Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 10(4): e0123031, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25856094

RESUMO

BACKGROUND: The benefits of a decreased slice thickness and/or in-plane voxel size in carotid MRI for atherosclerotic plaque component quantification accuracy and biomechanical peak cap stress analysis have not yet been investigated in detail because of practical limitations. METHODS: In order to provide a methodology that allows such an investigation in detail, numerical simulations of a T1-weighted, contrast-enhanced, 2D MRI sequence were employed. Both the slice thickness (2 mm, 1 mm, and 0.5 mm) and the in plane acquired voxel size (0.62x0.62 mm2 and 0.31x0.31 mm2) were varied. This virtual MRI approach was applied to 8 histology-based 3D patient carotid atherosclerotic plaque models. RESULTS: A decreased slice thickness did not result in major improvements in lumen, vessel wall, and lipid-rich necrotic core size measurements. At 0.62x0.62 mm2 in-plane, only a 0.5 mm slice thickness resulted in improved minimum fibrous cap thickness measurements (a 2-3 fold reduction in measurement error) and only marginally improved peak cap stress computations. Acquiring voxels of 0.31x0.31 mm2 in-plane, however, led to either similar or significantly larger improvements in plaque component quantification and computed peak cap stress. CONCLUSIONS: This study provides evidence that for currently-used 2D carotid MRI protocols, a decreased slice thickness might not be more beneficial for plaque measurement accuracy than a decreased in-plane voxel size. The MRI simulations performed indicate that not a reduced slice thickness (i.e. more isotropic imaging), but the acquisition of anisotropic voxels with a relatively smaller in-plane voxel size could improve carotid plaque quantification and computed peak cap stress accuracy.


Assuntos
Estenose das Carótidas/diagnóstico , Imageamento por Ressonância Magnética/estatística & dados numéricos , Modelos Cardiovasculares , Placa Aterosclerótica/diagnóstico , Anisotropia , Artérias Carótidas/metabolismo , Artérias Carótidas/patologia , Estenose das Carótidas/metabolismo , Estenose das Carótidas/patologia , Simulação por Computador , Humanos , Lipídeos/química , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patologia
2.
Quant Imaging Med Surg ; 4(4): 216-24, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25202656

RESUMO

Carotid magnetic resonance imaging (MRI) is used to noninvasively assess atherosclerotic plaque fibrous cap (FC) status, which is closely related to ischemic stroke. Acquiring anisotropic voxels improves in-plane visualization, however, an oblique scan plane orientation could then obscure a FC (i.e., contrast below the noise level) and thus impair a reliable status assessment. To quantify this, we performed single-slice numerical simulations of a clinical 3.0T, 2D T1-weighted, black-blood, contrast-enhanced pulse sequence with various voxel dimensions: in-plane voxel size of 0.62 mm × 0.62 mm and 0.31 mm × 0.31 mm, slice thickness of 1, 2, and 3 mm. Idealized plaque models (FC thickness of 0.5, 1, and 1.5 mm) were imaged at various scan plane angles (0°-40° in steps of 10°), and the FC contrast was quantified. We found that when imaging thin FCs with anisotropic voxels, the FC contrast decreased when the scan plane orientation angle increased. However, a reduced in-plane voxel size at the cost of an increased slice thickness often led to enhanced FC contrast even in the presence of scan plane orientation angles of up to 40°. It can be concluded that while isotropic-voxel imaging eliminates the issue of scan plane obliqueness, it comes at the cost of reduced FC contrast, thus likely decreasing the reliability of FC status assessment in carotid MRI. If scan plane orientation obliquity at the slice of interest is moderate (<40°) or otherwise diminished through careful scan planning, voxel anisotropy could increase FC contrast and, in effect, increase the reliability of FC status assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA