Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Med Phys ; 49(1): 110-119, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828073

RESUMO

Purpose: We have developed a bone-dedicated collimator with higher sensitivity but slightly degraded resolution on single-photon emission computed tomography (SPECT) for planar bone scintigraphy, compared with conventional low-energy high-resolution collimator. In this work, we investigated the feasibility of using the blind deconvolution algorithm to improve the resolution of planar images on bone scintigraphy. Materials and Methods: Monte Carlo simulation was performed with the NCAT phantom for modeling bone scintigraphy on the clinical dual-head SPECT scanner (Imagine NET 632, Beijing Novel Medical Equipment Ltd.) equipped with the bone-dedicated collimator. Maximum likelihood estimation method was used for the blind deconvolution algorithm. The initial estimation of point spread function (PSF) and iteration number for the method were determined by comparing the deblurred images obtained from different input parameters. We simulated different tumors in five different locations and with five different diameters to evaluate the robustness of the initial inputs. Furthermore, we performed chest phantom studies on the clinical SPECT scanner. The quantified increased contrast ratio (CR) between the tumor and the background was evaluated. Results: The 2 mm PSF kernel and 10 iterations provided a practical and robust deblurred image on our system. Those two inputs can generate robust deblurred images in terms of the tumor location and size with an average increased CR of 21.6%. The phantom studies also demonstrated the ability of blind deconvolution, using those two inputs, with increased CRs of 17%, 17%, 22%, 20%, and 13% for lesions with diameters of 1 cm, 2 cm, 3 cm, 4 cm, and 5 cm, respectively. Conclusions: It is feasible to use the blind deconvolution algorithm to deblur the planar images for SPECT bone scintigraphy. The appropriate values of the PSF kernel and the iteration number for the blind deconvolution can be determined using simulation studies.

2.
Med Phys ; 51(4): 2772-2787, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37921396

RESUMO

BACKGROUND: A compact PET/SPECT/CT system Inliview-3000B has been developed to provide multi-modality information on small animals for biomedical research. Its PET subsystem employed a dual-layer-offset detector design for depth-of-interaction capability and higher detection efficiency, but the irregular design caused some difficulties in calculating the normalization factors and the sensitivity map. Besides, the relatively larger (2 mm) crystal cross-section size also posed a challenge to high-resolution image reconstruction. PURPOSE: We present an efficient image reconstruction method to achieve high imaging performance for the PET subsystem of Inliview-3000B. METHODS: List mode reconstruction with efficient system modeling was used for the PET imaging. We adopt an on-the-fly multi-ray tracing method with random crystal sampling to model the solid angle, crystal penetration and object attenuation effect, and modify the system response model during each iteration to improve the reconstruction performance and computational efficiency. We estimate crystal efficiency with a novel iterative approach that combines measured cylinder phantom data with simulated line-of-response (LOR)-based factors for normalization correction before reconstruction. Since it is necessary to calculate normalization factors and the sensitivity map, we stack the two crystal layers together and extend the conventional data organization method here to index all useful LORs. Simulations and experiments were performed to demonstrate the feasibility and advantage of the proposed method. RESULTS: Simulation results showed that the iterative algorithm for crystal efficiency estimation could achieve good accuracy. NEMA image quality phantom studies have demonstrated the superiority of random sampling, which is able to achieve good imaging performance with much less computation than traditional uniform sampling. In the spatial resolution evaluation based on the mini-Derenzo phantom, 1.1 mm hot rods could be identified with the proposed reconstruction method. Reconstruction of double mice and a rat showed good spatial resolution and a high signal-to-noise ratio, and organs with higher uptake could be recognized well. CONCLUSION: The results validated the superiority of introducing randomness into reconstruction, and demonstrated its reliability for high-performance imaging. The Inliview-3000B PET subsystem with the proposed image reconstruction can provide rich and detailed information on small animals for preclinical research.


Assuntos
Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Ratos , Camundongos , Animais , Reprodutibilidade dos Testes , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Imagens de Fantasmas , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
3.
Appl Radiat Isot ; 186: 110256, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35533606

RESUMO

In single-photon emission computed tomography (SPECT), a micro-sized 99mTc source is routinely used for performance measurement, geometry calibration, and system matrix generation. Therefore, a micro-sized source is critical in nuclear instrument production and quality control. Standard methods can only produce a point source with a large size and low total activity, as they are limited by the concentration of the 99mTc solution. The absorption of 99mTc on ion exchange resins has been used; however, few studies have quantitatively evaluated the absorption process and optimized the source activity. This paper proposes a procedure for producing a micro-sized 99mTc resin source with a super-high concentration, as well as a method for the fast measurement of the point source time-activity curve (TAC). Experiments on two resin point sources with diameters of 0.681 mm and 0.326 mm were carried out. Two semi-empirical models, including the first kinetic model and the pseudo-second-order rate equation model, were used to fit TACs. The results show the first kinetic model fit better, which suggests an acquisition time of 2-4 h is needed for optimization. The verification experiment demonstrates a resin point source with a diameter of 0.35 mm and total activity of 10.6 mCi (i.e., 59.1 Ci/mL concentration) was produced.