Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Front Chem ; 9: 756745, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34966718

RESUMO

During the summer of 2019, cases of lung injury associated with vaping emerged in North America, including among individuals who reported exclusive use of nicotine vaping liquids. Once vitamin E acetate was identified as a potential causative agent a quantitative method based on a simple sample dilution, separation by gas chromatography and analysis by triple quadrupole mass spectrometry (GC MSMS) was developed. Method detection limit (MDL) and limit of quantification (LOQ) were determined at 0.159 µg/mL and 0.505 µg/mL, respectively. The analysis was performed on a subset of 203 commercially sourced nicotine containing vaping liquids of various flavour profile and nicotine range (nicotine free-59 mg/mL) from an internal inventory. The target analyte, Vitamin E Acetate, was not detected in any samples analyzed, as expected, given the reported detection in literature and high association of the chemical with cannabis and not nicotine containing vaping products.

2.
J AOAC Int ; 104(2): 368-383, 2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-33283860

RESUMO

Extensive use of synthetic musk compounds (SMs) in numerous consumer and personal care products has resulted in direct human exposures via dermal absorption, inhalation of contaminated dust and volatilized fragrances, and oral ingestion of contaminated foods and liquids. SMs and their metabolites are lipophilic, hence commonly detected in various biological matrices such as blood, breast milk, and adipose tissue. Appropriate analytical techniques are needed to detect and quantify SMs in biological matrices to assess their potential effects on human health. Different methods to process and analyze SMs in biological matrices, including sample-pretreatment, solvent extraction, cleanup, and instrumental analysis, are presented in this review. The concentration levels of selected musk compounds in biological samples from different countries/regions are summarized. Finally, research gaps and questions pertaining to the analysis of SMs are identified and suggestions made for future research studies.


Assuntos
Cosméticos , Perfumes , Ácidos Graxos Monoinsaturados , Feminino , Humanos , Leite Humano/química , Perfumes/análise , Receptores Proteína Tirosina Quinases , Receptores Colinérgicos
3.
J AOAC Int ; 103(6): 1461-1468, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33247738

RESUMO

BACKGROUND: Synthetic musk compounds are widely used as fragrances in many consumer products; however, information on human exposure and health effects is limited. Also, analytical methods for their quantification in biological matrices are limited. OBJECTIVE: In this study, an integrated method was developed and validated for the analysis of selected synthetic musk compounds in human serum. METHOD: The method is based on liquid-liquid extraction (LLE), sample clean-up by solid-phase extraction (SPE), and separation and detection by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). RESULTS: The method demonstrated good recoveries (86-105%) and high sensitivity, with low method detection limits (MDLs) ranging from 0.04 to 0.17 µg/L. The method was applied to the analysis of 10 synthetic musk compounds in 40 serum samples collected from Canadian women aged 20-44 years (20 individual samples collected in 2014 and 20 pooled samples collected in 2006). The most commonly detected compound was Galaxolide (HHCB), with median concentrations of 0.59 µg/L in samples collected in 2006, and 0.34 µg/L for samples collected in 2014. Musk ketone (MK) was not detected in any of the samples collected in 2006, but was detected in 60% of the samples collected in 2014 with a median concentration of 0.29 µg/L. Tonalide (AHTN) was detected in only one sample above its MDL (0.12 µg/L). CONCLUSIONS: This is the first study in Canada to report levels of synthetic musks in human. The data generated from this study has been used in risk screening assessment by Environment and Climate Change Canada and Health Canada.


Assuntos
Ácidos Graxos Monoinsaturados , Espectrometria de Massas em Tandem , Poluentes Químicos da Água , Adulto , Canadá , Ácidos Graxos Monoinsaturados/sangue , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Receptores Proteína Tirosina Quinases , Receptores Colinérgicos , Poluentes Químicos da Água/análise , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA