Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Sensors (Basel) ; 24(18)2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39338724

RESUMO

An advanced process for the manufacturing of aerogel-lined capillaries is presented; these are applicable as liquid-core waveguides for gaining the Raman signal of aqueous samples. With respect to the spin-coating process we have used so far for the manufacturing of aerogel-lined capillaries, the here-presented manufacturing process is advanced as it enables (i) the lining of longer capillaries, (ii) the adjustment of the lining-thickness via the lining velocity, and (iii) the reproducible generation of crack-free linings. The key parameters of the advanced process and their effect on the fabrication of aerogel-lined capillaries with optimal Raman signal gain are reported and related to the thickness and topography of the aerogel linings by the support of scanning electron microscopy.

2.
Polymers (Basel) ; 16(15)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39125244

RESUMO

This study aims to establish and optimize a process for the fabrication of 3D microstructures of the biocompatible polymer Parylene C using hot embossing techniques. The different process parameters such as embossing temperature, embossing force, demolding temperature and speed, and the usage of a release agent were optimized, utilizing adhesive micropillars as a use case. To enhance compatibility with conventional semiconductor fabrication techniques, hot embossing of Parylene C was adapted from conventional stainless steel substrates to silicon chip platforms. Furthermore, this adaptation included an investigation of the effects of the hot embossing process on metal layers embedded in the Parylene C, ensuring compatibility with the ultra-thin Parylene printed circuit board (PCB) demonstrated previously. To evaluate the produced microstructures, a combination of characterization methods was employed, including light microscopy (LM) and scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and Fourier-transform infrared spectroscopy (FTIR). These methods provided comprehensive insights into the morphological, chemical, and structural properties of the embossed Parylene C. Considering the improved results compared to existing patterning techniques for Parylene C like plasma etching or laser ablation, the developed hot embossing approach yields a superior structural integrity, characterized by increased feature resolution and enhanced sidewall smoothness. These advancements render the method particularly suitable for diverse applications, including but not limited to, sensor optical components, adhesive interfaces for medical wearables, and microfluidic systems.

3.
Biomimetics (Basel) ; 9(6)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38921236

RESUMO

In this study, a facile approach for simultaneous determination of dopamine (DA) and tryptophan (TRP) using a 3D goethite-spongin-modified carbon paste electrode is reported. The prepared electrode exhibited excellent electrochemical catalytic activity towards DA and TRP oxidation. The electrochemical sensing of the modified electrode was investigated using cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy. Through differential pulse voltammetry analysis, two well-separated oxidation peaks were observed at 28 and 77 mV, corresponding to the oxidation of DA and TRP at the working electrode, with a large peak separation of up to 490 mV. DA and TRP were determined both individually and simultaneously in their dualistic mixture. As a result, the anodic peak currents and the concentrations of DA and TRP were found to exhibit linearity within the ranges of 4-246 µM for DA and 2 to 150 µM for TRP. The detection limits (S/N = 3) as low as 1.9 µM and 0.37 µM were achieved for DA and TRP, respectively. The proposed sensor was successfully applied to the simultaneous determination of DA and TRP in human urine samples with satisfactory recoveries (101% to 116%).

4.
Macromol Biosci ; 24(6): e2300556, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38459913

RESUMO

Cellulose ferulate, synthesized by Mitsunobu reaction, is shaped into thin films and also used as an aqueous dispersion to perform artificial lignin polymerization on anchor groups. This biomimetic approach is carried out in a Quartz crystal microbalance with a dissipation monitoring (QCM-D) device to enable online monitoring of the dehydrogenation, applying H2O2 and adsorbed horseradish peroxidase (HRP). The systematic use of phenylpropanoids with different oxidation states, i.e., ferulic acid, coniferyl aldehyde, coniferyl alcohol, and eugenol allowed to conclude structure-property relationships. Both the deposited material, as well as the surface roughness increased with the hydrophobicity of the monomers. Beyond surface characterizations, py-GC-MS, HSQC NMR spectroscopy and Size exclusion chromatography (SEC) measurements revealed the linkage types ß-ß, ß-5, 5-5, and ß-O-4, as well as the oligomeric character of the dehydrogenation products. All samples possessed an antibacterial activity against B. subtilis and can be used in the field of antimicrobial biomaterials.


Assuntos
Celulose , Lignina , Lignina/química , Celulose/química , Peróxido de Hidrogênio/química , Hidrogenação , Ácidos Cumáricos/química , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Biomimética/métodos , Materiais Biomiméticos/química , Materiais Biomiméticos/farmacologia , Técnicas de Microbalança de Cristal de Quartzo , Antibacterianos/farmacologia , Antibacterianos/química , Propriedades de Superfície , Fenóis
5.
Spectrochim Acta A Mol Biomol Spectrosc ; 313: 124057, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38457872

RESUMO

A simple, highly sensitive, and selective fluorometric aptasensing platform based on aptamer and graphene oxide (GO) is proposed for the determination of mercury (II) ion (Hg2+). In the designed assay, two aptamer probes, a carboxy-fluorescein (FAM) labeled aptamer (aptamer A) and its complementary (aptamer B) with partial complement containing several mismatches and GO as the quencher were used. In the absence of Hg2+, both A and B aptamers were adsorbed on the surface of GO by π-π-stacking, leading to fluorescence quenching of FAM due to fluorescence resonance energy transfer (FRET). Upon exposure to Hg2+, the A and B aptamer strands bind Hg2+ and form T-Hg2+-T complexes, leading to the formation of a stable double-stranded aptamer. The double-stranded aptamer is detached from the GO surface, resulting in the recovery of FAM fluorescence. The fluorescence intensity (FI) of the developed sensor was correlated with the Hg2+ concentration under optimized experimental conditions in two wide linear ranges, even in the presence of 10 divalent cations as interferences. The linear ranges were obtained from 200.0 to 900.0 fM and 5.0 to 33.0 pM, a limit of detection (LOD) of 106.0 fM, and a limit of quantification (LOQ) of 321.3 fM. The concentration of Hg2+ was determined in five real samples containing three water and two serum samples, using spiking and standard addition methods and the results were compared with the spiked amounts and atomic absorption (AAS) as standard method respectively, with acceptable recoveries. Furthermore, in the standard addition method, to overcome the effects of matrix influence of real samples in quantitative predictions, the excitation-emission matrix (EEM) data for samples was simultaneously analyzed by multivariate curve resolution with alternating least squares (MCR-ALS) as a second-order standard addition method (SOSAM).


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Grafite , Mercúrio , Transferência Ressonante de Energia de Fluorescência/métodos , Fluorometria/métodos , Água , Limite de Detecção , Oligonucleotídeos , Técnicas Biossensoriais/métodos , Aptâmeros de Nucleotídeos/metabolismo
6.
Biomimetics (Basel) ; 8(7)2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37999174

RESUMO

The structural biopolymer spongin in the form of a 3D scaffold resembles in shape and size numerous species of industrially useful marine keratosan demosponges. Due to the large-scale aquaculture of these sponges worldwide, it represents a unique renewable source of biological material, which has already been successfully applied in biomedicine and bioinspired materials science. In the present study, spongin from the demosponge Hippospongia communis was used as a microporous template for the development of a new 3D composite containing goethite [α-FeO(OH)]. For this purpose, an extreme biomimetic technique using iron powder, crystalline iodine, and fibrous spongin was applied under laboratory conditions for the first time. The product was characterized using SEM and digital light microscopy, infrared and Raman spectroscopy, XRD, thermogravimetry (TG/DTG), and confocal micro X-ray fluorescence spectroscopy (CMXRF). A potential application of the obtained goethite-spongin composite in the electrochemical sensing of dopamine (DA) in human urine samples was investigated, with satisfactory recoveries (96% to 116%) being obtained.

7.
Mar Drugs ; 21(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37755073

RESUMO

Marine sponges of the subclass Keratosa originated on our planet about 900 million years ago and represent evolutionarily ancient and hierarchically structured biological materials. One of them, proteinaceous spongin, is responsible for the formation of 3D structured fibrous skeletons and remains enigmatic with complex chemistry. The objective of this study was to investigate the interaction of spongin with iron ions in a marine environment due to biocorrosion, leading to the occurrence of lepidocrocite. For this purpose, a biomimetic approach for the development of a new lepidocrocite-containing 3D spongin scaffold under laboratory conditions at 24 °C using artificial seawater and iron is described for the first time. This method helps to obtain a new composite as "Iron-Spongin", which was characterized by infrared spectroscopy and thermogravimetry. Furthermore, sophisticated techniques such as X-ray fluorescence, microscope technique, and X-Ray diffraction were used to determine the structure. This research proposed a corresponding mechanism of lepidocrocite formation, which may be connected with the spongin amino acids functional groups. Moreover, the potential application of the biocomposite as an electrochemical dopamine sensor is proposed. The conducted research not only shows the mechanism or sensor properties of "Iron-spongin" but also opens the door to other applications of these multifunctional materials.


Assuntos
Ferro , Poríferos , Animais , Biomimética , Dopamina
8.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36772521

RESUMO

Although tremendous progress has been made in treating childhood cancer, it is still one of the leading causes of death in children worldwide. Because cancer symptoms overlap with those of other diseases, it is difficult to predict a tumor early enough, which causes cancers in children to be more aggressive and progress more rapidly than in adults. Therefore, early and accurate detection methods are urgently needed to effectively treat children with cancer therapy. Identification and detection of cancer biomarkers serve as non-invasive tools for early cancer screening, prevention, and treatment. Biosensors have emerged as a potential technology for rapid, sensitive, and cost-effective biomarker detection and monitoring. In this review, we provide an overview of important biomarkers for several common childhood cancers. Accordingly, we have enumerated the developed biosensors for early detection of pediatric cancer or related biomarkers. This review offers a restructured platform for ongoing research in pediatric cancer diagnostics that can contribute to the development of rapid biosensing techniques for early-stage diagnosis, monitoring, and treatment of children with cancer and reduce the mortality rate.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Criança , Neoplasias/diagnóstico , Biomarcadores , Técnicas Biossensoriais/métodos , Biomarcadores Tumorais , Detecção Precoce de Câncer/métodos
9.
Micromachines (Basel) ; 14(2)2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36838115

RESUMO

Emerging trends like the Internet of Things require an increasing number of different sensors, actuators and electronic devices. To enable new applications, such as wearables and electronic skins, flexible sensor technologies are required. However, established technologies for the fabrication of sensors and actuators, as well as the related packaging, are based on rigid substrates, i.e., silicon wafer substrates and printed circuit boards (PCB). Moreover, most of the flexible substrates investigated until now are not compatible with the aforementioned fabrication technologies on wafers due to their lack of chemical inertness and handling issues. In this presented paper, we demonstrate a conceptually new approach to transfer structures, dies, and electronic components to a flexible substrate by lift-off. The structures to be transferred, including the related electrical contacts and packaging, are fabricated on a rigid carrier substrate, coated with the flexible substrate and finally lifted off from the carrier. The benefits of this approach are the combined advantages of using established semiconductor and microsystem fabrication technologies as well as packaging technologies, such as high precision and miniaturization, as well as a variety of available materials and processes together with those of flexible substrates, such as a geometry adaptivity, lightweight structures and low costs.

10.
Biosensors (Basel) ; 13(2)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36832028

RESUMO

Gallic acid (GA) is one of the most important polyphenols, being widely used in the food, cosmetic, and pharmaceutical industries due to its biological effects such as antioxidant, antibacterial, anticancer, antiviral, anti-inflammatory, and cardioprotective properties. Hence, simple, fast, and sensitive determination of GA is of particular importance. Considering the fact that GA is an electroactive compound, electrochemical sensors offer great potential for GA quantitation due to their fast response time, high sensitivity, and ease of use. A simple, fast, and sensitive GA sensor was fabricated on the basis of a high-performance bio-nanocomposite using spongin as a natural 3D polymer, atacamite, and multi-walled carbon nanotubes (MWCNTs). The developed sensor showed an excellent response toward GA oxidation with remarkable electrochemical features due to the synergistic effects of 3D porous spongin and MWCNTs, which provide a large surface area and enhance the electrocatalytic activity of atacamite. At optimal conditions by differential pulse voltammetry (DPV), a good linear relationship was obtained between peak currents and GA concentrations in a wild linear range of 500 nM to 1 mM. Subsequently, the proposed sensor was used to detect GA in red wine as well as in green and black tea, confirming its great potential as a reliable alternative to conventional methods for GA determination.


Assuntos
Nanocompostos , Nanotubos de Carbono , Ácido Gálico/análise , Nanotubos de Carbono/química , Técnicas Eletroquímicas/métodos , Bebidas , Nanocompostos/química , Eletrodos , Limite de Detecção
11.
Spectrochim Acta A Mol Biomol Spectrosc ; 293: 122448, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36773423

RESUMO

Mercury is a highly toxic and potentially bioaccumulative heavy metal ion that can cause severe health problems in humans even at very low concentrations. Thus, the development of a simple, rapid, and sensitive assay for the effective detection of mercury ions at trace levels is of great importance. Here, nitrogen and sulfur co-doped carbon quantum dots (N,S-CQD) were synthesized by a simple hydrothermal treatment of chitosan in the presence of thiourea and citric acid with a quantum yield (QY) up to 33.0 % and used as a selective fluorescent probe to detect mercury ions (Hg2+). The effect of pH, ionic strength, and time on the fluorescence intensity of N,S-CQD were investigated and optimized. The synthesized N,S-CQD showed ultrasensitive ability to detect Hg2+ ions in the water samples, also in the presence of 11 interfering metal ions, with a low detection limit (∼4 nM) over a wide linear range from ∼5-160 nM. The sensing performance of N,S-CQD probe in real sample applications was evaluated by the detection of Hg2+ in lake water samples, which confirmed its potential application in environmental analysis.

12.
Polymers (Basel) ; 14(23)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36501649

RESUMO

The polymer Parylene combines a variety of excellent properties and, hence, is an object of intensive research for packaging applications, such as the direct encapsulation of medical implants. Moreover, in the past years, an increasing interest for establishing new applications for Parylene is observed. These include the usage of Parylene as a flexible substrate, a dielectric, or a material for MEMS, e.g., a bonding adhesive. The increasing importance of Parylene raises questions regarding the long-term reliability and aging of Parylene as well as the impact of the aging on the Parylene properties. Within this paper, we present the first investigations on non-accelerated Parylene C aging for a period of about five years. Doing so, free-standing Parylene membranes were fabricated to investigate the barrier properties, the chemical stability, as well as the optical properties of Parylene in dependence on different post-treatments to the polymer. These properties were found to be excellent and with only a minor age-related impact. Additionally, the mechanical properties, i.e., the Young's modulus and the hardness, were investigated via nano-indentation over the same period of time. For both mechanical properties only, minor changes were observed. The results prove that Parylene C is a highly reliable polymer for applications that needs a high long-term stability.

13.
Biomacromolecules ; 23(5): 2089-2097, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35438964

RESUMO

Thin films of cellulose ferulate were designed to study the formation of dehydrogenation polymers (DHPs) on anchor groups of the surface. Trimethylsilyl (TMS) cellulose ferulate with degree of substitution values of 0.35 (ferulate) and 2.53 (TMS) was synthesized by sophisticated polysaccharide chemistry applying the Mitsunobu reaction. The biopolymer derivative was spin-coated into thin films to yield ferulate moieties on a smooth cellulose surface. Dehydrogenative polymerization of coniferyl alcohol was performed in a Quartz crystal microbalance with a dissipation monitoring device in the presence of H2O2 and adsorbed horseradish peroxidase. The amount of DHP formed on the surface was found to be independent of the base layer thickness from 14 to 75 nm. Pyrolysis-GC-MS measurements of the DHP revealed ß-O-4 and ß-5 linkages. Mimicking lignification of plant cell walls on highly defined model films enables reproducible investigations of structure-property relationships.


Assuntos
Celulose , Lignina , Celulose/química , Peroxidase do Rábano Silvestre/química , Peróxido de Hidrogênio/química , Lignina/química , Polimerização
14.
ACS Appl Bio Mater ; 5(2): 873-880, 2022 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-35050590

RESUMO

The design of sensitive and cost-effective biocomposite materials with high catalytic activity for the effective electrooxidation of glucose plays a key role in developing enzyme-free glucose sensors. The porous three-dimensional (3D) spongin scaffold of marine sponge origin provides an excellent template for the growth of atacamite crystals and improves the activity of atacamite as a catalyst. By using the design of experiment method, the influence of different parameters on the electrode efficiency was optimized. The optimized sensor based on spongin-atacamite showed distinguished performance toward glucose with two linear ranges of 0.4-200 µM and 0.2-10 mM and high sensitivities of 3908.4 and 600.5 µA mM-1 cm-2, respectively. Importantly, the designed sensor exhibited strong selectivity and favorable stability, reproducibility, and repeatability. The performance in the real application was estimated by glucose detection in spiked human blood serum samples, which verified its great potential as a reliable platform for enzyme-free glucose sensing.


Assuntos
Cobre , Técnicas Eletroquímicas , Cloretos , Cobre/química , Técnicas Eletroquímicas/métodos , Glucose , Reprodutibilidade dos Testes
15.
Sensors (Basel) ; 21(21)2021 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-34770300

RESUMO

The functionality of products increases when more sensors are used. This trend also affects future automobiles and becomes even more relevant in connected and autonomous applications. Concerning automotive lightweight design, carbon fibre-reinforced polymers (CFRP) are suitable materials. However, their drawbacks include the relatively high manufacturing costs of CFRP components in addition to the difficulty of recycling. To compensate for the increased expenditure, the integration of automotive sensors in CFRP vehicle structures provides added value. As a new approach, established sensors are integrated into fibre-reinforced polymer (FRP) structures. The sensors are usually mounted to the vehicle. The integration of sensors into the structure saves weight and space. Many other approaches specifically develop new sensors for integration into FRP structures. With the new approach, there is no need for elaborate development of new sensors since established sensors are used. The present research also showed that the range of applications of the sensors can be extended by the integration. The present paper outlines the functional behaviour of the integrated sensor utilized for crashing sensing. First of all, the integration quality of the sensor is relevant. Different requirements apply to the usual mounting of the sensor. The self-sensing structure must fulfil those requirements. Moreover, unfamiliar characteristics of the new surrounding structure might affect the sensing behaviour. Thus, the sensing behaviour of the self-sensing composite was analyzed in detail. The overarching objective is the general integration of sensors in products with reasonable effort.


Assuntos
Polímeros , Reciclagem , Automóveis , Fibra de Carbono
16.
Biomedicines ; 9(8)2021 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-34440168

RESUMO

Primary liver cancer is an aggressive, lethal malignancy that ranks as the fourth leading cause of cancer-related death worldwide. Its 5-year mortality rate is estimated to be more than 95%. This significant low survival rate is due to poor diagnosis, which can be referred to as the lack of sufficient and early-stage detection methods. Many liver cancer-associated non-coding RNAs (ncRNAs) have been extensively examined to serve as promising biomarkers for precise diagnostics, prognostics, and the evaluation of the therapeutic progress. For the simple, rapid, and selective ncRNA detection, various nanomaterial-enhanced biosensors have been developed based on electrochemical, optical, and electromechanical detection methods. This review presents ncRNAs as the potential biomarkers for the early-stage diagnosis of liver cancer. Moreover, a comprehensive overview of recent developments in nanobiosensors for liver cancer-related ncRNA detection is provided.

17.
Adv Mater ; 33(30): e2101682, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34085323

RESUMO

The design of new composite materials using extreme biomimetics is of crucial importance for bioinspired materials science. Further progress in research and application of these new materials is impossible without understanding the mechanisms of formation, as well as structural features at the molecular and nano-level. It presents a challenge to obtain a holistic understanding of the mechanisms underlying the interaction of organic and inorganic phases under conditions of harsh chemical reactions for biopolymers. Yet, an understanding of these mechanisms can lead to the development of unusual-but functional-hybrid materials. In this work, a key way of designing centimeter-scale macroporous 3D composites, using renewable marine biopolymer spongin and a model industrial solution that simulates the highly toxic copper-containing waste generated in the production of printed circuit boards worldwide, is proposed. A new spongin-atacamite composite material is developed and its structure is confirmed using neutron diffraction, X-ray diffraction, high-resolution transmission electron microscopy/selected-area electron diffraction, X-ray photoelectron spectroscopy, near-edge X-ray absorption fine structure spectroscopy, and electron paramagnetic resonance spectroscopy. The formation mechanism for this material is also proposed. This study provides experimental evidence suggesting multifunctional applicability of the designed composite in the development of 3D constructed sensors, catalysts, and antibacterial filter systems.


Assuntos
Materiais Biomiméticos/química , Biopolímeros/química , Cloretos/química , Cobre/química , Nanocompostos/química , Poluição Química da Água/prevenção & controle , Amônia/química , Catálise , Humanos , Conformação Molecular , Oxirredução , Porosidade , Impressão Tridimensional , Relação Estrutura-Atividade
18.
Sensors (Basel) ; 21(9)2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-34068640

RESUMO

Composites of organic compounds and inorganic nanomaterials provide novel sensing platforms for high-performance sensor applications. The combination of the attractive functionalities of nanomaterials with polymers as an organic matrix offers promising materials with tunable electrical, mechanical, and chemisensitive properties. This review mainly focuses on nanocarbon/polymer composites as chemiresistors. We first describe the structure and properties of carbon nanofillers as reinforcement agents used in the manufacture of polymer composites and the sensing mechanism of developed nanocomposites as chemiresistors. Then, the design and synthesizing methods of polymer composites based on carbon nanofillers are discussed. The electrical conductivity, mechanical properties, and the applications of different nanocarbon/polymer composites for the detection of different analytes are reviewed. Lastly, challenges and the future vision for applications of such nanocomposites are described.

19.
Sensors (Basel) ; 21(7)2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807242

RESUMO

Globally, there is growing concern about the health risks of water and air pollution. The U.S. Environmental Protection Agency (EPA) has developed a list of priority pollutants containing 129 different chemical compounds. All of these chemicals are of significant interest due to their serious health and safety issues. Permanent exposure to some concentrations of these chemicals can cause severe and irrecoverable health effects, which can be easily prevented by their early identification. Molecularly imprinted polymers (MIPs) offer great potential for selective adsorption of chemicals from water and air samples. These selective artificial bio(mimetic) receptors are promising candidates for modification of sensors, especially disposable sensors, due to their low-cost, long-term stability, ease of engineering, simplicity of production and their applicability for a wide range of targets. Herein, innovative strategies used to develop MIP-based sensors for EPA priority pollutants will be reviewed.

20.
Carbohydr Polym ; 258: 117719, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33593581

RESUMO

This study reports developing novel smart drug delivery systems (DDS) that have great importance in anticancer therapeutics. The magnetic hydroxypropyl methylcellulose (mHPMC) synthesized via in situ method and introduced in the fabrication of tripolyphosphate (TPP)-cross-linked chitosan core-shell nano-carriers (mHPMC@Chitosan). The TPP-cross-linked mHPMC@Chitosan nano-carriers then characterized using TEM, SEM/EDS, DLS, XPS, FTIR, TGA, XRD, and VSM. The encapsulation efficiency showed high capacity of loading for sunitinib malate (above 86 % for all samples). At pH 7.4, the minimum content of drug release was observed for all samples fabricated with variable contents of chitosan. At pH 4.5, the effect of chitosan content revealed that the rate of sunitinib release tends to decrease as its content increased. During two days, 44 and 93 % of the loaded sunitinib released from carriers containing high and low contents of chitosan, respectively. Besides, this mHPMC@Chitosan core shell nano-carrier shown pH-sensitive drug release.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA