Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Thyroid J ; 13(4)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38900599

RESUMO

Objective: Correct diagnosis and prognostic evaluation of medullary thyroid cancer (MTC) are crucial to treat patients. The purpose of this study was to evaluate the diagnostic and prognostic value of [18F]F-DOPA PET/CT in patients with MTC. Methods: We reviewed MTC patients who underwent [18F]F-DOPA PET/CT from June 2008 to November 2023. Clinical characteristics, follow-up data, and the following [18F]F-DOPA PET/CT parameters were recorded: maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), metabolic tumor volume (MTV), and SUVmean of multiple organs. The diagnostic value of PET/CT for the detection of tumor lesions was calculated. Serum basal calcitonin (bCt) and stimulated calcitonin (sCt) were determined. Receiver operating characteristics, Kaplan-Meier, and Cox regression analyses were performed. Results: In total, 109 patients (50 women, 59 men; average age, 55 ± 14 years) were included in the analysis. The patient-related sensitivity, specificity, and accuracy of [18F]F-DOPA PET/CT were 95%, 93%, and 94%, respectively. The lesion-related sensitivity, specificity, and accuracy were 65%, 99%, and 72%, respectively. The optimal cutoff values of bCt, sCt, and CEA to obtain positive [18F]F-DOPA PET/CT results were 64 pg/mL, 1808 pg/mL, and 4 µg/L, respectively. Patients with negative [18F]F-DOPA PET/CT had longer overall survival than patients with positive [18F]F-DOPA PET/CT results (P = 0.017). Significant positive correlations were found between bCt, sCt, and CEA with SUVmax, SUVmean, and MTV of [18F]F-DOPA PET/CT (P < 0.001). [18F]F-DOPA PET/CT results and MTV may be useful for the evaluation of the prognosis of patients with recurrent MTC, while age and MTV were independent prognostic factors in patients with primary MTC. For all patients, SUVmean of the left kidney, liver, aorta, and pancreas might be used to independently predict OS. Conclusion: [18F]F-DOPA PET/CT had great value for diagnosis and prognostic assessment in patients with MTC. The DOPA PET/CT parameter SUVmean and MTV showed significant association with OS.


Assuntos
Carcinoma Neuroendócrino , Di-Hidroxifenilalanina , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Glândula Tireoide , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Feminino , Masculino , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/mortalidade , Pessoa de Meia-Idade , Prognóstico , Adulto , Idoso , Carcinoma Neuroendócrino/diagnóstico por imagem , Carcinoma Neuroendócrino/mortalidade , Carcinoma Neuroendócrino/diagnóstico , Carcinoma Neuroendócrino/patologia , Di-Hidroxifenilalanina/análogos & derivados , Estudos Retrospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
2.
Eur J Nucl Med Mol Imaging ; 51(9): 2532-2546, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38696130

RESUMO

PURPOSE: To improve reproducibility and predictive performance of PET radiomic features in multicentric studies by cycle-consistent generative adversarial network (GAN) harmonization approaches. METHODS: GAN-harmonization was developed to harmonize whole-body PET scans to perform image style and texture translation between different centers and scanners. GAN-harmonization was evaluated by application to two retrospectively collected open datasets and different tasks. First, GAN-harmonization was performed on a dual-center lung cancer cohort (127 female, 138 male) where the reproducibility of radiomic features in healthy liver tissue was evaluated. Second, GAN-harmonization was applied to a head and neck cancer cohort (43 female, 154 male) acquired from three centers. Here, the clinical impact of GAN-harmonization was analyzed by predicting the development of distant metastases using a logistic regression model incorporating first-order statistics and texture features from baseline 18F-FDG PET before and after harmonization. RESULTS: Image quality remained high (structural similarity: left kidney ≥ 0.800, right kidney ≥ 0.806, liver ≥ 0.780, lung ≥ 0.838, spleen ≥ 0.793, whole-body ≥ 0.832) after image harmonization across all utilized datasets. Using GAN-harmonization, inter-site reproducibility of radiomic features in healthy liver tissue increased at least by ≥ 5 ± 14% (first-order), ≥ 16 ± 7% (GLCM), ≥ 19 ± 5% (GLRLM), ≥ 16 ± 8% (GLSZM), ≥ 17 ± 6% (GLDM), and ≥ 23 ± 14% (NGTDM). In the head and neck cancer cohort, the outcome prediction improved from AUC 0.68 (95% CI 0.66-0.71) to AUC 0.73 (0.71-0.75) by application of GAN-harmonization. CONCLUSIONS: GANs are capable of performing image harmonization and increase reproducibility and predictive performance of radiomic features derived from different centers and scanners.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Feminino , Masculino , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/normas , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Estudos Retrospectivos , Fluordesoxiglucose F18 , Idoso
3.
J Am Chem Soc ; 146(1): 1174-1184, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38153040

RESUMO

Controlling multimetallic ensembles at the atomic level is significantly challenging, particularly for high-entropy alloys with more than five elements. Herein, we report an innovative ultrasmall (∼2 nm) PtFeCoNiCuZn high-entropy intermetallic (PFCNCZ-HEI) with a well-ordered structure synthesized by using the space-confined strategy. By exploiting these combined metals, the PFCNCZ-HEI nanoparticles achieve an ultrahigh mass activity of 2.403 A mgPt-1 at 0.90 V vs reversible hydrogen electrode for the oxygen reduction reaction, which is up to 19-fold higher than that of state-of-the-art commercial Pt/C. A proton exchange membrane fuel cell assembled with PFCNCZ-HEI as the cathode (0.03 mgPt cm-2) exhibits a power density of 1.4 W cm-2 and a high mass-normalized rated power of 45 W mgPt-1. Furthermore, theoretical calculations reveal that the outer electrons of the non-noble-metal atoms on the surface of the PFCNCZ-HEI nanoparticle are modulated to show characteristics of multiple active centers. This work offers a promising catalyst design direction for developing highly ordered HEI nanoparticles for electrocatalysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA