Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Actas Dermosifiliogr (Engl Ed) ; 112(2): 134-141, 2021 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32910923

RESUMO

We present a series of general and specific recommendations based on pathophysiologic considerations for managing the most common adverse effects of apremilast that lead to treatment discontinuation: diarrhea, nausea, and headache. The recommendations are based on a review of the literature and the experience of a multidisciplinary team of 14 experts including dermatologists, rheumatologists, neurologists, gastroenterologists, pharmacists, and nurses. We propose a series of simple algorithms that include clinical actions and suggestions for pharmacologic treatment. The adverse effects of apremilast can be managed from a multidisciplinary approach. The purpose of optimizing management is to bring clinical benefits to patients.


Assuntos
Diarreia/induzido quimicamente , Cefaleia/induzido quimicamente , Náusea/induzido quimicamente , Inibidores da Fosfodiesterase 4/efeitos adversos , Talidomida/análogos & derivados , Terapia Combinada , Diarreia/dietoterapia , Diarreia/tratamento farmacológico , Diarreia/fisiopatologia , Gerenciamento Clínico , Cefaleia/tratamento farmacológico , Cefaleia/fisiopatologia , Cefaleia/prevenção & controle , Humanos , Náusea/dietoterapia , Náusea/tratamento farmacológico , Náusea/fisiopatologia , Equipe de Assistência ao Paciente , Inibidores da Fosfodiesterase 4/uso terapêutico , Guias de Prática Clínica como Assunto , Psoríase/tratamento farmacológico , Talidomida/efeitos adversos , Talidomida/uso terapêutico
2.
Colloids Surf B Biointerfaces ; 181: 973-980, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31382348

RESUMO

Sol-gel coatings are proposed as surface treatments for titanium-based materials to promote the osseointegration of prosthetic devices with the host. As precursors of sol-gel synthesis, two silanes were selected: 3-methacryloxypropyltrimethoxy silane and 2 tetramethyl orthosilane. Sol-gel synthesis was functionalized with the addition of two different organophosphorus compounds, namely, tris(trimethylsilyl) phosphite and tris(trimethylsilyl) phosphate. Depending on the organophosphorus compound, phosphorus was incorporated into the sol-gel network by different mechanisms: organophosphate was incorporated following a hydrolysis/polycondensation reaction with the precursors of synthesis (two organopolysiloxanes), whereas organophosphite was introduced into the network through transformation of trivalent phosphorus to pentavalent phosphorus following a Michaelis-Arbuzov reaction and subsequent reaction of hydrolysis/polycondensation. When compared to the control coating, which has good adhesion coating-substrate, only the addition of the organophosphite ensured good adhesion without altering synthesis. The resulting coating modified with organophosphite was subjected to cellular study and the concentration of this compound was varied to reach the highest enhancement of proliferation. It was demonstrated that by increasing the amount of organophosphite cell proliferation increased. Inspection of the surfaces of the coatings revealed that by increasing the quantity of organophosphite, adhesion to the substrate was compromised. Thus, an intermediate quantity of organophosphite was considered the most suitable for application on metallic prosthetic devices.


Assuntos
Compostos Organofosforados/química , Próteses e Implantes , Silanos/química , Géis/síntese química , Géis/química , Estrutura Molecular , Tamanho da Partícula , Silanos/síntese química , Propriedades de Superfície
3.
J Mech Behav Biomed Mater ; 91: 335-344, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30641479

RESUMO

The dry sliding wear behaviour of different Ti-Nb and Ti-Mo surfaces was investigated in order to evaluate the role of Nb and Mo ß-stabilizing elements in titanium wear resistance to consider them for biomedical applications. Dry sliding wear tests were performed under unlubricated conditions using a ball-on-plate tribometer (UMT) with reciprocating lineal movement of 1 Hz frequency at different loads (2 and 5 N) and against two counterface materials (alumina and stainless steel) to assess the effect of these parameters on wear. The results indicated an improvement in wear resistance for all the modified Ti surfaces. Metal-on-metal surfaces exhibited higher wear rate than ceramic-on-metal, and higher wear was observed for the more severe conditions. Wear rate values on modified surfaces were between 53% and 96% lower compared to pure Ti tested at 2 N, and up to 79% lower than Ti at 5 N. In both cases the highest wear reduction was observed for Ti-MoNH4Cl surface.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Mecânicos , Molibdênio/química , Nióbio/química , Titânio/química , Corrosão , Difusão , Fricção , Teste de Materiais , Aço Inoxidável/química , Propriedades de Superfície
4.
Farm Hosp ; 38(1): 44-9, 2014 Jan 01.
Artigo em Espanhol | MEDLINE | ID: mdl-24483859

RESUMO

PURPOSE: To compare the safety profile of telaprevir (TLV) and boceprevir (BOC) with each other and with those described in clinical trials (CT). MATERIAL AND METHODS: Retrospective multicenter observational study. Variables collected: age, sex, type of patient (naive, nonresponder or recurrent), fibroscan, Hb nadir, neutrophil and platelet count, presence of rash, anorectal discomfort, number of patients treated with erythropoiesis stimulating factors (EPO) and colony stimulating factors granulocyte (G-CSF). RESULTS: BOC vs CT: anemia (56.5% vs. 49%.), Thrombocytopenia (56.5% vs 32%, p = 0.023). neutropenia (17.4% vs. 29.5%). Use of EPO (13% vs 43%;. p = 0.008), pruritus (13% vs. 21.1%), rash (16.1% vs. 8.7%), anorectal discomfort (4.3% vs. 0%, p = 0.0001), dysgeusia (47.8% vs. 37%). TLV vs. CT: anemia (51.2% vs. 32%, p = 0.014), neutropenia (2.3 vs 3.6%), thrombocytopenia (41.9% vs. 27.4%, p = 0.05), pruritus (39.5% vs 47), rash (16.3% vs 55%, P <0.001), anorectal discomfort (39.5% vs 26%), dysgeusia (14% vs. 9.5%). BOC vs TLV: anemia (56.5% vs 51.2%), neutropenia (17.4% vs 2.3%), thrombocytopenia (56.5% vs 41.9%), rash (8.7% vs 16.3%), pruritus (39.5% vs 13%) and anorectal discomfort (4.3% vs 39.5%, P = 0.006), dysgeusia (14% vs 47.8%, P = 0.007), EPO (13% vs. 25.6%). GCSF was used for a patient treated with TLV. CONCLUSIONS: 1. BOC and TLV have shown a worse safety profile for anemia, thrombocytopenia and anorectal discomfort than those described in CT. 2. As in CT, anemia, neutropenia and thrombocytopenia were more common with BOC. Patients treated with TLV experienced more pruritus, rash and anorectal discomfort.


Assuntos
Antivirais/efeitos adversos , Oligopeptídeos/efeitos adversos , Prolina/análogos & derivados , Adulto , Idoso , Anemia/induzido quimicamente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prolina/efeitos adversos , Doenças Retais/induzido quimicamente , Estudos Retrospectivos , Trombocitopenia/induzido quimicamente
5.
J Mater Chem B ; 2(24): 3886-3896, 2014 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-32261735

RESUMO

Application of novel organic-inorganic hybrid sol-gel coatings containing dispersed hydroxyapatite (HAp) particles improves the biocompatibility, normal human osteoblast (NHOst) response in terms of osteoblast viability and adhesion of a Ti6Al4V alloy routinely used in medical implants. The incorporation of HAp particles additionally results in more effective barrier proprieties and improved corrosion protection of the Ti6Al4V alloy through higher degree of cross-linking in the organopolysiloxane matrix and enhanced film thickness.

6.
J Mater Chem B ; 2(45): 7955-7963, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-32262085

RESUMO

The biocompatibility and life of metallic implants can be enhanced through improving the biocompatibility and corrosion protection characteristics of the coatings used with these materials. In this study, triethylphosphite (TEP) was used to introduce phosphorus into organic-inorganic hybrid silica based sol-gel coatings prepared using γ-methacryloxypropyltrimethoxysilane and tetramethylorthosilicate. Addition of TEP dramatically increased the rate of intermolecular condensation and resulted in materials showing greater cross-linking. Protein (fibrinogen) uptake, osteoblast in vitro biocompatibility and corrosion resistance was enhanced in coatings containing TEP. Although higher concentrations of phosphorus supported the greatest improvement in biocompatibility, a compromise in the phosphorus concentration used would be required if corrosion resistance was most desirable parameter for optimisation. Films prepared by dip coating on Ti6Al4V alloys from these sols offer a promising alternative to wholly metallic prostheses.

7.
Farm Hosp ; 36(6): 525-30, 2012.
Artigo em Espanhol | MEDLINE | ID: mdl-23461446

RESUMO

OBJECTIVES: To discover the improvements in logistics, management and satisfaction of the patients after the implantation of a robot of dispensation (RAD) in the external consultations of Pharmacy. MATERIAL AND METHODS: Pre-post design: implantation of RAD. The study was conducted on a third level hospital. A new circuit of drugs was designed due to a change of location of the external consultations. Modifications on the pharmacy pro grams were implemented for the integration with RAD. The immobilized stock was measured, difference among the real-virtual existences for anti-retroviral drugs; measured as a per centage of the total and the index of rotation of the stock. Satisfaction surveys of 2007-2011 were compared after the realization of the different changes in the consultations. RESULTS: The circuit of drugs as well as the computer changes made were efficient for the maintenance of the stock of drugs. The immobilized stock decreased 2.209.935,77€ during the pe riod of the study. The index of rotation decreased from 1.87 to 0.79. The robot has reduced the waiting to less than 10 minutes in 90% with regard to the previous surveys. DISCUSSION: The incorporation of RAD in the consultations has meant improvements in the logistic, in the management and in.


Assuntos
Ambulatório Hospitalar/organização & administração , Serviço de Farmácia Hospitalar/organização & administração , Robótica , Equipamentos e Provisões , Humanos , Sistemas de Medicação no Hospital , Organização e Administração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA