Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
AJNR Am J Neuroradiol ; 41(2): 219-223, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31857330

RESUMO

BACKGROUND AND PURPOSE: The newly developed ultra-high-resolution CT is equipped with a 0.25-mm detector, which has one-half the conventional section thickness, one-half the in-plane detector element width, and one-half the reconstructed pixel width compared with conventional-detector CT. Thus, the ultra-high-resolution CT scanner should provide better image quality for microvasculature than the conventional-detector CT scanners. This study aimed to determine whether ultra-high-resolution CT produces superior-quality images of the lenticulostriate arteries compared with conventional-detector CT. MATERIALS AND METHODS: From February 2017 to June 2017, thirteen patients with aneurysms (4 men, 9 women; mean age, 61.2 years) who underwent head CTA with both ultra-high-resolution CT and conventional-detector CT were enrolled. Two board-certified radiologists determined the number of all lenticulostriate arteries on the CTA coronal images of the MCA M1 segment reconstructed from 512 matrixes on conventional-detector CT and 1024 matrixes on ultra-high-resolution CT. RESULTS: There were statistically more lenticulostriate arteries identified on ultra-high-resolution CT (average, 2.85 ± 0.83; 95% CI, 2.509-3.183) than on conventional-detector CT (average, 2.17 ± 0.76; 95% CI, 1.866-2.480) (P = .009) in 16 of the total 26 MCA M1 segments. CONCLUSIONS: Improvements in lenticulostriate artery visualization were the result of the combined package of the ultra-high-resolution CT scanner plus the ultra-high-resolution scanning protocol, which includes higher radiation doses with lower than the national diagnostic reference levels and stronger adaptive iterative dose-reduction processing. This package for ultra-high-resolution CT is a simple, noninvasive, and easily accessible method to evaluate microvasculature such as the lenticulostriate arteries.


Assuntos
Artérias/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia/métodos , Estudos Retrospectivos
2.
J Oral Rehabil ; 42(9): 670-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25892610

RESUMO

Although oropharyngeal and laryngeal structures are essential for swallowing, the three-dimensional (3D) anatomy is not well understood, due in part to limitations of available measuring techniques. This study uses 3D images acquired by 320-row area detector computed tomography ('320-ADCT'), to measure the pharynx and larynx and to investigate the effects of age, gender and height. Fifty-four healthy volunteers (30 male, 24 female, 23-77 years) underwent one single-phase volume scan (0.35 s) with 320-ADCT during resting tidal breathing. Six measurements of the pharynx and two of larynx were performed. Bivariate statistical methods were used to analyse the effects of gender, age and height on these measurements. Length and volume were significantly larger for men than for women for every measurement (P < 0.05) and increased with height (P < 0.05). Multiple regression analysis was performed to understand the interactions of gender, height and age. Gender, height and age each had significant effects on certain values. The volume of the larynx and hypopharynx was significantly affected by height and age. The length of pharynx was associated with gender and age. Length of the vocal folds and distance from the valleculae to the vocal folds were significantly affected by gender (P < 0.05). These results suggest that age, gender and height have independent and interacting effects on the morphology of the pharynx and larynx. Three-dimensional imaging and morphometrics using 320-ADCT are powerful tools for efficiently and reliably observing and measuring the pharynx and larynx.


Assuntos
Envelhecimento , Estatura , Deglutição/fisiologia , Laringe/anatomia & histologia , Tomografia Computadorizada Multidetectores , Faringe/anatomia & histologia , Caracteres Sexuais , Adulto , Idoso , Epiglote/anatomia & histologia , Feminino , Glote/anatomia & histologia , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Laringe/diagnóstico por imagem , Laringe/fisiologia , Masculino , Pessoa de Meia-Idade , Faringe/diagnóstico por imagem , Faringe/fisiologia , Valores de Referência
3.
Clin Neuroradiol ; 24(2): 145-50, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23913018

RESUMO

PURPOSE: Many epidemiological studies on unruptured cerebral aneurysms have reported that the larger the aneurysm, the higher the risk of rupture. However, many ruptured aneurysms are not large. Electrocardiography (ECG)-gated 3D-computed tomography angiography (4D-CTA) was used to detect pulsation in unruptured cerebral aneurysms. The differences in the clinical course of patients in whom pulsation was or was not detected were then evaluated. METHODS: Forty-two patients with 62 unruptured cystiform cerebral aneurysms who underwent 4D-CTA and follow-up 3D-CTA more than 120 days later were studied. The tube voltage, tube current, and rotation speed were 120 kV, 270 mA, and 0.35 s/rot., respectively. ECG-gated reconstruction was performed, with the cardiac cycle divided into 20 phases. Patients with heart rates higher than 80 bpm were excluded, so 37 patients with 56 aneurysms were analyzed. RESULTS: Pulsation was detected in 20 of the 56 unruptured aneurysms. Of these 20 aneurysms, 6 showed a change in shape at the time of follow-up. Of the 36 aneurysms in which pulsation was not detected, 2 showed a change in shape at follow-up. There was no significant difference in the follow-up interval between the two groups. The aneurysms in which pulsation was detected were significantly more likely to show a change in shape (P = 0.04), with a higher odds ratio of 7.286. CONCLUSION: Unruptured aneurysms in which pulsation was detected by 4D-CTA were more likely to show a change in shape at follow-up, suggesting that 4D-CTA may be useful for identifying aneurysms with a higher risk of rupture.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Cerebral/métodos , Tomografia Computadorizada Quadridimensional/métodos , Frequência Cardíaca , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Fluxo Pulsátil , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Prognóstico , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade
4.
Neuroradiol J ; 24(1): 48-58, 2011 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-24059571

RESUMO

The objectives of the study were to quantitatively assess whole-brain CT Perfusion (CTP) data using an automatic region of interest (ROI) analysis program in order to distinguish between the degree of ischemia in the ischemic core and that in the penumbra and to assess the relationship between expansion of the area of infarction. The subjects were 20 patients with acute cerebral infarction. Whole-brain CTP was performed for all subjects using a 320-row area detector CT scanner. The penumbra* is defined as the region in which the CBV value is 2 mL/100 g or more and the ischemic core* is defined as the region in which the CBV value is less than 2 mL/100 g. The quantitative values of CTP parameters were automatically measured using the automatic ROIs analysis program. The Mann-Whitney U test was applied to differentiate between the ischemic core* and the penumbra*. The reduction in perfusion pressure in the penumbra* was smaller in the group with expansion of the area of infarction than in the group without expansion of the area of infarction. The difference in the median values between the penumbra* and the ischemic core* was larger in the group with expansion of the area of infarction than the group without expansion of the area of infarction. It is considered that the quantitative analysis method using whole-brain CTP may be useful for more accurately distinguishing between the ischemic core and the penumbra and for evaluating the risk of expansion of the ischemic core into the penumbra.

5.
Inflamm Res ; 57(2): 84-91, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18288458

RESUMO

OBJECTIVE: Angiotensin II (Ang II) receptor blockers have been reported to contribute to cytoprotective effects in various organs. However, the role of renin-angiotensin system (RAS) in modulation of the inflammatory bowel disease (IBD) remains unclear. In this study we assessed the role of angiotensin II type 1a (AT1a) receptor on the outcome of dextran sulfate sodium (DSS)-induced acute colitis by employing AT1a receptor deficient mice. MATERIALS AND METHODS: The acute colitis was induced in wild type (WT) and AT1a receptor deficient mice by giving orally 3% DSS in drinking water for 7 days. RESULTS: Induction of DSS colitis resulted in up-regulation of Ang II and AT1a receptor in the colonic mucosa of WT mice. In parallel, loss of body weight, an increase in disease activity index (DAI), and the shortening of colon were found in DSS-challenged WT mice. In addition, an increase in thiobarbituric acid (TBA)-reactive substances and myeloperoxidase (MPO) activity, along with the up-regulation of tumor necrosis factor (TNF)-alpha were detected in the colonic mucosa of DSS-challenged WT mice. The endpoints mentioned above were significantly ameliorated in DSS-challenged AT1a receptor deficient mice. CONCLUSIONS: RAS is involved in the pathophysiology of DSS-induced colitis and AT1a receptor may be a novel therapeutic target for the treatment of IBD.


Assuntos
Colite/induzido quimicamente , Sulfato de Dextrana/farmacologia , Receptor Tipo 1 de Angiotensina/genética , Receptor Tipo 1 de Angiotensina/fisiologia , Angiotensina II/metabolismo , Animais , Peso Corporal , Colo/patologia , Inflamação , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Peroxidase/metabolismo , Sistema Renina-Angiotensina , Fator de Necrose Tumoral alfa/metabolismo
7.
Int J Mol Med ; 19(2): 335-40, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17203209

RESUMO

Interaction between proteases and protease-activated receptor (PAR) 2 has been proposed to mediate inflammatory and immune response in the gastrointestinal tract. Recently, increase in interleukin (IL)-8 in the esophageal mucosa has been associated with the pathogenesis of esophagitis induced by reflux of gastric acids, bile acids or trypsin. The aims of the present study were to determine PAR2 expression in normal human esophageal epithelial cells (HEEC) and to evaluate the mediation of IL-8 production by trypsin-PAR2 interaction in HEEC. Reverse transcription polymerase chain reaction (RT-PCR) and Western blot analysis revealed that PAR2 mRNA and protein were constitutively expressed in HEEC without upregulation by the stimulation with tumor necrosis factor alpha or trypsin. IL-8 was produced in a dose-dependent fashion when cells were stimulated with a PAR2 agonist such as trypsin or SLIGKV-amide. Blocking antibody to PAR2, camostat mesilate (a trypsin inhibitor), p-38 mitogen-activated protein kinase (MAPK) inhibitors or ERK1/2 inhibitors reduced IL-8 production from trypsin-stimulated HEEC. Mutation of the NFkappaB-, AP-1- and NF-IL-6-binding site on the IL-8 gene promoter abrogated the induction of luciferase activities stimulated with trypsin by 100, 80 and 50%, respectively. These results indicate that PAR2 activation in HEEC by trypsin induces NFkappaB- and AP-1-dependent IL-8 production in association with activation of p38 MAPK and ERK1/2, suggesting that esophageal inflammation may be induced by PAR2 activation via reflux of trypsin.


Assuntos
Células Epiteliais/metabolismo , Esôfago/metabolismo , Interleucina-8/biossíntese , Receptor PAR-2/metabolismo , Anticorpos/imunologia , Linhagem Celular , Genes Reporter/genética , Humanos , Proteínas Quinases Ativadas por Mitógeno/antagonistas & inibidores , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Inibidores de Proteínas Quinases/farmacologia , Receptor PAR-2/genética , Receptor PAR-2/imunologia , Tripsina/metabolismo
8.
Interv Neuroradiol ; 12(Suppl 1): 49-52, 2006 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-20569601

RESUMO

SUMMARY: Intra-aneurysmal flow dynamics is analyzed qualitatively and quantitatively with numerical simulation technique, and presented for the future clinical application in embolizing cerebral aneurysms. From the volumetric data obtained by three-dimensional computed tomographic angiography, patient-specific vessel models were created for 16 middle cerebral artery aneurysms. Intraaneurysmal flow dynamics was visualized and analyzed qualitatively, and the geometrical parameters of vessels and aneurysms that affect the intra- aneurysmal flow dynamics were determined quantitatively by correlation analysis. The flow velocity was delayed in the aneurysm cavity, especially at its tip where the rupture usually occurs. The intra-aneurysmal flow dynamics was considerably influenced by the geometrical parameters that are related to the width of the neck and the branching angle of larger branch artery. The intra-aneurysmal flow dynamics is complex, and the numerical flow simulations with patient-specific vascular models seems effective in understanding the flow dynamics and planning the endovascular treatment of cerebral aneurysms.

9.
Int J Hyperthermia ; 21(7): 603-14, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16304713

RESUMO

AIM: The aim of the present study was to explore whether heme oxygenase-1 (HO-1) is involved in the hyperthermia-provided protection of the small intestine from ischemia/reperfusion injury in rats. METHODS: Intestinal damage was induced in male Sprague-Dawley rats by clamping both the superior mesenteric artery and the celiac trunk for 30 min, followed by reperfusion. Whole-body hyperthermia was induced in anesthetized rats by placement in a temperature-controlled water bath. Whole-body hyperthermia to a core temperature of 42-43 degrees C for 15 min was followed by passive cooling. We started the hyperthermic treatment 6 h before the vascular clamping. The severity of the mucosal injury was evaluated by several biochemical markers and histological findings. Hyperthermia-induced heat-shock proteins were detected by Western blotting. We also investigated the effect of zinc protoporphyrin IX (an HO-1 inhibitor) on the protective effect of hyperthermia. RESULTS: The rats, which were killed after ischemia/reperfusion, had severe intestinal inflammation. Hyperthermia significantly induced the production of Hsp70 and HO-1 in intestinal mucosa and significantly reduced ischemia/reperfusion-induced mucosal injury. The combination of zinc protoporphyrin IX with hyperthermia extinguished the protective effects of hyperthermia on ischemia/reperfusion injury. CONCLUSION: Hyperthermia protects against ischemia/reperfusion injury in rat small intestine through the expression of heat-shock proteins, especially HO-1.


Assuntos
Heme Oxigenase (Desciclizante)/fisiologia , Hipertermia Induzida , Traumatismo por Reperfusão/prevenção & controle , Animais , Quimiocinas CXC/análise , Indução Enzimática , Proteínas de Choque Térmico HSP70/biossíntese , Heme Oxigenase (Desciclizante)/biossíntese , Quinase I-kappa B/biossíntese , Peptídeos e Proteínas de Sinalização Intercelular/análise , Mucosa Intestinal/química , Mucosa Intestinal/efeitos dos fármacos , Intestino Delgado/citologia , Intestino Delgado/efeitos dos fármacos , Masculino , Peroxidase/metabolismo , Protoporfirinas/farmacologia , Ratos , Ratos Sprague-Dawley , Substâncias Reativas com Ácido Tiobarbitúrico/análise
10.
Inflamm Res ; 53(9): 462-8, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15550999

RESUMO

OBJECTIVE: Over-expression of matrix metalloproteinases (MMPs) can accelerate tissue destruction and disrupt subsequent tissue repair. A dextran sulfate sodium (DSS) colitis model was established to examine the effects of MMP inhibition, by an orally active MMP inhibitor ONO-4847, on colonic inflammation. MATERIALS AND METHODS: Acute colitis was induced in female BALB/c mice by giving 8% DSS orally in drinking water for 7 days. The animals were randomized into groups receiving different concentrations of ONO-4847 or vehicle by oral gavage every day. mRNA levels of 4 MMPs and a tissue inhibitor of MMP (TIMP-1) were measured by RT-PCR in intestinal tissue isolated from mice after DSS administration. Colonic mucosal injury and inflammation were evaluated clinically, biochemically, and histologically. The clinical disease activity index (DAI), including body weight loss, stool consistency, and blood in feces, was examined. Moreover, mucosal tumor necrosis factor (TNF)-alpha and interferon (IFN)-gamma were determined by immunoassay. RESULTS: The intestinal expression of MMP-3, -7, 9, and -12 and TIMP-1 mRNA was upregulated after DSS administration. Shortening of the colon was significantly reversed by ONO-4847 at a dose of 30 mg/kg. DAI in DSS-treated mice was significantly lower in the ONO-4847-treated mice compared with the control mice. Histological study also showed a reduced infiltration of inflammatory cells, especially neutrophils, and reducedmucosal cell disruption in ONO-4847-treated mice compared with the control mice. The increases in tissue-associated myeloperoxidase activity and thiobarbituric acid-reactive substances after DSS administration were both significantly inhibited by co-administration with ONO-4847. ONO-4847 also inhibited increases in the mucosal TNF-alpha and IFN-gamma content after DSS administration. CONCLUSION: Improvements in DSS colitis in response to ONO-4847 suggest that activation of MMPs contributes to the initiation/amplification of colonic inflammatory injury by mechanisms including oxidative damage as well as enhancement of inflammatory cytokine release.


Assuntos
Colite/induzido quimicamente , Administração Oral , Animais , Colite/tratamento farmacológico , Colite/patologia , Colite/fisiopatologia , Colo/patologia , Sulfato de Dextrana/farmacologia , Inibidores Enzimáticos/administração & dosagem , Inibidores Enzimáticos/farmacologia , Inibidores Enzimáticos/uso terapêutico , Feminino , Inibidores de Metaloproteinases de Matriz , Metaloproteinases da Matriz/genética , Metaloproteinases da Matriz/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Éteres Fenílicos/administração & dosagem , Éteres Fenílicos/farmacologia , Éteres Fenílicos/uso terapêutico , Índice de Gravidade de Doença , Inibidor Tecidual de Metaloproteinase-1/metabolismo
11.
Interv Neuroradiol ; 10 Suppl 2: 69-78, 2004 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-20587253

RESUMO

SUMMARY: Vascular recanalization by the vascular reconstruction method can dramatically improve ischemic symptoms in patients with acute cerebral ischemia. However, this treatment method is frequently associated with haemorrhagic complications. The indications for this therapeutic approach have been described in a number of studies in the literature. The present paper discusses the possibility of assessing the prognosis of ischemic areas using perfusion CT (PCT) by comparing the results obtained before and after thrombolytic therapy. Twenty-six patients underwent vascular reconstruction at our hospital between July 2002 and March 2004. Of these patients, six who underwent PCT before treatment and showed adequate recanalization following vascular reconstruction were included in the present study. PCT images were obtained using the first-pass bolus-tracking method with a 16-row multislice helical CT scanner. Areas of cerebral ischemia were evaluated by CT before and after vascular reconstruction. A region of interest was placed in the area showing low density in CT images before vascular reconstruction. The mean average CBF (mL/min/100 g), CBV (mL/100 g), and MTT (s) values were calculated in areas with and without cerebral infarction after vascular reconstruction. The %CBF, % CBV, and %MTT values relative to the normal side were evaluated with reference to the time until recanalization. Transarterial vascular reconstruction resulted in full recanalization in four patients and partial recanalization in two. The mean time from onset to recanalization was 284.7 +/- 63.27 minutes and was not longer than six hours in any patient. The patient prognosis results in terms of GOS were GR in two patients, MD in three patients, and SD in one patient. Based on comparison of the time after examination to recanalization, the %CBF showed a significant positive correlation in the salvaged area (Y = 47.321 + 2.491 x %CBF:R(2) = 0.792, p < 0.05). A significant correlation was not observed in %CBV, but %MTT showed a significant negative correlation (Y = 269.45 - 0.356 x %MTT:R(2) = 0.794, p < 0.05). The %CBF and %MTT results obtained by PCT performed before transarterial vascular reconstruction suggest that it may be possible to estimate the time before vascular reconstruction and the relationship with prognosis. These findings are expected to help ensure the appropriate application of vascular reconstruction and to provide useful information for developing optimal therapeutic protocols, thus reducing complications. In addition, because the results are based on the time after examination, the appropriate therapeutic approach can be determined even when the time of onset of ischemia is uncertain.

13.
Acta Neurochir (Wien) ; 144(7): 715-22, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12181705

RESUMO

BACKGROUND AND OBJECTIVE: The aim of this study was to demonstrate the utility of volume rendered multi-slice helical three-dimensional CT angiography in patients with cerebral aneurysm when compared with single slice CT angiography and formal digital subtraction angiography. METHODS: A prototype Toshiba Aquilon multi-slice CT scanner was employed with the following scan conditions: voltage 135 kV; current 300 mA; slice thickness 0.8 mm; scan speed 0.75 sec/cycle; couch speed 1 mm/sec; range 50 mm from foramen magnum; scan pitch 3; three dimensional images were reconstructed using multiple image projections and integral volume rendering algorithms on a Xlink/Xtension workstation. 80 cases of multi-slice CTA for cerebral aneurysm carried out at Fujita University from January 1999 to January 2001 were reviewed. RESULTS: The advantages of multi-slice imaging are illustrated with representative cases of cerebral aneurysm - good demonstration of three dimensional anatomy, appreciation of perforators down to 1 mm in size, delineation of the vessels around the aneurysm complex, relationship between the aneurysm and skull base, information on calcification, thrombus and blebs in the wall and eleven routine views for perusal. CONCLUSION: Multi-slice CTA is a significant improvement over single slice CTA for cerebral aneurysms. It is our experience the superior and precise images produced by multi-slice technology displays anatomical information not readily available from standard DSA. Multislice 3D-CTA is relatively non-invasive and provides better and adequate detail for surgical planning. The basis of multi-slice CT angiography is described. Multi slice CTA is changing the way cerebral aneurysms are being managed nowadays. New advances in the technology of multi-slice CTA resulting in increased image resolution are outlined.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Aneurisma Intracraniano/cirurgia , Sensibilidade e Especificidade
14.
Planta ; 213(5): 764-9, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11678281

RESUMO

Far-red light (FR) inhibition of seed germination of tomato (Solanum lycopersicum L.) was studied with the phytochrome (phy)-hypersensitive mutants, hp-1w, hp-1w,fri1, a phyA-deficient double mutant, and hp-1w,tri1, a phyB1-deficient double mutant. Seeds of all mutants germinated readily in the dark at 25 degrees C, and the germination was retarded by a single 100-s FR pulse given 1-3 h after sowing. The effect of an FR pulse was red-light reversible in all mutants used. After 24 h where a single FR pulse was no longer effective, prolonged FR exposure or hourly FR pulses suppressed germination in hp-1w and hp-1w,tri1, whereas in hp-1w,fri1 the suppressive effect of FR was almost absent. The effect of the prolonged FR was greater than that of the hourly 3-min FR pulses having equal photon fluence, and was fluencerate dependent. Thus we conclude that the germination inhibition by FR in tomato seed consists of a low-fluence response and a high irradiance response (HIR); the latter is controlled by phyA, but not phyB1. This is the first indication of phyA being involved in the HIR of seed germination inhibition.


Assuntos
Germinação/efeitos da radiação , Células Fotorreceptoras , Fitocromo/metabolismo , Proteínas de Plantas , Solanum lycopersicum/crescimento & desenvolvimento , Fatores de Transcrição , Apoproteínas/genética , Apoproteínas/metabolismo , Luz , Solanum lycopersicum/genética , Solanum lycopersicum/efeitos da radiação , Mutação , Complexo de Proteínas do Centro de Reação Fotossintética/genética , Complexo de Proteínas do Centro de Reação Fotossintética/metabolismo , Fitocromo/genética , Fitocromo A , Fitocromo B , Plantas Geneticamente Modificadas , Sementes/genética , Sementes/crescimento & desenvolvimento , Sementes/efeitos da radiação , Fatores de Tempo
15.
Acta Neurochir (Wien) ; 143(3): 245-50, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11460912

RESUMO

After introducing of Helical scanning CT (HCT) and 3D-CTA (three-dimensional CT angiography), various improvements to these methods have been made every year to achieve better imaging quality. The current resolution permits visualisation of the internal structure of tumors, although as yet insufficiently clearly. We suggest that these improvements can be more efficient than conventional cerebral aneurysms angiography. In this study, we compared HCT and 3D-CTA with conventional cerebral angiography in patients with cerebral aneurysms at our facility. We also examined whether 3D-CTA has the possibility of independent clinical application and can surpass conventional DSA in diagnostic efficacy. In this paper, we found this information insufficient in clipping operations using 3D-CTA only when 1) It was difficult to distinguish a crooked infundibular dilation from an aneurysm, 2) Imaging threshold influenced the measured value of the vascular diameter and 3) It was also difficult to confirm whether the peripheral vessels adhere to the aneurysm. In conclusion, from the result of the comparison between 3D-CTA and DSA in this study, it was concluded that 3D-CTA is a reliable alternative method to conventional angiography in the diagnosis of anterior circulation and most aneurysms of regular size. In such cases it may be possible to obtain the same quality of preoperative information, but it is less invasive.


Assuntos
Angiografia Digital , Angiografia Cerebral , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
16.
Ann Nucl Med ; 15(5): 465-70, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11758956

RESUMO

PURPOSE: Because of the recent innovative growth in computer technology, digital imaging, and the Internet, we can take advantage of these facilities for education and clinical work in nuclear medicine. We developed a tele-nuclear medicine conference system with electronic mail (e-mail) on the Internet. METHODS: Twenty-one physicians (20 radiologists, 1 neurologist), 6 technologists and 2 medical students in six university hospitals (Japan 5, Canada 1), 5 local hospitals in Japan participated in this project. We used digital still cameras (330 k pixels) equipped with a floppy disk drive and 10 x optical zoom to digitize images with JPEG compression (640 x 480 matrix). The images were attached to e-mail messages (containing a brief description of each case). The mail was sent simultaneously to all members on the mailing list. Scintigram and SPECT images as well as other radiological images were sent by e-mail. Reply mails about each case were sent to all members via the mailing list. RESULTS: During a period of 6 months, 18 cases (tumor/infection: 7, bone: 6, cardiovascular: 1, neurology; 3, endocrine: 1) with 144 e-mails (average 5.6/case) were submitted to the conference. The average period of discussion was 15.6 days. The number of attached images was 1 to 9 (average, 4.2/e-mails). JPEG compression rate was 1/10 to 1/20. The quality of the images was good enough for discussion. Some cases required additional images for further discussion. CONCLUSION: Our tele-nuclear medicine conference with an electronic mailing list and digital camera was simple and low-cost. The conference system was useful for education and clinical work.


Assuntos
Internet , Imageamento por Ressonância Magnética , Medicina Nuclear/métodos , Consulta Remota/métodos , Tomografia Computadorizada de Emissão , Canadá , Congressos como Assunto/organização & administração , Humanos , Internet/economia , Internet/estatística & dados numéricos , Japão
17.
Neurol Res ; 22(7): 692-8, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11091974

RESUMO

The mechanisms of cerebral aneurysm recurrence and enlargement were investigated in 11 patients: two with dissecting aneurysms, six with fully grown aneurysms after neck clipping, one with enlarged aneurysm after dome clipping, and two with enlarged aneurysm due to recanalization after GDC coil embolization. We concluded that it is fundamentally important to ensure complete attachment of the internal elastic lamina around the aneurysm neck by precise neck clipping and effective embolization, with accurate positioning of remaining internal elastic lamina.


Assuntos
Endotélio Vascular/cirurgia , Aneurisma Intracraniano/cirurgia , Endotélio Vascular/patologia , Humanos , Aneurisma Intracraniano/patologia , Aneurisma Intracraniano/prevenção & controle , Masculino , Pessoa de Meia-Idade , Prevenção Secundária , Procedimentos Cirúrgicos Vasculares/instrumentação
18.
Acta Haematol ; 104(2-3): 106-9, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11154984

RESUMO

A 55-year-old woman came to our hospital because of cutaneous sclerosis of the limbs in September 1996, and was diagnosed with scleroderma based on a skin biopsy. In August 1997, the cutaneous sclerosis became progressive (hemoglobin level, 4.3 g/dl; platelet count, 7 x 10(9)/l). The laboratory results were positive for the direct Coombs test, bone marrow aspiration showed a dry tap, and the bone marrow biopsy showed marked fatty marrow. Indium-111 bone marrow scintigraphy showed a markedly decreasing uptake. These findings indicated bone marrow hypoplasia associated with hemolytic anemia. After prednisolone therapy (60 mg) was initiated, the direct Coombs test became negative but the blood cell count did not increase. Then, 300 mg of cyclosporin was initiated and anemia and thrombocytopenia improved. The cyclosporin dosage was gradually decreased and the patient's hematological condition was good, although the cutaneous sclerosis changed only a little. This is a rare and interesting case of a patient with scleroderma associated with bone marrow insufficiency and hemolysis who responded well to cyclosporin.


Assuntos
Anemia Hemolítica/tratamento farmacológico , Ciclosporina/uso terapêutico , Púrpura Trombocitopênica/tratamento farmacológico , Escleroderma Sistêmico/sangue , Escleroderma Sistêmico/tratamento farmacológico , Anemia Hemolítica/sangue , Anemia Hemolítica/complicações , Feminino , Humanos , Pessoa de Meia-Idade , Púrpura Trombocitopênica/sangue , Púrpura Trombocitopênica/complicações , Escleroderma Sistêmico/etiologia
19.
Surg Neurol ; 52(2): 113-21; discussion 121-2, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10447276

RESUMO

BACKGROUND: 3D CT angiography (3D-CTA) is a noninvasive imaging modality for cerebral aneurysms. 3D-CTA is helpful in the evaluation of the configuration of the aneurysm, the surrounding vessels, and the inside of the aneurysm dome. Clinical application of this technique in complicated large cerebral aneurysms showed that with 3D-CT endoscopic imaging, anatomical details of cerebral aneurysms such as the orifice of the aneurysm, intraluminal thrombus, and calcification of the wall could be clearly demonstrated. Using the 3D-imaging method with helical CT, virtual views of various surgical approaches can be compared preoperatively. This information was found to be very useful for determining difficult aneurysms for coil embolization or direct surgery including complicated and broad-based aneurysms. METHODS: Helical CT scanners (TOSHIBA X-vigor) are used for intracranial vascular lesions. At present, nearly stereoscopic images at a pixel size of 0.35 x 0.35 x 0.4 mm are obtained by reconstruction under the following conditions: slice thickness, 0.8 mm; couch top speed, 1.0 mm/ sec.; 130 kV; 220 mA; visual field, 18 cm in diameter (11 cm after extension); pitch, 0.4 mm; and opposed beam interpolation. RESULTS AND CLINICAL APPLICATION: By virtual vascular 3D-CT endoscopy, the lumen of the cerebral aneurysm is displayed by the surface rendering method. Its clinical applications include 1) Demonstration of three-dimensional aneurysm morphology, including the dome and the neck region; 2) Preoperative simulation; 3) Confirmation of parent blood vessels flowing into and out of aneurysms and visualization of aneurysmal lumen calcification. Coronal and sagittal sections can demonstrate whether the branches arise from the aneurysm or aneurysmal neck. The limitation of 3D-CTA is in delineating perforating arteries that are less than 1.2 mm in diameter. The problem with virtual vascular 3D-CT endoscopic images is that endoscopic findings in the vascular wall are incomplete because of the partial volume effect and pulsation of the aneurysm and vascular wall. CONCLUSIONS: Helical Scanning-CT (HES-CT) is an excellent noninvasive diagnostic modality for cerebral aneurysm detection. 3D-CT angiography has distinct advantages in evaluating aneurysms and selecting the most appropriate therapeutic modality.


Assuntos
Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
20.
Radiology ; 211(2): 497-506, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10228534

RESUMO

PURPOSE: To assess the diagnostic accuracy of three-dimensional (3D) computed tomographic (CT) angiography for intracranial aneurysms. MATERIALS AND METHODS: The 3D CT angiograms obtained in 49 patients with or without intracranial aneurysms were evaluated by four blinded observers. Results were compared with findings at conventional angiography or surgery. A volume-rendering method was used, and 13 images obtained in different directions were reviewed in each study. The diameter of aneurysms was divided into four sizes: large, greater than 13 mm; medium, 5-12 mm; small, 3-4 mm; and very small, less than 3 mm. Results were also evaluated by means of receiver operating characteristic analysis. RESULTS: At conventional angiography, 47 aneurysms, including 14 less than 3 mm, were depicted in 35 patients. The mean sensitivity of CT angiography for very small aneurysms was 64%; small, 83%; medium, 95%; and large, 100%. Some very small aneurysms that were not depicted at conventional angiography were depicted at CT angiography, and one was proved at surgery. CONCLUSION: CT angiography has good sensitivity for depiction of intracranial aneurysms 3 mm or larger and relatively good sensitivity for aneurysms less than 3 mm. CT angiography may be a noninvasive technique for detection of asymptomatic unruptured or ruptured aneurysms.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Humanos , Aneurisma Intracraniano/cirurgia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA