Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiologia (Engl Ed) ; 65(3): 269-284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37268369

RESUMO

Magnetic resonance has become a first-line imaging modality in various clinical scenarios. The number of patients with different cardiovascular devices, including cardiac implantable electronic devices, has increased exponentially. Although there have been reports of risks associated with exposure to magnetic resonance in these patients, the clinical evidence now supports the safety of performing these studies under specific conditions and following recommendations to minimize possible risks. This document was written by the Working Group on Cardiac Magnetic Resonance Imaging and Cardiac Computed Tomography of the Spanish Society of Cardiology (SEC-GT CRMTC), the Heart Rhythm Association of the Spanish Society of Cardiology (SEC-Heart Rhythm Association), the Spanish Society of Medical Radiology (SERAM), and the Spanish Society of Cardiothoracic Imaging (SEICAT). The document reviews the clinical evidence available in this field and establishes a series of recommendations so that patients with cardiovascular devices can safely access this diagnostic tool.


Assuntos
Cardiologia , Cardiopatias , Humanos , Consenso , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
3.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28641952

RESUMO

OBJECTIVES: Accuracy on quantitative PET image analysis relies on the correct application of attenuation correction which is one of the major challenges for PET/MRI that remains to be solved. The purpose of this study is to evaluate the effect of MRI-based attenuation maps and the use of flexible coils on the quantitative accuracy of PET images with a special focus on large arteries. MATERIALS AND METHODS: PET/CT data from eight oncologic patients was used. PET data was reconstructed using attenuation maps with different level of detail emulating several approaches available on current PET/MRI scanners. PET images obtained with CT-based and MRI-based attenuation maps were compared to evaluate the quantitative biases obtained. The quantitative effect produced by flexible MRI receiver coils on the attenuation maps was also studied. RESULTS: The use of simpler attenuation maps produced increased biases between PET data reconstructed with CT-based and MRI-based attenuation maps for fat, non-fat soft-tissues and bone. Biases in lung were very high due to the large heterogeneity and inter-patient variability of the lung. The quantification on large arteries had small deviations except for the case when flexible coils were used. The TBR provided smaller biases in all cases as it cancelled out the similar deviations obtained for arteries and reference veins. CONCLUSIONS: Simplified attenuation maps used on PET/MRI significantly increase the quantitative variability of PET images especially on lungs and bones. The quantification of PET images acquired with PET/MRI scanners applied to studies of atherosclerosis has small deviations, especially when the TBR is considered.


Assuntos
Artérias/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Osso e Ossos/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Neoplasias/diagnóstico por imagem , Especificidade de Órgãos , Placa Aterosclerótica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Vísceras/diagnóstico por imagem , Imagem Corporal Total
6.
Nat Commun ; 6: 6473, 2015 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-25751743

RESUMO

Dilated cardiomyopathy (DCM) is the most frequent cause of heart failure and the leading indication for heart transplantation. Here we show that epigenetic regulator and central transcriptional instructor in adult stem cells, Bmi1, protects against DCM by repressing cardiac senescence. Cardiac-specific Bmi1 deletion induces the development of DCM, which progresses to lung congestion and heart failure. In contrast, Bmi1 overexpression in the heart protects from hypertrophic stimuli. Transcriptome analysis of mouse and human DCM samples indicates that p16(INK4a) derepression, accompanied by a senescence-associated secretory phenotype (SASP), is linked to severely impaired ventricular dimensions and contractility. Genetic reduction of p16(INK4a) levels reverses the pathology of Bmi1-deficient hearts. In parabiosis assays, the paracrine senescence response underlying the DCM phenotype does not transmit to healthy mice. As senescence is implicated in tissue repair and the loss of regenerative potential in aging tissues, these findings suggest a source for cardiac rejuvenation.


Assuntos
Envelhecimento/metabolismo , Cardiomiopatia Dilatada/metabolismo , Epigênese Genética , Insuficiência Cardíaca/metabolismo , Miocárdio/metabolismo , Complexo Repressor Polycomb 1/genética , Envelhecimento/patologia , Animais , Cardiomiopatia Dilatada/induzido quimicamente , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/patologia , Senescência Celular , Inibidor p16 de Quinase Dependente de Ciclina/genética , Inibidor p16 de Quinase Dependente de Ciclina/metabolismo , Embrião de Mamíferos , Feminino , Regulação da Expressão Gênica no Desenvolvimento , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/patologia , Ventrículos do Coração/metabolismo , Ventrículos do Coração/patologia , Humanos , Isoproterenol , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Contração Miocárdica/genética , Miocárdio/patologia , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Comunicação Parácrina , Complexo Repressor Polycomb 1/metabolismo , Transcriptoma
8.
Rev Esp Cardiol ; 53(4): 542-59, 2000 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-10758032

RESUMO

A wide perspective of the cardiac applications of magnetic resonance is presented in this report, including technical aspects of the practice, recommendations on the appropriate training of medical personnel for the practice of examination and also, an extensively commented review of the accepted clinical indications for the practice of a cardiac magnetic resonance imaging study at present.


Assuntos
Cardiopatias/patologia , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos
9.
J Magn Reson Imaging ; 7(5): 784-93, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9307902

RESUMO

The objective was to investigate how the blood flows in the thoracic aorta, with special emphasis on flow reversal and flow into the coronary arteries. Three-directional MR velocity mapping was used to map multidirectional flow velocities in the aorta in 14 normal subjects and 14 patients with coronary artery disease. Dynamic flow vector maps and through-plane velocity maps were used. The flow reversed in all subjects in the upper ascending aorta and usually also in the distal aortic arch. Retrograde flow became antegrade again at various levels in the ascending aorta and in the coronary sinuses. Seven flow characteristics were investigated that, lumped together, were significantly different (P = .0005) in normal subjects compared with patients and in normal subjects 70 years of age and older compared with those younger than 70 years of age.


Assuntos
Aorta Torácica/fisiopatologia , Doença das Coronárias/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Envelhecimento/fisiologia , Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo , Doença das Coronárias/diagnóstico , Feminino , Humanos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA