Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Nat Commun ; 15(1): 4017, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740759

RESUMO

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Assuntos
Estimulação Encefálica Profunda , Tecnologia sem Fio , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Animais , Tecnologia sem Fio/instrumentação , Ratos , Eletrodos Implantados , Epilepsia/terapia , Masculino , Próteses e Implantes , Ratos Sprague-Dawley , Transdutores , Desenho de Equipamento , Ondas Ultrassônicas
2.
Sci Adv ; 10(12): eadk1278, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38507481

RESUMO

Studying placental functions is crucial for understanding pregnancy complications. However, imaging placenta is challenging due to its depth, volume, and motion distortions. In this study, we have developed an implantable placenta window in mice that enables high-resolution photoacoustic and fluorescence imaging of placental development throughout the pregnancy. The placenta window exhibits excellent transparency for light and sound. By combining the placenta window with ultrafast functional photoacoustic microscopy, we were able to investigate the placental development during the entire mouse pregnancy, providing unprecedented spatiotemporal details. Consequently, we examined the acute responses of the placenta to alcohol consumption and cardiac arrest, as well as chronic abnormalities in an inflammation model. We have also observed viral gene delivery at the single-cell level and chemical diffusion through the placenta by using fluorescence imaging. Our results demonstrate that intravital imaging through the placenta window can be a powerful tool for studying placenta functions and understanding the placental origins of adverse pregnancy outcomes.


Assuntos
Placenta , Placentação , Gravidez , Feminino , Camundongos , Animais , Placenta/diagnóstico por imagem , Microscopia/métodos , Imagem Óptica , Microscopia Intravital
3.
Nat Photonics ; 17(1): 89-95, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38149029

RESUMO

Optical-resolution photoacoustic microscopy (OR-PAM) can visualize wavelength-dependent optical absorption at the cellular level. However, OR-PAM suffers from a limited depth of field (DOF) due to the tight focus of the optical excitation beam, making it challenging to acquire high-resolution images of samples with uneven surfaces or high-quality volumetric images without z-scanning. To overcome this limitation, we propose needle-shaped beam photoacoustic microscopy (NB-PAM), which can extend the DOF to up to ~28-fold Rayleigh lengths via customized diffractive optical elements (DOEs). The DOE generate a needle beam with a well-maintained beam diameter, a uniform axial intensity distribution, and negligible sidelobes. The advantage of using NB-PAM is demonstrated by both histology-like imaging of fresh slide-free organs using a 266 nm laser and in vivo mouse brain vasculature imaging using a 532 nm laser. The approach provides new perspectives for slide-free intraoperative pathological imaging and in-vivo organ-level imaging.

4.
Nat Biomed Eng ; 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38036618

RESUMO

Techniques for imaging haemodynamics use ionizing radiation or contrast agents or are limited by imaging depth (within approximately 1 mm), complex and expensive data-acquisition systems, or low imaging speeds, system complexity or cost. Here we show that ultrafast volumetric photoacoustic imaging of haemodynamics in the human body at up to 1 kHz can be achieved using a single laser pulse and a single element functioning as 6,400 virtual detectors. The technique, which does not require recalibration for different objects or during long-term operation, enables the longitudinal volumetric imaging of haemodynamics in vasculature a few millimetres below the skin's surface. We demonstrate this technique in vessels in the feet of healthy human volunteers by capturing haemodynamic changes in response to vascular occlusion. Single-shot volumetric photoacoustic imaging using a single-element detector may facilitate the early detection and monitoring of peripheral vascular diseases and may be advantageous for use in biometrics and point-of-care testing.

5.
Nat Commun ; 14(1): 6477, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838708

RESUMO

Bionic multifunctional structural materials that are lightweight, strong, and perceptible have shown great promise in sports, medicine, and aerospace applications. However, smart monitoring devices with integrated mechanical protection and piezoelectric induction are limited. Herein, we report a strategy to grow the recyclable and healable piezoelectric Rochelle salt crystals in 3D-printed cuttlebone-inspired structures to form a new composite for reinforcement smart monitoring devices. In addition to its remarkable mechanical and piezoelectric performance, the growth mechanisms, the recyclability, the sensitivity, and repairability of the 3D-printed Rochelle salt cuttlebone composite were studied. Furthermore, the versatility of composite has been explored and applied as smart sensor armor for football players and fall alarm knee pads, focusing on incorporated mechanical reinforcement and electrical self-sensing capabilities with data collection of the magnitude and distribution of impact forces, which offers new ideas for the design of next-generation smart monitoring electronics in sports, military, aerospace, and biomedical engineering.


Assuntos
Esportes , Dispositivos Eletrônicos Vestíveis , Eletricidade , Impressão Tridimensional
6.
ACS Nano ; 17(16): 16008-16019, 2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37382226

RESUMO

Designing high-efficiency and low-cost catalysts with high current densities for the oxygen evolution reaction (OER) is critical for commercial seawater electrolysis. Here, we present a heterophase synthetic strategy for constructing an electrocatalyst with dense heterogeneous interfacial sites among crystalline Ni2P, Fe2P, CeO2, and amorphous NiFeCe oxides on nickel foam (NF). The synergistic effect of high-density crystalline and amorphous heterogeneous interfaces effectively promotes the redistribution of the charge density and optimizes the adsorbed oxygen intermediates, lowering the energy barrier and promoting the O2 desorption, thus enhancing the OER performance. The obtained NiFeO-CeO2/NF catalyst exhibited outstanding OER catalytic activity, with low overpotentials of 338 and 408 mV required to attain high current densities of 500 and 1000 mA cm-2, respectively, in alkaline natural seawater electrolytes. The solar-driven seawater electrolysis system presents a record-setting and stable solar-to-hydrogen conversion efficiency of 20.10%. This work provides directives for developing highly effective and stable catalysts for large-scale clean energy production.

7.
Anesthesiology ; 139(2): 173-185, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37079748

RESUMO

BACKGROUND: The administration of epinephrine after severe refractory hypotension, shock, or cardiac arrest restores systemic blood flow and major vessel perfusion but may worsen cerebral microvascular perfusion and oxygen delivery through vasoconstriction. The authors hypothesized that epinephrine induces significant microvascular constriction in the brain, with increased severity after repetitive dosing and in the aged brain, eventually leading to tissue hypoxia. METHODS: The authors investigated the effects of intravenous epinephrine administration in healthy young and aged C57Bl/6 mice on cerebral microvascular blood flow and oxygen delivery using multimodal in vivo imaging, including functional photoacoustic microscopy, brain tissue oxygen sensing, and follow-up histologic assessment. RESULTS: The authors report three main findings. First, after epinephrine administration, microvessels exhibited severe immediate vasoconstriction (57 ± 6% of baseline at 6 min, P < 0.0001, n = 6) that outlasted the concurrent increase in arterial blood pressure, while larger vessels demonstrated an initial increase in flow (108 ± 6% of baseline at 6 min, P = 0.02, n = 6). Second, oxyhemoglobin decreased significantly within cerebral vessels with a more pronounced effect in smaller vessels (microvessels to 69 ± 8% of baseline at 6 min, P < 0.0001, n = 6). Third, oxyhemoglobin desaturation did not indicate brain hypoxia; on the contrary, brain tissue oxygen increased after epinephrine application (from 31 ± 11 mmHg at baseline to 56 ± 12 mmHg, 80% increase, P = 0.01, n = 12). In the aged brains, microvascular constriction was less prominent yet slower to recover compared to young brains, but tissue oxygenation was increased, confirming relative hyperoxia. CONCLUSIONS: Intravenous application of epinephrine induced marked cerebral microvascular constriction, intravascular hemoglobin desaturation, and paradoxically, an increase in brain tissue oxygen levels, likely due to reduced transit time heterogeneity.


Assuntos
Microscopia , Oxiemoglobinas , Camundongos , Animais , Microcirculação , Oxiemoglobinas/farmacologia , Epinefrina/farmacologia , Oxigênio , Circulação Cerebrovascular
8.
Nat Commun ; 14(1): 2418, 2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37105973

RESUMO

The performance of ultrasonic transducers is largely determined by the piezoelectric properties and geometries of their active elements. Due to the brittle nature of piezoceramics, existing processing tools for piezoelectric elements only achieve simple geometries, including flat disks, cylinders, cubes and rings. While advances in additive manufacturing give rise to free-form fabrication of piezoceramics, the resultant transducers suffer from high porosity, weak piezoelectric responses, and limited geometrical flexibility. We introduce optimized piezoceramic printing and processing strategies to produce highly responsive piezoelectric microtransducers that operate at ultrasonic frequencies. The 3D printed dense piezoelectric elements achieve high piezoelectric coefficients and complex architectures. The resulting piezoelectric charge constant, d33, and coupling factor, kt, of the 3D printed piezoceramic reach 583 pC/N and 0.57, approaching the properties of pristine ceramics. The integrated printing of transducer packaging materials and 3D printed piezoceramics with microarchitectures create opportunities for miniaturized piezoelectric ultrasound transducers capable of acoustic focusing and localized cavitation within millimeter-sized channels, leading to miniaturized ultrasonic devices that enable a wide range of biomedical applications.

9.
bioRxiv ; 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36993341

RESUMO

Imaging hemodynamics is crucial for the diagnosis, treatment, and prevention of vascular diseases. However, current imaging techniques are limited due to the use of ionizing radiation or contrast agents, short penetration depth, or complex and expensive data acquisition systems. Photoacoustic tomography shows promise as a solution to these issues. However, existing photoacoustic tomography methods collect signals either sequentially or through numerous detector elements, leading to either low imaging speed or high system complexity and cost. To address these issues, here we introduce a method to capture a 3D photoacoustic image of vasculature using a single laser pulse and a single-element detector that functions as 6,400 virtual ones. Our method enables ultrafast volumetric imaging of hemodynamics in the human body at up to 1 kHz and requires only a single calibration for different objects and for long-term operations. We demonstrate 3D imaging of hemodynamics at depth in humans and small animals, capturing the variability in blood flow speeds. This concept can inspire other imaging technologies and find applications such as home-care monitoring, biometrics, point-of-care testing, and wearable monitoring.

10.
J Biomed Opt ; 28(8): 082804, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36817549

RESUMO

Significance: Based on acoustic detection of optical absorption, photoacoustic tomography (PAT) allows functional and molecular imaging beyond the optical diffusion limit with high spatial resolution. However, multispectral functional and molecular PAT is often limited by decreased spectroscopic accuracy and reduced detection sensitivity in deep tissues, mainly due to wavelength-dependent optical attenuation and inaccurate acoustic inversion. Aim: Previous work has demonstrated that reversible color-shifting can drastically improve the detection sensitivity of PAT by suppressing nonswitching background signals. We aim to develop a new color switching-based PAT method using reversibly switchable thermochromics (ReST). Approach: We developed a family of ReST with excellent water dispersion, biostability, and temperature-controlled color changes by surface modification of commercial thermochromic microcapsules with the hydrophilic polysaccharide alginate. Results: The optical absorbance of the ReST was switched on and off repeatedly by modulating the surrounding temperature, allowing differential photoacoustic detection that effectively suppressed the nonswitching background signal and substantially improved image contrast and detection sensitivity. We demonstrate reversible thermal-switching imaging of ReST in vitro and in vivo using three PAT modes at different length scales. Conclusions: ReST-enabled PAT is a promising technology for high-sensitivity deep tissue imaging of molecular activity in temperature-related biomedical applications, such as cancer thermotherapy.


Assuntos
Técnicas Fotoacústicas , Tomografia Computadorizada por Raios X , Técnicas Fotoacústicas/métodos , Acústica , Temperatura , Difusão , Tomografia/métodos
11.
Science ; 378(6626): 1315-1320, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36548427

RESUMO

Transparency in animals is a complex form of camouflage involving mechanisms that reduce light scattering and absorption throughout the organism. In vertebrates, attaining transparency is difficult because their circulatory system is full of red blood cells (RBCs) that strongly attenuate light. Here, we document how glassfrogs overcome this challenge by concealing these cells from view. Using photoacoustic imaging to track RBCs in vivo, we show that resting glassfrogs increase transparency two- to threefold by removing ~89% of their RBCs from circulation and packing them within their liver. Vertebrate transparency thus requires both see-through tissues and active mechanisms that "clear" respiratory pigments from these tissues. Furthermore, glassfrogs' ability to regulate the location, density, and packing of RBCs without clotting offers insight in metabolic, hemodynamic, and blood-clot research.


Assuntos
Anuros , Mimetismo Biológico , Coagulação Sanguínea , Eritrócitos , Fígado , Animais , Eritrócitos/citologia , Eritrócitos/fisiologia , Hemodinâmica , Fígado/fisiologia , Anuros/anatomia & histologia , Anuros/sangue , Anuros/fisiologia , Mimetismo Biológico/fisiologia , Fenômenos Ópticos , Contagem de Eritrócitos
12.
Photoacoustics ; 28: 100417, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36299642

RESUMO

Combining focused optical excitation and high-frequency ultrasound detection, optical-resolution photoacoustic microscopy (OR-PAM) can provide micrometer-level spatial resolution with millimeter-level penetration depth and has been employed in a variety of biomedical applications. However, it remains a challenge for OR-PAM to achieve a high imaging speed and a large field of view at the same time. In this work, we report a new approach to implement high-speed wide-field OR-PAM, using a cylindrically-focused transparent ultrasound transducer (CFT-UT). The CFT-UT is made of transparent lithium niobate coated with indium-tin-oxide as electrodes. A transparent cylindrical lens is attached to the transducer surface to provide an acoustic focal line with a length of 9 mm. The excitation light can pass directly through the CFT-UT from the above and thus enables a reflection imaging mode. High-speed imaging is achieved by fast optical scanning of the focused excitation light along the CFT-UT focal line. With the confocal alignment of the optical excitation and acoustic detection, a relatively high detection sensitivity is maintained over the entire scanning range. The CFT-UT-based OR-PAM system has achieved a cross-sectional frame rate of 500 Hz over the scanning range of 9 mm. We have characterized the system's performance on phantoms and demonstrated its application on small animal models in vivo. We expect the new CFT-UT-based OR-PAM will find matched biomedical applications that need high imaging speed over a large field of view.

13.
BME Front ; 20222022.
Artigo em Inglês | MEDLINE | ID: mdl-35928598

RESUMO

Large aperture ultrasonic arrays can be implemented by tiling together multiple pretested modules of high-density acoustic arrays with closely integrated multiplexing and buffering electronics to form a larger aperture with high yield. These modular arrays can be used to implement large 1.75D array apertures capable of focusing in elevation for uniform slice thickness along the axial direction which can improve image contrast. An important goal for large array tiling is obtaining high yield and sensitivity while reducing extraneous image artifacts. We have been developing tileable acoustic-electric modules for the implementation of large array apertures utilizing Application Specific Integrated Circuits (ASICs) implemented using 0.35 µ m high voltage (50 V) CMOS. Multiple generations of ASICs have been designed and tested. The ASICs were integrated with high-density transducer arrays for acoustic testing and imaging. The modules were further interfaced to a Verasonics Vantage imaging system and were used to image industry standard ultrasound phantoms. The first-generation modules comprise ASICs with both multiplexing and buffering electronics on-chip and have demonstrated a switching artifact which was visible in the images. A second-generation ASIC design incorporates low switching injection circuits which effectively mitigate the artifacts observed with the first-generation devices. Here, we present the architecture of the two ASIC designs and module types as well imaging results that demonstrate reduction in switching artifacts for the second-generation devices.

14.
Nat Commun ; 13(1): 3853, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35788594

RESUMO

Electronic visual prostheses, or biomimetic eyes, have shown the feasibility of restoring functional vision in the blind through electrical pulses to initiate neural responses artificially. However, existing visual prostheses predominantly use wired connections or electromagnetic waves for powering and data telemetry, which raises safety concerns or couples inefficiently to miniaturized implant units. Here, we present a flexible ultrasound-induced retinal stimulating piezo-array that can offer an alternative wireless artificial retinal prosthesis approach for evoking visual percepts in blind individuals. The device integrates a two-dimensional piezo-array with 32-pixel stimulating electrodes in a flexible printed circuit board. Each piezo-element can be ultrasonically and individually activated, thus, spatially reconfigurable electronic patterns can be dynamically applied via programmable ultrasound beamlines. As a proof of concept, we demonstrate the ultrasound-induced pattern reconstruction in ex vivo murine retinal tissue, showing the potential of this approach to restore functional, life-enhancing vision in people living with blindness.


Assuntos
Próteses Visuais , Animais , Biomimética , Cegueira/terapia , Humanos , Camundongos , Retina/diagnóstico por imagem , Retina/fisiologia , Retina/cirurgia , Visão Ocular
15.
Mater Horiz ; 9(8): 2180-2190, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35686946

RESUMO

Implantable medical electronics (IMEs) are now becoming increasingly prevalent for diagnostic and therapeutic purposes. Despite extensive efforts, a primary challenge for IMEs is reliable wireless power and communication to provide well-controlled, therapeutically relevant effects. Ultrasonic energy transfer and communication (UETC) employing traveling ultrasound waves to transmit energy has emerged as a promising wireless strategy for IMEs. Nevertheless, conventional UETC systems are rigid, bulky, and based on toxic lead-based piezoelectric materials, raising efficiency and safety concerns. Here, we present a novel transcutaneous UETC system based on a two-dimensional flexible lead-free piezoelectric array (f-LFPA) that hybridizes high-performance (piezoelectric coefficient d33 ≈ 503 pC N-1) (K,Na)NbO3-based eco-friendly piezo-units with soft structural components. The newly developed lead-free piezo-unit exhibits submicron ferroelectric domains and superior energy harvesting figures of merit (d33g33 ≈ 20 000 × 10-15 m2 N-1), resulting in the prepared f-LFPA demonstrating a high output voltage of 22.4 V, a power density of 0.145 W cm-2, and a signal-to-noise ratio of more than 30 dB within the FDA safety limits, while maintaining the flexibility for wide-angle receiving. Further ex vivo experiment demonstrates the adequate power supply capabilities of the f-LFPA and its possible application in future implantable eco-friendly bioelectronics for diagnostics, therapy, and real-time monitoring.


Assuntos
Fontes de Energia Elétrica , Ultrassom , Transferência de Energia , Próteses e Implantes
16.
ACS Appl Mater Interfaces ; 14(27): 30979-30990, 2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35767379

RESUMO

Ultrasonic transducers may need to operate in direct contact with the human body, especially with the skin or closer to blood vessels. Eco-friendly lead-free materials and devices are therefore being vigorously developed for biosafety considerations. This work presents high-performance potassium sodium niobate [(K,Na)NbO3, KNN]-based lead-free ceramics with composition-driven multiphase coexistence and their application on high-frequency ultrasonic transducers for multifunctional acoustic tweezers. A high piezoelectric constant d33 value of 332 pC/N, a good Curie temperature TC value of 348 °C, and improved in situ temperature stability were obtained in the piezoceramics via the construction multiple phases near room temperature and domain engineering. One to three piezocomposites were further fabricated based on the synthesized ceramics for higher electromechanical coupling properties. Lead-free high-frequency transducers as multifunctional acoustic tweezers for precise and selective manipulation of microparticles were designed and manufactured with a high center frequency of 23.4 MHz and a broad -6 dB bandwidth of 75.4%. Additionally, a stable transducer performance was obtained over a test temperature range of 23-60 °C, indicating good thermal stability in environments with fluctuating temperatures. Research on lead-free high-frequency transducers for ultrasound imaging and precise and selective manipulation of microparticles demonstrates their broad potential in fields such as medical therapy and diagnosis.

17.
Light Sci Appl ; 11(1): 138, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35577780

RESUMO

High-speed high-resolution imaging of the whole-brain hemodynamics is critically important to facilitating neurovascular research. High imaging speed and image quality are crucial to visualizing real-time hemodynamics in complex brain vascular networks, and tracking fast pathophysiological activities at the microvessel level, which will enable advances in current queries in neurovascular and brain metabolism research, including stroke, dementia, and acute brain injury. Further, real-time imaging of oxygen saturation of hemoglobin (sO2) can capture fast-paced oxygen delivery dynamics, which is needed to solve pertinent questions in these fields and beyond. Here, we present a novel ultrafast functional photoacoustic microscopy (UFF-PAM) to image the whole-brain hemodynamics and oxygenation. UFF-PAM takes advantage of several key engineering innovations, including stimulated Raman scattering (SRS) based dual-wavelength laser excitation, water-immersible 12-facet-polygon scanner, high-sensitivity ultrasound transducer, and deep-learning-based image upsampling. A volumetric imaging rate of 2 Hz has been achieved over a field of view (FOV) of 11 × 7.5 × 1.5 mm3 with a high spatial resolution of ~10 µm. Using the UFF-PAM system, we have demonstrated proof-of-concept studies on the mouse brains in response to systemic hypoxia, sodium nitroprusside, and stroke. We observed the mouse brain's fast morphological and functional changes over the entire cortex, including vasoconstriction, vasodilation, and deoxygenation. More interestingly, for the first time, with the whole-brain FOV and micro-vessel resolution, we captured the vasoconstriction and hypoxia simultaneously in the spreading depolarization (SD) wave. We expect the new imaging technology will provide a great potential for fundamental brain research under various pathological and physiological conditions.

18.
Artigo em Inglês | MEDLINE | ID: mdl-35468061

RESUMO

Ultrasound single-beam acoustic tweezer system has attracted increasing attention in the field of biomechanics. Cell biomechanics play a pivotal role in leukemia cell functions. To better understand and compare the cell mechanics of the leukemia cells, herein, we fabricated an acoustic tweezer system in-house connected with a 50-MHz high-frequency cylinder ultrasound transducer. Selected leukemia cells (Jurkat, K562, and MV-411 cells) were cultured, trapped, and manipulated by high-frequency ultrasound single beam, which was transmitted from the ultrasound transducer without contacting any cells. The relative deformability of each leukemia cell was measured, characterized, and compared, and the leukemia cell (Jurkat cell) gaining the highest deformability was highlighted. Our results demonstrate that the high-frequency ultrasound single beam can be utilized to manipulate and characterize leukemia cells, which can be applied to study potential mechanisms in the immune system and cell biomechanics in other cell types.


Assuntos
Acústica , Leucemia , Humanos , Leucemia/diagnóstico por imagem , Ultrassonografia/métodos
19.
Research (Wash D C) ; 2022: 9840574, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35169712

RESUMO

Flame-retardant and thermal management structures have attracted great attention due to the requirement of high-temperature exposure in industrial, aerospace, and thermal power fields, but the development of protective fire-retardant structures with complex shapes to fit arbitrary surfaces is still challenging. Herein, we reported a rotation-blade casting-assisted 3D printing process to fabricate nacre-inspired structures with exceptional mechanical and flame-retardant properties, and the related fundamental mechanisms are studied. 3-(Trimethoxysilyl)propyl methacrylate (TMSPMA) modified boron nitride nanoplatelets (BNs) were aligned by rotation-blade casting during the 3D printing process to build the "brick and mortar" architecture. The 3D printed structures are more lightweight, while having higher fracture toughness than the natural nacre, which is attributed to the crack deflection, aligned BN (a-BNs) bridging, and pull-outs reinforced structures by the covalent bonding between TMSPMA grafted a-BNs and polymer matrix. Thermal conductivity is enhanced by 25.5 times compared with pure polymer and 5.8 times of anisotropy due to the interconnection of a-BNs. 3D printed heat-exchange structures with vertically aligned BNs in complex shapes were demonstrated for efficient thermal control of high-power light-emitting diodes. 3D printed helmet and armor with a-BNs show exceptional mechanical and fire-retardant properties, demonstrating integrated mechanical and thermal protection.

20.
IEEE Trans Ultrason Ferroelectr Freq Control ; 69(11): 3095-3101, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35073262

RESUMO

Ultrasound medical imaging is an entrenched and powerful tool for medical diagnosis. Image quality in ultrasound is mainly dependent on performance of piezoelectric transducer elements, which is further related to the electromechanical performance of the constituent piezoelectric materials. With rising need for piezoelectric materials with better performance and low cost, a highly 〈001〉 textured piezo ceramic, Pb(Mg1/3Nb2/3)O3-Pb(Zr, Ti)O3, has been developed. Recently, textured ceramic materials can be produced at low cost and exhibit high piezoelectric strain constants and large electromechanical coupling coefficients. In this work, 15-MHz ultrasonic transducers with an effective aperture of 2.5 mm in diameter based on these highly 〈001〉 textured ceramics have been successfully fabricated. The fabricated transducers achieved a central frequency of 15 MHz, a fractional bandwidth of 67% (at -6 dB), a high effective electromechanical coupling coefficient [Formula: see text] of 0.55, and a low insertion loss (IL) of 21 dB. Ex vivo ultrasonic imaging of a porcine eyeball was used to assess the tomography quality of the transducer. The results show that utilized textured ceramic has a great potential in developing ultrasonic devices for biomedical imaging purposes.


Assuntos
Chumbo , Ultrassom , Suínos , Animais , Nióbio , Titânio , Desenho de Equipamento , Transdutores , Cerâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA