Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Abdom Radiol (NY) ; 47(2): 586-595, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757459

RESUMO

PURPOSE: To compare detection rates of NET liver metastases of MRI and Ga-68-DOTATATE PET/CT to provide more clarity when selecting diagnostic imaging tests for NET staging. METHODS: In this IRB-approved single-institution retrospective study, all patients with pathology-proven NET who underwent Ga-68-DOTATATE and MRI scans within 8 weeks of each other (3/2017-2/2020) were reviewed. Number of metastases for each patient on diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) MRI, and Ga-68 DOTATATE were recorded by two blinded radiologists, followed by consensus review with two separate blinded readers for MRI and nuclear medicine. Per-lesion and -modality scoring at each lesion location were then performed in consensus. Per-patient linear regression was performed comparing MRI and Ga-68 DOTATATE detection rates for each reader and in consensus, and per-lesion-matched pair difference means were used to compare detection frequency between modalities. RESULTS: 32 patients (mean age 59 years, 59.4% male) and 90 liver metastases were analyzed. Intraclass coefficients (ICC) [95% CI] between the two readers were 0.97 [0.95, 0.99], 0.89 [0.82, 0.94], and 0.98 [0.97, 0.99] for Ga-68 DOTATATE, DWI, and DCE, respectively. Matched per-lesion mean differences were + 0.17 ± 0.07 (p = 0.01) and + 0.22 ± 0.06 (p = < 0.001) for DWI versus Ga-68 DOTATATE and DCE vs Ga-68 DOTATATE, respectively, favoring MRI. Case-based linear regressions estimate that DWI and DCE detect 1.28 [1.07, 1.49] and 1.33 [1.12, 1.54] lesions, respectively, for each one detected on Ga-68 DOTATATE. CONCLUSION: MRI detects more hepatic NET metastasis in comparison to Ga-68 DOTATATE. Liver MRI should be performed in concert with Ga-68 DOTATATE in NET staging.


Assuntos
Neoplasias Hepáticas , Tumores Neuroendócrinos , Compostos Organometálicos , Feminino , Radioisótopos de Gálio , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Cintilografia , Estudos Retrospectivos
2.
Eur J Radiol ; 143: 109886, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34412010

RESUMO

PURPOSE: Assess and compare the quality and diagnostic performance of CCTA between pre-liver and pre-kidney transplant patients, and gauge impact of CCTA on ICA requirements. METHODS: Patients without known coronary artery disease (CAD) were selected for CCTA if considered high-risk or after abnormal stress testing. All pre-liver and pre-kidney CCTAs between March 2018 and August 2020 were retrospectively included. CCTA quality was qualitatively graded as excellent/good/fair/poor, and CAD graded as < or ≥50% stenosis. Heart rate, coronary artery calcium (CAC) scores, and fractional flow reserve CT (FFRCT) results were collected. CAD stenosis was graded on invasive coronary angiogram (ICA) images, with ≥50% stenosis defined as significant. RESULTS: 162 pre-transplant patients (91 pre-liver, 71 pre-kidney). Pre-kidney patients had poorer CCTA quality (p = 0.04) and higher heart rate (median: 65 bpm vs 60 bpm, p < 0.001). Out of 147 diagnostic CCTAs (pre-liver: 84, pre-kidney: 63), 73 (49.7%) had a ≥50% stenosis (pre-liver: 38 (45.2%), pre-kidney:35 (55.6%)). 12/38 (31.6%) had a significantly reduced FFRCT, and 19/53 (35.8%) had ≥50% stenosis on ICA. Among patients whose CCTA was diagnostic and had ICA, stenosis severity was concordant in 10/23 (43.5%) pre-liver and 10/25 (40%) pre-kidney patients. All discordant cases had stenosis 'over-called' on CCTA. CONCLUSION: Diagnostic-quality CCTAs in high-risk pre-transplant patients are achievable and can greatly reduce ICA requirements by excluding significant CAD. CCTA quality is poorer in pre-kidney transplant patients compared to pre-liver, possibly due to higher heart rate.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Transplante de Rim , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Fígado , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
3.
J Am Coll Radiol ; 14(1): 57-64, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27692807

RESUMO

PURPOSE: To determine the value of image-rich radiology reports (IRRR) by evaluating the interest and preferences of referring physicians, potential impact on clinical workflow, and the willingness of radiologists to create them. METHODS: Referring physicians and radiologists were interviewed in this prospective, HIPAA-compliant study. Subject willingness to participate in the study was determined by an e-mail. A single investigator conducted all interviews using a standard questionnaire. All subjects reviewed a video mockup demonstration of IRRR and three methods for viewing embedded images, as follows: (1) clickable hyperlinks to access a scrollable stack of images, (2) scrollable and enlargeable small-image thumbnails, and (3) scrollable but not enlargeable medium-sized images. Questionnaire responses, free comments, and general impressions were captured and analyzed. RESULTS: Seventy-two physicians (36 clinicians, 36 radiologists) were interviewed. Thirty-one clinicians (86%) expressed interest in using IRRR. Seventy-seven percent of subjects believed IRRR would improve communication. Ten clinicians (28%) preferred method 1, 18 (50%) preferred method 2, and 8 (22%) preferred method 3 for embedding images. Thirty clinicians (83%) stated that IRRR would improve efficiency. Twenty-two radiologists (61%) preferred selecting a tool button with a mouse and right-clicking images to embed them, 13 (36%) preferred pressing a function key, and 11 (31%) preferred dictating series and image numbers. The average time radiologists were willing to expend for embedding images was 66.7 seconds. CONCLUSIONS: Referring physicians and radiologist both believe IRRR would add value by improving communication with the potential to improve the workflow efficiency of referring physicians.


Assuntos
Atitude do Pessoal de Saúde , Diagnóstico por Imagem/estatística & dados numéricos , Documentação/estatística & dados numéricos , Melhoria de Qualidade/estatística & dados numéricos , Sistemas de Informação em Radiologia/estatística & dados numéricos , Fluxo de Trabalho , Inquéritos Epidemiológicos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA