Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Anaesthesiol ; 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38095489

RESUMO

BACKGROUND: Continuous interscalene brachial plexus block (ISB) is widely used for arthroscopic shoulder surgery, but the incidence of hemidiaphragmatic paresis (HDP) has been reported to reach 100%. Several methods, including injections distal to the C5-C6 nerve roots, have been attempted to reduce the HDP incidence. However, catheter placement distal to the C5-C6 nerve roots interferes with the surgical site. OBJECTIVE: Our primary objective was to describe a new technique, the supraclavicular brachial plexus block (SCB), using the proximal longitudinal oblique approach (PLO-SCB), which can facilitate catheter placement and, when compared with ISB, to test whether this would provide noninferior analgesia and spare the phrenic nerve. DESIGN: Prospective, randomised, double-blind study. SETTING: Operating rooms, postanaesthesia care unit, and wards. PATIENTS: Seventy-six patients aged 20 to 80 years scheduled for arthroscopic shoulder surgery. INTERVENTIONS: Patients were randomly assigned to the continuous PLO-SCB (n = 40) or the continuous ISB (n = 40) groups. All patients received an initial low-volume single-injection (5 ml 0.75% ropivacaine) followed by a patient-controlled infusion of 0.15% ropivacaine. MAIN OUTCOME MEASURES: The primary outcomes were the incidence of HDP and pain scores. Secondary outcomes were respiratory function, postoperative analgesic consumption, sensory and motor function, and complications. RESULTS: The HDP incidence was significantly lower in the PLO-SCB group than in the ISB group at 30 min after block injection: 0% (0 of 38 patients) and 73.7% (28 of 38 patients), respectively (P < 0.001). Similarly, at 24 h after surgery, the incidences were 23.7% (9 of 38 patients) and 47.4% (18 of 38 patients) in the PLO-SCB and ISB groups, respectively (P = 0.002). Median [IQR] NRS pain scores at rest measured after surgery in the ISB and PLO-SCB groups were similar: immediately after surgery, 1 [0 to 2] vs. 1 [0 to 1], P = 0.06); at 30 min, 2 [0.25 to 2] vs. 1 [0 to 2], P = 0.065); and at 24 h 2 [0.25 to 3] vs. 1 [0 to 3], P = 0.47, respectively. CONCLUSION: For major shoulder surgery, compared with continuous ISB, continuous PLO-SCB was more sparing of diaphragmatic and respiratory function while providing noninferior analgesia. Catheter placement via the PLO approach is feasible without interfering with the surgical field. TRIAL REGISTRATION: Registered by the Clinical Trial Registry of Korea (Seoul, Korea; KCT0004759, http: cris.nih.go.kr, principal investigator: Hyungtae Kim).

2.
BMC Nurs ; 21(1): 319, 2022 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-36419116

RESUMO

BACKGROUND: This study investigated the knowledge and attitude of surgical ward nurses toward patient-controlled analgesia (PCA) to develop educational material for nurses on the use of PCA. METHODS: This study was a cross-sectional study comprising 120 nurses from eight surgical wards in a tertiary hospital in South Korea. A questionnaire addressing 6 domains of knowledge of and attitudes towards PCA was conducted over 1 week and analyzed using descriptive and inferential statistical methods. Knowledge was measured on a categorical scale of 0 and 1 (20 points), and attitude was measured on a Likert scale of 1 to 4 points (60 points). RESULTS: The total score quantifying the knowledge of and attitudes toward PCA of surgical ward nurses was 59.5 ± 5.5 out of 80.0 points. The average age of the subjects was 28.58 ± 5.68 years old, and nurses above the age of 28 had significantly greater knowledge and better attitudes (61.7 ± 5.5) than those below the age of 28 (57.9 ± 4.9) (p < .001). Nurses working on the upper abdominal surgical ward had significantly greater knowledge (16.2 ± 1.9) than nurses working on other wards (thorax: 14.0 ± 2.3, lower abdominal: 15.4 ± 1.9, and musculoskeletal: 14.5 ± 2.2) (p = .001). Nurses who received education about PCA had significantly better attitudes (45.3 ± 4.6) than those who did not (41.3 ± 3.5) (p < .001). The average correct answer rate for knowledge of opioid analgesics was lower (68.2%) than that for knowledge of the basic configuration of PCA equipment (73.3%) and areas to be identified and managed when using PCA (84.6%), and there was a significant correlation with attitudes toward side effect management (p < .05, r = .19). CONCLUSIONS: There was a significant correlation between the knowledge and attitude of nurses regarding opioid use in PCA. Older nurses with greater clinical experience on the surgical wards who had received PCA education had a better attitude toward PCA. Therefore, newly trained nurses on surgical wards with no experience of PCA education should undergo an intensive education program on opioid analgesics used in PCA.

3.
Anesth Analg ; 129(3): 720-725, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31425211

RESUMO

BACKGROUND: Patient-controlled analgesia (PCA) is one of the most popular and effective methods for managing postoperative pain. Various types of continuous infusion pumps are available for the safe and accurate administration of analgesic drugs. Here we report the causes and clinical outcomes of device-related errors in PCA. METHODS: Clinical records from January 1, 2011 to December 31, 2014 were collected by acute pain service team nurses in a 2715-bed tertiary hospital. Devices for all types of PCA, including intravenous PCA, epidural PCA, and nerve block PCA, were included for analysis. The following 4 types of infusion pumps were used during the study period: elastomeric balloon infusers, carbon dioxide-driven infusers, semielectronic disposable pumps, and electronic programmable pumps. We categorized PCA device-related errors based on the error mechanism and clinical features. RESULTS: Among 82,698 surgical patients using PCA, 610 cases (0.74%) were reported as human error, and 155 cases (0.19%) of device-related errors were noted during the 4-year study period. The most common type of device-related error was underflow, which was observed in 47 cases (30.3%). The electronic programmable pump exhibited the high incidence of errors in PCA (70 of 15,052 patients; 0.47%; 95% confidence interval, 0.36-0.59) among the 4 types of devices, and 96 of 152 (63%) patients experienced some type of adverse outcome, ranging from minor symptoms to respiratory arrest. CONCLUSIONS: The incidence of PCA device-related errors was <0.2% and significantly differed according to the infusion pump type. A total of 63% of patients with PCA device-related errors suffered from adverse clinical outcomes, with no mortality. Recent technological advances may contribute to reducing the incidence and severity of PCA errors. Nonetheless, the results of this study can be used to improve patient safety and ensure quality care.


Assuntos
Analgesia Controlada pelo Paciente/efeitos adversos , Analgésicos Opioides/efeitos adversos , Falha de Equipamento , Erros de Medicação/efeitos adversos , Centros de Atenção Terciária , Analgesia Controlada pelo Paciente/tendências , Feminino , Humanos , Bombas de Infusão/efeitos adversos , Bombas de Infusão/tendências , Masculino , Erros de Medicação/tendências , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção Terciária/tendências
4.
Atherosclerosis ; 272: 233-239, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29482886

RESUMO

BACKGROUND AND AIMS: Hyperuricemia was frequently noted in subjects with a high risk of cardiovascular disease (CVD). This study aimed to elucidate whether serum uric acid (SUA) is associated with development of moderate coronary artery calcification in generally healthy adults. METHODS: A total of 9297 subjects underwent multidetector CT for the evaluation of CAC at least two times during their annual health examinations. Among them, 4461 participants without CVD history and who had no (scores 0) or minimal CAC (scores 1-10) in their first examination were enrolled. The association between SUA as a continuous and categorical variable and development of moderate coronary artery calcification (CAC score > 100) was assessed by Cox regression analysis. Receiver-operating characteristic (ROC) curves were constructed to investigate the diagnostic efficacy of SUA. RESULTS: During a median follow-up of 4.1 years, 131 incident cases of moderate calcification developed. Baseline SUA concentration was significantly higher in subjects with progression to moderate coronary artery calcification (6.6 ±â€¯1.3 vs. 5.8 ±â€¯1.3 mg/dL, p < 0.001). SUA as a continuous variable (per 1 mg/dL) and divided into quartiles was positively associated with a higher risk of development of moderate calcification after adjustment for conventional CVD risk factors. The addition of SUA to the conventional CVD risk factors improved the predictive power for development of moderate coronary artery calcification. CONCLUSIONS: SUA was an independent predictor for development of moderate coronary artery calcification in subjects with no or minimal calcification.


Assuntos
Calcinose/sangue , Doença da Artéria Coronariana/sangue , Vasos Coronários/patologia , Ácido Úrico/sangue , Doenças Cardiovasculares , Feminino , Seguimentos , Humanos , Hiperuricemia/complicações , Masculino , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Curva ROC , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA