Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Heart Lung Transplant ; 43(2): 251-260, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769887

RESUMO

PURPOSE: The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study reports on clinical HM3 parameters collected with a noninvasive HM3 monitoring system (HM3 Snoopy) during echocardiographic speed ramp tests and Valsalva maneuvers. METHODS: In this prospective, single-center study, the HM3 data communication between the controller and pump was recorded with a novel data acquisition system. Twelve pump parameters sampled every second (1 Hz) and clinical assessments (echocardiography, electrocardiogram (ECG), and blood pressure measurement) during speed ramp tests were analyzed using Pearson's correlation (r, median [IQR]). The cause for the occurrence of pulsatility index (PI)-events during ramp speed tests and valsalva maneuvers was investigated. RESULTS: In 24 patients (age: 58.9 ± 8.8 years, body mass index: 28.1 ± 5.1 kg/m2, female: 20.8%), 35 speed ramp tests were performed with speed changes in the range of ±1000 rpm from a baseline speed of 5443 ± 244 rpm. Eight HM3 pump parameters from estimated flow, motor current, and LVAD speed together with blood pressure showed positive collinearities (r = 0.9 [0.1]). Negative collinearities were observed for pump flow pulsatility, pulsatility index, rotor noise, and left ventricular diameters (r = -0.8 [0.1]), whereas rotor displacement and heartrate showed absence of collinearities (r = -0.1 [0.08]). CONCLUSIONS: In this study, the HM3 Snoopy was successfully used to acquire more parameters from the HM3 at a higher sampling rate. Analysis of HM3 per-second data provide additional clinical diagnostic information on heart-pump interactions and cause of PI-events.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Manobra de Valsalva , Ecocardiografia , Coração Auxiliar/efeitos adversos
2.
ASAIO J ; 70(2): 107-115, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37831817

RESUMO

Effective treatment of heart failure with preserved ejection fraction (HFpEF) remains an unmet medical need. Although left atrial decompression using mechanical circulatory support devices was previously suggested, the heterogeneous HFpEF population and the lack of tailored devices have prevented the translation into clinical practice. This study aimed to evaluate the feasibility of left atrial decompression in HFpEF patients with a HeartMate 3 (HM3, Abbott Inc, Chicago, USA) in silico and in vitro . Anatomic compatibility of the HM3 pump was assessed by virtual device implantation into the left atrium through the left atrial appendage (LAA) and left atrial posterior wall (LAPW) of 10 HFpEF patients. Further, the efficacy of left atrial decompression was investigated experimentally in a hybrid mock loop, replicating the hemodynamics of an HFpEF phenotype at rest and exercise conditions. Virtual implantation without substantial intersection with surrounding tissues was accomplished through the LAA in 90% and 100% through the LAPW. Hemodynamic analysis in resting conditions demonstrated normalization of left atrial pressures without backflow at a pump speed of around 5400 rpm, whereas a range of 6400-7400 rpm was required during exercise. Therefore, left atrial decompression with the HM3 may be feasible in terms of anatomic compatibility and hemodynamic efficacy.


Assuntos
Apêndice Atrial , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/terapia , Volume Sistólico , Átrios do Coração/cirurgia , Hemodinâmica , Descompressão , Função Ventricular Esquerda
3.
Artigo em Inglês | MEDLINE | ID: mdl-38014822

RESUMO

We present the implant method and the postoperative management for an Impella 5.5 device via the right subclavian artery in a 72-year-old patient with severe left ventricular dysfunction upon weaning from cardiopulmonary bypass during a cardiac surgery procedure.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Disfunção Ventricular Esquerda , Humanos , Idoso , Disfunção Ventricular Esquerda/cirurgia , Artéria Subclávia , Ponte Cardiopulmonar , Resultado do Tratamento
4.
ASAIO J ; 69(11): 1016-1024, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37902686

RESUMO

Several device designs for cavopulmonary mechanical circulatory support (MCS) are under investigation, however, challenged by the Fontan population's heterogeneity in size, cardiovascular and thoracic anatomy. This study aimed to preclinically assess the anatomical compliance of proposed device designs in silico. Representative double- and single-outlet cavopulmonary assist device (CPAD) designs were virtually implanted into CT imaging data of 10 patients previously palliated with total cavopulmonary connection (TCPC) for functionally univentricular hearts. Anatomical device compatibility was characterized concerning pump proximity to cardiovascular, respiratory and thoracic structures, as well as pump in- and outflow graft configuration. In 10 Fontan patients with a median age of 10.4 years (interquartile range [IQR] 5.0-15.3 years) and a median body surface area of 1.09 m2 (IQR 0.76-1.28 m2), implantation of a double-outlet CPAD was feasible in 1 patient (10%). In all other, adverse device intersection with the trachea and (neo-)aorta, or posterior pulmonary artery outflow graft kinking were observed. A single-outlet design permitted enhanced device mobilization adapting to individual anatomical conditions, resulting in device fit in nine of 10 patients (90%). Despite vast anatomical variations among single ventricle patients, a single-outlet device design may provide intracorporeal cavopulmonary MCS to a broad spectrum of failing Fontan patients.


Assuntos
Aorta , Artéria Pulmonar , Humanos , Pré-Escolar , Criança , Adolescente , Superfície Corporal , Cooperação do Paciente , Pacientes
5.
Artigo em Inglês | MEDLINE | ID: mdl-37706499

RESUMO

We report the surgical repair of a penetrating aortic ulcer in the distal ascending aorta close to the brachiocephalic trunk, by supracoronary ascending aortic and hemiarch replacement via a full sternotomy. The procedure is performed under moderate hypothermia with bilateral antegrade cerebral perfusion.


Assuntos
Úlcera Aterosclerótica Penetrante , Humanos , Perfusão , Reimplante , Aorta/cirurgia , Circulação Cerebrovascular
6.
ASAIO J ; 69(7): 673-680, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36943696

RESUMO

Both single- and double-outflow cavopulmonary assist devices (CPADs) were recently proposed for the Fontan population, whereas single-outflow configurations were evaluated in large animal trials and double-outflow concepts are lacking an equivalent in vivo assessment. The aim of this study was to test the hemodynamic properties of a double-outflow CPAD device in an acute sheep model. The two inflow cannulae of a CPAD were anastomosed to the caval veins. Outflow graft connection was performed via end-to-side anastomosis to the right (RPA) and main pulmonary artery (MPA). Speed ramp protocols were conducted, and hemodynamic effects were monitored in terms of caval flows, cardiac output (CO), central venous pressure (CVP), pulmonary artery pressure (PAP), and left atrial pressure (LAP). Six experiments were conducted (53.35 ± 5.1 kg). In three experiments, the animal model was established, the CPAD was examined, and restoration of biventricular equivalency in terms of venous return was achieved. Venous pressures (CVP) declined linearly with increasing pump speed (r > 0.879), whereas caval flow (r > 0.973), CO (r > 0.993), PAP (r > 0.973), and LAP (r > 0.408) increased. Despite the considerable complexity of the sheep model caused by the sheep pulmonary arterial anatomy that requires substantial graft bending, the CPAD was evaluated in three acute experiments and showed the potential to completely substitute a subpulmonary ventricle.


Assuntos
Técnica de Fontan , Coração Auxiliar , Animais , Ovinos , Estudos de Viabilidade , Artéria Pulmonar/cirurgia , Hemodinâmica , Modelos Animais
7.
J Heart Lung Transplant ; 41(10): 1533-1536, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35933294

RESUMO

BACKGROUND AND AIM: The Berlin Heart EXCOR system has been developed for mechanical circulatory support (MCS) of pediatric patients with terminal heart failure. A recently introduced iteration of the system (EXCOR Venous Cannula, Berlin Heart GmbH, Berlin, Germany) is dedicated to support patients with univentricular physiologies by facilitating implantation of the EXCOR device into the Fontan pathway. CASE PRESENTATION: We report the worldwide first successful implantation of the EXCOR Venous Cannula in a biventricular support concept for a 12-year-old boy (140 cm, 42.7 kg, body surface area 1.29 m2, Pedimacs Level 2) with severe systemic ventricle dysfunction and failing Fontan circulation. Surgery comprised of standard Berlin Heart EXCOR implantation to support the failing ventricle (12 mm apex / staged 12/9 mm arterial cannula / 50 ml ventricle). Cannulation for subpulmonary EXCOR support was achieved by performing a total cavopulmonary connection takedown with subsequent anastomosis of a staged 12/9 mm outflow cannula to the pulmonary artery and implantation of a 14/18 mm EXCOR Venous Cannula as subpulmonary inflow graft, which was connected to the superior vena cava and Fontan tunnel using GORE-TEX grafts. In the postoperative course, cardiac output and central venous pressures rapidly improved with hepatic and renal functions restoring to age- and condition-specific norm values. CONCLUSION: The Berlin Heart EXCOR Venous Cannula is the first system for standardized mechanical support of Fontan circulatory failure. In our patient, subpulmonary support restoring a biventricular circulation combined with systemic MCS normalized hemodynamics and reversed end-organ dysfunction.


Assuntos
Técnica de Fontan , Coração Auxiliar , Cânula , Cateterismo , Criança , Humanos , Masculino , Politetrafluoretileno , Veia Cava Superior
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA