1.
Heart Vessels ; 38(6): 839-848, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36692544

RESUMO

Cerebral tissue oximetry with near-infrared spectroscopy (NIRS) is used to monitor cerebral oxygenation during cardiac surgery. To date, reduced baseline cerebral NIRS values have been attributed to reduced cerebral blood flow primarily based on a significant positive correlation between left ventricular ejection fraction (LVEF) and baseline rSO2 measured with the INVOS 5100C oximeter. Reportedly, however, rSO2, but not StO2 measured with the FORESIGHT Elite oximeter, correlated with LVEF. We, thus, investigated associations among baseline NIRS values measured with three different oximeters before anesthesia for cardiac surgery and preoperative transthoracic echocardiography (TTE) variables, including LVEF, to examine whether there are inter-device differences in associations among baseline NIRS values and TTE variables. Using Spearman's correlation coefficient, we retrospectively investigated associations among 15 preoperative TTE variables, including LVEF, and baseline NIRS values, including rSO2, StO2, and TOI with the NIRO-200NX oximeter in 1346, 515, and 301 patients, respectively. Only rSO2 (p < 0.00001), but not TOI or StO2 (p > 0.05), positively correlated with LVEF. On the other hand, baseline rSO2, TOI, and StO2 consistently, negatively correlated with the left atrial diameter index (LADI), early diastolic transmitral flow velocity (E), E-to-early diastolic mitral annular velocity ratio (E/e'), estimated right ventricular systolic pressure (eRVP), and inferior vena cava diameter index (IVCDI) (p < 0.0005 to p < 0.00001). Because all of these five TTE variables could be positively associated with right as well as left ventricular filling pressure, our results indicated that reduced baseline NIRS values were consistently associated not with reduced LVEF but with TTE findings indicative of elevated biventricular filling pressure. Our data suggest that regional venous congestion greatly contributes to reduced baseline NIRS values in patients undergoing cardiac surgery.


Assuntos
Anestesia , Procedimentos Cirúrgicos Cardíacos , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Oximetria/métodos , Oxigênio , Ecocardiografia
2.
J Anesth ; 36(3): 374-382, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35247102

RESUMO

PURPOSE: This trial was conducted to compare effects of continuing versus withholding single-pill combination tablets consisting of angiotensin receptor blockers (ARBs) and calcium channel blockers (CCBs) on perioperative hemodynamics and clinical outcomes. METHODS: Patients undergoing minor abdominal or urological surgery (n = 106) were randomly assigned to Group C, in which ARB/CCB combination tablets were continued until surgery, or Group W, in which they were withheld within 24 h of surgery. Perioperative hemodynamics and clinical outcomes were compared between the Groups. RESULTS: The incidence of hypotension during anesthesia requiring repeated treatment with vasoconstrictors was higher in Group C than Group W (p = 0.0052). Blood pressure during anesthesia was generally lower in Group C than Group W (p < 0.05) despite significantly more doses of ephedrine and phenylephrine administrated in Group C (p = 0.0246 and p = 0.0327, respectively). The incidence of postoperative hypertension did not differ between Groups (p = 0.3793). Estimated glomerular filtration rate (eGFR) on the preoperative day did not differ between Groups (p = 0.7045), while eGFR was slightly lower in Group C than Group W on the first and third postoperative days (p = 0.0400 and p = 0.0088, respectively), although clinically relevant acute kidney injury did not develop. CONCLUSIONS: Continuing ARB/CCB combination tablets preoperatively in patients undergoing minor surgery increased the incidence of hypotension during anesthesia, increased requirements of vasoconstrictors to treat hypotension, and might deteriorate postoperative renal function, albeit slightly. These results suggest that withholding ARB/CCB tablets preoperatively is preferable to continuing them. CLINICAL TRIAL REGISTRATION: This trial is registered with the Japan Registry of Clinical Trials (jRCT) at Japanese Ministry of Health, Labour, and Welfare (Trial ID: jRCT1031190027).


Assuntos
Hipertensão , Hipotensão , Antagonistas de Receptores de Angiotensina/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina , Pressão Sanguínea , Bloqueadores dos Canais de Cálcio/efeitos adversos , Quimioterapia Combinada , Humanos , Hipotensão/induzido quimicamente , Hipotensão/epidemiologia , Procedimentos Cirúrgicos Menores , Período Perioperatório , Comprimidos/farmacologia , Comprimidos/uso terapêutico , Vasoconstritores/uso terapêutico
3.
J Artif Organs ; 24(4): 433-441, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33826034

RESUMO

Baseline cerebral regional saturation (rSO2) measured using the INVOS 5100C (Medtronic, MN, USA) varies widely among patients with cardiac and/or renal diseases. To identify significant correlates of baseline rSO2 and to investigate intraoperative rSO2 changes, we conducted a retrospective study in 494 patients undergoing on-pump cardiovascular surgery. Correlations between preoperative blood laboratory test variables and baseline rSO2 before anesthesia were examined. Intraoperative rSO2 changes were analyzed. Of all the variables examined, log-transformed B-type natriuretic peptide (BNP) most significantly and negatively correlated with baseline rSO2 (r = - 0.652, p < 0.0001). Intraoperatively, rSO2 showed the lowest value during cardiopulmonary bypass (CPB) (median rSO2: 56.2% during CPB vs. 63.9% at baseline, p < 0.0001). Although rSO2 during CPB correlated positively with hemoglobin concentration and oxygen delivery during CPB (r = 0.192, p < 0.0001; and r = 0.172, p = 0.0001, respectively), it correlated much more closely with baseline rSO2 (r = - 0.589, p < 0.0001). Thus, patients showing low baseline rSO2 primarily associated with preoperatively high BNP continued to show low rSO2 even during CPB independent of hemodynamics artificially controlled by CPB. Our findings suggest that low baseline rSO2 in patients with high BNP due to cardiac and/or renal diseases is more likely to result from tissue edema causing alterations in optical pathlength and thus in calculated rSO2 values, not readily modifiable with CPB, rather than actual cerebral hemodynamic alterations readily modifiable with CPB. These may partly explain why the INVOS oximeter is a trend monitor requiring baseline measures.


Assuntos
Ponte Cardiopulmonar , Oximetria , Encéfalo , Humanos , Oxigênio , Consumo de Oxigênio , Estudos Retrospectivos
4.
J Cardiothorac Vasc Anesth ; 32(1): 187-196, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28778770

RESUMO

OBJECTIVES: To investigate an association between the preoperative plasma B-type natriuretic peptide (BNP) concentration and cerebral regional saturation (rSO2) measured using the INVOS oximeter (Medtronic, Minneapolis, MN). DESIGN: A retrospective data analysis. SETTING: Single university hospital. PARTICIPANTS: Patients undergoing off-pump coronary artery bypass (OPCAB) surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Associations of variables obtained from preoperative blood laboratory tests and transthoracic echocardiography with baseline rSO2 before induction of general anesthesia were investigated using bivariate and multivariate regression analyses in 330 OPCAB patients. With bivariate analyses, age; body size-related variables such as weight and body surface area; hematologic function-related variables such as blood hemoglobin (Hb) concentration and arterial oxygen saturation; renal function-related variables including estimated glomerular filtration rate, creatinine, and blood urea nitrogen; hepatic function-related variables including cholinesterase, albumin, total bilirubin, and alanine aminotransferase; serum electrolytes including sodium, chloride, and phosphorus; BNP or log-transformed BNP; and 13 transthoracic echocardiography variables such as left ventricular ejection fraction highly significantly correlated with baseline rSO2 (p < 0.0001). However, the multiple regression analysis revealed that only BNP and Hb remained major factors significantly associated with baseline rSO2 (p < 0.0001), while estimated glomerular filtration rate, arterial oxygen saturation, and body surface area remained minor factors (p < 0.05). Baseline rSO2 correlated better with log-transformed BNP than with BNP, indicating that rSO2 correlated with BNP in an exponential fashion. CONCLUSIONS: Preoperative BNP and Hb concentrations were 2 major factors associated with INVOS rSO2 in patients undergoing OPCAB.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Hemoglobinas/metabolismo , Peptídeo Natriurético Encefálico/sangue , Oximetria/métodos , Consumo de Oxigênio/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oximetria/instrumentação , Estudos Retrospectivos , Espectroscopia de Luz Próxima ao Infravermelho/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA