Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Glob Antimicrob Resist ; 27: 160-166, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34496323

RESUMO

OBJECTIVES: This study aimed to describe the electrocardiographic and echocardiographic status of chronic Chagas disease (cChD) patients treated with nifurtimox. METHODS: An observational study was performed in 146 cChD patients followed over a mean of 7.9 years. RESULTS: Of the 146 patients, 41 (28.1%) with normal electrocardiogram (ECG) at baseline maintained this condition, 34 (23.3%) with altered ECG at baseline normalised the alterations, and 46 (31.5%) with ECG abnormalities at baseline maintained this condition [23 (15.8%) with small alterations]. Finally, 25 cases (17.1%) in indeterminate phase altered the ECG. Differences before and after follow-up (P < 0.001) were found. The percentage of beneficial treatment was different than expected by chance (Z = 4.8; P < 0.001) and the annual percentage of cases that developed ECG alterations was lower than that of a historical cohort of untreated patients (P < 0.001). An echocardiogram was performed in 68 patients with baseline ECG alterations. The ejection fraction (EF) was normal in 57 (83.8%) and abnormal in 11 (16.2%). In 38 patients with ECG abnormalities that did not progress after treatment, EF and segmental motility (SM) were normal in 31 (81.6%) and 26 (68.4%), respectively. In 17 patients with ECG abnormalities, EF and SM were normal in 15 (88.2%) and 14 (82.4%) cases, respectively. CONCLUSION: Less progression to cardiomyopathy compared with a historical untreated cohort as well as the EF/SM results in patients with abnormal ECG that did not progress and in indeterminate cChD that altered the ECG suggests a beneficial effect of nifurtimox.


Assuntos
Cardiomiopatia Chagásica , Doença de Chagas , Cardiomiopatia Chagásica/diagnóstico por imagem , Cardiomiopatia Chagásica/tratamento farmacológico , Doença de Chagas/tratamento farmacológico , Chile , Ecocardiografia , Eletrocardiografia , Seguimentos , Humanos , Nifurtimox/uso terapêutico
2.
Int J Cardiol ; 201: 210-1, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26298382

RESUMO

Mitral valve replacement with preservation of chordae tendineae and papillary muscles is a well-known technique which has proved beneficial by reducing postoperative left ventricular remodeling and preserving left ventricular function. This advantage has been demonstrated in functional mitral valve regurgitation as well as mitral valve regurgitation due to rheumatic disease. Regarding complications of this technique, several of them have been reported, papillary muscle rupture being one of them. We describe a clinical case of this weird but possible kind of complication.


Assuntos
Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/diagnóstico , Músculos Papilares/patologia , Trombose/diagnóstico , Idoso , Diagnóstico Diferencial , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Insuficiência da Valva Mitral/cirurgia , Músculos Papilares/cirurgia , Trombose/cirurgia
3.
Radiol. bras ; 31(6): 349-54, dez. 1998. ilus, tab
Artigo em Português | LILACS | ID: lil-267841

RESUMO

Resumo: Este estudo visa fazer a correlaçäo entre a clínica, a ecocardiografia transtorácica (ETT) e a ecocardiografia transesofgica (ETE) no diagnóstico diferencial dos defeitos do septo interatrial (DSIA) e hipertensäo pulmonar (HP) em adultos. Realizamos ETT a ETE em 30 pacientes com diagnóstico de DSIA baseado em critérios de ausculta cardíaca, radiológicos e eletrocardiográficos. Três critérios, em 16 pacientes (grupo B). Foram determinados a sensibilidade, a especificidade, a acurácia e os valores preditivos positivo e negativo para a ETT, admitindo-se os resultados da ETE como ''gold standard''. A sensibilidade da ETT para o diagnóstico de DSIA é baixa 50 (por cento), a especificidade é de 75-90 (por cento), a acurária de 60-66 (por cento), o valor preditivo positivo de 75-83 (por cento), e o valor preditivo negativo de 37-75 (por cento), näo sendo capaz de diagnosticar os DSIAs tipo seio venoso. Catorze pacientes 46,6 (por cento) apresentaram diagnóstico final de HP, näo estando relacionada a DSIA


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Ecocardiografia , Ecocardiografia Transesofagiana , Comunicação Interatrial , Comunicação Interatrial/diagnóstico , Hipertensão Pulmonar/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA