Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 15(11): 1153-1163, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680195

RESUMO

BACKGROUND: Resolute Onyx polymer-based zotarolimus-eluting stents (ZES) were noninferior in safety and effectiveness to BioFreedom polymer-free biolimus A9-coated stents (DCS) in high-bleeding-risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT) followed by single antiplatelet therapy (SAPT) at 1 year. OBJECTIVES: This study reports the final 2-year results of the randomized Onyx ONE trial. METHODS: The Onyx ONE (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy (DAPT) for High-Bleeding Risk Patients) trial randomly assigned HBR patients to treatment with ZES or DCS. Following 1-month DAPT, event-free patients received SAPT (either aspirin or a P2Y12 inhibitor at physician discretion). The primary safety endpoint, a composite of cardiac death, myocardial infarction, or stent thrombosis at 1 year, was determined at 1 year. Rates of primary and secondary endpoints were calculated after final follow-up at 2 years. RESULTS: A total of 1,003 patients were randomly allocated to ZES and 993 patients to DCS. Follow-up was complete in 980 (97.7%) ZES patients and 962 (96.9%) DCS patients at 2 years. The primary safety endpoint occurred in 208 (21.2%) patients in the ZES group and 199 (20.7%) patients in the DCS group (risk difference: 0.5%; 95% CI: -3.1% to 4.2%; P = 0.78) at 2 years without significant differences in individual components of the composite endpoint. The secondary effectiveness endpoint occurred in 217 (22.1%) patients in the ZES group and 202 (21.0%) patients in the DCS group (risk difference: 1.1%; 95% CI: -2.5% to 4.8%; P = 0.54). CONCLUSIONS: Among patients at HBR treated with 1-month DAPT followed by SAPT, the Resolute Onyx polymer-based ZES had similar 2-year outcomes for the primary safety and secondary effectiveness endpoint compared with the BioFreedom polymer-free DCS. (A Randomized Controlled Trial With Resolute Onyx in One Month Dual Antiplatelet Therapy [DAPT] for High-Bleeding Risk Patients [Onyx ONE]; NCT03344653).


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Polímeros , Desenho de Prótese , Stents/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA