Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Lab Anal ; 26(4): 227-31, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22811353

RESUMO

Herbal supplements hawthorn and ashwagandha (Indian ginseng) are indicated for cardiac illnesses and may be taken by patients receiving digoxin therapy. Because both hawthorn and ashwagandha are known to interfere with serum digoxin measurements using certain digoxin immunoassays, we investigated potential interference of these two herbal supplements with the new homogenous sequential chemiluminescent assay for digoxin based on the luminescent oxygen channeling technology (LOCI digoxin) for application on the Dimension and Vista platform. When aliquots of a drug-free serum pool were supplemented with various amounts of hawthorn (three different commercial preparations) or ashwagandha (two different commercial preparations) and apparent digoxin values were measured using LOCI digoxin assay on Dimension Vista 1500 analyzer we observed none-detected values except when aliquots were supplemented with very high amounts of the herbal extracts. When aliquots of a serum digoxin pool (prepared by pooling specimens from patients receiving digoxin) where further supplemented with various amounts of these supplements and digoxin concentrations were remeasured, statistically significant falsely higher digoxin values were observed only in specimens containing very high amounts of these supplements. Such interference may not be clinically significant. We conclude that new LOCI digoxin assay is virtually free from interferences of herbal supplements, hawthorn, and ashwagandha.


Assuntos
Crataegus/química , Digoxina/sangue , Imunoensaio/métodos , Extratos Vegetais/química , Withania/química , Digoxina/química , Interações Medicamentosas , Humanos
2.
J Clin Lab Anal ; 26(3): 143-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22628228

RESUMO

Spironolactone, a potassium-sparing diuretic metabolized to canrenone is often used with digoxin to treat various conditions including congestive heart failure. Potassium canrenoate is a similar drug, which is also metabolized to canrenone. Due to reported both positive and negative interference of spironolactone, potassium canrenoate, and their common metabolite canrenone with digoxin immunoassays, we investigated potential interference of these compounds with the new homogenous sequential chemiluminescent assay for digoxin based on the luminescent oxygen channeling technology (LOCI digoxin) for application on the Dimension and Vista platform. When aliquots of a drug-free serum pool were supplemented with various amounts of spironolactone, potassium canrenoate, or canrenone and apparent digoxin values were measured using Dimension Vista LOCI digoxin assay, we observed no detected value except when aliquots were supplemented with very high amounts of potassium canrenoate or canrenone. However, we observed that apparent digoxin concentrations were very low. When aliquots of a serum digoxin pool (prepared by pooling specimens from patients receiving digoxin), were further supplemented with various amounts of spironolactone, potassium canrenoate, or canrenone and serum digoxin concentrations were remeasured using the LOCIdigoxin assay, only statistically significant falsely lower digoxin values (negative interference) were observed in specimens containing very high amounts of canrenone or potassium canrenoate. However, such small bias may not have any clinical significance. We conclude that new Dimension Vista LOCI digoxin assay is virtually free from interferences of spironolactone, potassium canrenoate, and their common metabolite canrenone.


Assuntos
Ácido Canrenoico/química , Canrenona/química , Digoxina/sangue , Imunoensaio/métodos , Espironolactona/química , Ácido Canrenoico/sangue , Canrenona/sangue , Digoxina/química , Humanos , Imunoensaio/normas , Medições Luminescentes/métodos , Medições Luminescentes/normas , Modelos Moleculares , Espironolactona/sangue
3.
J Clin Lab Anal ; 25(3): 212-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21567471

RESUMO

Discordant carbamazepine values as determined by two different immunoassays may be due to different cross-reactivities with the active metabolite carbamazepine 10, 11-epoxide and may cause confusion in interpreting carbamazepine serum levels. In this study, we compared carbamazepine values in samples containing carbamazepine and the epoxide metabolite, as determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) and by two commercial carbamazepine immunoassays: the PETINIA and the ADVIA Centaur carbamazepine. Clinical specimens were used for the comparative studies wherein we determined carbamazepine concentrations using the PETINIA, ADVIA Centaur, and LC-MS/MS assays. We observed an excellent correlation between carbamazepine concentrations determined by the ADVIA Centaur and LC-MS/MS methods while carbamazepine values were overestimated using the PETINIA assay. When aliquots of drug-free serum were supplemented with clinically relevant concentrations of the carbamazepine epoxide metabolite, we observed negligible cross-reactivity of epoxide with the ADVIA Centaur assay but over 90% cross-reactivity with the PETINIA assay. We conclude that the ADVIA centaur assay accurately measures carbamazepine concentrations in plasma or serum and that the PETINIA assay significantly overestimates true carbamazepine concentration. Such discordance may cause confusion in interpreting serum carbamazepine levels.


Assuntos
Carbamazepina/sangue , Imunoensaio/métodos , Espectrometria de Massas/métodos , Kit de Reagentes para Diagnóstico , Carbamazepina/análogos & derivados , Cromatografia Líquida , Humanos
4.
J Clin Lab Anal ; 24(6): 413-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21089173

RESUMO

Spironolactone, a potassium sparing diuretic metabolized to canrenone, is often used with digoxin to treat various conditions including congestive heart failure. Potassium canrenoate is a similar drug that is also metabolized to canrenone. Due to reported interference of spironolactone, potassium canrenoate, and their common metabolite canrenone with digoxin immunoassays, we investigated potential interference of these compounds with Dimension Vista Digoxin immunoassay using Flex reagent cartridge. Aliquots of a drug-free serum pool were supplemented with various amounts of spironolactone, potassium canrenoate, or canrenone and apparent digoxin values were measured using Dimension Vista digoxin assay, we observed none-detected value except when aliquots were supplemented with higher amounts of spironolactone or canrenone. Similarly, when aliquots of a serum digoxin pool (prepared by pooling specimens from patients receiving digoxin) where further supplemented with various amounts of spironolactone, potassium canrenoate, or canrenone, we observed moderately falsely elevated digoxin values only in specimens containing higher amounts of spironolactone or canrenone. We conclude that spironolactone and canrenone but not potassium canrenoate may cause modest interference with Dimension Vista digoxin assay but such interferences may not be clinically significant except with very high amounts of canrenone.


Assuntos
Ácido Canrenoico/química , Ácido Canrenoico/farmacologia , Canrenona/sangue , Canrenona/química , Cardiotônicos/farmacologia , Digoxina/sangue , Digoxina/química , Imunoensaio , Antagonistas de Receptores de Mineralocorticoides/sangue , Antagonistas de Receptores de Mineralocorticoides/química , Espironolactona/sangue , Espironolactona/química , Bioensaio , Ácido Canrenoico/sangue , Ácido Canrenoico/imunologia , Canrenona/imunologia , Cardiotônicos/sangue , Química Clínica/métodos , Reações Cruzadas , Digoxina/imunologia , Interações Medicamentosas , Monitoramento de Medicamentos , Humanos , Imunoensaio/métodos , Antagonistas de Receptores de Mineralocorticoides/imunologia , Antagonistas de Receptores de Mineralocorticoides/metabolismo , Concentração Osmolar , Kit de Reagentes para Diagnóstico , Espironolactona/imunologia , Espironolactona/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA