1.
Int J Hyg Environ Health ; 234: 113713, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33621861

RESUMO

We developed an inductively coupled plasma mass spectrometry (ICP-MS) method using Universal Cell Technology (UCT) with a PerkinElmer NexION ICP-MS, to measure arsenic (As), chromium (Cr), and nickel (Ni) in human urine samples. The advancements of the UCT allowed us to expand the calibration range to make the method applicable for both low concentrations of biomonitoring applications and high concentrations that may be observed from acute exposures and emergency response. Our method analyzes As and Ni in kinetic energy discrimination (KED) mode with helium (He) gas, and Cr in dynamic reaction cell (DRC) mode with ammonia (NH3) gas. The combination of these elements is challenging because a carbon source, ethanol (EtOH), is required for normalization of As ionization in urine samples, which creates a spectral overlap (40Ar12C+) on 52Cr. This method additionally improved lab efficiency by combining elements from two of our previously published methods(Jarrett et al., 2007; Quarles et al., 2014) allowing us to measure Cr and Ni concentrations in urine samples collected as part of the National Health and Nutrition Examination Survey (NHANES) beginning with the 2017-2018 survey cycle. We present our rigorous validation of the method selectivity and accuracy using National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM), precision using in-house prepared quality control materials, and a discussion of the use of a modified UCT, a BioUCell, to address an ion transmission phenomenon we observed on the NexION 300 platform when using higher elemental concentrations and high cell gas pressures. The rugged method detection limits, calculated from measurements in more than 60 runs, for As, Cr, and Ni are 0.23 µg L-1, 0.19 µg L-1, and 0.31 µg L-1, respectively.


Assuntos
Arsênio , Monitoramento Biológico , Cromo , Humanos , Níquel , Inquéritos Nutricionais , Tecnologia
2.
Clin Chim Acta ; 485: 1-6, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29894782

RESUMO

BACKGROUND: Comprehensive information on the effect of time and temperature storage on the measurement of elements in human, whole blood (WB) by inductively coupled plasma-dynamic reaction cell-mass spectrometry (ICP-DRC-MS) is lacking, particularly for Mn and Se. METHODS: Human WB was spiked at 3 concentration levels, dispensed, and then stored at 5 different temperatures: -70 °C, -20 °C, 4 °C, 23 °C, and 37 °C. At 3 and 5 weeks, and at 2, 4, 6, 8, 10, 12, 36 months, samples were analyzed for Pb, Cd, Mn, Se and total Hg, using ICP-DRC-MS. We used a multiple linear regression model including time and temperature as covariates to fit the data with the measurement value as the outcome. We used an equivalence test using ratios to determine if results from the test storage conditions, warmer temperature and longer time, were comparable to the reference storage condition of 3 weeks storage time at -70 °C. RESULTS: Model estimates for all elements in human WB samples stored in polypropylene cryovials at -70 °C were equivalent to estimates from samples stored at 37 °C for up to 2 months, 23 °C up to 10 months, and -20 °C and 4 °C for up to 36 months. Model estimates for samples stored for 3 weeks at -70 °C were equivalent to estimates from samples stored for 2 months at -20 °C, 4 °C, 23 °C and 37 °C; 10 months at -20 °C, 4 °C, and 23 °C; and 36 months at -20 °C and 4 °C. This equivalence was true for all elements and pools except for the low concentration blood pool for Cd. CONCLUSIONS: Storage temperatures of -20 °C and 4 °C are equivalent to -70 °C for stability of Cd, Mn, Pb, Se, and Hg in human whole blood for at least 36 months when blood is stored in sealed polypropylene vials. Increasing the sample storage temperature from -70 °C to -20 °C or 4 °C can lead to large energy savings. The best analytical results are obtained when storage time at higher temperature conditions (e.g. 23 °C and 37 °C) is minimized because recovery of Se and Hg is reduced. Blood samples stored in polypropylene cryovials also lose volume over time and develop clots at higher temperature conditions (e.g., 23 °C and 37 °C), making them unacceptable for elemental testing after 10 months and 2 months, respectively.


Assuntos
Cádmio/sangue , Chumbo/sangue , Magnésio/sangue , Mercúrio/sangue , Selênio/sangue , Temperatura , Humanos , Espectrometria de Massas , Fatores de Tempo
3.
Talanta ; 162: 114-122, 2017 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-27837806

RESUMO

We improved our inductively coupled plasma mass spectrometry (ICP-MS) whole blood method [1] for determination of lead (Pb), cadmium (Cd), and mercury (Hg) by including manganese (Mn) and selenium (Se), and expanding the calibration range of all analytes. The method is validated on a PerkinElmer (PE) ELAN® DRC II ICP-MS (ICP-DRC-MS) and uses the Dynamic Reaction Cell (DRC) technology to attenuate interfering background ion signals via ion-molecule reactions. Methane gas (CH4) eliminates background signal from 40Ar2+ to permit determination of 80Se+, and oxygen gas (O2) eliminates several polyatomic interferences (e.g. 40Ar15N+, 54Fe1H+) on 55Mn+. Hg sensitivity in DRC mode is a factor of two higher than vented mode when measured under the same DRC conditions as Mn due to collisional focusing of the ion beam. To compensate for the expanded method's longer analysis time (due to DRC mode pause delays), we implemented an SC4-FAST autosampler (ESI Scientific, Omaha, NE), which vacuum loads the sample onto a loop, to keep the sample-to-sample measurement time to less than 5min, allowing for preparation and analysis of 60 samples in an 8-h work shift. The longer analysis time also resulted in faster breakdown of the hydrocarbon oil in the interface roughing pump. The replacement of the standard roughing pump with a pump using a fluorinated lubricant, Fomblin®, extended the time between pump maintenance. We optimized the diluent and rinse solution components to reduce carryover from high concentration samples and prevent the formation of precipitates. We performed a robust calculation to determine the following limits of detection (LOD) in whole blood: 0.07µgdL-1 for Pb, 0.10µgL-1 for Cd, 0.28µgL-1 for Hg, 0.99µgL-1 for Mn, and 24.5µgL-1 for Se.


Assuntos
Exposição Dietética/análise , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Espectrometria de Massas/métodos , Oligoelementos/sangue , Cádmio/sangue , Calibragem , Monitoramento Ambiental/instrumentação , Humanos , Chumbo/sangue , Manganês/sangue , Mercúrio/sangue , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Selênio/sangue , Oligoelementos/normas
4.
J Anal At Spectrom ; 2014(2): 297-303, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26229219

RESUMO

Biomonitoring and emergency response measurements are an important aspect of the Division of Laboratory Sciences of the National Center for Environmental Health, Centers for Disease Control and Prevention (CDC). The continuing advancement in instrumentation allows for enhancements to existing analytical methods. Prior to this work, chromium and nickel were analyzed on a sector field inductively coupled plasma-mass spectrometer (SF-ICP-MS). This type of instrumentation provides the necessary sensitivity, selectivity, accuracy, and precision but due to the higher complexity of instrumentation and operation, it is not preferred for routine high throughput biomonitoring needs. Instead a quadrupole based method has been developed on a PerkinElmer NexION™ 300D ICP-MS. The instrument is operated using 6.0 mL min-1 helium as the collision cell gas and in kinetic energy discrimination mode, interferences are successfully removed for the analysis of 52Cr (40Ar12C and 35Cl16O1H) and 60Ni (44Ca16O). The limits of detection are 0.162 µg L-1 Cr and 0.248 µg L-1 Ni. Method accuracy using NIST SRM 2668 level 1 (1.08 µg L-1 Cr and 2.31µg L-1 Ni) and level 2 (27.7 µg L-1 Cr and 115 µg L-1 Ni) was within the 95% confidence intervals reported in the NIST certificate. Among-run precision is less than 10% RSDs (N = 20) for in house quality control and NIST SRM urine samples. While the limits of detection (LOD) for the new quadrupole ICP-UCT-MS with KED method are similar to the SF-ICP-MS method, better measurement precision is observed for the quadrupole method. The new method presented provides fast, accurate, and more precise results on a less complex and more robust ICP-MS platform.

5.
J Anal At Spectrom ; 27(11): 1975-1982, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26290619

RESUMO

Biomonitoring for manganese (Mn) exposure is important due to its potential to cause adverse health effects. In this study, we investigate how different sample preparation methods (simple dilution, digestion, volumetric, gravimetric), calibration protocols (aqueous, blood-based, standard additions), and instrumental techniques affect Mn method bias and analytical imprecision. The techniques used included graphite furnace atomic absorption spectrometry (GFAAS), dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS), and sector field (SF-) ICP-MS. We analyzed NIST SRM 1643e Trace Elements in Water and SRM 1598a Inorganic Constituents in Animal Serum (both certified for Mn), and SRM 955c Toxic Metals in Caprine Blood - Level 1 (not certified for Mn). Various matrix effects in ICP-MS produced inaccurate results for SRM 1643e and discrepant results for SRM 955c. In the absence of a certified value for Mn in SRM 955c, we assigned a "consensus" value by combining data from the New York State Department of Health (NYS), the Centers for Disease Control and Prevention (CDC) and the Centre de toxicologie du Québec (CTQ). With this interlaboratory approach, we established an "all-lab" consensus value of 16.3 ± 0.8 µg L-1 based on data from DRC-ICP-MS with simple dilution sample preparation and blood-based calibration. We also assigned an "all-method" consensus value of 16.3 ± 0.9 µg L-1 based on GFAAS and SF-ICP-MS data from the NYS lab and the DRC-ICP-MS all-lab consensus value. Although the expanded uncertainty (U) calculated for the consensus values may not fully account for all sources of uncertainty, it does show the relative variation that might be expected from one study to the next for the determination of Mn in blood.