Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 230
Filtrar
1.
Arab J Urol ; 22(3): 131-137, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818253

RESUMO

Objectives: To compare lithotripsy ablation rate with the Moses modes versus conventional pulse modes when using the Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser. Methods: The Lumenis® Pulse P120H Holmium Laser System and a 365 µm Moses D/F/L fiber were used to assess stone ablation rate in conventional Short and Long Pulse as well as Moses Contact and Distance at 10 W (0.5Jx20Hz and 2Jx5Hz) and 60 W (1Jx60Hz and 2Jx30Hz). Hard and soft phantom stones were formed, and all tests were conducted in a custom experimental configuration installed in a saline-filled bath. The laser was delivered up to 3 kJ of total energy. The fragmentation pattern was assessed via photographs in each cohort. Results: The time to reach the target energy was 5 min and 50 s in all 10 W and 60 W trials, respectively. In both stone types, ablation was more effective when high-power, high-energy and Moses Distance was utilized. In soft stones, the lowest ablation rate was detected in the Long Pulse modality in all power, energy and frequency settings. Overall, when dusting settings (high-frequency, low-energy) were used, a deeper single cavitation was observed rather than small cavitations. Conclusions: The most effective pulse modality as evaluated via stone ablation rate depends on the stone hardness as well as energy and frequency settings. In both hard and soft stones, ablation is more effective when 60 W (2Jx30Hz) power settings and Moses Distance are used. Tailored laser settings in terms of energy and frequency could be set for each case scenario.

2.
Arab J Urol ; 22(3): 145-151, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818258

RESUMO

Objective: To evaluate the efficacy and safety of Holmium: Yttrium-Aluminum-Garnet (Ho:YAG) laser in bladder lithotripsy using high-power settings > 100 W. Materials and Methods: A combined experimental and clinical study was conducted. The Quanta Cyber: Ho 150 with a 550 µm Quanta optical fiber was utilized in all set-ups. Ablation rates for soft and hard artificial stones were tested in vitro using 100 W and 20 W power settings. In the experiment, a porcine bladder was used. The optical fiber was inserted through a rigid cystoscope, whilst a K-type thermocouple was inserted in the bladder dome. The tested high-power settings were 152 W, 120 W and 105 W. In every trial, the lasing time was over 60 s. In the clinical study, 35 patients underwent transurethral high-power bladder lithotripsy. Laser settings were set between 100 W and 150 W. Results: Stone mass (stone weight) was significantly lower after stone ablation independently of the stone type or the laser settings. Significantly higher mass decrease and ablation rate were detected in high-power compared to low-power settings. In the experiment, the highest temperature recorded was 32°C at 152 W. At 120 W and 105 W, the peak temperatures didn't reach 30°C. In the clinical study, a stone-free rate of 100% and a mean operative time of 43 ± 18 min were reported. All patients stayed in the hospital for one day except for one who presented minor hematuria. Additional complications did not occur. Conclusion: Ho:YAG laser lithotripsy > 100 W is an effective, fast and safe modality for the treatment of bladder calculi.

3.
J Endourol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38753723

RESUMO

Robot-assisted surgery (RAS) has been integrated into clinical practice to overcome several limitations of conventional open or laparoscopic surgery. After the expiration of the long key patent period of Intuitive Surgical, various robotic systems (RSs) have been developed aiming at improving certain characteristics of the first robotic platform, the Da Vinci RS. This narrative review provides an overview of the current RSs used in urology along with the initial results from their application in urologic procedures. Nine robotic platforms are being analyzed regarding their unique characteristics as well as their efficacy, safety, feasibility, and outcomes in urologic, oncological, or non-oncological operations. The main barrier to the wide application of RAS has been the increased cost that refers to both acquisition and maintenance costs. Besides, the health inequality resulting from the lack of expert robotic surgeons and the difficulty of performing robot-assisted procedures in provincial hospitals should be overcome. However, large properly designed comparative studies are required to establish the role of newly introduced RSs. In addition, urologists should keep abreast of new developments and research in robot-assisted urologic procedures.

4.
Minerva Urol Nephrol ; 76(2): 157-165, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38742551

RESUMO

INTRODUCTION: One recent addition to different lasers used for endoscopic enucleation of the prostate is the thulium fiber laser (TFL). The purpose of this systematic review is to present the feasibility, safety and efficacy of TFL Enucleation of the Prostate (ThuFLEP). EVIDENCE ACQUISITION: PubMed®, Scopus® and Cochrane® primary databases were systematically screened. The search strategy used the PICO (Patients, Intervention, Comparison, Outcome) criteria. Patients should be adults with benign prostatic obstruction (BPO) undergoing ThuFLEP. While comparative studies reporting comparison of ThuFLEP to other BPO treatments were included, cohort studies with no comparison group were also accepted. Outcomes including enucleation time and complication rates were reported. EVIDENCE SYNTHESIS: Twelve studies met all the predefined criteria and were included in the final qualitative synthesis. Mean operative time and enucleation time ranged from 46.6±10.2 to 104.5±33.6 and from 38.8±17.9 to 66.0±24.9 minutes, respectively. Most of the complications were Grade I or Grade II ones. Although TFL was found to present some advantages over older BPO treatments, its outcomes were comparable with other endoscopic enucleation approaches. CONCLUSIONS: ThuFLEP seems to be a feasible, safe and efficient approach for BPO symptoms management. Limited evidence showed that although ThuFLEP was associated with a reduced total operative time, it was also associated with worse IPSS improvement at 1-year follow-up, when compared with MOSESTM Holmium Laser Enucleation of the Prostate (HoLEP). These findings confirm the well-established opinion that the enucleation technique itself is more important than the technology which is used.


Assuntos
Terapia a Laser , Hiperplasia Prostática , Túlio , Humanos , Masculino , Hiperplasia Prostática/cirurgia , Túlio/uso terapêutico , Terapia a Laser/métodos , Terapia a Laser/instrumentação , Terapia a Laser/efeitos adversos , Resultado do Tratamento , Prostatectomia/métodos , Prostatectomia/efeitos adversos , Lasers de Estado Sólido/uso terapêutico , Duração da Cirurgia
5.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
6.
Cancers (Basel) ; 16(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38672537

RESUMO

The Mayo Adhesive Probability (MAP) score is a radiographic scoring system that predicts the presence of adherent perinephric fat (APF) during partial nephrectomies (PNs). The purpose of this systematic review is to summarize the current literature on the application of the MAP score for predicting intraoperative difficulties related to APF and complications in laparoscopic PNs. Three databases, PubMed, Scopus and Cochrane, were screened, from inception to 29 October 2023, taking into consideration the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Guidelines. All the inclusion criteria were met by eight studies. The total operative time was around two hours in most studies, while the warm ischemia time was <30 min in all studies and <20 min in four studies. Positive surgical margins, conversion and transfusion rates ranged from 0% to 6.3%, from 0% to 5.0% and from 0.7% to 7.5%, respectively. Finally, the majority of the complications were classified as Grade I-II, according to the Clavien-Dindo Classification System. The MAP score is a useful tool for predicting not only the presence of APF during laparoscopic PNs but also various intraoperative and postoperative characteristics. It was found to be significantly associated with an increased operative time, estimated blood loss and intraoperative and postoperative complication rates.

7.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
8.
Arch Ital Urol Androl ; 96(1): 12228, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363229

RESUMO

PURPOSE: The aim of the present, retrospective study was to describe our initial experience and early outcomes of Thulium Fiber Laser enucleation of the prostate (ThuFLEP) with the use of the FiberDust™ (Quanta System, Samarate, Italy) in patients with benign prostate hyperplasia. METHODS: From June 2022 to April 2023, all patients who underwent endoscopic enucleation of the prostate at Urology Department of the University Hospital of Patras were included. A single surgeon utilizing the same standardized operative technique performed all the surgeries. The primary endpoints included the uneventful completion of the operation, the surgical time and any minor or major complication observed intra- or post-operatively. RESULTS: Twenty patients with benign prostate hyperplasia were treated with ThuFLEP. All the surgeries were completed successfully and uneventfully. The enucleation phase of the operation was completed in a mean time of 45±9.1 min, while the average time needed for the morcellation was 17.65±3.42 min. No significant complications were observed intra- or post-operatively. The average hemoglobin drop was calculated to be 0.94±0.71 g/dL. CONCLUSIONS: All the operations were successfully and efficiently completed with the use of the FiberDust™ (Quanta System, Samarate, Italy) in ThuFLEP. Significant blood loss or major complications were not observed.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Próstata/cirurgia , Estudos Retrospectivos , Túlio , Hiperplasia , Resultado do Tratamento , Lasers de Estado Sólido/uso terapêutico , Hiperplasia Prostática/cirurgia , Ressecção Transuretral da Próstata/métodos
9.
Arch Ital Urol Androl ; 96(1): 12248, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38389459

RESUMO

PURPOSE: The aim of this study is the evaluation of the distribution of paclitaxel (PTX) released by a coated balloon in the layers of rabbit's urethra. METHODS: 18 rabbits were included. A laser device was used for the stricture formation. After two weeks, dilation of the strictured urethra was performed by using Advance 35LP PTA balloons and Advance 18 PTX PTA balloons. The experimental models were divided into 3 groups. The group Α included two rabbits without any intervention except for the stenosis procedure. Group B compromised six rabbits that underwent dilation with Advance 35LP PTA balloons. Group C consisted of 10 rabbits to which dilation with both Advance 35LP PTA balloons and Advance 18 PTX PTA balloons was applied. Histological evaluation and Immunohistochemistry were performed on all specimens. RESULTS: Inflammation, fibrosis and ruptures were detected in the specimens of the study. In specimens of Group C the decrease of inflammation and fibrosis rate was greater. Anti-PTX antibody was detected in the epithelium, lamina propria and smooth muscle layer of all specimens of urethras that have been harvested immediately and 1 day after the dilation with Advance 18 PTX PTA balloon and it was not observed in any layer of the urethral wall of the rest of the examined specimens of Group C. CONCLUSIONS: PTX's enrichment was detected in the smooth muscle layer of all specimens that have been harvested immediately and 24h after the dilation with Advance 18 PTX PTA balloons. PTX may play an inhibitive role in the recurrence of the stenosis.


Assuntos
Estreitamento Uretral , Animais , Coelhos , Estreitamento Uretral/terapia , Paclitaxel , Uretra , Constrição Patológica , Fibrose , Inflamação
10.
Asian J Urol ; 11(1): 110-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312817

RESUMO

Objective: To evaluate the feasibility and the safety of medial non-papillary percutaneous nephrolithotomy (npPCNL) for the management of large proximal ureteral stones. Methods: We evaluated prospectively collected data of 37 patients with large proximal ureteral stones more than 1.5 cm in diameter treated by prone npPCNL. Depending on stone size, in-toto stone removal or lithotripsy using the Lithoclast® Trilogy (EMS Medical, Nyon, Switzerland) was performed. Perioperative parameters including operative time (from start of puncture to the skin suturing), stone extraction time (from the first insertion of the nephroscope to the extraction of all stone fragments), and the stone-free rate were evaluated. Results: Twenty-one males and 16 females underwent npPCNL for the management of large upper ureteral calculi. The median age and stone size of treated patients were 58 (interquartile range [IQR]: 51-69) years and 19.3 (IQR: 18.0-22.0) mm, respectively. The median operative time and stone extraction time were 25 (IQR: 21-29) min and 8 (IQR: 7-10) min, respectively. One case (2.7%) of postoperative bleeding and two cases (5.4%) of prolonged fever were managed conservatively. The stone-free rate at a 1-month follow-up was 94.6%. Conclusion: The npPCNL provides a straight route to the ureteropelvic junction and proximal ureter. Approaching from a dilated portion of the ureter under low irrigation pressure with larger diameter instruments results in effective and safe stone extraction within a few minutes.

11.
Asian J Urol ; 11(1): 1-9, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38312823

RESUMO

Objective: Transurethral resection of bladder tumor is one of the most common everyday urological procedures. This kind of surgery demands a set of skills that need training and experience. In this review, we aimed to investigate the current literature to find out if simulators, phantoms, and other training models could be used as a tool for teaching urologists. Methods: A systematic review was performed according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses statement and the recommendations of the European Association of Urology guidelines for conducting systematic reviews. Fifteen out of 932 studies met our inclusion criteria and are presented in the current review. Results: The UroTrainer (Karl Storz GmbH, Tuttlingen, Germany), a virtual reality training simulator, achieved positive feedback and an excellent face and construct validity by the participants. The inspection of bladder mucosa, blood loss, tumor resection, and procedural time was improved after the training, especially for inexperienced urologists and medical students. The construct validity of UroSim® (VirtaMed, Zurich, Switzerland) was established. SIMBLA simulator (Samed GmbH, Dresden, Germany) was found to be a realistic and useful tool by experts and urologists with intermediate experience. The test objective competency model based on SIMBLA simulator could be used for evaluating urologists. The porcine model of the Asian Urological Surgery Training and Education Group also received positive feedback by the participants that tried it. The Simulation and Technology Enhanced Learning Initiative Project had an extraordinary face and content validity, and 60% of participants would like to use the simulators in the future. The 5-day multimodal training curriculum "Boot Camp" in the United Kingdom achieved an increase of the level of confidence of the participants that lasted months after the project. Conclusion: Simulators and courses or curricula based on a simulator training could be a valuable learning tool for any surgeon, and there is no doubt that they should be a part of every urologist's technical education.

13.
Urol Ann ; 16(1): 43-51, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38415239

RESUMO

Objective: In this review, we investigated the current literature to find out which artificial stones (AS) are available in endourology, and in which experimental and training schemes they are used. Materials and Methods: A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Twenty-one out of 346 studies met our inclusion criteria and are presented in the current review. The inclusion criteria were the existence of AS and their use for laboratory and training studies. Results: There is a wide variety of materials used for the creation of AS. BegoStone powder (BEGO USA, Lincoln, Rhode Island) and plaster of Paris™ were used in most of the studies. In addition, Ultracal-30 (U. S. Gypsum, Chicago, IL) was also used. Other materials that were used as phantoms were AS created from plaster (Limbs and Things, UK), standardized artificial polygonal stone material (Chaton 1028, PP13, Jet 280; Swarovski), model stones consisting of spheres of activated aluminum (BASF SE, Ludwigshafen am Rhein, Deutschland), Orthoprint (Zhermack, Badia Polesine, Italy), and a combination of plaster of Paris, Portland cement, and Velmix (calcium sulfate powder). Many experimental settings have been conducted with the use of AS. Our research demonstrated nine studies regarding testing and comparison of holmium: yttrium-aluminum-garnet laser devices, techniques, and settings. Six studies were about extracorporeal shock wave lithotripsy testing and settings. Three experiments looked into treatment with percutaneous nephrolithotomy. Additionally, one study each investigated imaging perioperatively for endourological interventions, stone bacterial burden, and obstructive uropathy. Conclusion: AS have been used in a plethora of laboratory experimental studies. Independent of their similarity to real urinary tract stones, they present a tremendous potential for testing and training for endourological interventions.

14.
World J Urol ; 42(1): 79, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353743

RESUMO

PURPOSE: To identify laser settings and limits applied by experts during laser vaporization (vapBT) and laser en-bloc resection of bladder tumors (ERBT) and to identify preventive measures to reduce complications. METHODS: After a focused literature search to identify relevant questions, we conducted a survey (57 questions) which was sent to laser experts. The expert selection was based on clinical experience and scientific contribution. Participants were asked for used laser types, typical laser settings during specific scenarios, and preventive measures applied during surgery. Settings for a maximum of 2 different lasers for each scenario were possible. Responses and settings were compared among the reported laser types. RESULTS: Twenty-three of 29 (79.3%) invited experts completed the survey. Thulium fiber laser (TFL) is the most common laser (57%), followed by Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) (48%), continuous wave (cw) Thulium:Yttrium-Aluminium-Garnet (Tm:YAG) (26%), and pulsed Tm:YAG (13%). Experts prefer ERBT (91.3%) to vapBT (8.7%); however, relevant limitations such as tumor size, number, and anatomical tumor location exist. Laser settings were generally comparable; however, we could find significant differences between the laser sources for lateral wall ERBT (p = 0.028) and standard ERBT (p = 0.033), with cwTm:YAG and pulsed Tm:YAG being operated in higher power modes when compared to TFL and Ho:YAG. Experts prefer long pulse modes for Ho:YAG and short pulse modes for TFL lasers. CONCLUSION: TFL seems to have replaced Ho:YAG and Tm:YAG. Most laser settings do not differ significantly among laser sources. For experts, continuous flow irrigation is the most commonly applied measure to reduce complications.


Assuntos
Alumínio , Túlio , Neoplasias da Bexiga Urinária , Ítrio , Humanos , Túlio/uso terapêutico , Neoplasias da Bexiga Urinária/cirurgia , Lasers , Tecnologia
15.
Int Urol Nephrol ; 56(5): 1577-1583, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38175386

RESUMO

PURPOSE: To investigate the learning curve in four basic surgical skills in laparoscopic and robotic surgeries, and evaluate the approximate time needed to reach sufficient expertise in performing these tasks with the avatera® system. METHODS: Twenty urology residents with no previous experience in dry-lab and robotic surgery were asked to complete four basic laparoscopic tasks (peg transfer, circle cutting, needle guidance, and suturing) laparoscopically and robotically. All participants were asked to complete the tasks first after watching the Uroweb educational material and, second, after undertaking a 2-hour training in robotic and laparoscopic dry-lab. Thereafter, all trainees continued to undertake 2-hour training programs until being able to complete the tasks with the avatera® robot at the desired time. Paired t test and one-way ANOVA test were used to analyze time differences between the groups. RESULTS: Time needed to complete all tasks either robotically or laparoscopically was significantly less in the second compared to the first attempt for all Groups in each Task. In the robotic dry-lab, time needed to complete the tasks was significantly less than in the laparoscopic dry-lab. A significant effect of previous laparoscopic experience of the participants on the training time needed to achieve most of the goal times was detected. CONCLUSION: The results of the study highlight the role of previous laparoscopic experience in the training time needed to achieve the performance time goals and demonstrate that the learning curve of basic surgical skills using the avatera® system is steeper than the laparoscopic one.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Competência Clínica , Robótica/educação , Laparoscopia/métodos , Curva de Aprendizado
16.
J Laparoendosc Adv Surg Tech A ; 34(3): 239-245, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38252556

RESUMO

Purpose: To evaluate the utilization of novel Avatera system in urological operations according to the IDEAL-D framework recommendations for high-risk invasive surgical devices. Materials and Methods: Three surgeons attempted to perform 23 upper and lower urinary tract operations on human cadavers and in live porcine models using the Avatera system. Total operative time and the duration of the substeps were evaluated. Surgical performance was assessed with the Global Evaluative Assessment of Robotic Skills (GEARS) score. Suturing was rated using the technical checklist for the assessment of suturing in robotic surgery. Attending surgeons rated their satisfaction with the Avatera system on a scale of 1-5. Results and Limitation: Seventeen out of 18 operations performed on cadavers were completed, while one pyeloplasty was discontinued. All five operations performed in porcine models were completed. Although 1 pig was euthanized on the fifth postoperative day, its symptoms were unrelated to surgery. Mean GEARS and Suturing scores in the upper urinary tract were 29 ± 0.7 and 29.5 ± 0.95, respectively, and in the lower urinary 28.5 ± 1.2 and 29.5 ± 0.5, respectively. Surgeons' satisfaction was high or very high for all procedures. Conclusions: The Avatera system was associated with good surgical performance and high surgeons' satisfaction rates. All urological procedures performed were shown to be feasible, with comparable risks to other robot-assisted surgery systems.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Animais , Suínos , Próstata/cirurgia , Bexiga Urinária , Prostatectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Cadáver , Competência Clínica
17.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217743

RESUMO

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Assuntos
Alumínio , Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Ítrio , Humanos , Túlio , Urolitíase/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tecnologia , Hólmio
18.
J Clin Med ; 13(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38276127

RESUMO

Endoscopic combined intrarenal surgery (ECIRS) provides simultaneous retrograde and percutaneous access to the upper urinary tract. The purpose of this study is to present revised data, tips and tricks, and technique modifications arising from our five-year experience with ECIRS. The data of 62 patients who underwent nonpapillary prone ECIRS from January 2019 to November 2023 were prospectively collected. All cases were performed in the prone position. Inclusion criteria were complex stone cases with stones in multiple calyces requiring either multiple accesses or multiple sessions to achieve stone-free status. Patients' mean age was 54.4 ± 12.39 years, while the mean stone size was 39.03 ± 13.93 mm. The mean operative time was 51.23 ± 17.75 min. Primary and final stone-free rates were 83.8% and 90.3%, respectively. In total, nine patients presented with postoperative complications, which were all Grade II ones. The holmium-YAG laser type during retrograde lithotripsy was associated with significantly shorter operative times compared to the thulium fiber laser. Nonpapillary prone ECIRS is a feasible, safe, and efficient approach for patients with specific stone and anatomy characteristics. The implementation of more, higher-evidence studies is of utmost importance so that safer conclusions can be drawn.

19.
Asian J Androl ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38265253

RESUMO

ABSTRACT: Peyronie's disease (PD) is characterized by abnormal penile curvature, and various surgical methods have been developed using different graft materials. However, there is currently no universal agreement on which type of graft is the best. The objective of this review was to evaluate the available literature and identify the most effective graft material for penile curvature correction in PD. A literature search was conducted using electronic databases, including PubMed, Scopus, and the Cochrane Library. The patients, intervention, comparison, and outcome (PICO) approach was used to define the eligibility of studies. Two authors independently selected studies, evaluated them, and extracted data. Random-effect models using the DerSimonian-Laird method were used. Most studies were single-arm studies and had a high risk of bias. Buccal mucosa grafts (BMG) were found to result in the highest penile straightening rates and were associated with the least de novo erectile dysfunction. TachoSil grafts demonstrated a high success rate in straightening despite a higher mean preoperative curvature, while Tutoplast grafts had a higher incidence of postoperative erectile dysfunction. BMG had the highest percentage of postoperative penile straightening. Overall, the TachoSil graft showed the best performance when preoperative curvature is taken into account. Based on the available literature, BMG appear to be the most effective for penile curvature correction in PD, but this is offset by the requirement for low preoperative curvature. The TachoSil graft shows the best overall performance when preoperative curvature is considered. Comparative randomized clinical trials are still needed to determine graft superiority.

20.
BJU Int ; 133(2): 141-151, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37461135

RESUMO

OBJECTIVE: To investigate the feasibility, safety and efficacy of holmium laser enucleation of the prostate (HoLEP) in the re-treatment setting (salvage HoLEP) and compare it to the primary HoLEP procedure that is commonly used for the treatment of benign prostate hyperplasia (BPH). MATERIALS AND METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, PubMed, Scopus, and Cochrane databases were systematically screened, from inception to 8 August 2022. Other potentially eligible studies were retrieved using the reference lists of the included studies. Retrospective and prospective studies, both comparative and non-comparative, were included. RESULTS: A total of 12 studies met the inclusion criteria and were included in the final qualitative synthesis. One study was prospective comparative (non-randomised), seven studies were retrospective comparative, and four studies were retrospective non-comparative or case series. In total, 831 patients were treated with salvage HoLEP in the above studies. Previous intervention before salvage HoLEP ranged among studies. The most commonly performed was transurethral resection of the prostate. Intraoperative parameters of salvage HoLEP were comparable with those reported during primary HoLEP, while all postoperative outcomes were significantly improved after salvage HoLEP and were similar with those observed after primary HoLEP. No major complications were noted after salvage HoLEP according to Clavien-Dindo classification. CONCLUSIONS: Salvage HoLEP after previous interventions for treating recurrent or residual BPH is a feasible, safe, and efficient procedure. Data presented in selected studies, along with the holmium laser's physical properties to resect more tissue and to dissect along the true anatomical plane of BPH, render HoLEP an ideal salvage treatment modality for recurrent or residual BPH symptoms.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Humanos , Masculino , Hólmio , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Estudos Prospectivos , Próstata , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Ressecção Transuretral da Próstata/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA