Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Bioanalysis ; 16(3): 121-128, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38226833

RESUMO

Aim: This study aimed to develop a colorimetric approach for quantifying ethanol using smartphone image analysis. Method: This research presents a straightforward smartphone-based colorimetric sensor that efficiently measures ethanol levels in exhaled breath condensate (EBC) samples. The process involved changing the acidic dichromate color in an ethanolic solution, followed by image analysis. Results: The results showed that this method was able to estimate ethanol concentrations in the range of 300-1500 and 1600-8000 µg ml-1 in EBC. Conclusion: This study was a follow-up study on the previous work published for the determination of ethanol in EBC samples and highlights the potential benefits of using digital images and smartphone applications for ethanol determination in biological samples.


Assuntos
Testes Respiratórios , Colorimetria , Seguimentos , Testes Respiratórios/métodos , Biomarcadores/análise , Expiração
2.
AAPS PharmSciTech ; 24(7): 207, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37817041

RESUMO

Drug solubility is of central importance to the pharmaceutical sciences, but reported values often show discrepancies. Various factors have been discussed in the literature to account for such differences, but the influence of manual testing in comparison to a robotic system has not been studied adequately before. In this study, four expert researchers were asked to measure the solubility of four drugs with various solubility behaviors (i.e., paracetamol, mesalazine, lamotrigine, and ketoconazole) in the same laboratory with the same instruments, method, and material sources and repeated their measurements after a time interval. In addition, the same solubility data were determined using an automated laser-based setup. The results suggest that manual testing leads to a handling influence on measured solubility values, and the results were discussed in more detail as compared to the automated laser-based system. Within the framework of unavoidable uncertainties of solubility testing, it is a possibility to combine minimal experimental testing that is preferably automated with mathematical modeling. That is a practical suggestion to support future pharmaceutical development in a more efficient way.


Assuntos
Procedimentos Cirúrgicos Robóticos , Solubilidade , Cetoconazol , Anticonvulsivantes , Lasers , Preparações Farmacêuticas
3.
RSC Adv ; 13(43): 30562-30574, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37860171

RESUMO

This article presents a solid-phase extraction method combined with a spectrofluorometric method for the extraction/pre-concentration and determination of metoprolol (MET) in exhaled breath condensate. The extraction sorbent is an agarose aerogel nanocomposite grafted with graphene oxide (GO) Fe3O4. The size and morphology of the nanosorbent were characterized via X-ray crystallography, scanning electron microscopy, Fourier-transform infrared spectrometry, and Brunauer-Emmett-Teller analysis. Factors affecting the extraction/determination of MET were optimized using the one-at-a-time method. Under optimized experimental conditions, the calibration graph was linear in the range of 0.005 to 2.0 µg mL-1 with a detection limit of 0.001 µg mL-1. The method was successfully applied for the determination of MET in biological samples taken from patients receiving MET.

4.
Phys Chem Chem Phys ; 25(35): 23358-23369, 2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37615695

RESUMO

Chemiresistive gas sensors are metal oxide-based sensors that have received significant attention in different fields. Ambient gas sensors are especially important in the fabrication of wearable probes for the real-time detection of biomarkers in human body samples. Usually, room temperature sensors are affordable due to their low power consumption, resulting in simple instrumentation and maintenance. To fabricate versatile gas sensors, i.e. sensitive, selective, ambient temperature operating gas sensors, and improve the sensing performance of the traditionally used sensor, new materials play an important role. In other words, new advanced materials are essential for designing and fabricating new gas sensors. Hence, in this review, the application and impact of new advanced materials in the fabrication of reliable gas sensors are discussed in detail. Special emphasis is given to the effect of new materials in the fabrication of room-temperature operating systems. Finally, future research outlook and possible challenges that may be encountered by reliable gas sensors are also explained.

5.
J Pharm Biomed Anal ; 235: 115641, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37647795

RESUMO

Breath analysis is an effective method of monitoring systemic or respiratory ailments. A simple chiral capillary electrophoresis method coupled with an online field-amplified sample injection stacking method is presented for ultratrace quantification of the enantiomers of ofloxacin in exhaled breath condensate (EBC). The study is focused on the use of EBC as an easily available biological sample to monitor ofloxacin's enantiomers levels with good patient compliance. The proposed method was validated in accordance with FDA guidelines over the concentration range of 0.004-1.0 µg mL-1 of racemic ofloxacin. Inter- and intra-day precision and accuracy were within the acceptable limit (below 8.50 %). The method was specific for routine analysis of ofloxacin's enantiomers. A small volume of EBC samples from seven patients under ofloxacin therapy was analyzed using the proposed method in which the concentrations of "R" and "S" enantiomers were between 0.0026 and 0.056 µg mL-1.


Assuntos
Testes Respiratórios , Eletroforese Capilar , Humanos , Ofloxacino
6.
Bioanalysis ; 15(15): 915-926, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37431823

RESUMO

Aim: A colorimetric approach for quantification of lamotrigine using spectrophotometric and smartphone image analysis is described in this study. Methods: For full optimization and validation procedures, UV-visible spectroscopy was used, and image analysis was carried out with the help of an app (PhotoMetrix PRO®). Then, as a multivariate calibration method, parallel factor analysis was used for data analysis. Results: The results demonstrated the capacity of these methods to estimate lamotrigine concentrations in the range of 0.1-7.0 µg.ml-1 in exhaled breath condensate, indicating the value of using digital images and smartphone applications in combination with chemometric tools. Conclusion: The image analysis can be superior for its fast and reliable lamotrigine analysis in biological samples.


Assuntos
Nanopartículas , Smartphone , Lamotrigina , Colorimetria/métodos , Anticonvulsivantes
7.
J Pharm Pharm Sci ; 26: 11466, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37206631

RESUMO

Purpose: An efficient, cost-effective and non-invasive test is required to overcome the challenges faced in the process of bioequivalence (BE) studies of various orally inhaled drug formulations. Two different types of pressurized meter dose inhalers (MDI-1 and MDI-2) were used in this study to test the practical applicability of a previously proposed hypothesis on the BE of inhaled salbutamol formulations. Methods: Salbutamol concentration profiles of the exhaled breath condensate (EBC) samples collected from volunteers receiving two inhaled formulations were compared employing BE criteria. In addition, the aerodynamic particle size distribution of the inhalers was determined by employing next generation impactor. Salbutamol concentrations in the samples were determined using liquid and gas chromatographic methods. Results: The MDI-1 inhaler induced slightly higher EBC concentrations of salbutamol when compared with MDI-2. The geometric MDI-2/MDI-1 mean ratios (confidence intervals) were 0.937 (0.721-1.22) for maximum concentration and 0.841 (0.592-1.20) for area under the EBC-time profile, indicating a lack of BE between the two formulations. In agreement with the in vivo data, the in vitro data indicated that the fine particle dose (FPD) of MDI-1 was slightly higher than that for the MDI-2 formulation. However, the FPD differences between the two formulations were not statistically significant. Conclusion: EBC data of the present work may be considered as a reliable source for assessment of the BE studies of orally inhaled drug formulations. However, more detailed investigations employing larger sample sizes and more formulations are required to provide more evidence for the proposed method of BE assay.


Assuntos
Albuterol , Nebulizadores e Vaporizadores , Humanos , Projetos Piloto , Equivalência Terapêutica , Administração por Inalação
8.
RSC Adv ; 13(17): 11457-11463, 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37063715

RESUMO

In the current study, bismuth ferrite nano-sorbent was synthesized and utilized as a sorbent for the dispersive solid-phase extraction of methylprednisolone from exhaled breath samples. The size and morphology of the nano-sorbent were characterized by X-ray diffraction analysis and scanning electron microscopy. Following its desorption with acetonitrile, methylprednisolone was quantified by a high-performance liquid chromatography-ultraviolet detector. Factors affecting the extraction of methylprednisolone were optimized. Under optimized experimental conditions, a linear relationship between the analytical signals and methylprednisolone concentration was obtained in the range of 0.001-0.2 µg mL-1 for exhaled breath condensate samples and 0.002-0.4 µg per filter for filter samples. A pre-concentration factor of 6.4-fold, corresponding to an extraction recovery of 96.0%, was achieved. The validated method was applied for the determination of methylprednisolone in real samples taken from the exhaled breath of COVID-19 patients under mechanical ventilation.

9.
J Pharm Biomed Anal ; 229: 115377, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37018957

RESUMO

A simple and eco-friendly colorimetric sensing method has been developed for the extremely effective detection of propofol in exhaled breath condensate (EBC). In this study, we put forward a Tollens' procedure, in which silver nanoparticles (AgNPs) were produced using propofol as a reducing agent. To verify the in-situ synthesis of AgNPs, the TEM images, and UV-Vis absorbance were recorded in the absence and presence of propofol. The solution turned from a colorless to yellow and deep yellow color due to the surface plasmon resonance absorption band of formed AgNPs. The intensity of nanoparticle absorbance was quantitatively correlated with the propofol concentration. The proposed sensor revealed good linearity over the range of 0.01-0.8 µg mL-1 at 422 nm with the detection limit of 8.8 ng mL-1 under optimum conditions. Finally, the proposed colorimetric sensor was successfully used for the determination of propofol in the EBC sample of patients receiving propofol.


Assuntos
Nanopartículas Metálicas , Propofol , Humanos , Prata , Colorimetria/métodos , Ressonância de Plasmônio de Superfície
10.
J Pharm Biomed Anal ; 223: 115141, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36356404

RESUMO

In the current work, a RLS technique based on ß-cyclodextrin modified gold nanoparticles was validated for phenytoin determination in the exhaled breath condensate. It relies on the complexation of ß-cyclodextrins using -OH groups with amine groups of phenytoin which results in an aggregation-induced Rayleigh light scattering intensity enhancement proportional to phenytoin addition. The method shows a linear relationship with phenytoin concentration in the range of 0.005-0.6 µg.mL-1 with a limit of detection of 0.003 µg.mL-1. The validated Rayleigh light scattering system is successfully used for phenytoin determination in the EBC of patients receiving phenytoin.


Assuntos
Nanopartículas Metálicas , beta-Ciclodextrinas , Humanos , Ouro , Fenitoína
11.
Biosensors (Basel) ; 12(10)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36290911

RESUMO

For the first time, a novel aptamer was designed and utilized for the selective detection of rivaroxaban (RIV) using the integration of bioinformatics with biosensing technology. The selected aptamer with the sequence 5'-TAG GGA AGA GAA GGA CAT ATG ATG ACT CAC AAC TGG ACG AAC GTA CTT ATC CCC CCC AAT CAC TAG TGA ATT-3' displayed a high binding affinity to RIV and had an efficient ability to discriminate RIV from similar molecular structures. A novel label-free electrochemical aptasensor was designed and fabricated through the conjugation of a thiolated aptamer with Au nanoparticles (Au-NPs). Then, the aptasensor was successfully applied for the quantitative determination of RIV in human plasma and exhaled breath condensate (EBC) samples with limits of detection (LODs) of 14.08 and 6.03 nM, respectively. These valuable results provide ample evidence of the green electrogeneration of AuNPs on the surface of electrodes and their interaction with loaded aptamers (based on Au-S binding) towards the sensitive and selective monitoring of RIV in human plasma and EBC samples. This bio-assay is an alternative approach for the clinical analysis of RIV and has improved specificity and affinity. As far as we know, this is the first time that an electrochemical aptasensor has been verified for the recognition of RIV and that allows for the easy, fast, and precise screening of RIV in biological samples.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Ouro/química , Aptâmeros de Nucleotídeos/química , Rivaroxabana , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/química , Limite de Detecção , Eletrodos
12.
J Pharm Biomed Anal ; 219: 114959, 2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-35907318

RESUMO

Tramadol has extracted from the exhaled breath condensate (EBC) samples through the supported liquid membrane consisting of 2-nitrophenyl octyl ether impregnated in the hollow fiber wall, and the lumen of the hollow fiber was filled with 20 µL of an acceptor phase. Under the optimum conditions of the electromembrane extraction, i.e. the stirring speed of 750 rpm, extraction time of 20 min, acceptor pH at 1.0, donor phase pH at 6.0, and an applied voltage of 170 V across the supported liquid membrane, a preconcentration factor of 128-fold with a extraction recovery of 64% was achieved. Acceptable linearity was obtained in the tramadol concentration range of 5-1000 ng mL-1 (R2 = 0.9999) with a limit of detection of 1.5 ng mL-1 and a limit of quantitation of 5 ng mL-1. The relative standard deviations for the intra-day and inter-day replications were obtained between 0.4% and 2.5%. The validated technique was successfully used to determine tramadol in real EBC samples.


Assuntos
Tramadol , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Membranas Artificiais
13.
J Pharm Biomed Anal ; 215: 114761, 2022 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-35429724

RESUMO

In this study, a fluorometric probe based on luminol-terbium coordination polymer nanoparticles (luminol-Tb CP NPs) is validated for the quantification of phenobarbital in the exhaled breath condensate collected from expiratory circuit of the mechanical ventilator (MVEBC). It relies on the coordination of phenobarbital to luminol-Tb CP NPs which casing an aggregation-induced fluorescence enhancement of probe owing to the increasing the system rigidity and the decreasing the nonradiative decay rate. As the increase in response intensity is proportional to phenobarbital amount, a method is offered for its determination in MVEBC. This method presents a linear relationship with phenobarbital concentration in the range of 0.1-10.0 mg.L-1 with a limit of detection of 0.024 mg.L-1 and the relative standard deviation of 3.6%. The proposed method is used in MVEBC of the pre-term newborn babies receiving phenobarbital under mechanical ventilator.


Assuntos
Nanopartículas , Polímeros , Testes Respiratórios/métodos , Humanos , Recém-Nascido , Luminol , Fenobarbital , Térbio
14.
Artigo em Inglês | MEDLINE | ID: mdl-35249462

RESUMO

Exhaled breath condensate (EBC) is used to investigate the efficacy of EBC to detect the genetic mutations in patients with lung cancer. Samples of 5 patients and 5 healthy volunteers were collected. DNA was extracted and used for amplification of hotspot regions of TP53 and KRAS genes by using PCR. We performed the mutation analysis by direct sequencing in all subjects. Detected mutations in EBC samples were compared with those of corresponding tumor tissues and there was complete agreement within the detected mutations in EBC and tumorous tissue. EBC can be used as an efficient and noninvasive source for the assessment of gene mutations in patients with lung cancer.


Assuntos
Testes Respiratórios , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/patologia , Mutação , Projetos Piloto , Reação em Cadeia da Polimerase
15.
J Pharm Biomed Anal ; 191: 113572, 2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-32891041

RESUMO

A microwave-induced air-assisted liquid-liquid microextraction method has been proposed for the pretreatment/quantization of salbutamol in exhaled breath condensate (EBC) samples prior to gas chromatography-mass spectrometry. In this procedure, 1-fluoro-2,4-dinitrobenzene and N,N-diethylethanolammonium chloride: dichloroacetic acid: octanoic acid deep eutectic solvent were exploited as derivatization reagent and extraction solvent, respectively. A mixture of the sample solution and pyridine was transferred into a test tube. Then, a mixture of extraction solvent and derivatization agent was placed at the bottom of the tube. After performing the predetermined extraction cycles in the microextraction method, the mixture was exposed to microwave irradiations to enhance derivatization and extraction efficiencies. The obtained turbid solution was centrifuged and a portion of the sedimented phase was used for quantification of salbutamol. The validated method showed low limits of detection (0.074 and 0.370 µg/L in deionized water and EBC, respectively), quantification (0.246 in deionized water and 1.23 µg/L in EBC), and lower limit of quantification (0.123 and 0.615 µg/L in deionized water and EBC, respectively). The method had appropriate repeatability, accuracy, and stability (expressed as relative standard deviation less than 9%). The developed method was used in quantification of salbutamol in the real samples collected from donors receiving salbutamol spray.


Assuntos
Microextração em Fase Líquida , Albuterol , Cromatografia Gasosa-Espectrometria de Massas , Limite de Detecção , Solventes , Água/análise
16.
Artigo em Inglês | MEDLINE | ID: mdl-32745969

RESUMO

In this work, a microwave-enhanced air-assisted liquid-liquid microextraction method combined with gas chromatography-mass spectrometry has been developed for morphine and oxymorphone assessment in EBC samples. For this purpose, choline chloride-menthol-phenylacetic acid deep eutectic solvent (as an extraction solvent), butyl chloroformate (as a derivatization agent), and picoline (as a catalyst) are used. After performing predetermined extraction cycles in the microextraction method, the obtained cloudy solution is exposed to microwave irradiations to enhance extraction and derivatization efficiencies. The method provided low limits of detection (morphine 2.1 and oxymorphone 1.5 ng mL-1) and quantification (morphine 7.2 and oxymorphone 5.2 ng mL-1) in the EBC samples. The method had proper repeatability, accuracy, and stability expressed as relative standard deviations less than 5.1, 9, and 9%, respectively. The developed method was successfully used to determine morphine and oxymorphone concentrations in the EBC samples of addict patients.


Assuntos
Testes Respiratórios/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Líquida/métodos , Morfina/análise , Oximorfona/análise , Humanos , Limite de Detecção , Modelos Lineares , Micro-Ondas , Morfina/química , Morfina/isolamento & purificação , Oximorfona/química , Oximorfona/isolamento & purificação , Reprodutibilidade dos Testes , Solventes/química
18.
Mikrochim Acta ; 187(3): 186, 2020 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-32088793

RESUMO

A colorimetric nanoprobe was developed for the quantification of tobramycin in exhaled breath condensate (EBC). The nanoprobe consists of silver nanoparticles (Ag NPs) modified with sodium dodecyl sulfate (SDS), which is applied in the presence of sodium metaborate. Characterization of the synthesized SDS-capped Ag NPs by transmission electron microscopy (TEM), Fourier-transform infrared spectroscopy (FT-IR), X-ray powder diffraction (XRD), and energy-dispersive X-ray spectroscopy (EDX) showed that the nanoparticles were well synthesized with nearly uniform size and an average diameter of < 30 nm. Interaction of sodium metaborate with the SDS-capped Ag NPs and tobramycin results in aggregation of the nanoparticles and consequently decreases the absorbance intensity, leading to the production of a new absorbance peak and a color change from yellow to purple. The absorbance intensity was recorded at λmax = 400 nm and 522 nm and λ522/λ400 was used as the analytical signal. The experimental parameters were investigated and optimized using a multivariate optimization method (central composite design). The current nanoprobe gives a linear response for tobramycin from 1.0 to 50.0 ng mL-1 with a detection limit of 0.5 ng mL-1. The intra- and inter-day relative standard deviations for five replicated analyses of 10.0 ng mL-1 tobramycin are 2.8% and 4.2%, respectively. Graphical abstractSchematic representation of SDS-capped silver nanoparticles's response to tobramycin in the presence of sodium metaborate.


Assuntos
Testes Respiratórios/métodos , Colorimetria/métodos , Expiração/fisiologia , Nanopartículas Metálicas/química , Tobramicina/química , Humanos
19.
Artigo em Inglês | MEDLINE | ID: mdl-31608776

RESUMO

There is a growing interest in the tracking of genetic and epigenetic alterations in exhaled breath condensate (EBC) samples. The effects of different procedures on the quality and quantity of DNA in EBC were studied. The results demonstrated that sodium acetate precipitation and oligo (dT) improved the quality of the extracted DNA significantly (p < 0.01). Also, sodium acetate precipitation, using oligo (dT), incubation at 70 °C and SDS treatment increased the quantity of DNA significantly (p < 0.01). These results showed the advantages of the chemical and physical manipulations for improving the quality and quantity of the extracted DNA from EBC samples.


Assuntos
Testes Respiratórios , DNA/isolamento & purificação , Adulto , DNA/química , Expiração , Feminino , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
20.
Daru ; 27(1): 517-524, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30847847

RESUMO

BACKGROUND: This short communication reports a new hypothesis regarding bioequivalence of inhalation products which can potentially provide a reliable means to compare pharmaceutical aerosol formulations and inhalers. METHODS: Available methods regarding the bioequivalence studies, inhaled drugs and advantages of exhaled breath condensate (EBC) samples were reviewed to develop this hypothesis. RESULTS: It is postulated that two inhalation products providing the same drug concentrations in airway lining fluid (ALF) could be considered bioequivalent. The use of EBC tests which reflect ALF composition can be recommended as an alternative to current testing methods for consideration of bioequivalence. CONCLUSION: The methods based on EBC analysis can potentially be applied to bioequivalence study of inhalation products and could reflect drug concentration in ALF. However, experimental studies would be necessary to support or refute this hypothesis on the novel application of EBC to bioequivalence in the future. Graphical abstract In vitro (cascade impactor) and In vivo (EBC concentration) corrolation for inhaled drugs.


Assuntos
Aerossóis/farmacocinética , Administração por Inalação , Testes Respiratórios/métodos , Composição de Medicamentos , Expiração , Humanos , Equivalência Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA