Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Eur Ann Otorhinolaryngol Head Neck Dis ; 138(5): 391-395, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33384280

RESUMO

The pterygopalatine fossa and infratemporal fossa are spaces located under the skull base, housing important neurovascular structures. Surgical access to these spaces is challenging because of their deep location and complex anatomy. Their surgical access has been classically carried out through multiple craniofacial approaches until the advent of endoscopic endonasal surgery at the end of the XXth century. Our goal is to describe the transmaxillary-transsphenoidal-transpterygoid approach to the pterygopalatine and infratemporal fossae through endonasal endoscopic surgery based on anatomo-surgical dissection and an illustrative clinical case. We conclude that after careful radiologic evaluation of the feasibility of this technique, the endonasal endoscopic access to these spaces for tumor resection is efficient with reduced surgical morbidities. The endonasal approach is versatile and can be fashioned according to the nature and extent of the lesion.


Assuntos
Fossa Infratemporal , Endoscopia , Humanos , Nariz , Fossa Pterigopalatina/cirurgia , Base do Crânio
2.
Eur Ann Otorhinolaryngol Head Neck Dis ; 138(2): 89-92, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32631723

RESUMO

OBJECTIVES: To evaluate biostatistics in scientific articles published in the European Annals of Otorhinolaryngology Head & Neck Diseases. MATERIALS AND METHODS: Retrospective analysis of 76 scientific articles published in 2018 and 2019. The main goal was to describe the percentage of articles using biostatistics and to explore for potential associations with the article's main characteristics. Secondary goals were, within the group of articles using statistical tests, to describe the type of statistics used, the assessment of normality in case of comparison of mean values, the p-value threshold for significance, the use of confidence intervals, and power analysis. RESULTS: Statistics were used in 73.7% of articles, without any significant association with main characteristics. Within the group of articles using statistics, the tests used were parametric, non-parametric and not specified in 77.7%, 51.4% and 1.8% of cases, respectively. Normality was checked in 14.2% of article using parametric tests to evaluate mean values. The p-value significance threshold was set at .05, .01, .005 levels and not defined in 60.7%, 1.8%, 1.8% and 35.7% of articles, respectively, while confidence intervals and power analyses were documented in 10.7% and 5.3%, respectively. CONCLUSION: This article underlines the need for better use of statistics in the European Annals of Otorhinolaryngology Head & Neck Diseases, to improve the quality of scientific articles published in the organ of written expression of the French and International French-speaking Societies of Otorhinolaryngology, and to support the ongoing move toward better medical science.


Assuntos
Otolaringologia , Redação , Bioestatística , Correlação de Dados , Humanos , Estudos Retrospectivos
3.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S11-S18, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32863156

RESUMO

OBJECTIVE: Multi-centre study of the National French Registry (EPIIC) of patients with cochlear implants, focusing on infants who were operated-on under the age of 24 months between 2012 and 2016. PATIENTS AND METHODS: A total of 615 profoundly deaf infants, who received cochlear implants (CIs) before their second birthday, were included in the registry by different CI centers. Epidemiological, surgical, speech therapy and school, follow-up data were included in the registry, 12, 24, 36 and 48 months thereafter. The following parameters were studied: type of implantation (uni- or bilateral), complications, cause of deafness, category of auditory perception (CAP), Open-set word recognition score (OSW), speech intelligibility rating, lexical comprehension with EVIP (Peabody), communication mode and type of schooling. Bilateral simultaneous CI (BiCI) and unilateral CI (UniCI) groups were compared. RESULTS: There were 744 implantations. The explantation-reimplantation rate, within the four-year follow-up, was just 3.6%. Mean implantation age was 16.0 months, and similar in the two groups (BiCI/UniCI). A total of 51% of children had their first implant between 12 and 18 months, and 15% before 12 months. Implantation was unilateral in 52% of cases. Fifty-six percent of the bilateral procedures were sequential, with a mean delay of 16.8 months for the second implantation. The cause of deafness was unknown in 52% of cases. Of the 48% (297/615) of attributed cases, 32% had clear genetic causes. The remaining deafness was due to cytomegalovirus (CMV, 8%), inner-ear malformation (5%) and meningitis (3%). The main complications were from infections (47%) and internal device failure (25%). Four years post-operation, 84% of the UniCI and 75% of BiCl groups had a CAP≥5, and 83% of UniCl and 100% BiCI had OSW≥80%. Furthermore 74% of UniCI and 77% of BiCI communicated orally and 85% of UniCI and 90% of BiCI integrated into mainstream schooling. CONCLUSION: The French Registry of cochlear implants (EPIIC) is the only such national registry in the world. Our analysis illustrates the immediate benefits of, either single or double, cochlear implantation for language, perception skills and schooling.


Assuntos
Percepção Auditiva , Linguagem Infantil , Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Surdez/reabilitação , Sistema de Registros/estatística & dados numéricos , Fatores Etários , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Implantes Cocleares/efeitos adversos , Comunicação , Correção de Deficiência Auditiva/instrumentação , Correção de Deficiência Auditiva/estatística & dados numéricos , Surdez/etiologia , Remoção de Dispositivo/estatística & dados numéricos , Educação de Pessoas com Deficiência Auditiva/métodos , Educação de Pessoas com Deficiência Auditiva/estatística & dados numéricos , Seguimentos , França , Humanos , Lactente , Recém-Nascido , Inclusão Escolar/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Instituições Acadêmicas , Inteligibilidade da Fala , Fonoterapia/estatística & dados numéricos , Fatores de Tempo
4.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S5-S9, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32891589

RESUMO

Cochlear and brainstem implants have been included on the list of reimbursable products (LPPR) in France since March of 2009. The implants were initially inscribed for 5 years, after which an application for renewal with the French National Commission for the Evaluation of Medical Devices and Health Technologies (Commission Nationale d'évaluation des dispositifs médicaux et des technologies de santé - CNEDiMTS) was required [Haute Autorité de santé, 2009]. Upon registration to the list of reimbursable products, the companies and the reference centers for cochlear and brainstem implants were asked to set up a post-registration registry called EPIIC. This article reports the evolution in the EPIIC registry of the general indicators for 5051 patients over the five years from 2012-2016.


Assuntos
Implantes Auditivos de Tronco Encefálico/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Comitês Consultivos/organização & administração , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Implantes Auditivos de Tronco Encefálico/economia , Implante Coclear/estatística & dados numéricos , Implantes Cocleares/economia , Segurança Computacional , Bases de Dados como Assunto , Aprovação de Equipamentos/legislação & jurisprudência , Remoção de Dispositivo/estatística & dados numéricos , França , Guias como Assunto/normas , Setor de Assistência à Saúde/economia , Setor de Assistência à Saúde/legislação & jurisprudência , Humanos , Lactente , Recém-Nascido , Reembolso de Seguro de Saúde , Controle de Qualidade , Padrões de Referência , Fatores de Tempo
5.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S45-S49, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32826202

RESUMO

This study aims to determine the frequency and causes of cochlear explants with re-implantation (ERI) after 5 years' follow up of the patients included in the French national EPIIC (étude post-inscription des implants cochléaires) registry tracking patients with cochlear implantation. This multicenter, descriptive prospective study was conducted on 5051 patients enrolled in the EPIIC database between January 2012 and December 2016. Ninety-five patients (1.9%) received a primary implant and an ERI during the study. Of these, four benefitted from two ERIs. The number of ERIs was significantly higher in the pediatric population than among adults. The explantation and reimplantation were performed simultaneously in 86% of cases. The reasons for explantation were: in 46.4% of cases linked to a malfunction of the implant, and in 39.3% of cases for medical or surgical reasons. The number of electrodes inserted was significantly higher after the ERI than after the first implantation. There was just one post-ERI infection for these 95 explanted and re-implanted patients. As well as explantation with reimplantation rarely being necessary, it generally presents no major surgical difficulty and in most cases it allows a better integration than in the first implantation.


Assuntos
Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Implantes Cocleares/efeitos adversos , França , Humanos , Lactente , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese , Reimplante/estatística & dados numéricos , Fatores de Tempo , Adulto Jovem
6.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S51-S56, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32739279

RESUMO

OBJECTIVES: Assessment of the incidence and results of bilateral cochlear implantation in adults and children in France. MATERIALS AND METHODS: Multicenter retrospective study of data in the French national registry of cochlear implantations from January 1st 2012 to December 31st 2016. Functional results from CAP (Category of Auditory Performance) questionnaires and speech audiometry tests, with mono- and di-syllabic word-lists, were compared before and after implantation. Speech audiometry tests were carried out against a noisy background, except before simultaneous implantations. RESULTS: Nine hundred and forty two bilateral cochlear implantations were performed during this period, that is, 16.4% of all cochlear implantations. Five hundred and eighty eight bilateral implantations were performed sequentially. 59% of the bilateral implantations were performed in children. Bilateral implants significantly improved CAP scores in all cases (P<0.001). Auditory performance, with the two types of word-list, were significantly improved after simultaneous implantation (P<0.01). After sequential implantation, the speech discrimination score, already very good with the first implant, reached 63±26% [0-100] with monosyllabic word lists, and 72±28% [0-100] with dissyllabic words. There were more complications due to surgery in bilateral cases than in the entire population of cochlear recipients (9.1% vs 6.4%, P<0.02). CONCLUSION: Hearing is significantly improved by simultaneous cochlear implantation. For sequential implantation, at one year, when auditory results were already excellent from the first implant, in the bimodal condition CAP scores were significantly improved, although there was no further change in speech audiometry in noise.


Assuntos
Implante Coclear/métodos , Implantes Cocleares/estatística & dados numéricos , Surdez/reabilitação , Sistema de Registros/estatística & dados numéricos , Adulto , Audiometria da Fala/métodos , Percepção Auditiva , Criança , Implante Coclear/efeitos adversos , Implante Coclear/estatística & dados numéricos , Surdez/etiologia , Feminino , França , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Testes de Discriminação da Fala/estatística & dados numéricos
7.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S27-S35, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32763084

RESUMO

OBJECTIVE: Evaluate in France the outcomes of cochlear implantation outside the selection criteria, off-label. MATERIAL AND METHODS: This is a prospective cohort study including adults and children having received a cochlear implant (CI) in an off-label indication, that is outside the criteria established by the "Haute Autorité de santé (HAS)" in 2012. The data was collected from the "EPIIC" registry on recipients who received CIs in France between 2011 and 2014. Speech audiometry was performed at 60dB preimplantation and after one year of CI use, as well as an evaluation of the scores of the quality of life with the APHAB questionnaire, the scores for CAP and the professional/academic status in pre- and post-implantation conditions. Major and minor complications at surgery have been recorded. RESULTS: In total, 590 patients (447 adults and 143 children) with an off-label indication for CIs were included in this study from the EPIIC registry (11.7% of the whole cohort of EPIIC). For adults, the median percentage of comprehension using monosyllabic word lists was 41% in preimplantation condition versus 53% after one year of CI use (P<0.001) and 60% versus 71% in dissyllabic word lists (P<0.001). The CAP scores were 5 versus 6 in pre- and post-implantation conditions respectively (P<0.001) and the APHAB scores were statistically lower after implantation (P<0.001). In the children cohort, the median percentage of comprehension using monosyllabic word lists was 51% in preimplantation condition and 65% after CI (P<0.001), and 48% versus 82% (P<0.001) for dissyllabic word lists. The CAP scores were 5 versus 7 respectively in pre- and post-CI conditions (P<0.001). Thirty-two minor complications (5.4%) and 17 major complications (2.8%) were reported in our panel of off-label indication patients. CONCLUSION: These results suggest that a revision of the cochlear implantation candidacy criteria is necessary to allow more patients with severe or asymmetric hearing loss to benefit from a CI when there is an impact on quality of life despite the use of an optimal hearing aid.


Assuntos
Implante Auditivo de Tronco Encefálico/estatística & dados numéricos , Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Perda Auditiva/reabilitação , Seleção de Pacientes , Sistema de Registros/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Audiometria da Fala/métodos , Criança , Pré-Escolar , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Feminino , França/epidemiologia , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Uso Off-Label/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Qualidade de Vida , Adulto Jovem
8.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S37-S43, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32861600

RESUMO

OBJECTIVES: The aim of this study was to evaluate peri- and post-operative complications related to cochlear implantations. We searched for risk factors predicting these complications and analyzed the complications in the youngest and most elderly. STUDY DESIGN: Retrospective analysis of cochlear implant patients. MATERIALS AND METHODS: All patients who underwent cochlear implantation in France between January 2012 and December 2016 were anonymized and registered in the EPIIC database. This population included 3483 adults and 2245 children. Their demographic and surgical data and their incidence of peri- or post-operative complications, including their severity, whether major or minor, were all indicated. RESULTS: The global complication rate was 6.84%. The risk of complication was higher in initial implantation versus reimplantation (P<0.0001). The risk was also higher for bilateral implantation versus unilateral (P<0.0001). Complications were more frequent for patients with cochlear malformation (P=0.002). There was no difference in complication rates across age groups; babies under 1 year old, and the elderly over 80 and even over 90, did not have more complications than the rest of the population. Patients treated in the daily care unit had no more complications than those who were hospitalized for one night or more (P=0.64). CONCLUSION: Cochlear implantation is a safe technique with a low incidence of complications. The absence of increased risk in patients at the extremes of the age spectrum justifies offering this solution to all, without age limitation.


Assuntos
Implante Coclear/efeitos adversos , Perda Auditiva/reabilitação , Complicações Intraoperatórias/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Cóclea/anormalidades , Implante Coclear/métodos , Hospital Dia/estatística & dados numéricos , França/epidemiologia , Perda Auditiva/etiologia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Lactente , Pessoa de Meia-Idade , Reoperação/efeitos adversos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
9.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S57-S63, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32792302

RESUMO

This study concerns the results of cochlear implantation in children and adults from French cochlear implantation centers, monitored at one, two and three years by the Cochlear Implant French Registry EPIIC. This multicenter study enrolled 2603 subjects (1667 adults and 936 children) implanted in one ear. The following parameters were studied: hearing overall performances, monosyllabic or dissyllabic word perception, speech intelligibility, self-assessment questionnaire of Cochlear Implant (CI) benefits (Abbreviated profile of Hearing aid Benefit); professional activity and schooling. This study confirms the ceiling effect in adults' performances after the 1st year and the progressive growth in children's performances. It also shows that the contralateral hearing aid enhances performances compared to the CI alone condition, in all follow-up sessions. The French register of CIs is the only worldwide register of systematic follow-up on a period of three years and more of all adults and children implanted in a country.


Assuntos
Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Surdez/reabilitação , Qualidade de Vida , Sistema de Registros/estatística & dados numéricos , Adolescente , Adulto , Fatores Etários , Percepção Auditiva , Criança , Pré-Escolar , Educação , Emprego , Seguimentos , França , Humanos , Lactente , Recém-Nascido , Autoavaliação (Psicologia) , Inteligibilidade da Fala , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
10.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137 Suppl 1: S19-S25, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32773333

RESUMO

OBJECTIVES: To analyze the performance of cochlear implants in French patients aged 65 and over, implanted between 2012 and 2016, using data from the French national registry for cochlear implants (EPIIC). MATERIALS AND METHODS: The French national registry incorporates patient data from before implantation and for three years after implantation, stratified in different age groups (18-39, 40-64years, 65-74years and>75years). Here, we assessed the latter two categories. Hearing was assessed using mono- and disyllabic words in a silent background. The Category of Auditory Performance (CAP) scale was also implemented and subjects took the Abbreviated Profile of Hearing Aid Benefit (Aphab) questionnaire. RESULTS: The population aged over 65 accounted for 38% (n=1193) of the 3178 adult implanted patients. The performance for mono- and disyllabic words in silence, the CAP scores and the APHAB questionnaire answers for ease of communication, background noise and reverberation were dramatically improved at one year post-implantation (P<0.0001 for each score) and remained stable between one and three years thereafter. The percentage improvement was similar across all age groups. The scores for loud-noise intolerance did not change after cochlear implantation in any age group. CONCLUSION: Cochlear implants improve hearing and communication in subjects aged 65 and over, with comparable efficiency to that achieved in younger subjects. Cochlear implantation should thus be proposed whenever hearing aids provide only limited benefit. However, between 2012 and 2016, cochlear implantation was given to less than 1% of the French population aged 65 and over with profound deafness.


Assuntos
Implante Coclear/estatística & dados numéricos , Implantes Cocleares/estatística & dados numéricos , Perda Auditiva/reabilitação , Sistema de Registros/estatística & dados numéricos , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Percepção Auditiva , Implante Coclear/métodos , Comunicação , Feminino , França , Inquéritos Epidemiológicos , Perda Auditiva/etiologia , Testes Auditivos/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
11.
Eur Ann Otorhinolaryngol Head Neck Dis ; 137(3): 213-216, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31866273

RESUMO

INTRODUCTION: Osteomas of the internal auditory canal are rarely reported in the literature. Patients may complain of disabling symptoms of dizziness, hearing loss, and vestibular dysfunction. We report the case of a patient with bilateral osteomas of the internal auditory canal (IAC) associated with bilateral neurovascular compression mainly affecting the right cochleovestibular nerve (VIII) and right anterior inferior cerebellar artery (AICA). OBSERVATION: This 75-year-old woman patient complained of disabling paroxysmal vertigo, typewriter tinnitus and hearing loss of the right ear. Temporal bone computed tomography showed bilateral osteoma arising from the posterior superior wall of the IAC. MRI sequences of the right VIII demonstrated compression by the right AICA against the inferior wall of the narrowed IAC. Treatment with oxcarbazepine allowed marked and lasting improvement of the patient's symptoms. CONCLUSION: To our knowledge, this is the first description of an ipsilateral neurovascular compression syndrome of the VIII secondary to the presence of an osteoma narrowing the IAC.


Assuntos
Síndromes de Compressão Nervosa/etiologia , Osteoma/complicações , Neoplasias Cranianas/complicações , Osso Temporal , Nervo Vestibulococlear , Idoso , Orelha Interna , Feminino , Humanos , Osteoma/patologia , Neoplasias Cranianas/patologia
12.
Eur Ann Otorhinolaryngol Head Neck Dis ; 136(6): 469-473, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31699624

RESUMO

OBJECTIVES: To evaluate the use of P-values and the terms "significant", "non-significant" and "suggestive" in Abstracts in the European Annals of Otorhinolaryngology, Head & Neck Diseases. MATERIALS AND METHODS: Consecutive articles accepted for publication during the period January 2016 - February 2019 were systematically reviewed. Main goal: descriptive analysis of the citation of P-values and use of the terms "significant", "non-significant" and "suggestive" in Abstracts. Secondary goal: analytic study of: (i) correlations between citation of a P-value and the main characteristics of authors and topics; and (ii) misuse of the terms "significant", "non-significant" and "suggestive" with respect to cited P-values, and correlations with author and topic characteristics. RESULTS: In all, 91 articles were included. P-values and the terms "significant", "non-significant" and "suggestive" were cited in 35.1%, 41.7%, 10.9% and 0% of Abstracts, respectively. Citing a P-value did not significantly correlate with author or topic characteristics. There were discrepancies between the terms "non-significant", "significant" and "suggestive" and P-values given in the body of the article in 57.1% of Abstracts, with 30.7% overestimation and 25.2% underestimation of results, without significant correlation with author or topic characteristics. CONCLUSION: Authors, editors and reviewers must pay particular attention to the spin resulting from inappropriate use of the terms "significant", "non-significant" and "suggestive" in Abstracts of articles submitted to the European Annals of Otorhinolaryngology, Head & Neck Diseases, to improve the rigor, quality and value of the scientific message delivered to the reader.


Assuntos
Indexação e Redação de Resumos/estatística & dados numéricos , Interpretação Estatística de Dados , Otolaringologia/estatística & dados numéricos , Publicações Periódicas como Assunto/estatística & dados numéricos , Editoração/estatística & dados numéricos , Correlação de Dados , Europa (Continente) , Controle de Qualidade , Terminologia como Assunto
13.
Eur Ann Otorhinolaryngol Head Neck Dis ; 136(2): 93-97, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30639598

RESUMO

OBJECTIVES: To analyze the etiologies, auditory consequences, diagnostic tools and therapeutic results of three often confused pathologies: acquired fibrous stenosis of the medial part of the external auditory canal (EAC), fibrous anterior tympanomeatal angle blunting, and lateralized tympanic membrane. MATERIAL AND METHODS: Retrospective study of 18 cases operated on over a 16-year period (14 patients: 7 female, 7 male; aged 11-64 years): 8 cases of medial EAC stenosis, 3 of blunting, and 7 of tympanic membrane lateralization. RESULTS: In all 3 pathologies, otoscopic and radiologic diagnosis was easily established, so that they could not be confused. All 3 induced>33dB conductive hearing loss. Medial EAC stenosis was secondary to chronic inflammation of the EAC, aggravated by surgery in 5 cases. Blunting was secondary to surgery altering the anterior tympanic annulus. Tympanic membrane lateralization was secondary to prior surgery without inflammatory process. Underlying EAC cholesteatoma was found in 3 cases of medial stenosis and in 1 case of blunting. Surgical results were disappointing in medial stenosis, with 62.5% recurrence and mean functional gain of 9dB, and in blunting, with 66.7% recurrence and mean functional gain of 6dB; auditory results were, however, good in these 2 pathologies when there was no recurrence of fibrosis. Results were significantly better in lateralized tympanic membrane, with 28.6% recurrence and mean functional gain of 16dB. CONCLUSION: The good results obtained in tympanic membrane lateralization seem to justify surgery in patients bothered by their hearing loss. The indication is more questionable in cases of medial fibrous stenosis and blunting, although significant auditory improvement is achieved in case of surgical success.


Assuntos
Meato Acústico Externo/patologia , Membrana Timpânica/patologia , Adolescente , Adulto , Criança , Colesteatoma da Orelha Média/diagnóstico , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Feminino , Fibrose , Perda Auditiva Condutiva/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Otite/complicações , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Recidiva , Resultado do Tratamento , Membrana Timpânica/cirurgia , Perfuração da Membrana Timpânica/cirurgia , Timpanoplastia/efeitos adversos , Adulto Jovem
15.
Eur Ann Otorhinolaryngol Head Neck Dis ; 135(6): 417-420, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30431000

RESUMO

OBJECTIVE: Cochlear implantation may have a detrimental effect on vestibular function and residual hearing. Our goal was to investigate the impact of cochlear implantation on peripheral vestibular function and the symptomatology that ensues. MATERIAL AND METHODS: A prospective observational study included all adults undergoing cochlear implantation by the same operator between July 2014 and December 2015, with pre- and postoperative (4 months) neurovestibular balance examination comprising a questionnaire and clinical tests [head impulse test (HIT), head-shaking test (HST), skull vibration test (SVT)] and instrumental tests [caloric test of the lateral semicircular canal and cervical vestibular-evoked myogenic potentials (cVEMP)]. RESULTS: Twenty-two patients were included, with a mean age of 62 years and sex-ratio of 1.2. Before implantation, 50% of subjects (n=11) reported at least one episode of vertigo associated with balance disorder during their life. After implantation, there were 11 cases of vertigo but only one patient described persistent discomfort related to vertigo 4 months after surgery. Patients with impaired vestibular function after 4 months, taking all symptoms together, were all aged more than 75 years. HIT was abnormal in 18% of cases before implantation and in 59% after (P=NS). HST showed nystagmus in one patient both before and after surgery. Only 18% of patients showed nystagmus induced by SVT before surgery, increasing to one-third after surgery (P=NS). Caloric test of the lateral canal showed hypofunction in 50% of cases before surgery, including 10% of cases with areflexia. This rate increased after surgery to 58%, with 18% areflexia (P=NS). cVEMPs were not detected in 68% of cases before implantation and this rate increased to 86% after surgery (P=NS). There were no significant associations (P>0.05) between test results and symptoms. CONCLUSIONS: In the medium term, although older subjects more frequently presented vestibular disorder, cochlear implantation induced little vertigo or balance disorder, sometimes even improving vestibular function. However, vestibular disorders were frequent preoperatively and increased postoperatively. We tested vestibular function on different stimulation frequencies and yet found no correlation between postoperative test results and postoperative vertigo.


Assuntos
Implante Coclear/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Equilíbrio Postural , Transtornos de Sensação/etiologia , Transtornos de Sensação/fisiopatologia , Vertigem/etiologia , Vertigem/fisiopatologia , Vestíbulo do Labirinto/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Canais Semicirculares/fisiopatologia , Potenciais Evocados Miogênicos Vestibulares , Testes de Função Vestibular , Adulto Jovem
16.
Eur Ann Otorhinolaryngol Head Neck Dis ; 135(5): 321-326, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30172621

RESUMO

OBJECTIVES: The main objective was to describe spontaneous nystagmus characteristics during an episode of delayed endolymphatic hydrops (DEH), including an initial vertical upbeating nystagmus in one patient. The secondary objective was to highlight the contribution of chemical labyrinthectomy. METHODS: Episodic vertigo after a prolonged period of time of sensorineural hearing loss (profound or total) in one ear characterized ipsilateral DEH and was associated with the development of hearing loss in the opposite ear in contralateral DEH. RESULTS: Ten patients met the criteria for DEH: 7 ipsilateral and 3 contralateral. Three (all ipsilateral DEH) were examined during a vertigo episode. Two patients had a typical horizontal-torsional nystagmus beating contralaterally to the hearing loss. One patient showed atypic initial vertical upbeating nystagmus with a slight torsional component, which secondarily became horizontal-torsional beating contralaterally to the hearing loss. Four patients had disabling vertigo with unilateral total deafness (ipsilateral DEH), successfully treated by 1-3 transtympanic gentamycin (Gentalline®) injections. CONCLUSION: Nystagmus direction during vertigo episodes varies, and may initially present as vertical upbeating nystagmus, which, to our knowledge, has not been previously reported in DEH or Menière's disease. This nystagmus might reflect an inhibition of the superior semicircular canal (on the hearing-impaired side), suggesting incipient hydrops in this canal. Chemical labyrinthectomy is a simple and effective procedure in unilateral DEH, especially as the patient often suffers from total deafness.


Assuntos
Hidropisia Endolinfática/complicações , Hidropisia Endolinfática/tratamento farmacológico , Nistagmo Patológico/etiologia , Vertigem/etiologia , Adulto , Idoso , Antibacterianos/administração & dosagem , Testes Calóricos , Surdez/complicações , Feminino , Gentamicinas/administração & dosagem , Perda Auditiva Neurossensorial/complicações , Humanos , Injeção Intratimpânica , Masculino , Pessoa de Meia-Idade , Nistagmo Patológico/tratamento farmacológico , Estudos Retrospectivos , Vertigem/tratamento farmacológico , Adulto Jovem
18.
Eur Ann Otorhinolaryngol Head Neck Dis ; 134(3): 177-184, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28461039

RESUMO

The Eustachian (auditory) tube and tympanomastoid cavities form an anatomic and functional whole that cannot easily be divided, and is therefore known as the "tubotympanic system". The system has been the focus of several studies, with complex and sometimes contradictory results, making an overview of its functioning difficult to obtain. The objective of the present article is to review the current state of knowledge, as an indispensable preliminary to understanding tubotympanic system dysfunction, and notably the development of chronic otitis. The system as a whole is covered by mucosa, which provides continuity, although with certain particularities from one area to another, and plays a primordial role. Thus, under physiological conditions, gas diffusion across the tympanomastoid mucosa largely ensures the equilibrium of pressure between the middle ear and outside environment, the tube orifice being very little involved. Under large rapid change in atmospheric pressure, the aeration function of the Eustachian tube comes into play, governed by a reflex mechanism. The system also has other functions that are essential to good middle-ear functioning: protection against nasopharyngeal secretions and pathogens and against certain physiological noises; middle-ear cavity clearance by mucociliary transport of pathogens, partly related to submucosal gland secretion; and immune defense.


Assuntos
Tuba Auditiva/fisiopatologia , Depuração Mucociliar , Otite Média Supurativa/fisiopatologia , Doença Crônica , Orelha Média/fisiopatologia , Humanos , Processo Mastoide/fisiopatologia , Perfuração da Membrana Timpânica/fisiopatologia
19.
Surg Radiol Anat ; 39(8): 871-876, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28405749

RESUMO

BACKGROUND: The anterior commissure (AC) of the human larynx is usually understood as an area of the glottis anteriorly situated between the two vocal folds inserting to the thyroid cartilage (TC). The pattern of spread of AC carcinoma could hypothesize that AC could include other structures of the ventral larynx as developmental anatomy could demonstrate. METHODS: Ten adult larynx specimens from donation program cadavers and 15 selected fetal specimens (from 11 to 34 weeks of amenorrhoea) were studied using microdissection and histological serial sections stained with hematoxylin-eosin and reticuline. RESULTS: In adult specimens, internal perichondrium of the TC was easily detached from the entire lateral lamina but not from an intermediate lamina superiorly marked by the superior thyroid notch. On this median band of TC is inserted the ventral connective tissue of the three levels of the larynx: the ventral part of the vocal folds with the anterior macula flava, the Broyle's epiglottic ligament, and the subglottic part of the conoid ligament. In young fetuses (11-12 weeks), intermediate lamina of TC joined at the glottic level but not at the supraglottic level; in fetuses at 22-25 weeks, a meshwork of bundles of connective fibers inserted to the intermediate lamina of TC. In fetuses at 33-34 weeks, organization is practically identical to adult specimens. CONCLUSION: According to the adult anatomical features and the organogenesis, the AC of the human larynx could be anatomically defined ventrally as being made up of the intermediate lamina of TC beneath the superior thyroid notch and dorsally the ventral insertions of vocal folds with macula flava, supraglottic Broyle's ligament, and subglottic conoid ligament leading to a "developmental" AC definition which could better explain specific spreading of AC carcinoma.


Assuntos
Glote/anatomia & histologia , Cartilagem Tireóidea/anatomia & histologia , Prega Vocal/anatomia & histologia , Adulto , Pontos de Referência Anatômicos , Cadáver , Feminino , Feto/anatomia & histologia , Glote/embriologia , Humanos , Masculino , Cartilagem Tireóidea/embriologia , Prega Vocal/embriologia
20.
Eur Arch Otorhinolaryngol ; 274(4): 1835-1851, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27475796

RESUMO

The objective of this study is to evaluate the safety and efficacy of a new transcutaneous bone-conduction implant (BCI BB) in patients with conductive and mixed hearing loss or with single-sided deafness (SSD), 1 year after surgical implantation. The study design is multicentric prospective, intra-subject measurements. Each subject is his/her own control. The setting is nine university hospitals: 7 French and 2 Belgian. Sixteen subjects with conductive or mixed hearing loss with bone-conduction hearing thresholds under the upper limit of 45 dB HL for each frequency from 500 to 4000 Hz, and 12 subjects with SSD (contralateral hearing within normal range) were enrolled in the study. All subjects were older than 18 years. The intervention is rehabilitative. The main outcome measure is the evaluation of skin safety, audiological measurements, benefit, and satisfaction questionnaires with a 1-year follow up. Skin safety was rated as good or very good. For the mixed or conductive hearing loss groups, the average functional gain (at 500 Hz, 1, 2, 4 kHz) was 26.1 dB HL (SD 13.7), and mean percentage of speech recognition in quiet at 65 dB was 95 % (vs 74 % unaided). In 5/6 SSD subjects, values of SRT in noise were lower with BB. Questionnaires revealed patient benefit and satisfaction. The transcutaneous BCI is very well tolerated at 1-year follow up, improves audiometric thresholds and intelligibility for speech in quiet and noise, and gives satisfaction to both patients with mixed and conductive hearing loss and patients with SSD.


Assuntos
Condução Óssea , Perda Auditiva Condutiva/cirurgia , Satisfação do Paciente , Próteses e Implantes , Adulto , Audiometria , Feminino , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Percepção da Fala , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA