1.
Environ Sci Pollut Res Int ; 31(8): 12340-12350, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38231331

RESUMO

In the departments of civil engineering, many experiments are conducted in laboratories for educational and research purposes. Varying degrees of respirable dust are generated as the outcome of these experiments, which could cause harm to instructors' and students' health. This study is devised to highlight the importance of indoor air quality in university laboratories. As part of the research, four different particulate matter (PM) sizes (PM1.0, PM2.5, PM4.0, and PM10) were measured during specific experiments-sieve analysis, preparation of the concrete mixture, crushing aggregate by jaw crusher, dynamic triaxial compression test, sieve analysis of silt specimen, cleaning sieve by an air compressor, and proctor compaction test-being conducted periodically in the laboratories of civil engineering departments. The measured values are mainly high compared to indoor air quality standards. Mitigation strategies were applied to reduce indoor air PM levels in the three experiments that contained the highest PM levels. The results have shown that mitigation strategies applied as control measures could make a remarkable difference in protecting instructors and civil engineering students.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Humanos , Material Particulado/análise , Poluentes Atmosféricos/análise , Laboratórios , Monitoramento Ambiental/métodos , Poeira/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Poluição do Ar em Ambientes Fechados/análise , Tamanho da Partícula
2.
Environ Sci Pollut Res Int ; 31(6): 9857-9866, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38198092

RESUMO

Asbestos has been used extensively in the construction industry for its superior insulation properties before its health hazards were discovered and its use eventually banned. It is likely that many residential buildings built before the 2000s in Turkey contain asbestos. Therefore, it is important to raise awareness of the potential danger of asbestos exposure during demolition work and to identify asbestos-containing materials and ensure their safe removal and disposal. This study is executed to determine the residential dwellings containing asbestos in Izmir, Turkey. The research included field studies to determine asbestos presence in the buildings that were damaged during the 2020 earthquake. Air measurements and bulk samples were taken from 50 buildings that would go through the demolition process. Eleven buildings were found to contain asbestos which corresponds to 22%. The detected asbestos type was 60% chrysotile (white asbestos). Results could be helpful for future demolition work, which are conducted in the same region that includes buildings with similar properties. Also, it is expected that the database created for this study could be useful in other studies in Turkey, where accurate statistical data related with asbestos measurements is essentially non-existent.


Assuntos
Amianto , Indústria da Construção , Turquia , Materiais de Construção , Amianto/análise , Asbestos Serpentinas