Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heliyon ; 10(11): e32120, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38912445

RESUMO

A straightforward, reliable, and cost-effective spectrofluorimetric approach has been established for the analysis of baloxavir marboxil (BXM) in raw material, tablets, as well as spiked human plasma. The approach relies on BXM's quenching impact on acetoxymercuric fluorescein (AMF) fluorescence intensity. To improve the reaction, factors such as AMF's concentration, solution's pH, diluting solvents, and reaction time were examined and optimized. Linearity, range, accuracy, precision, LOD, and LOQ were all verified in compliance with ICH criteria. The concentration range was shown to be linear between 0.2 and 2 µg/mL. The technique was effectively utilized for BXM analysis in both its tablet as well as spiked human plasma, with mean % recoveries of 101 ± 0.36 and 98.77 ± 0.65, respectively. Two assessment models (AGREE and RGB-12) were used to compare the proposed process's greenness and sustainability to four previously published chromatographic techniques. Higher green and sustainability qualities were declared by the suggested approach than by earlier ones.

2.
Luminescence ; 39(4): e4742, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38637644

RESUMO

A simple, rapid, and low-cost technique was developed to allow reliable analysis of the anti-hepatitis C drug sofosbuvir in bulk, tablet form, and spiked human plasma. This method depends on the ability of sofosbuvir to quench the fluorescence of the newly synthesized 2-amino-3-cyano-4,6-dimethylpyridine (reagent 3). Elemental analysis and spectral data were used to validate the structure of the synthesized reagent. The newly synthesized reagent exhibited a satisfactory level of fluorescence emission at 365 nm after excitation at 247 nm. All experimental variables that might affect the quenching process were analyzed and optimized. Linearity, range, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) were all validated in accordance with the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH) guidelines. The concentration range was shown to be linear between 0.1 and 1.5 µg/mL. The technique was effectively utilized for sofosbuvir analysis in both its tablet dosage form and spiked human plasma, with mean percentage recoveries of 100.13 ± 0.35 and 94.26 ± 1.69, respectively.


Assuntos
Corantes Fluorescentes , Sofosbuvir , Humanos , Espectrometria de Fluorescência/métodos , Comprimidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA