Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(4): 043903, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489933

RESUMO

Positron annihilation spectroscopy provides a sensitive means of non-destructive characterization of materials, capable of probing single atom vacancies in solids with 10-7 sensitivity. We detail here the development of a magnetically guided, variable energy, pulsed positron beam designed to conduct depth-dependent defect studies in metals, semiconductors, and dielectrics, which will be the first of its kind in the United States. The design of the target stage provides capabilities for measurements during in situ annealing up to 800 °C and incorporates a new approach to minimize the background due to energetic backscattered positrons. The developed beam at Bowling Green State University provides a powerful tool for characterization of thin films, devices, and ion irradiated materials.

2.
Rev Sci Instrum ; 93(1): 013305, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35104976

RESUMO

We describe here the development and characterization of a position-sensitive detector for Rydberg atom experiments. The detector builds on an earlier design that field-ionized incident Rydberg positronium (Ps) atoms and then electrostatically focused the freed positrons onto a micro-channel plate (MCP) detector without the use of a position sensitive anode. In this design, pulses from the MCP are deposited onto a resistive anode, providing a means of measuring the incident particles' x, y positions. The first detector constructed utilized a pair of MCPs in a chevron configuration and was used to observe the focusing of Rydberg Ps atoms from an electrostatic mirror. A second detector, developed for use in a measurement of the 1S-2S interval of Ps, incorporates three MCPs in a Z-stack configuration to produce larger pulses. Using a UV-induced signal, we have characterized the performance of the assembled detectors, finding a spatial resolution of ∼1.4 mm for the largest induced pulses and for pulse widths of ∼7-10 ns FWHM; pulse times can be resolved to better than 1 ns. The Ps induced signal is anticipated to yield pulses ∼5 times larger, which are expected to achieve a spatial resolution of <1 mm. Appropriate lenses could make possible applications involving either imaging a large area or magnifying a small area of the incident Ps spatial distribution.

3.
Sci Adv ; 6(31): eaba8437, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32832684

RESUMO

The nondestructive investigation of single vacancies and vacancy clusters in ion-irradiated samples requires a depth-resolved probe with atomic sensitivity to defects. The recent development of short-pulsed positron beams provides such a probe. Here, we combine depth-resolved Doppler broadening and positron annihilation lifetime spectroscopies to identify vacancy clusters in ion-irradiated Fe and measure their density as a function of depth. Despite large concentrations of dislocations and voids in the pristine samples, positron annihilation measurements uncovered the structure of vacancy clusters and the change in their size and density with irradiation dose. When combined with transmission electron microscopy measurements, the study demonstrates an association between the increase in the density of small vacancy clusters with irradiation and a remarkable reduction in the size of large voids. This, previously unknown, mechanism for the interaction of cascade damage with voids in ion-irradiated materials is a consequence of the high porosity of the initial microstructure.

4.
Rev Sci Instrum ; 89(5): 053106, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29864868

RESUMO

We report on the design and characterization of a modular γ-ray detector assembly developed for accurate and efficient detection of coincident 511 keV back-to-back γ-rays following electron-positron annihilation. Each modular detector consists of 16 narrow lutetium yttrium oxyorthosilicate scintillators coupled to a multi-anode Hamamatsu H12700B photomultiplier tube. We discuss the operation and optimization of 511 keV γ-ray detection resulting from testing various scintillators and detector arrangements concluding with an estimate of the coincident 511 keV detection efficiency for the intended experiment and a preliminary test representing one-quarter of the completed array.

5.
Phys Rev Lett ; 119(5): 053201, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28949762

RESUMO

Slow atoms in Rydberg states can exhibit specular reflection from a cylindrical surface upon which an azimuthally periodic potential is imposed. We have constructed a concave mirror of this type, in the shape of a truncated oblate ellipsoid of revolution, which has a focal length of (1.50±0.01) m measured optically. When placed near the center of a long vacuum pipe, this structure brings a beam of n=32 positronium (Ps) atoms to a focus on a position sensitive detector at a distance of (6.03±0.03) m from the Ps source. The intensity at the focus implies an overall reflection efficiency of ∼30%. The focal spot diameter (32±1) mm full width at half maximum is independent of the atoms' flight times from 20 to 60 µs, thus indicating that the mirror is achromatic to a good approximation. Mirrors based on this principle would be of use in a variety of experiments, allowing for improved collection efficiency and tailored transport or imaging of beams of slow Rydberg atoms and molecules.

6.
Rev Sci Instrum ; 87(11): 113307, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910370

RESUMO

We describe here the development and characterization of a micro-channel plate (MCP) based detector designed for the efficient collection and detection of Rydberg positronium (Ps) atoms for use in a time-of-flight apparatus. The designed detector collects Rydberg atoms over a large area (∼4 times greater than the active area of the MCP), ionizing incident atoms and then collecting and focusing the freed positrons onto the MCP. Here we discuss the function, design, and optimization of the device. The detector has an efficiency for Rydberg Ps that is two times larger than that of the γ-ray scintillation detector based scheme it has been designed to replace, with half the background signal. In principle, detectors of the type described here could be readily employed for the detection of any Rydberg atom species, provided a sufficient field can be applied to achieve an ionization rate of ≥108/s. In such cases, the best time resolution would be achieved by collecting ionized electrons rather than the positive ions.

7.
Phys Rev Lett ; 117(21): 216402, 2016 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-27911545

RESUMO

The affinity A_{Ps} of positronium (Ps) atoms for a metal is the negative of the maximum kinetic energy with which Ps is emitted into vacuum when thermalized positrons in a metal encounter the surface. When this quantity is measured by ground state Ps time of flight (TOF), the precision is severely limited by the short triplet state lifetime of 142 ns. By quickly converting the emitted Ps atoms into long-lived Rydberg states, we are able to dramatically increase the TOF to allow precision measurements of A_{Ps}. From our measurements made on a Cu(110) sample at T=128 K, we find A_{Ps}(128 K)=(-2.476±0.010_{stat}±0.013_{syst}) eV, compared with the result A_{Ps}(128 K)=(-2.545±0.010_{num}±0.010_{syst}) eV found using highly accurate generalized gradient approximations for both electrons and positrons within density functional theory. Such precision opens up opportunities in the quest for an improved density functional.

8.
Phys Rev Lett ; 114(15): 153201, 2015 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-25933312

RESUMO

Recently it has been discovered that positronium (Ps), after forming in metal-organic framework (MOF) crystals, is emitted into vacuum with a high efficiency and low energy that can only be explained by its propagating as delocalized Bloch states. We show that the Ps atoms are emitted from MOFs in a series of narrow energy peaks consistent with Ps at Bloch-state energy minima being emitted adiabatically into the vacuum. This implies that the Ps emission energy spectra can be directly compared with calculations to obtain detailed information about the Ps band structure in the MOF crystal. The narrow energy width of the lowest energy Ps peak from one MOF sample (2-Methylimidazole zinc salt ZIF-8) suggests it originates from a polaronic Ps surface state. Other peaks can be assigned to Ps with an effective mass of about twice that of bare Ps. Given the immense catalog of available MOF crystals, it should be possible to tune the Ps properties to make vastly improved sources with high production efficiency and a narrow energy spread, for use in fundamental physics experiments.

9.
Phys Rev Lett ; 110(22): 223201, 2013 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-23767720

RESUMO

Vibrational Feshbach resonances are dominant features of positron annihilation for incident positron energies in the range of the molecular vibrations. Studies in relatively small molecules are described that elucidate the role of intramolecular vibrational energy redistribution into near-resonant multimode states, and the subsequent coupling of these modes to the positron continuum, in suppressing or enhancing these resonances. The implications for annihilation in other molecular species, and the necessary ingredients of a more complete theory of resonant positron annihilation, are discussed.

10.
Phys Rev Lett ; 109(11): 113201, 2012 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-23005624

RESUMO

Positron binding to molecules is compared to the analogous electron-molecule bound states. For both, the bound lepton density is diffuse and remains outside the valence shell. Positron binding energies are found to be one to two orders of magnitude larger than those of the negative ions due to two effects: the orientation of the molecular dipole moment allows the positron to approach it more closely and, for positrons, lepton correlations (e.g., via dipole polarizability) contribute more strongly.

11.
Phys Rev Lett ; 108(9): 093201, 2012 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-22463631

RESUMO

Positron annihilation on many molecules occurs via positron capture into vibrational Feshbach resonances, with annihilation rates often further enhanced by energy transfer to vibrational excitations weakly coupled to the positron continuum. Data presented here uncover another scenario in which the positron couples directly to a quasicontinuum of multimode vibrational states. A model that assumes excitation and escape from a statistically complete ensemble of multimode vibrations is presented that reproduces key features of the data.

12.
Phys Rev Lett ; 105(7): 073201, 2010 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-20868040

RESUMO

Channel coupling is a phenomenon that has been investigated for many scattering processes, and is responsible for the formation of cusps or steps in the cross sections for open scattering channels at, or near, the onset of a new scattering channel. It has long been speculated that the opening of the positronium formation channel may lead to the formation of such cusp features in the elastic positron scattering cross section. In this work, elastic scattering of positrons has been measured in the region of the positronium formation threshold for the noble gases He-Xe. Cusplike behavior is observed and, while the features which are observed appear broad, they represent a magnitude of between 4 and 15% of the total elastic cross section. No evidence is found of any other features in this region, at least within the uncertainty of the present data, discounting the possibility of scattering resonances.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA