decreased (P<0.05); the low-cut whole blood viscosity, plasma viscosity, and erythrocyte sedimentation level were significantly increased (P<0.05), and the red blood cell deformation index was significantly decreased (P<0.05); serum alanine aminotransferase (ALT) and gamma-glutamyl transferase (GGT) increased significantly (P<0.05) in the model group. Hepatocyte steatosis accompanied by inflammatory cell infiltration and focal necrosis was observed in the model group. After EA at ST36 and GB11, and in comparison with the model group showed that the HBP was significantly increased (P<0.05); the low-cut whole blood viscosity, plasma viscosity, erythrocyte sedimentation rate and serum GGT were significantly decreased (P<0.05), and the red blood cell deformation index was significantly increased (P<0.05); the degree of fatty degeneration in the liver tissue was reduced, and the focal necrosis was reduced. The plasma viscosity, erythrocyte sedimentation rate were significantly decreased (P<0.05), and the red blood cell deformation index was significantly increased in the non-acupoint EA group relevant to the model group (P<0.05). The erythrocyte sedimentation rate and the red blood cell deformation index of the acupoint EA group was significantly lower than that of the non-acupoint EA group (P<0.05). CONCLUSION: EA at ST36 and GB11 could improve the hemorheological disorder and the hepatic microcirculation, and inhibit the deve-lopment of liver injury in cALI mice.


Assuntos
Eletroacupuntura , Pontos de Acupuntura , Animais , Hemorreologia , Fígado , Camundongos , Microcirculação , Ratos , Ratos Sprague-Dawley
15.
Sci Rep ; 10(1): 183, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31932611

RESUMO

The physiologically important relationship between oxygen saturation and blood flow is not entirely understood, particularly with regard to the multiple velocity components of flow and temperature. While our previous studies used classic laser Doppler flowmetry combined with an enhanced perfusion probe to assess local blood flow following thermal stimulation, oxygen saturation signals were not assessed. Thus, the current study used multiscale entropy (MSE) and multiscale fuzzy entropy (MFE) to measure the complexity of oxygen saturation signals following thermal stimulation in healthy subjects. The results indicate that thermal stimulation increases oxygen saturation and affects the measured signal complexity in a temperature-dependent fashion. Furthermore, stimulus temperature not only affects the correlation between speed-resolved blood perfusion and oxygen saturation, but also the correlation between the complexity area indices (CAI) of the two signals. These results reflect the complexity of local regulation and adaptation processes in response to stimuli at different temperatures.


Assuntos
Velocidade do Fluxo Sanguíneo , Antebraço/irrigação sanguínea , Oxigênio/metabolismo , Fluxo Sanguíneo Regional , Temperatura , Adolescente , Adulto , Entropia , Feminino , Hemodinâmica , Humanos , Fluxometria por Laser-Doppler , Masculino , Pessoa de Meia-Idade , Perfusão , Adulto Jovem
16.
Biomed Opt Express ; 10(10): 5015-5024, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31646026

RESUMO

The visual evaluation of liver function (LF) has always been a hot topic in research on liver diseases. In vivo fluorescence imaging (IVFI) of the Cy5.5-galactosylated polylysine (Cy5.5-GP) probe targeting asialoglycoprotein receptor (ASGPR), for evaluating LF in chronic alcoholic liver injury (cALI) mice was investigated in this study. The decrease of fluorescence signals in the livers showed a biological relationship with the liver ASGPR expression, histology, and serum marker levels of LF in cALI mice. The targeted IVFI of ASGPR as a novel method can intuitively and noninvasively display the characteristics of liver's ASGPR level to provide a reference for evaluating LF.

17.
PLoS One ; 14(6): e0217973, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31167001

RESUMO

Our previous study employed the classic laser Doppler flux (LDF) to explore the complexity of local blood flow signals and their relationship with heart rate variability (HRV). However, microcirculation blood flow is composed of different velocity components. To investigate the complexity of local speed-resolved perfusion and HRV following stimulation with different temperatures in healthy subjects, multiscale entropy (MSE) and multiscale fuzzy entropy (MFE) were used to measure the complexity of local speed-resolved perfusion signals. MSE was also used to evaluate the complexity of HRV. The results indicated that thermal stimulation increased all components of local speed-resolved perfusion and that stimulation with different temperatures resulted in different changes in the complexity area index. However, the same stimulation had no effect on the MSE of HRV. Further research showed that 44°C thermal stimulation resulted in a weak correlation between the composite speed-resolved perfusion and the HRV complexity. The current study provides a new approach for studying the relationship between speed-resolved perfusion signals and cardiac function.


Assuntos
Entropia , Lógica Fuzzy , Frequência Cardíaca/fisiologia , Perfusão , Fluxo Sanguíneo Regional/fisiologia , Temperatura , Adulto , Feminino , Humanos , Masculino
18.
Sci Rep ; 8(1): 10753, 2018 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-29993028

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

19.
Sci Rep ; 8(1): 8982, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29895975

RESUMO

To investigate the relationship between local blood flux and heart rate variability following different thermal stimulations, healthy subjects were recruited and subject to different thermal stimulations on the right forearm. Multiscale entropy and multiscale fuzzy entropy were used to measure the complexity of the local blood flux, and the approximate entropy was calculated to evaluate the HRV complexity. The results indicated that thermal stimulation significantly increased local blood flux and that different temperature stimulations resulted in different complexities in local blood flux. A 42 °C or 44 °C thermal stimulation, other than stimulations below 42 °C, resulted in a moderate correlation between local blood flux and heart rate variability complexity. The results provide a new perspective in terms of complexity to explore the relationship between skin blood flux signals and cardiac function.


Assuntos
Antebraço/irrigação sanguínea , Frequência Cardíaca , Temperatura Alta , Modelos Cardiovasculares , Transdução de Sinais , Pele/irrigação sanguínea , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Entropia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Artigo em Inglês | MEDLINE | ID: mdl-28811830

RESUMO

Acupuncture (Acup) and moxibustion (Moxi) are commonly used interventions in clinical practice. However, the difference between Acup and moxibustion mechanisms is unclear. In current study, blood perfusion responses resulted from Acup or Moxi at Weishu acupoint (BL21) and control points were explored, respectively. The time series of blood flux signals at BL21 and control points were transformed with Morlet wavelet, and the differences in each frequency interval were observed. The results suggested that acupoint response to different stimulation is a comprehensive process which related to all components of blood perfusion signals. Whereas the different response at control points was not observed, there has been significant difference coherence value between Acup and Moxi stimulation. The results suggested the influence of Acup and Moxi not only on the level of blood perfusion at local area; the intrinsic relevance after stimulation which can be evaluated by coherence analysis is also an appropriate index to distinguish different stimulations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA