Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(5): 1135-1143, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38413344

RESUMO

OBJECTIVE: To demonstrate the value of a viscoelastic-based intraoperative transfusion algorithm to reduce non-RBC product administration in adult cardiac surgical patients. DESIGN: A prospective observational study. SETTING: At a quaternary academic teaching hospital. PARTICIPANTS: Cardiac surgical patients. INTERVENTIONS: Viscoelastic-based intraoperative transfusion algorithm. MEASUREMENTS AND MAIN RESULTS: The study authors compared intraoperative blood product transfusion rates in 184 cardiac surgical patients to 236 historic controls after implementing a viscoelastic-based algorithm. The authors found a non-significant reduction in transfusion of 23.8% for fresh frozen plasma (FFP) units (0.84 ± 1.4 v 0.64 ± 1.38; p = ns), 33.4% for platelet units (0.90 ± 1.39 v 0.60 ± 131; p = ns), and 15.8% for cryoprecipitate units (0.19 ± 0.54 v 0.16 ± 0.50; p = ns). They found a 43.9% reduction in red blood cell (RBC) units transfused (1.98 ± 2.24 v 0.55 ± 1.36; p = 0.008). There were no statistically significant differences in time to extubation (8.0 hours (4.0-21.0) v 8.0 (4.0-22.3), reoperation for bleeding (15 [12.3%] v 10 [10.6%]), intensive care unit length of stay (ICU LOS) (51.0 hours [28.0-100.5] v 53.5 [33.3-99.0]) or hospital LOS (9.0 days [6.0-15.0] v 10.0 [7.0-17.0]). Deviation from algorithm adherence was 32.7% (48/147). Packed RBC, FFP, platelets, cryoprecipitate, and cell saver were significantly reduced in the Algorithm Compliant Cohort compared with historic controls, whereas times to extubation, ICU LOS, and hospital LOS did not reach significance. CONCLUSIONS: After the implementation of a viscoelastic-based algorithm, patients received fewer packed RBC, FFP, platelets, cryoprecipitate, and cell saver. Algorithm-compliant patients received fewer transfusions; however, reductions in times to extubation, ICU LOS, and hospital LOS were not statistically significant compared with historic controls.


Assuntos
Transfusão de Sangue , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Ponte de Artéria Coronária , Hemorragia , Algoritmos , Estudos Retrospectivos
3.
Catheter Cardiovasc Interv ; 103(3): 472-481, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38197216

RESUMO

BACKGROUND: There is considerable debate about the hemodynamic effects of veno-arterial extracorporeal membrane oxygenation (VA-ECMO). AIMS: To evaluate the changes in left ventricular (LV) function, volumes, and work in patients treated with VA-ECMO using invasive LV catheterization and three-dimensional echocardiographic volumes. METHODS: Patients on VA-ECMO underwent invasive hemodynamic evaluation due to concerns regarding candidacy for decannulation. Hemodynamic parameters were reported as means±standard deviations or medians (interquartile ranges) after evaluating for normality. Paired comparisons were done to evaluate hemodynamics at the baseline (highest) and lowest tolerated levels of VA-ECMO support. RESULTS: Twenty patients aged 52.3 ± 15.8 years were included. All patients received VA-ECMO for refractory cardiogenic shock (5/20 SCAI stage D, 15/20 SCAI stage E). At 3.0 (2.0, 4.0) days after VA-ECMO cannulation, the baseline LV ejection fraction was 20% (15%, 27%). The baseline and lowest VA-ECMO flows were 4.0 ± 0.6 and 1.5 ± 0.6 L/min, respectively. Compared to the lowest flow, full VA-ECMO support reduced LV end-diastolic volume [109 ± 81 versus 134 ± 93 mL, p = 0.001], LV end-diastolic pressure (14 ± 9 vs. 19 ± 9 mmHg, p < 0.001), LV stroke work (1858 ± 1413 vs. 2550 ± 1486 mL*mmHg, p = 0.002), and LV pressure-volume area (PVA) (4507 ± 1910 vs. 5193 ± 2388, p = 0.03) respectively. Mean arterial pressure was stable at the highest and lowest flows (80 ± 16 vs. 75 ± 14, respectively; p = 0.08) but arterial elastance was higher at the highest VA-ECMO flow (4.9 ± 2.2 vs lowest flow 2.7 ± 1.6; p < 0.001). CONCLUSIONS: High flow VA-ECMO support significantly reduced LV end-diastolic pressure, end-diastolic volume, stroke work, and PVA compared to minimal support. The Ea was higher and MAP was stable or minimally elevated on high flow.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Resultado do Tratamento , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/terapia , Hemodinâmica , Ventrículos do Coração
4.
J Heart Lung Transplant ; 43(4): 539-546, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37956881

RESUMO

BACKGROUND: The Minnesota Pectoralis Risk Score (MPRS) utilizes computed tomography-quantified thoracic muscle and clinical variables to predict survival after left ventricular assist device (LVAD) implantation. The model has not been prospectively tested in HeartMate 3 recipients. METHODS: A single-center HeartMate 3 cohort from July 2016 to July 2021 (n = 108) was utilized for this analysis. Cohort subjects with complete covariates for MPRS calculation (pectoralis muscle measures, Black race, creatinine, total bilirubin, body mass index, bridge to transplant status, and presence/absence of contrast) implanted after MPRS development were included. MPRS were calculated on each subject. Receiver operating characteristic curves were generated to test model discrimination at 30-day, 90-day, and 1-year mortality post-LVAD. Next, the performance of the 1-year post-LVAD outcome was compared to the HeartMate 3 survival risk score (HM3RS). RESULTS: The mean age was 58 (15 years), 80% (86/108) were male, and 26% (28/108) were destination therapy. The area under the curve (AUC) for the MPRS model to predict post-LVAD mortality was 0.73 at 30 days, 0.78 at 90 days, and 0.81 at 1 year. The AUC for the HM3RS for the 1-year outcome was 0.693. Each 1-unit point of the MPRS was associated with a significant increase in the hazard rate of death after LVAD (hazard ratio 2.1, 95% confidence interval 1.5-3.0, p < 0.0001). CONCLUSIONS: The MPRS had high performance in this prospective validation, particularly with respect to 90-day and 1-year post-LVAD mortality. Such a tool can provide additional information regarding risk stratification to aid informed decision-making.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Insuficiência Cardíaca/cirurgia , Minnesota , Fatores de Risco , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Resultado do Tratamento
5.
J Heart Lung Transplant ; 43(3): 461-470, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37863451

RESUMO

BACKGROUND: Recently, several centers in the United States have begun performing donation after circulatory death (DCD) heart transplants (HTs) in adults. We sought to characterize the recent use of DCD HT, waitlist time, and outcomes compared to donation after brain death (DBD). METHODS: Using the United Network for Organ Sharing database, 10,402 adult (aged >18 years) HT recipients from January 2019 to June 2022 were identified: 425 (4%) were DCD and 9,977 (96%) were DBD recipients. Posttransplant outcomes in matched and unmatched cohorts and waitlist times were compared between groups. RESULTS: DCD and DBD recipients had similar age (57 years for both, p = 0.791). DCD recipients were more likely White (67% vs 60%, p = 0.002), on left ventricular assist device (LVAD; 40% vs 32%, p < 0.001), and listed as status 4 to 6 (60% vs 24%, p < 0.001); however, less likely to require inotropes (22% vs 40%, p < 0.001) and preoperative extracorporeal membrane oxygenation (0.9% vs 6%, p < 0.001). DCD donors were younger (29 vs 32 years, p < 0.001) and had less renal dysfunction (15% vs 39%, p < 0.001), diabetes (1.9% vs 3.8%, p = 0.050), or hypertension (9.9% vs 16%, p = 0.001). In matched and unmatched cohorts, early survival was similar (p = 0.22). Adjusted waitlist time was shorter in DCD group (21 vs 31 days, p < 0.001) compared to DBD cohort and 5-fold shorter (DCD: 22 days vs DBD: 115 days, p < 0.001) for candidates in status 4 to 6, which was 60% of DCD cohort. CONCLUSIONS: The community is using DCD mostly for those recipients who are expected to have extended waitlist times (e.g., durable LVADs, status >4). DCD recipients had similar posttransplant early survival and shorter adjusted waitlist time compared to DBD group. Given this early success, efforts should be made to expand the donor pool using DCD, especially for traditionally disadvantaged recipients on the waitlist.


Assuntos
Transplante de Coração , Obtenção de Tecidos e Órgãos , Adulto , Humanos , Doadores de Tecidos , Morte Encefálica , Fatores de Tempo , Sobrevivência de Enxerto , Estudos Retrospectivos , Morte
6.
Front Cardiovasc Med ; 10: 1271227, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37937291

RESUMO

Background: Pulmonary capillary wedge pressure (PCWP) is often used as a surrogate for left-ventricular end-diastolic pressure in patients (LVEDP) who are on veno-arterial extracorporeal membrane oxygenation (V-A ECMO) support for cardiogenic shock and cardiac arrest. However, the correlation between PCWP and LVEDP is not clear in the setting of V-A ECMO usage. We sought to evaluate this correlation in this case series. Methods: Patients were referred to our cardiac catheterization laboratory for invasive hemodynamic studies to assess their readiness for VA-ECMO decannulation. All patients underwent simultaneous left and right heart catheterization. Using standard techniques, we measured PCWP and LVEDP simultaneously. Continuous variables were reported as medians with interquartile ranges. The correlation between PCWP and LVEDP was evaluated using simple linear regression and reported as R2. Results: Four patients underwent invasive hemodynamic studies 4 (2.5, 7) days after VA-ECMO cannulation. All four patients had suffered in-hospital cardiac arrest and had been put on VA-ECMO. At the baseline level of VA-ECMO flow of 4.1 (3.8, 4.4) L/min, the median LVEDP and PCWP were 6 (4, 7.5) mmHg and 12 (6.5, 16) mmHg, respectively. At the lowest level of VA-ECMO flow of 1.9 (1.6, 2.0) L/min, the median LVEDP and PCWP was 13.5 (8.5, 16) mmHg and 15 (13, 18) mmHg, respectively. There was a poor correlation between the simultaneously measured PCWP and LVEDP (R2 = 0.03, p = 0.66). Conclusions: The PCWP may not correlate well with LVEDP in patients treated with VA-ECMO, particularly at high levels of VA-ECMO support.

7.
Indian J Thorac Cardiovasc Surg ; 39(Suppl 1): 161-169, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37525713

RESUMO

Left ventricular assist device (LVAD) is an option for bridge-to-transplant or destination therapy for patients with end-stage heart failure. Right heart failure (RHF) remains a complication after LVAD implantation that portends high morbidity and mortality, despite advances in LVAD technology. Definitions of RHF vary, but generally include the need for inotropic or pulmonary vasodilator support, or potential right ventricular (RV) mechanical circulatory support. This review covers the complex pathophysiology of RHF related to underlying myocardial dysfunction, interventricular dependence, and RV afterload, as well as treatment strategies to curtail this challenging problem.

8.
JACC Case Rep ; 15: 101861, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37283840

RESUMO

Obstruction of the inferior vena cava (IVC) following coronary artery bypass grafting (CABG) is a rare complication. We describe a case of IVC outflow obstruction secondary to inferior cavoatrial junction injury during CABG. The diagnostic and management approaches used to care for this patient are discussed. (Level of Difficulty: Intermediate.).

10.
J Surg Case Rep ; 2023(4): rjad186, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37082650

RESUMO

A 72-year-old patient presented with severe tricuspid regurgitation and patent foramen ovale (PFO) in the setting of severe mediastinal shifting after remote right pneumonectomy. Surgical approach was challenging given the significant herniation of the heart and left lung into the right hemithorax. This report describes tricuspid valve replacement with PFO closure via a right posterolateral thoracotomy and alternative cardiopulmonary bypass cannulation strategy.

13.
Eur Heart J Acute Cardiovasc Care ; 12(3): 175-183, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-36346080

RESUMO

AIMS: The long-term outcomes of patients treated with extracorporeal cardiopulmonary resuscitation (ECPR) for refractory ventricular tachycardia/ventricular fibrillation (VT/VF) out-of-hospital cardiac arrest (OHCA) remain poorly defined. The purpose of this study was to describe the hospital length of stay and long-term survival of patients who were successfully rescued with ECPR after refractory VT/VF OHCA. METHODS AND RESULTS: In this retrospective cohort study, the length of index admission and long-term survival of patients treated with ECPR after OHCA at a single centre were evaluated. In a sensitivity analysis, survival of patients managed with left ventricular assist device (LVAD) implantation or heart transplantation during the same period was also evaluated. Between 1 January 2016 and 12 January 2020, 193 patients were transferred for ECPR considerations and 160 underwent peripheral veno-arterial extracorporeal membrane oxygenation cannulation. Of these, 54 (33.7%) survived the index admission. These survivors required a median 16 days of intensive care and 24 days total hospital stay. The median follow-up time of the survivors was 1216 (683, 1461) days. Of all, 79.6 and 72.2% were alive at 1 and 4 years, respectively. Most deaths within the first year occurred among the patients requiring discharge to a long-term acute care facility. Overall survival rates at 4 years were similar in the ECPR and LVAD cohorts (P = 0.30) but were significantly higher for transplant recipients (P < 0.001). CONCLUSION: This data suggest that the lengthy index hospitalization required to manage OHCA patients with ECPR is rewarded by excellent long-term clinical outcomes in an expert ECPR programme.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Estudos Retrospectivos , Tempo de Internação , Reanimação Cardiopulmonar/métodos , Hospitais
14.
ASAIO J ; 69(3): 304-308, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35920751

RESUMO

A single-center continuous-flow left ventricular assist device (LVAD) cohort (n = 503) was reviewed for patients with information on cardiac rehabilitation (CR) participation (n = 273) over a 13-year period. The analysis was then limited LVAD recipients who fit into three main CR categories: those who graduated CR (n = 138), those who were able to but declined participation (n = 61), and those who were too sick to complete or start CR (n = 28). To assess the association between CR categories and mortality and hospitalizations on LVAD support, multivariate cox regression and negative binomial regression analyses were performed, respectively. Among those who started CR and had the opportunity to finish (enough follow-up time, insurance coverage), 79% graduated. Those who graduated CR had a 96% survival at 1 year (95% confidence interval [CI], 91-98). Compared with the graduated group, those in the too sick group had an increased hazards rate of mortality (hazard ratio, 2.85; 95% CI, 1.49-5.44; p < 0.01) and an increase in the incidence rate of hospitalizations (incidence rate ratio, 1.74; 95% CI, 1.14-2.66, p = 0.01). This study is the largest to date to report outcomes of LVAD recipients referred for CR. The lower readmission rates and high survival in the group that graduated CR provides further evidence for the safety of CR in LVAD recipients.


Assuntos
Reabilitação Cardíaca , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/epidemiologia , Estudos Retrospectivos , Modelos de Riscos Proporcionais , Resultado do Tratamento
15.
J Thorac Cardiovasc Surg ; 166(6): 1684-1694.e18, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35643769

RESUMO

BACKGROUND: Correction of valvular disease is often undertaken during left ventricular assist device (LVAD) implantation with uncertain benefit. We analyzed clinical outcomes with HeartMate 3 (HM3; Abbott) LVAD implantation in those with various concurrent valve procedures (HM3+VP) with those with an isolated LVAD implant (HM3 alone). METHODS: The study included 2200 patients with HM3 implanted within the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) trial portfolio who underwent 820 concurrent procedures among which 466 (21.8%) were HM3+VP. VPs included 101 aortic, 61 mitral, 163 tricuspid; 85 patients had multiple VPs. Perioperative complications, major adverse events, and survival were analyzed. RESULTS: Patients who underwent HM3+VP had higher-acuity Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles (1-2: 41% vs 31%) compared with no VPs (P < .05). The cardiopulmonary bypass time (124 vs 76 minutes; P < .0001) and hospital length of stay (20 vs 18 days; P < .0001) were longer in HM3+VP. A higher incidence of stroke (4.9% vs 2.4%), bleeding (33.9% vs 23.8%), and right heart failure (41.5% vs 29.6%) was noted in HM3+VP at 0 to 30 days (P < .01), with no difference in 30-day mortality (3.9% vs 3.3%) or 2-year survival (81.7% vs 80.8%). Analysis of individual VP showed no differences in survival compared to HM3 alone. No differences were noted among patients with either significant mitral (moderate or worse) or tricuspid (moderate or worse) regurgitation with or without corrective surgery. CONCLUSIONS: Concurrent VPs, commonly performed during LVAD implantation, are associated with increased morbidity during the index hospitalization, with no effect on short- and long-term survival. There is sufficient equipoise to consider a randomized trial on the benefit of commonly performed VPs (such as mitral or tricuspid regurgitation correction), during LVAD implantation.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Procedimentos Cirúrgicos Torácicos , Humanos , Catéteres , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Estudos Multicêntricos como Assunto
16.
J Thorac Cardiovasc Surg ; 165(5): 1860, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36049966
17.
JTCVS Open ; 16: 305-320, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204696

RESUMO

Objective: Mitral valve surgery (MVS) carries substantial risk of postoperative atrial fibrillation (PAF). Identifying patients who benefit from prophylactic left atrial appendage amputation (LAAA) or maze is ill-defined. To guide such interventions, we determined preoperative predictors of PAF and investigated 3-year survival of patients with PAF. Methods: We performed a retrospective analysis of patients undergoing isolated MVS (N = 670) between 2011 and 2021. Patients with preoperative atrial fibrillation, LAAA or pulmonary vein isolation were excluded. Patient characteristics were compared between those without PAF and those who developed transient or prolonged PAF. Predictors of any PAF and prolonged PAF were identified using multivariable regression analysis. Results: In total, 504 patients without preoperative atrial fibrillation underwent isolated MVS. Of them, 303 patients (60.2%) developed PAF; 138 (27.3%) developed transient and 165 (32.7%) developed prolonged (beyond 30 days) PAF. Patients with PAF were older (65.7 vs 54.3 years, P < .001), with larger left atria (4.8 vs 4.3 cm, P < .001), greater prevalence of hypertension (60% vs 47.8%, P < .05), and were New York Heart Association class III/IV (36% vs 8.5%, P < .001). Independent predictors of PAF included left atria volume index (odds ratio [OR], 1.02; P < .003), older age (OR, 1.04; P < .001), heart failure (OR, 6.73; P < .001), and sternotomy (OR, 2.19; P < .002). Age, heart failure, and sternotomy were independent predictors of prolonged PAF. Patients with PAF had greater mortality at 3 years compared with those without PAF (5.3% vs 0.5%, P < .005). On multivariable analysis, PAF was associated with increased mortality (hazard ratio, 7.81; P < .046). Conclusions: PAF is common after MVS and associated with late mortality. Older age, advanced heart failure, and sternotomy are associated with prolonged PAF. These factors may identify patients who would benefit from prophylactic LAAA or ablation during MVS.

18.
J Card Surg ; 37(11): 3912-3915, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36116047

RESUMO

Pump thrombosis (PT) is a rare and infrequent complication of HeartMate III left ventricular assist device (LVAD). While there are reports of PT in the postoperative period, to our knowledge, there have been no prior reports on PT in the intraoperative period. Here we present a case of a 24-year-old female who required HeartMate III LVAD implantation for progressive heart failure and the intraoperative period was complicated with PT. Managing PT in the intraoperative period is challenging and time-sensitive because of its rare occurrence and paucity of recommendations in diagnosing the PT.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Adulto , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Trombose/etiologia , Adulto Jovem
19.
ESC Heart Fail ; 9(5): 3496-3504, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35883259

RESUMO

AIMS: Cardiopulmonary stress test (CPX) is routinely performed when evaluating patient candidacy for left ventricular assist device (LVAD) implantation. The predictive value of hypotensive systolic blood pressure (SBP) response during CPX on clinical outcomes is unknown. This study aims to determine the effect of hypotensive SBP response during to clinical outcomes among patients who underwent LVAD implantation. METHODS AND RESULTS: This was a retrospective single center study enrolling consecutive patients implanted with a continuous flow LVAD between 2011 and 2022. Hypotensive SBP response was defined as peak exercise SBP below the resting value. Multivariable Cox-regression analysis was performed to evaluate the relationship between hypotensive SBP response and all-cause mortality within 30 and 90 days of LVAD implantation. A subgroup analysis was performed for patients implanted with a HeartMate III (HM III) device. Four hundred thirty-two patients underwent LVAD implantation during the pre-defined period and 156 with INTERMACS profiles 3-6 met our inclusion criteria. The median age was 63 years (IQR 54-69), and 52% had ischaemic cardiomyopathy. Hypotensive SBP response was present in 35% of patients and was associated with increased 90 day all-cause mortality (unadjusted HR 9.16, 95% CI 1.98-42; P = 0.0046). Hazard ratio remained significant after adjusting for age, INTERMACS profile, serum creatinine, and total bilirubin. Findings were similar in the HM III subgroup. CONCLUSIONS: Hypotensive SBP response on pre-LVAD CPX is associated with increased perioperative and 90 day mortality after LVAD implantation. Additional studies are needed to determine the mechanism of increased mortality observed.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Hipotensão , Humanos , Pessoa de Meia-Idade , Teste de Esforço , Estudos Retrospectivos , Coração Auxiliar/efeitos adversos , Hipotensão/complicações
20.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3038-3046, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35545456

RESUMO

OBJECTIVES: Does point-of-care viscoelastic testing in patients undergoing left ventricular assist device implantation or orthotopic heart transplantation reduce non-red blood cell transfusion or improve postoperative outcomes? DESIGN: A retrospective observational study. SETTING: At a single-center tertiary university hospital. PARTICIPANTS: Patients undergoing left ventricular assist device placement or heart transplantation INTERVENTIONS: The authors implemented a TEG-based transfusion algorithm to reduce non-red cell transfusion rates compared with historical controls. MEASUREMENTS AND MAIN RESULTS: From May 15, 2019, through March 20, 2020, 68 patients underwent left ventricular assist device placement or heart transplantation. Algorithm adherence was 49.2%. After adjusting for relevant variables, platelet (odds ratio [OR] 0.58 [0.39-0.84]; p = 0.004) and cryoprecipitate (OR 0.37 [0.19-0.72]; p = 0.004) transfusion rates and time to extubation (OR -14.1 [-25.8 to -2.3]; p = 0.020) were significantly reduced compared with historical controls. After adjusting for relevant clinical variables, there was a statistically significant reduction in plasma (median [interquartile range] 0.16 [0.07-0.36], p < 0.001), platelets (0.06 [0.02-0.21], p < 0.001), and cryoprecipitate (0.06 [0.01-0.47], p = 0.007) transfusion rates and time to extubation (-16.95 [-27.20 to -6.71], p = 0.002) compared with historical controls. CONCLUSIONS: The authors report a statistically significant reduction in transfusion of platelets and cryoprecipitate and time to extubation after adjusting for relevant clinical variables compared with historical controls and a significant reduction in the transfusion of plasma, platelets, and cryoprecipitate and time to extubation in those patients for whom the transfusion algorithm was followed. Their results suggest the importance of implementing transfusion algorithms for patients undergoing heart transplantation and left ventricular assist device placement and of accounting for adherence.


Assuntos
Transplante de Coração , Coração Auxiliar , Algoritmos , Transfusão de Sangue , Humanos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA