Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 28(17): 24708-24720, 2020 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-32907005

RESUMO

Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10-12/τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

2.
Opt Lett ; 44(7): 1841-1843, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30933161

RESUMO

Soliton microcombs offer the prospect of advanced optical metrology and timing systems in compact form factors. In these applications, the pumping of microcombs directly from a semiconductor laser without amplification or triggering components is desirable to reduce system power and to simplify system design. At the same time, low-repetition-rate microcombs are required in many comb applications as an interface to detectors and electronics, but their increased mode volume makes them challenging to pump at low power. Here 10 GHz repetition rate soliton microcombs are directly pumped by low-power (<20 mW) diode lasers. High-Q silica microresonators are used for this low-power operation and are packaged into fiber-connectorized modules that feature temperature control for improved long-term frequency stability.

3.
Opt Express ; 24(14): 15403-16, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-27410816

RESUMO

We have developed a four-channel optically pumped atomic magnetometer for magnetoencephalography (MEG) that incorporates a passive diffractive optical element (DOE). The DOE allows us to achieve a long, 18-mm gradiometer baseline in a compact footprint on the head. Using gradiometry, the sensitivities of the channels are < 5 fT/Hz1/2, and the 3-dB bandwidths are approximately 90 Hz, which are both sufficient to perform MEG. Additionally, the channels are highly uniform, which offers the possibility of employing standard MEG post-processing techniques. This module will serve as a building block of an array for magnetic source localization.


Assuntos
Encéfalo/diagnóstico por imagem , Magnetoencefalografia/instrumentação , Dispositivos Ópticos , Magnetismo
4.
Phys Med Biol ; 58(17): 6065-77, 2013 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-23939051

RESUMO

The authors have detected magnetic fields from the human brain with two independent, simultaneously operating rubidium spin-exchange-relaxation-free magnetometers. Evoked responses from auditory stimulation were recorded from multiple subjects with two multi-channel magnetometers located on opposite sides of the head. Signal processing techniques enabled by multi-channel measurements were used to improve signal quality. This is the first demonstration of multi-sensor atomic magnetometer magnetoencephalography and provides a framework for developing a non-cryogenic, whole-head magnetoencephalography array for source localization.


Assuntos
Magnetoencefalografia/instrumentação , Desenho de Equipamento , Potenciais Evocados Auditivos , Humanos
5.
J Magn Magn Mater ; 324(17): 2613-2619, 2012 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-22773885

RESUMO

Magnetic relaxometry methods have been shown to be very sensitive in detecting cancer cells and other targeted diseases. Superconducting Quantum Interference Device (SQUID) sensors are one of the primary sensor systems used in this methodology because of their high sensitivity with demonstrated capabilities of detecting fewer than 100,000 magnetically-labeled cancer cells. The emerging technology of atomic magnetometers (AM) represents a new detection method for magnetic relaxometry with high sensitivity and without the requirement for cryogens. We report here on a study of magnetic relaxometry using both AM and SQUID sensors to detect cancer cells that are coated with superparamagnetic nanoparticles through antibody targeting. The AM studies conform closely to SQUID sensor results in the measurement of the magnetic decay characteristics following a magnetization pulse. The AM and SQUID sensor data are well described theoretically for superparamagnetic particles bound to cells and the results can be used to determine the number of cells in a cell culture or tumor. The observed fields and magnetic moments of cancer cells are linear with the number of cells over a very large range. The AM sensor demonstrates very high sensitivity for detecting magnetically labeled cells does not require cryogenic cooling and is relatively inexpensive.

6.
Psychiatry Res ; 200(2-3): 754-60, 2012 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-22521895

RESUMO

There is much debate on the diagnostic classification of Myalgic Encephalomyelitis (ME), Chronic Fatigue Syndrome (CFS) and chronic fatigue (CF). Post-exertional malaise (PEM) is stressed as a key feature. This study examines whether CF and CFS, with and without PEM, are distinct diagnostic categories. Fukuda's criteria were used to diagnose 144 patients with chronic fatigue and identify patients with CFS and CF, i.e. those not fulfilling the Fukuda's criteria. PEM was rated by means of a scale with defined scale steps between 0 and 6. CFS patients were divided into those with PEM lasting more than 24h (labeled: ME) and without PEM (labeled: CFS). The 12-item Fibromyalgia and Chronic Fatigue Syndrome (FF) Rating Scale was used to measure severity of illness. Plasma interleukin-1 (IL-1), tumor necrosis factor (TNF)α, and lysozyme, and serum neopterin were employed as external validating criteria. Using fatigue, a subjective feeling of infection and PEM we found that ME, CFS, and CF were distinct categories. Patients with ME had significantly higher scores on concentration difficulties and a subjective experience of infection, and higher levels of IL-1, TNFα, and neopterin than patients with CFS. These biomarkers were significantly higher in ME and CFS than in CF patients. PEM loaded highly on the first two factors subtracted from the data set, i.e. "malaise-sickness" and "malaise-hyperalgesia". Fukuda's criteria are adequate to make a distinction between ME/CFS and CF, but ME/CFS patients should be subdivided into ME (with PEM) and CFS (without PEM).


Assuntos
Síndrome de Fadiga Crônica/diagnóstico , Fadiga/diagnóstico , Adulto , Biomarcadores/sangue , Diagnóstico Diferencial , Fadiga/sangue , Síndrome de Fadiga Crônica/sangue , Feminino , Humanos , Inflamação/sangue , Interleucina-1/sangue , Masculino , Pessoa de Meia-Idade , Neopterina/sangue , Índice de Gravidade de Doença , Fator de Necrose Tumoral alfa/sangue
7.
Phys Rev Lett ; 101(10): 103002, 2008 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-18851213

RESUMO

We have trapped large numbers of copper (Cu) and silver (Ag) atoms using buffer-gas cooling. Up to 3 x 10{12} Cu atoms and 4 x 10{13} Ag atoms are trapped. Lifetimes are as long as 5 s, limited by collisions with the buffer gas. Ratios of elastic to inelastic collision rates with He are >or=10{6}, suggesting Cu and Ag are favorable for use in ultracold applications. The temperature dependence of the Ag-3He collision rate varies as T;{5.8+/-0.4}. We find that this temperature dependence is inconsistent with the behavior predicted for relaxation arising from the spin-rotation interaction, and conclude that the Ag-3He system displays anomalous collisional behavior in the multiple-partial wave regime. Gold (Au) was ablated into 3He buffer gas, however, atomic Au lifetimes were observed to be too short to permit trapping.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA