Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ Cardiovasc Imaging ; 4(5): 506-13, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21730026

RESUMO

BACKGROUND: Accurate quantification of mitral regurgitation (MR) is important for patient treatment and prognosis. Three-dimensional echocardiography allows for the direct measure of the regurgitant orifice area (ROA) by 3D-guided planimetry of the vena contracta area (VCA). We aimed to (1) establish 3D VCA ranges and cutoff values for MR grading, using the American Society of Echocardiography-recommended 2D integrative method as a reference, and (2) compare 2D and 3D methods of ROA to establish a common calibration for MR grading. METHODS AND RESULTS: Eighty-three patients with at least mild MR underwent 2D and 3D echocardiography. Direct planimetry of VCA was performed by 3D echocardiography. Two-dimensional quantification of MR included 2D ROA by proximal isovelocity surface area (PISA) method, vena contracta width, and ratio of jet area to left atrial area. There were significant differences in 3D VCA among patients with different MR grades. As assessed by receiver operating characteristic analysis, 3D VCA at a best cutoff value of 0.41 cm(2) yielded 97% of sensitivity and 82% of specificity to differentiate moderate from severe MR. There was significant difference between 2D ROA and 3D VCA in patients with functional MR, resulting in an underestimation of ROA by 2D PISA method by 27% as compared with 3D VCA. Multivariable regression analysis showed functional MR as etiology was the only predictor of underestimation of ROA by the 2D PISA method. CONCLUSIONS: Three-dimensional VCA provides a single, directly visualized, and reliable measurement of ROA, which classifies MR severity comparable to current clinical practice using the American Society of Echocardiography-recommended 2D integrative method. The 3D VCA method improves accuracy of MR grading compared with the 2D PISA method by eliminating geometric and flow assumptions, allowing for uniform clinical grading cutoffs and ranges that apply regardless of etiology and orifice shape.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
2.
Eur Heart J ; 29(20): 2526-35, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18263866

RESUMO

AIMS: Two-dimensional echocardiographic (2DE) continuity-equation derived aortic valve area (AVA) in aortic stenosis (AS) relies on non-simultaneous measurement of left ventricular outflow tract (LVOT) velocity and geometric assumptions of LVOT area, which can amplify error, especially in upper septal hypertrophy (USH). We hypothesized that real-time three-dimensional echocardiography (RT3DE) can improve accuracy of AVA by directly measuring LVOT stroke volume (SV) in one window. METHODS AND RESULTS: RT3DE colour Doppler and 2DE were acquired in 68 AS patients (74 +/- 12 yrs) prospectively. SV was derived from flow obtained from a sampling curve placed orthogonal to LVOT (Tomtec Imaging). Agreement between continuity-equation derived AVA by RT3DE (AVA(3D-SV)) and 2DE (AVA(2D)) and predictors of discrepancies were analysed. Validation of LVOT SV was performed by aortic flow probe in a sheep model with balloon inflation of septum to mimic USH. There was only modest correlation between AVA(2D) and AVA(3D-SV) (r = 0.71, difference 0.11 +/- 0.23 cm(2)). The degree of USH was significantly associated with difference in AVA calculation (r = 0.4, P = 0.005). In experimentally distorted LVOT geometry in sheep, RT3DE correlated better with flow probe assessment (r = 0.96, P < 0.001) than 2DE (r = 0.71, P = 0.006). CONCLUSION: RT3DE colour Doppler-derived LVOT SV in the calculation of AVA by continuity equation is more accurate than 2D, including in situations such as USH, common in the elderly, which modify LVOT geometry.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Volume Sistólico/fisiologia , Idoso , Animais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Função Ventricular Esquerda/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA