Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Br J Surg ; 111(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39213397

RESUMO

BACKGROUND: Several ablation confirmation software methods for minimum ablative margin assessment have recently been developed to improve local outcomes for patients undergoing thermal ablation of colorectal liver metastases. Previous assessments were limited to single institutions mostly at the place of development. The aim of this study was to validate the previously identified 5 mm minimum ablative margin (A0) using autosegmentation and biomechanical deformable image registration in a multi-institutional setting. METHODS: This was a multicentre, retrospective study including patients with colorectal liver metastases undergoing CT- or ultrasound-guided microwave or radiofrequency ablation during 2009-2022, reporting 3-year local disease progression (residual unablated tumour or local tumour progression) rates by minimum ablative margin across all institutions and identifying an intraprocedural contrast-enhanced CT-based minimum ablative margin associated with a 3-year local disease progression rate of less than 1%. RESULTS: A total of 400 ablated colorectal liver metastases (median diameter of 1.5 cm) in 243 patients (145 men; median age of 62 [interquartile range 54-70] years) were evaluated, with a median follow-up of 26 (interquartile range 17-40) months. A total of 119 (48.9%) patients with 186 (46.5%) colorectal liver metastases were from international institutions B, C, and D that were not involved in the software development. Three-year local disease progression rates for 0 mm, >0 and <5 mm, and 5 mm or larger minimum ablative margins were 79%, 15%, and 0% respectively for institution A (where the software was developed) and 34%, 19%, and 2% respectively for institutions B, C, and D combined. Local disease progression risk decreased to less than 1% with an intraprocedurally confirmed minimum ablative margin greater than 4.6 mm. CONCLUSION: A minimum ablative margin of 5 mm or larger demonstrates optimal local oncological outcomes. It is proposed that an intraprocedural minimum ablative margin of 5 mm or larger, confirmed using biomechanical deformable image registration, serves as the A0 for colorectal liver metastasis thermal ablation.


Assuntos
Inteligência Artificial , Neoplasias Colorretais , Neoplasias Hepáticas , Margens de Excisão , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Progressão da Doença , Ablação por Radiofrequência/métodos
2.
Eur Radiol ; 34(9): 5541-5550, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38334762

RESUMO

PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Margens de Excisão , Idoso , Resultado do Tratamento , Adulto
3.
Cardiovasc Intervent Radiol ; 46(12): 1748-1754, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37563313

RESUMO

PURPOSE: This study aims to evaluate the technical efficacy and local tumor progression-free survival (LTPFS) of a standardized workflow for thermal ablation of colorectal liver metastases (CRLM) consisting of CT during hepatic arteriography (CTHA)-based imaging analysis, stereotactic thermal ablation, and computer-based software assessment of ablation margins. MATERIALS AND METHODS: This investigator initiated, single-center, single-arm prospective trial will enroll up to 50 patients (≤ 5 CRLM, Measuring ≤ 5 cm). Procedures will be performed in an angio-CT suite under general anesthesia. The primary objective is to estimate LTPFS with a follow-up of up to 2 years and secondary objectives are analysis of the impact of minimal ablative margins on LTPFS, adverse events, contrast media utilization and radiation exposure, overall oncological outcomes, and anesthesia/procedural time. Adverse events (AE) will be recorded by CTCAE (Common Toxicity Criteria for Adverse Events), and Bayesian optimal phase-2 design will be applied for major intraprocedural AE stop boundaries. The institutional CRLM ablation registry will be used as benchmark for comparative analysis with the historical cohort. DISCUSSION: The STEREOLAB trial will introduce a high-precision and standardized thermal ablation workflow for CRLM consisting of CT during hepatic arteriography imaging, stereotactic guidance, and ablation confirmation. Trial Registration ClinicalTrials.gov identifier: (NCT05361551).


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Angiografia , Teorema de Bayes , Ablação por Cateter/métodos , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos Retrospectivos , Software , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
4.
Radiology ; 307(2): e221373, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36719291

RESUMO

Background Confirming ablation completeness with sufficient ablative margin is critical for local tumor control following colorectal liver metastasis (CLM) ablation. An image-based confirmation method considering patient- and ablation-related biomechanical deformation is an unmet need. Purpose To evaluate a biomechanical deformable image registration (DIR) method for three-dimensional (3D) minimal ablative margin (MAM) quantification and the association with local disease progression following CT-guided CLM ablation. Materials and Methods This single-institution retrospective study included patients with CLM treated with CT-guided microwave or radiofrequency ablation from October 2015 to March 2020. A biomechanical DIR method with AI-based autosegmentation of liver, tumors, and ablation zones on CT images was applied for MAM quantification retrospectively. The per-tumor incidence of local disease progression was defined as residual tumor or local tumor progression. Factors associated with local disease progression were evaluated using the multivariable Fine-Gray subdistribution hazard model. Local disease progression sites were spatially localized with the tissue at risk for tumor progression (<5 mm) using a 3D ray-tracing method. Results Overall, 213 ablated CLMs (mean diameter, 1.4 cm) in 124 consecutive patients (mean age, 57 years ± 12 [SD]; 69 women) were evaluated, with a median follow-up interval of 25.8 months. In ablated CLMs, an MAM of 0 mm was depicted in 14.6% (31 of 213), from greater than 0 to less than 5 mm in 40.4% (86 of 213), and greater than or equal to 5 mm in 45.1% (96 of 213). The 2-year cumulative incidence of local disease progression was 72% for 0 mm and 12% for greater than 0 to less than 5 mm. No local disease progression was observed for an MAM greater than or equal to 5 mm. Among 117 tumors with an MAM less than 5 mm, 36 had local disease progression and 30 were spatially localized within the tissue at risk for tumor progression. On multivariable analysis, an MAM of 0 mm (subdistribution hazard ratio, 23.3; 95% CI: 10.8, 50.5; P < .001) was independently associated with local disease progression. Conclusion Biomechanical deformable image registration and autosegmentation on CT images enabled identification and spatial localization of colorectal liver metastases at risk for local disease progression following ablation, with a minimal ablative margin greater than or equal to 5 mm as the optimal end point. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Sofocleous in this issue.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/patologia , Tomografia Computadorizada por Raios X/métodos , Progressão da Doença
5.
Cardiovasc Intervent Radiol ; 45(12): 1860-1867, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36058995

RESUMO

PURPOSE: This study aims to evaluate the intra-procedural use of a novel ablation confirmation (AC) method, consisting of biomechanical deformable image registration incorporating AI-based auto-segmentation, and its impact on tumor coverage by quantitative three-dimensional minimal ablative margin (MAM) CT-generated assessment. MATERIALS AND METHODS: This single-center, randomized, phase II, intent-to-treat trial is enrolling 100 subjects with primary and secondary liver tumors (≤ 3 tumors, 1-5 cm in diameter) undergoing microwave or radiofrequency ablation with a goal of achieving ≥ 5 mm MAM. For the experimental arm, the proposed novel AC method is utilized for ablation applicator(s) placement verification and MAM assessment. For the control arm, the same variables are assessed by visual inspection and anatomical landmarks-based quantitative measurements aided by co-registration of pre- and post-ablation contrast-enhanced CT images. The primary objective is to evaluate the impact of the proposed AC method on the MAM. Secondary objectives are 2-year LTP-free survival, complication rates, quality of life, liver function, other oncological outcomes, and impact of AC method on procedure workflow. DISCUSSION: The COVER-ALL trial will provide information on the role of a biomechanical deformable image registration-based ablation confirmation method incorporating AI-based auto-segmentation for improving MAM, which might translate in improvements of liver ablation efficacy. CONCLUSION: The COVER-ALL trial aims to provide information on the role of a novel intra-procedural AC method for improving MAM, which might translate in improvements of liver ablation efficacy. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT04083378.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Neoplasias Hepáticas , Humanos , Técnicas de Ablação/métodos , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Qualidade de Vida , Resultado do Tratamento
6.
AMA J Ethics ; 23(2): E140-145, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33635194

RESUMO

Institutional racism is a set of practices and policies that disadvantage individuals not part of societies' dominant groups. In academic health centers (AHCs), institutional racism mediates structural racism; it is embedded in institutional policies, clinical practice, health professional training, and biomedical research. Measuring institutional racism in AHCs at the individual, intra-organizational, and extra-organizational levels renders visible how AHCs mediate structural racism by implementing policies that unfairly treat minority groups.


Assuntos
Racismo , Pessoal de Saúde , Humanos , Grupos Minoritários , Organizações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA