Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Heart Rhythm ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38797310

RESUMO

BACKGROUND: Peridevice leak (PDL) following left atrial appendage closure (LAAC) portends adverse outcomes. OBJECTIVE: To assess the incidence, predictors, clinical implications, and temporal evolution of PDL following LAAC. METHODS: This single-center retrospective study included all patients who underwent LAAC with Watchman FLX and had no PDL detected at implant. The primary endpoint was incidence of new PDL at initial imaging. The composite secondary endpoint included continued oral anticoagulation after initial imaging, device-related thrombus, stroke or transient ischemic attack, major bleeding, and need for PDL closure at longest follow-up. Temporal evolution of PDL was assessed in patients with available surveillance imaging. RESULTS: Among 355 patients who completed imaging at 47 (IQR 6) days, 139 (39%) had a new PDL with a mean leak size of 3.2±1.4 [median 3.0 (IQR 2.0), and range 1.0-9.0 mm]. Multiple deployment attempts and larger device size were positive predictors of PDL, while increased contrast volume administration was a negative predictor of PDL. The composite secondary endpoint occurred in 42 (30%) and 33 (15%) patients with and without PDL respectively (p<0.001). Among the 139 patients with PDL, 43 (31%) had surveillance imaging where leak size regressed from 3.7±1.8mm at 46 (IQR 7) days to 1.7±2.0mm at 189 (IQR 127) days (p<0.001). The leak size regressed in 33 (77%), remained stable in 4 (9%), and progressed in 6 (14%) cases. CONCLUSION: Despite design improvements, LAAC with Watchman FLX demonstrates significant incidence of PDL with meaningful clinical implications. Regardless of initial size, most leaks regressed over time.

4.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493499

RESUMO

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiopatias , Acidente Vascular Cerebral , Trombose , Humanos , Estudos Retrospectivos , Cardioversão Elétrica/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/prevenção & controle , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Cateterismo Cardíaco/efeitos adversos
5.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1719-1729, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227359

RESUMO

BACKGROUND: Multiple cardiac sarcoidosis (CS) diagnostic schemes have been published. OBJECTIVES: This study aims to evaluate the association of different CS diagnostic schemes with adverse outcomes. The diagnostic schemes evaluated were 1993, 2006, and 2017 Japanese criteria and the 2014 Heart Rhythm Society criteria. METHODS: Data were collected from the Cardiac Sarcoidosis Consortium, an international registry of CS patients. Outcome events were any of the following: all-cause mortality, left ventricular assist device placement, heart transplantation, and appropriate implantable cardioverter-defibrillator therapy. Logistic regression analysis evaluated the association of outcomes with each CS diagnostic scheme. RESULTS: A total of 587 subjects met the following criteria: 1993 Japanese (n = 310, 52.8%), 2006 Japanese (n = 312, 53.2%), 2014 Heart Rhythm Society (n = 480, 81.8%), and 2017 Japanese (n = 112, 19.1%). Patients who met the 1993 criteria were more likely to experience an event than patients who did not (n = 109 of 310, 35.2% vs n = 59 of 277, 21.3%; OR: 2.00; 95% CI: 1.38-2.90; P < 0.001). Similarly, patients who met the 2006 criteria were more likely to have an event than patients who did not (n = 116 of 312, 37.2% vs n = 52 of 275, 18.9%; OR: 2.54; 95% CI: 1.74-3.71; P < 0.001). There was no statistically significant association between the occurrence of an event and whether a patient met the 2014 or the 2017 criteria (OR: 1.39; 95% CI: 0.85-2.27; P = 0.18 or OR: 1.51; 95% CI: 0.97-2.33; P = 0.067, respectively). CONCLUSIONS: CS patients who met the 1993 and the 2006 criteria had higher odds of adverse clinical outcomes. Future research is needed to prospectively evaluate existing diagnostic schemes and develop new risk models for this complex disease.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Transplante de Coração , Miocardite , Sarcoidose , Humanos , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia , Sarcoidose/complicações , Desfibriladores Implantáveis/efeitos adversos
6.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221927

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Ecocardiografia Transesofagiana/métodos , Imageamento por Ressonância Magnética , Trombose/diagnóstico por imagem , Cateterismo Cardíaco , Resultado do Tratamento
7.
JACC Clin Electrophysiol ; 8(6): 795-799, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35738857

RESUMO

Thirty-eight patients had assessment of pulmonary vein occlusion with the dielectric mapping system and injection of saline as an alternative to contrast. Contrast injection was required to ascertain pulmonary vein occlusion in 31.6% (12 of 38) of subjects and 17.4% (27 of 155) of veins. No contrast was required in the last 13 subjects. In this single center study, a novel mapping-guided cryoablation approach appeared to minimize the use of contrast in pulmonary vein isolation for the treatment of atrial fibrillation.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Pneumopatia Veno-Oclusiva , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Estudos de Viabilidade , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Pneumopatia Veno-Oclusiva/cirurgia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34554620

RESUMO

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Assuntos
Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas , Cardioversão Elétrica , Impedância Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Ohio , Tela Subcutânea
11.
J Cardiovasc Electrophysiol ; 32(4): 1166-1170, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33625775

RESUMO

The standard technique for accessory pathway ablation involves mapping along the mitral and tricuspid annulus to localize the regions of earliest ventricular activation during antegrade pathway conduction, earliest atrial activation during retrograde conduction or detection of an accessory pathway potential. In some cases despite what appears to be appropriate mapping, catheter positioning and adequate power delivery the ablation is not successful. In many of these cases, the pathway is felt to be inaccessible because of a location remote from the mitral or tricuspid annulus that cannot be affected by endocardial power delivery along the annulus. In the case of difficult left sided pathways, some may be reached and ablated via the coronary sinus or its branches. Right sided pathways cannot be approached in this fashion since there is no venous structure analogous to the coronary sinus around the tricuspid annulus. Alternative mapping and ablation techniques for these difficult pathways have included epicardial mapping via direct pericardial access or attempts to localize pathway insertion areas remote from the valve annulus which may be amenable to endocardial ablation. We describe the use of post-pacing interval mapping to localize the atrial input of a right sided antegrade only accessory pathway that was resistant to conventional mapping and ablation strategies.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Fascículo Atrioventricular , Eletrocardiografia , Endocárdio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos
12.
JACC Clin Electrophysiol ; 7(6): 745-754, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33516715

RESUMO

OBJECTIVES: This study reports resource use and economic implications of rhythm monitoring with subcutaneous cardiac rhythm monitors (SCRMs). BACKGROUND: SCRMs generate a substantial amount of data that requires timely adjudication for appropriate clinical care. Resource use for SCRM monitoring is not known. METHODS: The study included consecutive transmissions during 4 weeks from 1,811 SCRMs. Resource use was quantified by assessment of time commitment of device clinic personnel and electrophysiologists for data adjudication. Incidence and characteristics of false positive (FP) episodes were assessed. Impact of custom programming for arrhythmia detection on incidence of FP episodes and resource use was analyzed. RESULTS: A total of 1,457 transmissions (alerts = 462; full downloads = 995) were received during study period. Average device clinic personnel time for adjudication of 1 transmission was 15 ± 6 min. This totaled to 364 h spent (2.3 full-time staff) over the 4-week period, which translated into a salary cost of $12,000 U.S. dollars (USD). Average time spent by an electrophysiologist for 1 transmission was 1.5 ± 1 min and totaled to 37 h for 4 weeks, which translated into an estimated cost of $9,600 USD. Of 1,457 total transmissions, 512 (35%) represented multiple transmissions from the same patients, which resulted in no additional reimbursement. Incidence of FP episodes in the entire cohort was 50% and was variable in alert (60%) and full download (49%) (p = 0.04) transmissions. When SCRMs with manufacturer suggested nominal programming and institutional custom programming were compared, there was a reduction in FP episodes (55% vs. 16%; p = 0.01), which translated to a 34% reduction in resource use for data adjudication. CONCLUSIONS: SCRM data adjudication requires significant resources. Custom programming for SCRMs may overcome the data deluge.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Humanos , Incidência , Monitorização Fisiológica
13.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33205561

RESUMO

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Assuntos
Cardiomiopatias , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/epidemiologia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
15.
J Atr Fibrillation ; 12(6): 2242, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33024484

RESUMO

BACKGROUND: Catheter ablation (CA) is an established treatment for patients with symptomatic atrial fibrillation (AF). The purpose of this study was to evaluate the safety and efficacy of single CA in AF patients with extreme obesity (body mass index [BMI] ≥ 40 kg/m2) and its long-term impact on body weight. METHODS: Patients with BMI ≥40 kg/m2 who underwent CA at the Ohio State University between 2012 and 2016 were included. The primary efficacy endpoint was no atrial arrhythmia lasting > 30 seconds without anti-arrhythmic drugs during 1-year follow-up after a single procedure. RESULTS: Out of 230 AF patients with BMI ≥ 40 kg/m2 undergoing CA, pulmonary vein isolation was achieved in 226 (98%) patients.Seventeen patients (7.4%) experienced acute major complications, including pericardial effusion, vascular complications and respiratory failure. Patient characteristics for 135 patients with complete 1-year follow-up were as follows: mean age 58.6 ± 9.6 years, mean BMI 44.5±4.7 kg/m2, female 63 (47%), non-paroxysmal AF 100 (74%), median CHA2DS2-VASc score 2 (IQR:1-3). In this cohort, the primary efficacy endpoint was achieved in 44 (33%) patients. Paroxysmal AF was associated with higher CA success compared to non-paroxysmal (51 vs. 26% [p < 0.01]).There was no significant weight change even in patients with successful AF CA. CONCLUSIONS: Extreme obesity is associated with low AF CA success, particularly in those with non-paroxysmal AF. Successful AF CA was not associated with long-term weight reduction. A better treatment strategy is needed in this population of AF and extreme obesity.

18.
Heart Rhythm ; 17(1): 75-80, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31323348

RESUMO

BACKGROUND: Implantable loop recorder (ILR) is preferred strategy for prolonged rhythm monitoring. OBJECTIVE: The purpose of this study was to report the incidence and causes of false-positive (FP) diagnoses during remote monitoring with ILR. METHODS: During a 4-week study period, all consecutive remote transmissions in patients with ILR (Reveal LINQ, Medtronic) implanted for atrial fibrillation (AF) surveillance, cryptogenic stroke (CS), and syncope were reviewed. A nurse specializing in device management and an electrophysiologist adjudicated all transmissions. Primary endpoint of the study was incidence of FP in patients with AF, CS, and syncope. RESULTS: A total of 695 remote transmissions (scheduled downloads: 414; Alerts: 281) sent from 559 patients were adjudicated. The majority of patients had ILR for AF surveillance (n = 321), followed by CS (n =168) and syncope (n = 70) with nominal programming for rhythm diagnosis. Incidence of FP transmissions during the study period was 46%, 86%, and 71% in patients with AF, CS, and syncope, respectively. Incidence of FP transmissions was higher in patients with CS and syncope than in patients with AF (P <.001). For scheduled transmissions, primary causes of FP were signal dropout and undersensing; for alert transmissions, primary reasons for FP were premature atrial and ventricular ectopy. CONCLUSION: Incidence of FP during remote monitoring with nominal settings on this ILR was substantial, ranging from 46% to 86% depending on the indication for implantation. Adjudication of these transmissions required a considerable time commitment from electrophysiologists and device clinic personnel but would be required to avoid misdiagnosis and potential errors in clinical management.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos Implantados/efeitos adversos , Monitorização Fisiológica/métodos , Idoso , Fibrilação Atrial/diagnóstico , Falha de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico
19.
J Interv Card Electrophysiol ; 57(2): 311-318, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31813098

RESUMO

PURPOSE: To assess the feasibility and safety of same-day discharge after S-ICD implantation by implementing a specific analgesia protocol and phone follow-up. METHODS: Consecutive patients presenting for outpatient S-ICD implantation were enrolled between 1/1/2018 and 4/30/2019. An analgesia protocol included pre-operative acetaminophen and oxycodone, intraoperative local bupivacaine, and limited use of oxycodone-acetaminophen at discharge. The primary outcome was successful same-day discharge. Numerical Pain Rating Scale (NPRS) on postoperative day (POD) 1, 3, 14, and 30 and any unplanned health care visits during the 1-month follow-up period were assessed. RESULTS: Out of 53 potentially eligible S-ICD patients, 49 patients (92.5%) were enrolled and successfully discharged on the same day. Mean age of these 49 patients was 47 ± 14 years. There were no acute procedural complications. Severe pain (NPRS ≥ 8) on POD 0, 1, and 3 was present in 14.3%, 14.3%, and 8.2% of patients, respectively. The total in-hospital stay was 534 ± 80 min. Four unplanned visits (8%) due to cardiac or device-related issues occurred during 1-month follow-up, including 2 patients with heart failure exacerbation, one patient with an incisional infection, and one patient with inappropriate shocks. CONCLUSIONS: With the appropriate institutional protocol including specific analgesics and phone follow-up, same-day discharge after outpatient S-ICD implantation is feasible and appears safe for most patients.. Device-related pain can be severe in the first 3 days post-implantation and can be successfully treated with limited supply of narcotic medications.


Assuntos
Analgesia/métodos , Desfibriladores Implantáveis , Segurança do Paciente , Implantação de Prótese/métodos , Idoso , Continuidade da Assistência ao Paciente , Estudos de Viabilidade , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Medição da Dor
20.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA