Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
J Biomed Opt ; 29(Suppl 3): S33310, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39323492

RESUMO

Significance: Near-infrared spectroscopy (NIRS) is a non-invasive optical method that measures changes in hemoglobin concentration and oxygenation. The measured light intensity is susceptible to reduced signal quality due to the presence of melanin. Aim: We quantify the influence of melanin concentration on NIRS measurements taken with a frequency-domain near-infrared spectroscopy system using 690 and 830 nm. Approach: Using a forehead NIRS probe, we measured 35 healthy participants and investigated the correlation between melanin concentration indices, which were determined using a colorimeter, and several key metrics from the NIRS signal. These metrics include signal-to-noise ratio (SNR), two measurements of oxygen saturation (arterial oxygen saturation, SpO 2 , and tissue oxygen saturation, StO 2 ), and optical properties represented by the absorption coefficient ( µ a ) and the reduced scattering coefficient ( µ s ' ). Results: We found a significant negative correlation between the melanin index and the SNR estimated in oxy-hemoglobin signals ( r s = - 0.489 , p = 0.006 ) and SpO 2 levels ( r s = - 0.413 , p = 0.023 ). However, no significant changes were observed in the optical properties and StO 2 ( r s = - 0.146 , p = 0.44 ). Conclusions: We found that estimated SNR and SpO 2 values show a significant decline and dependence on the melanin index, whereas StO 2 and optical properties do not show any correlation with the melanin index.


Assuntos
Melaninas , Razão Sinal-Ruído , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Melaninas/análise , Melaninas/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Feminino , Adulto , Adulto Jovem , Saturação de Oxigênio/fisiologia , Oxigênio/metabolismo , Oxiemoglobinas/análise , Oximetria/métodos , Hemoglobinas/análise
2.
bioRxiv ; 2024 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-39314381

RESUMO

Bilateral cochlear implant (BiCI) usage makes binaural benefits a possibility for implant users. Yet, limited access to interaural time difference (ITD) cues and reduced saliency of interaural level difference (ILD) cues restricts perceptual benefits of spatially separating a target from masker sounds for BiCI users. Here, we explore whether magnifying ILD cues improves intelligibility of masked speech for BiCI listeners in a "symmetrical-masker" configuration, which controls for long-term positive target-to-masker ratio (TMR) at the ear nearer the target from naturally occurring ILD cues. We magnified ILDs by estimating moment-to-moment ITDs in 1-octave-wide frequency bands, and applying corresponding ILDs to the target-masker mixtures reaching the two ears at each time in each frequency band. We conducted two experiments, one with NH listeners using vocoded stimuli and one with BiCI users. ILD magnification significantly improved intelligibility in both experiments. BiCI listeners showed no benefit of spatial separation between target and maskers with natural ILDs, even for the largest target-masker separation. Because ILD magnification is applied to the mixed signals at each ear, the strategy does not alter the TMR in either ear at any time; improvements to masked speech intelligibility are thus likely from improved perceptual separation of the competing sources.

3.
Biomed Opt Express ; 15(8): 4859-4876, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39347003

RESUMO

Diffuse optical tomography (DOT) enhances the localization accuracy of neural activity measured with electroencephalography (EEG) while preserving EEG's high temporal resolution. However, the spatial resolution of reconstructed activity diminishes for deeper neural sources. In this study, we analyzed DOT-enhanced EEG localization of neural sources modeled at depths ranging from 11-25 mm in simulations. Our findings reveal systematic biases in reconstructed depth related to DOT channel length. To address this, we developed a data-informed method for selecting DOT channels to improve the spatial accuracy of DOT-enhanced EEG reconstruction. Using our method, the average absolute reconstruction depth errors of DOT reconstruction across all depths are 0.9 ± 0.6 mm, 1.2 ± 0.9 mm, and 1.2 ± 1.1 mm under noiseless, low-level noise, and high-level noise conditions, respectively. In comparison, using fixed channel lengths resulted in errors of 2.6 ± 1.5 mm, 5.0 ± 2.6 mm, and 7.3 ± 4.5 mm under the same conditions. Consequently, our method improved the depth accuracy of DOT reconstructions and facilitated the use of more accurate spatial priors for EEG reconstructions, enhancing the overall precision of the technique.

4.
Artigo em Inglês | MEDLINE | ID: mdl-39241005

RESUMO

While existing literature covers significant detail on the physiology of human freediving, the lack of standardized protocols has hindered comparisons due to confounding variables such as exercise and depth. By accounting for these variables, direct depth-dependent impacts on cardiovascular and blood oxygen regulation can be investigated. In this study, depth-dependent effects on 1) cerebral hemodynamic and oxygenation changes, 2) arterial oxygen saturation (SpO2), and 3) heart rate during breath-hold diving without confounding effects of exercise were investigated. Six freedivers (51.0 ± 12.6 years; mean ± s.d.), instrumented with continuous-wave near-infrared spectroscopy for monitoring cerebral hemodynamic and oxygenation measurements, heart rate and SpO2, performed sled-assisted breath-hold dives to 15 m and 42 m. Arterial blood gas tensions were validated through cross-sectional periodic blood sampling. Cerebral hemodynamic changes were characteristic of breath-hold diving, with changes during ascent from both depths likely driven by decreasing SpO2 due to lung expansion. While SpO2 was significantly lower following 42 m dives (t(5) = -4.183, p < 0.05), mean cerebral arterial-venous blood oxygen saturation remained at 74% following dives to both depths. Cerebral oxygenation during ascent from 42 m may have been maintained through increased arterial delivery. Heart rate was variable with no significant difference in minimum heart rate between both depths (t(5) = -1.017, p > 0.05). This study presents a standardized methodology, which could provide a basis for future research on human freediving physiology and uncover ways in which freedivers can reduce potential risks of the sport.

5.
J Biomed Opt ; 29(9): 096001, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39282216

RESUMO

Significance: Near-infrared optical imaging methods have shown promise for monitoring response to neoadjuvant chemotherapy (NAC) for breast cancer, with endogenous contrast coming from oxy- and deoxyhemoglobin. Spatial frequency domain imaging (SFDI) could be used to detect this contrast in a low-cost and portable format, but it has limited imaging depth. It is possible that local tissue compression could be used to reduce the effective tumor depth. Aim: To evaluate the potential of SFDI for therapy response prediction, we aim to predict how changes to tumor size, stiffness, and hemoglobin concentration would be reflected in contrast measured by SFDI under tissue compression. Approach: Finite element analysis of compression on an inclusion-containing soft material is combined with Monte Carlo simulation to predict the measured optical contrast. Results: When the effect of compression on blood volume is not considered, contrast gain from compression increases with the size and stiffness of the inclusion and decreases with the inclusion depth. With a model of reduction of blood volume from compression, compression reduces imaging contrast, an effect that is greater for larger inclusions and stiffer inclusions at shallower depths. Conclusions: This computational modeling study represents a first step toward tracking tumor changes induced by NAC using SFDI and local compression.


Assuntos
Neoplasias da Mama , Método de Monte Carlo , Neoplasias da Mama/diagnóstico por imagem , Humanos , Feminino , Simulação por Computador , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise de Elementos Finitos , Imagem Óptica/métodos , Imagens de Fantasmas , Modelos Biológicos , Hemoglobinas/análise
6.
Biomed Opt Express ; 15(9): 5280-5295, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39296401

RESUMO

Transabdominal fetal pulse oximetry offers a promising approach to improve fetal monitoring and reduce unnecessary interventions. Utilizing realistic 3D geometries derived from MRI scans of pregnant women, we conducted photon simulations to determine optimal source-detector configurations for detecting fetal heart rate and oxygenation. Our findings demonstrate the theoretical feasibility of measuring fetal signals at depths up to 30 mm using source-detector (SD) distances greater than 100 mm and wavelengths between 730 and 850 nm. Furthermore, we highlight the importance of customizing SD configurations based on fetal position and maternal anatomy. These insights pave the way for enhanced non-invasive fetal monitoring in clinical application.

7.
Neurophotonics ; 11(1): 015003, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38250664

RESUMO

Significance: Diffuse correlation spectroscopy (DCS) is an optical method to measure relative changes in cerebral blood flow (rCBF) in the microvasculature. Each heartbeat generates a pulsatile signal with distinct morphological features that we hypothesized to be related to intracranial compliance (ICC). Aim: We aim to study how three features of the pulsatile rCBF waveforms: the augmentation index (AIx), the pulsatility index, and the area under the curve, change with respect to ICC. We describe ICC as a combination of vascular compliance and extravascular compliance. Approach: Since patients with Chiari malformations (CM) (n=30) have been shown to have altered extravascular compliance, we compare the morphology of rCBF waveforms in CM patients with age-matched healthy control (n=30). Results: AIx measured in the supine position was significantly less in patients with CM compared to healthy controls (p<0.05). Since physiologic aging also leads to changes in vessel stiffness and intravascular compliance, we evaluate how the rCBF waveform changes with respect to age and find that the AIx feature was strongly correlated with age (Rhealthy subjects=-0.63, Rpreoperative CM patient=-0.70, and Rpostoperative CM patients=-0.62, p<0.01). Conclusions: These results suggest that the AIx measured in the cerebral microvasculature using DCS may be correlated to changes in ICC.

8.
J Biomed Opt ; 28(11): 115002, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38078151

RESUMO

Significance: Pulse oximetry estimates the arterial oxygen saturation of hemoglobin (SaO2) based on relative changes in light intensity at the cardiac frequency. Commercial pulse oximeters require empirical calibration on healthy volunteers, resulting in limited accuracy at low oxygen levels. An accurate, self-calibrated method for estimating SaO2 is needed to improve patient monitoring and diagnosis. Aim: Given the challenges of calibration at low SaO2 levels, we pursued the creation of a self-calibrated algorithm that can effectively estimate SaO2 across its full range. Our primary objective was to design and validate our calibration-free method using data collected from human subjects. Approach: We developed an algorithm based on diffuse optical spectroscopy measurements of cardiac pulses and the modified Beer-Lambert law (mBLL). Recognizing that the photon mean pathlength (⟨L⟩) varies with SaO2 related absorption changes, our algorithm aligns/fits the normalized ⟨L⟩ (across wavelengths) obtained from optical measurements with its analytical representation. We tested the algorithm with human freedivers performing breath-hold dives. A continuous-wave near-infrared spectroscopy probe was attached to their foreheads, and an arterial cannula was inserted in the radial artery to collect arterial blood samples at different stages of the dive. These samples provided ground-truth SaO2 via a blood gas analyzer, enabling us to evaluate the accuracy of SaO2 estimation derived from the NIRS measurement using our self-calibrated algorithm. Results: The self-calibrated algorithm significantly outperformed the conventional method (mBLL with a constant ⟨L⟩ ratio) for SaO2 estimation through the diving period. Analyzing 23 ground-truth SaO2 data points ranging from 41% to 100%, the average absolute difference between the estimated SaO2 and the ground truth SaO2 is 4.23%±5.16% for our algorithm, significantly lower than the 11.25%±13.74% observed with the conventional approach. Conclusions: By factoring in the variations in the spectral shape of ⟨L⟩ relative to SaO2, our self-calibrated algorithm enables accurate SaO2 estimation, even in subjects with low SaO2 levels.


Assuntos
Oximetria , Oxigênio , Humanos , Oximetria/métodos , Fótons , Luz , Algoritmos
9.
Artigo em Inglês | MEDLINE | ID: mdl-38082980

RESUMO

Recent work has noted a skin-color bias in existing pulse oximetry systems in their estimation of arterial oxygen saturation. Frequently, the algorithm used by these systems estimate a "ratio-of-ratios", called the "R-value", on their way to estimating the oxygen saturation. In this work, we focus on an "SNR-related" bias that is due to noise in measurements. We derive expressions for the SNR-related bias in R-value estimation, and observe how it scales with the signal-to-noise ratio (SNR). We show that the bias can arise at two steps of R-value estimation: in estimating the max and min of a pulsatile signal, and, additionally in taking ratios to estimate the R-value. We assess the bias resulting from the combination of the two steps, but also separate out contributions of each step. By doing so, we deduce that the bias induced in max and min estimation is likely to dominate. Because the SNR tends to get worse with higher melanin concentration, our result provides a sense of scaling of this bias with melanin concentration.


Assuntos
Melaninas , Oxigênio , Razão Sinal-Ruído , Oximetria/métodos , Troca Gasosa Pulmonar
10.
J Biomed Opt ; 28(7): 075001, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37457628

RESUMO

Significance: Using functional near-infrared spectroscopy (fNIRS) in bottlenose dolphins (Tursiops truncatus) could help to understand how echolocating animals perceive their environment and how they focus on specific auditory objects, such as fish, in noisy marine settings. Aim: To test the feasibility of near-infrared spectroscopy (NIRS) in medium-sized marine mammals, such as dolphins, we modeled the light propagation with computational tools to determine the wavelengths, optode locations, and separation distances that maximize sensitivity to brain tissue. Approach: Using frequency-domain NIRS, we measured the absorption and reduced scattering coefficient of dolphin sculp. We assigned muscle, bone, and brain optical properties from the literature and modeled light propagation in a spatially accurate and biologically relevant model of a dolphin head, using finite-element modeling. We assessed tissue sensitivities for a range of wavelengths (600 to 1700 nm), source-detector distances (50 to 120 mm), and animal sizes (juvenile model 25% smaller than adult). Results: We found that the wavelengths most suitable for imaging the brain fell into two ranges: 700 to 900 nm and 1100 to 1150 nm. The optimal location for brain sensing positioned the center point between source and detector 30 to 50 mm caudal of the blowhole and at an angle 45 deg to 90 deg lateral off the midsagittal plane. Brain tissue sensitivity comparable to human measurements appears achievable only for smaller animals, such as juvenile bottlenose dolphins or smaller species of cetaceans, such as porpoises, or with source-detector separations ≫100 mm in adult dolphins. Conclusions: Brain measurements in juvenile or subadult dolphins, or smaller dolphin species, may be possible using specialized fNIRS devices that support optode separations of >100 mm. We speculate that many measurement repetitions will be required to overcome hemodynamic signals originating predominantly from the muscle layer above the skull. NIRS measurements of muscle tissue are feasible today with source-detector separations of 50 mm, or even less.


Assuntos
Golfinho Nariz-de-Garrafa , Humanos , Animais , Adulto , Golfinho Nariz-de-Garrafa/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho , Estudos de Viabilidade , Cabeça
11.
J Theor Biol ; 572: 111580, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37459953

RESUMO

Cortical spreading depolarization (CSD) is a neuropathological condition involving propagating waves of neuronal silence, and is related to multiple diseases, such as migraine aura, traumatic brain injury (TBI), stroke, and cardiac arrest, as well as poor outcome of patients. While CSDs of different severity share similar roots on the ion exchange level, they can lead to different vascular responses (namely spreading hyperemia and spreading ischemia). In this paper, we propose a mathematical model relating neuronal activities to predict vascular changes as measured with near-infrared spectroscopy (NIRS) and fMRI recordings, and apply it to the extreme case of CSD, where sustained near-complete neuronal depolarization is seen. We utilize three serially connected models (namely, ion exchange, neurovascular coupling, and hemodynamic model) which are described by differential equations. Propagating waves of ion concentrations, as well as the associated vasodynamics and hemodynamics, are simulated by solving these equations. Our proposed model predicts vasodynamics and hemodynamics that agree both qualitatively and quantitatively with experimental literature. Mathematical modeling and simulation offer a powerful tool to help understand the underlying mechanisms of CSD and help interpret the data. In addition, it helps develop novel monitoring techniques prior to data collection. Our simulated results strongly suggest that fMRI is unable to reliably distinguish between spreading hyperemia and spreading ischemia, while NIRS signals are substantially distinct in the two cases.


Assuntos
Depressão Alastrante da Atividade Elétrica Cortical , Hiperemia , Acoplamento Neurovascular , Humanos , Acoplamento Neurovascular/fisiologia , Depressão Alastrante da Atividade Elétrica Cortical/fisiologia , Hemodinâmica , Neurônios/fisiologia
12.
Neuroimage ; 277: 120210, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37311535

RESUMO

Electroencephalography (EEG) and diffuse optical tomography (DOT) are imaging methods which are widely used for neuroimaging. While the temporal resolution of EEG is high, the spatial resolution is typically limited. DOT, on the other hand, has high spatial resolution, but the temporal resolution is inherently limited by the slow hemodynamics it measures. In our previous work, we showed using computer simulations that when using the results of DOT reconstruction as the spatial prior for EEG source reconstruction, high spatio-temporal resolution could be achieved. In this work, we experimentally validate the algorithm by alternatingly flashing two visual stimuli at a speed that is faster than the temporal resolution of DOT. We show that the joint reconstruction using both EEG and DOT clearly resolves the two stimuli temporally, and the spatial confinement is drastically improved in comparison to reconstruction using EEG alone.


Assuntos
Tomografia Óptica , Córtex Visual , Humanos , Eletroencefalografia/métodos , Simulação por Computador , Neuroimagem , Algoritmos , Tomografia Óptica/métodos , Córtex Visual/diagnóstico por imagem , Mapeamento Encefálico/métodos
13.
IEEE Open J Eng Med Biol ; 4: 96-101, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37234191

RESUMO

Goal: Cerebrovascular impedance is modulated by a vasoactive autoregulative mechanism in response to changes in cerebral perfusion pressure. Characterization of impedance and the limits of autoregulation are important biomarkers of cerebral health. We developed a method to quantify impedance based on the spectral content of cerebral blood flow and volume at the cardiac frequency, measured with diffuse optical methods. Methods: In three non-human primates, we modulated cerebral perfusion pressure beyond the limits of autoregulation. Cerebral blood flow and volume were measured with diffuse correlation spectroscopy and near-infrared spectroscopy, respectively. Results: We show that impedance can be used to identify the lower and upper limits of autoregulation. Conclusions: This impedance method may be an alternative method to measure autoregulation and a way of assessing cerebral health non-invasively at the clinical bedside.

14.
Neurophotonics ; 10(1): 015002, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36699625

RESUMO

Significance: Cerebrovascular impedance (CVI) is related to cerebral autoregulation (CA), which is the mechanism of the brain to maintain near-constant cerebral blood flow (CBF) despite changes in cerebral perfusion pressure (CPP). Changes in blood vessel impedance enable the stabilization of blood flow. Due to the interplay between CVI and CA, assessment of CVI may enable quantification of CA and may serve as a biomarker for cerebral health. Aim: We developed a method to quantify CVI based on a combination of diffuse correlation spectroscopy (DCS) and continuous wave (CW) near-infrared spectroscopy (NIRS). Data on healthy human volunteers were used to validate the method. Approach: A combined high-speed DCS-NIRS system was developed, allowing for simultaneous, noninvasive blood flow, and volume measurements in the same tissue compartment. Blood volume was used as a surrogate measurement for blood pressure and CVI was calculated as the spectral ratio of blood volume and blood flow changes. This technique was validated on six healthy human volunteers undergoing postural changes to elicit CVI changes. Results: Averaged across the six subjects, a decrease in CVI was found for a head of bed (HOB) tilting of - 40 deg . These impedance changes were reversed when returning to the horizontal (0 deg) HOB baseline. Conclusions: We developed a combined DCS-NIRS system, which measures CBF and volume changes, which we demonstrate can be used to measure CVI. Using CVI as a metric of CA may be beneficial for assessing cerebral health, especially in patients where CPP is altered.

15.
J Neurosurg ; 139(1): 184-193, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36683191

RESUMO

OBJECTIVE: Intracranial pressure (ICP) is an important therapeutic target in many critical neuropathologies. The current tools for ICP measurements are invasive; hence, these are only selectively applied in critical cases where the benefits surpass the risks. To address the need for low-risk ICP monitoring, the authors developed a noninvasive alternative. METHODS: The authors recently demonstrated noninvasive quantification of ICP in an animal model by using morphological analysis of microvascular cerebral blood flow (CBF) measured with diffuse correlation spectroscopy (DCS). The current prospective observational study expanded on this preclinical study by translating the method to pediatric patients. Here, the CBF features, along with mean arterial pressure (MAP) and heart rate (HR) data, were used to build a random decision forest, machine learning model for estimation of ICP; the results of this model were compared with those of invasive monitoring. RESULTS: Fifteen patients (mean age ± SD [range] 9.8 ± 5.1 [0.3-17.5] years; median age [interquartile range] 11 [7.4] years; 10 males and 5 females) who underwent invasive neuromonitoring for any purpose were enrolled. Estimated ICP (ICPest) very closely matched invasive ICP (ICPinv), with a root mean square error (RMSE) of 1.01 mm Hg and 95% limit of agreement of ≤ 1.99 mm Hg for ICPinv 0.01-41.25 mm Hg. When the ICP range (ICPinv 0.01-29.05 mm Hg) was narrowed on the basis of the sample population, both RMSE and limit of agreement improved to 0.81 mm Hg and ≤ 1.6 mm Hg, respectively. In addition, 0.3% of the test samples for ICPinv ≤ 20 mm Hg and 5.4% of the test samples for ICPinv > 20 mm Hg had a limit of agreement > 5 mm Hg, which may be considered the acceptable limit of agreement for clinical validity of ICP sensing. For the narrower case, 0.1% of test samples for ICPinv ≤ 20 mm Hg and 1.1% of the test samples for ICPinv > 20 mm Hg had a limit of agreement > 5 mm Hg. Although the CBF features were crucial, the best prediction accuracy was achieved when these features were combined with MAP and HR data. Lastly, preliminary leave-one-out analysis showed model accuracy with an RMSE of 6 mm Hg and limit of agreement of ≤ 7 mm Hg. CONCLUSIONS: The authors have shown that DCS may enable ICP monitoring with additional clinical validation. The lower risk of such monitoring would allow ICP to be estimated for a wide spectrum of indications, thereby both reducing the use of invasive monitors and increasing the types of patients who may benefit from ICP-directed therapies.


Assuntos
Hipertensão Intracraniana , Pressão Intracraniana , Masculino , Feminino , Humanos , Pressão Intracraniana/fisiologia , Monitorização Fisiológica/métodos , Estudos Prospectivos , Análise Espectral , Hipertensão Intracraniana/diagnóstico , Circulação Cerebrovascular/fisiologia
16.
Biofabrication ; 15(1)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36195056

RESUMO

As 3D bioprinting has grown as a fabrication technology, so too has the need for improved analytical methods to characterize engineered constructs. This is especially challenging for engineered tissues composed of hydrogels and cells, as these materials readily deform when trying to assess print fidelity and other properties non-destructively. Establishing that the 3D architecture of the bioprinted construct matches its intended anatomic design is critical given the importance of structure-function relationships in most tissue types. Here we report development of a multimaterial bioprinting platform with integrated optical coherence tomography forin situvolumetric imaging, error detection, and 3D reconstruction. We also report improvements to the freeform reversible embedding of suspended hydrogels bioprinting process through new collagen bioink compositions, gelatin microparticle support bath optical clearing, and optimized machine pathing. This enables quantitative 3D volumetric imaging with micron resolution over centimeter length scales, the ability to detect a range of print defect types within a 3D volume, and real-time imaging of the printing process at each print layer. These advances provide a comprehensive methodology for print quality assessment, paving the way toward the production and process control required for achieving regulatory approval and ultimately clinical translation of engineered tissues.


Assuntos
Bioimpressão , Impressão Tridimensional , Tomografia de Coerência Óptica , Bioimpressão/métodos , Engenharia Tecidual/métodos , Hidrogéis , Alicerces Teciduais
17.
Neurophotonics ; 9(4): 045001, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36247716

RESUMO

Significance: Intracranial pressure (ICP) measurements are important for patient treatment but are invasive and prone to complications. Noninvasive ICP monitoring methods exist, but they suffer from poor accuracy, lack of generalizability, or high cost. Aim: We previously showed that cerebral blood flow (CBF) cardiac waveforms measured with diffuse correlation spectroscopy can be used for noninvasive ICP monitoring. Here we extend the approach to cardiac waveforms measured with near-infrared spectroscopy (NIRS). Approach: Changes in hemoglobin concentrations were measured in eight nonhuman primates, in addition to invasive ICP, arterial blood pressure, and CBF changes. Features of average cardiac waveforms in hemoglobin and CBF signals were used to train a random forest (RF) regressor. Results: The RF regressor achieves a cross-validated ICP estimation of 0.937 r 2 , 2.703 - mm Hg 2 mean squared error (MSE), and 95% confidence interval (CI) of [ - 3.064 3.160 ] mmHg on oxyhemoglobin concentration changes; 0.946 r 2 , 2.301 - mmHg 2 MSE, and 95% CI of [ - 2.841 2.866 ] mmHg on total hemoglobin concentration changes; and 0.963 r 2 , 1.688 mmHg 2 MSE, and 95% CI of [ - 2.450 2.397 ] mmHg on CBF changes. Conclusions: This study provides a proof of concept for the use of NIRS in noninvasive ICP estimation.

18.
PLoS One ; 17(9): e0274258, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36112634

RESUMO

Diffuse correlation spectroscopy (DCS) has been widely explored for its ability to measure cerebral blood flow (CBF), however, mostly under the assumption that the human head is homogenous. In addition to CBF, knowledge of extracerebral layers, such as skull thickness, can be informative and crucial for patient with brain complications such as traumatic brain injuries. To bridge the gap, this study explored the feasibility of simultaneously extracting skull thickness and flow in the cortex layer using DCS. We validated a two-layer analytical model that assumed the skull as top layer with a finite thickness and the brain cortex as bottom layer with semi-infinite geometry. The model fitted for thickness of the top layer and flow of the bottom layer, while assumed other parameters as constant. The accuracy of the two-layer model was tested against the conventional single-layer model using measurements from custom made two-layer phantoms mimicking skull and brain. We found that the fitted top layer thickness at each source detector (SD) distance is correlated with the expected thickness. For the fitted bottom layer flow, the two-layer model fits relatively consistent flow across all top layer thicknesses. In comparison, the conventional one-layer model increasingly underestimates the bottom layer flow as top layer thickness increases. The overall accuracy of estimating first layer thickness and flow depends on the SD distance in relationship to first layer thickness. Lastly, we quantified the influence of uncertainties in the optical properties of each layer. We found that uncertainties in the optical properties only mildly influence the fitted thickness and flow. In this work we demonstrate the feasibility of simultaneously extracting of layer thickness and flow using a two-layer DCS model. Findings from this work may introduce a robust and cost-effective approach towards simultaneous bedside assessment of skull thickness and cerebral blood flow.


Assuntos
Circulação Cerebrovascular , Cabeça , Encéfalo/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Análise Espectral/métodos
19.
Neurophotonics ; 9(Suppl 2): S24001, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36052058

RESUMO

This report is the second part of a comprehensive two-part series aimed at reviewing an extensive and diverse toolkit of novel methods to explore brain health and function. While the first report focused on neurophotonic tools mostly applicable to animal studies, here, we highlight optical spectroscopy and imaging methods relevant to noninvasive human brain studies. We outline current state-of-the-art technologies and software advances, explore the most recent impact of these technologies on neuroscience and clinical applications, identify the areas where innovation is needed, and provide an outlook for the future directions.

20.
Metabolites ; 12(7)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35888791

RESUMO

Near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) measure cerebral hemodynamics, which in turn can be used to assess the cerebral metabolic rate of oxygen (CMRO2) and cerebral autoregulation (CA). However, current mathematical models for CMRO2 estimation make assumptions that break down for cerebral perfusion pressure (CPP)-induced changes in CA. Here, we performed preclinical experiments with controlled changes in CPP while simultaneously measuring NIRS and DCS at rest. We observed changes in arterial oxygen saturation (~10%) and arterial blood volume (~50%) with CPP, two variables often assumed to be constant in CMRO2 estimations. Hence, we propose a general mathematical model that accounts for these variations when estimating CMRO2 and validate its use for CA monitoring on our experimental data. We observed significant changes in the various oxygenation parameters, including the coupling ratio (CMRO2/blood flow) between regions of autoregulation and dysregulation. Our work provides an appropriate model and preliminary experimental evidence for the use of NIRS- and DCS-based tissue oxygenation and metabolism metrics for non-invasive diagnosis of CA health in CPP-altering neuropathologies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA