Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
2.
Hematology Am Soc Hematol Educ Program ; 2023(1): 305-310, 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38066852

RESUMO

In the United States, more than 2 000 000 apheresis platelet units are collected annually from volunteer donors. Platelet donors in the United States and elsewhere are permitted to donate up to 24 times per year. Recently, frequent apheresis platelet donation has been associated with severe T-cell lymphopenia. Several frequent platelet donors have been found to have peripheral blood CD4+ T-cell counts below 200 cells/µL, the threshold for AIDS in HIV-positive individuals. Independent risk factors for plateletpheresis-associated lymphopenia include lifetime donations, age, and donations on the Trima Accel instrument (Terumo BCT), which uses a leukoreduction system (LRS) chamber to trap white blood cells. Less often, severe lymphopenia can occur in donors collected on the Fenwal Amicus instrument (Fresenius Kabi), which has no LRS. For Trima Accel donors, lymphopenia can be partially mitigated by performing a plasma rinseback step at the end of collection. To date, there is no definitive evidence that plateletpheresis-associated lymphopenia is harmful. In a study of frequent platelet donors with lymphopenia who were administered COVID-19 messenger RNA vaccines, immune responses were normal. The homeostatic mechanisms responsible for maintaining a normal peripheral blood T-cell count remain obscure, as do the causal mechanisms underlying plateletpheresis-associated lymphopenia.


Assuntos
Doenças da Medula Óssea , Linfopenia , Humanos , Doadores de Sangue , Plaquetas , Linfopenia/etiologia , Linfócitos T , Voluntários
3.
Transfusion ; 63(11): 2072-2082, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37818894

RESUMO

BACKGROUND: Severe T-cell lymphopenia of uncertain clinical significance has been observed in frequent apheresis platelet donors. Two commonly used plateletpheresis instruments are the Trima Accel, which uses a leukoreduction system (LRS) chamber to trap leukocytes and the Fenwal Amicus, which does not use an LRS chamber. STUDY DESIGN AND METHODS: We performed an international, multicenter, observational study comparing T-cell populations in frequent platelet donors collected exclusively using the Trima instrument (n = 131) or the Amicus instrument (n = 77). Age- and sex-matched whole blood donors (n = 126) served as controls. RESULTS: CD4+ T-cell counts <200 cells/µL were found in 9.9% of frequent Trima (LRS+) platelet donors, 4.4% of frequent Amicus (LRS-) platelet donors, and 0 whole blood donors (p < .0001). CD4+ T-cell counts <200 cells/µL were only seen in platelet donors with ≥200 lifetime donations. In multivariable analysis, age, lifetime donations, and instrument (Trima vs. Amicus) were independent risk factors for lymphopenia. In 40 Trima platelet donors, a plasma rinseback procedure was routinely performed following platelet collections. No Trima platelet donors receiving plasma rinseback had a CD4+ T-cell count <200 cells/µL versus 13/91 Trima platelet donors not receiving plasma rinseback (p = .01). DISCUSSION: Recurrent bulk lymphocyte removal appears to contribute to the development of T-cell lymphopenia in frequent, long-term platelet donors. Lymphopenia is more common when an LRS chamber is used during platelet collection but can occur without an LRS chamber. Blood centers using LRS chambers can mitigate donor lymphopenia by performing plasma rinseback.


Assuntos
Plaquetas , Linfopenia , Humanos , Plaquetoferese/métodos , Doadores de Sangue , Linfopenia/etiologia , Leucócitos
4.
JAMA ; 329(23): 2088-2089, 2023 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-37338884

RESUMO

This study establishes a Duffy null phenotype­specific absolute neutrophil count reference range to optimize care and improve health equity.


Assuntos
Contagem de Leucócitos , Neutrófilos , Humanos , Valores de Referência , Sistema do Grupo Sanguíneo Duffy
5.
Blood ; 142(2): 202-209, 2023 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-37172200

RESUMO

Frequent plateletpheresis is associated with severe lymphopenia of uncertain clinical significance. We assessed the functional impact of frequent platelet donations and associated lymphopenia on the response to neoantigens. We conducted a prospective study of 102 platelet donors (HIV uninfected) who were naive to meningococcal vaccination recruited at Brigham and Women's Hospital. One dose of quadrivalent meningococcal conjugate vaccine was administered. Seroresponse was defined as a fourfold increase of serum bactericidal antibody titers and seroprotection was defined as postvaccination titers of ≥1:8, for each of the 4 vaccine antigens (A, C, W, and Y). Mean age of participants was 61 years, 69% were male, and medial number of platelet donations in prior year was 14 (interquartile range, 4-20). Frequent platelet donors had a low CD4 count (14% with ≤200/µL and 34% with ≤350/µL). Seroresponse rates varied from 68% for serogroup Y to 86% for serogroup A and were higher for participants with baseline titers of <1:8. Postvaccination seroprotection rates varied from 76% for serogroup Y to 96% for serogroup A. After adjustments for age, sex, and frequent donations, lower total lymphocyte or lower CD4 counts were not associated with lower responses. These data suggest no impairment by plateletpheresis-associated lymphopenia on response to these neoantigens. This trial was registered at www.clinicaltrials.gov as #NCT04224311.


Assuntos
Linfopenia , Infecções Meningocócicas , Vacinas Meningocócicas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anticorpos Antibacterianos , Infecções Meningocócicas/prevenção & controle , Estudos Prospectivos , Vacinas Conjugadas
6.
Blood Adv ; 7(16): 4621-4630, 2023 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-37146262

RESUMO

Examination of red blood cell (RBC) morphology in peripheral blood smears can help diagnose hematologic diseases, even in resource-limited settings, but this analysis remains subjective and semiquantitative with low throughput. Prior attempts to develop automated tools have been hampered by their poor reproducibility and limited clinical validation. Here, we present a novel, open-source machine-learning approach (denoted as RBC-diff) to quantify abnormal RBCs in peripheral smear images and generate an RBC morphology differential. RBC-diff cell counts showed high accuracy for single-cell classification (mean AUC, 0.93) and quantitation across smears (mean R2, 0.76 compared with experts, interexperts R2, 0.75). RBC-diff counts were concordant with the clinical morphology grading for 300 000+ images and recovered the expected pathophysiologic signals in diverse clinical cohorts. Criteria using RBC-diff counts distinguished thrombotic thrombocytopenic purpura and hemolytic uremic syndrome from other thrombotic microangiopathies, providing greater specificity than clinical morphology grading (72% vs 41%; P < .001) while maintaining high sensitivity (94% to 100%). Elevated RBC-diff schistocyte counts were associated with increased 6-month all-cause mortality in a cohort of 58 950 inpatients (9.5% mortality for schist. >1%, vs 4.7% for schist; <0.5%; P < .001) after controlling for comorbidities, demographics, clinical morphology grading, and blood count indices. RBC-diff also enabled the estimation of single-cell volume-morphology distributions, providing insight into the influence of morphology on routine blood count measures. Our codebase and expert-annotated images are included here to spur further advancement. These results illustrate that computer vision can enable rapid and accurate quantitation of RBC morphology, which may provide value in both clinical and research contexts.


Assuntos
Eritrócitos Anormais , Doenças Hematológicas , Processamento de Imagem Assistida por Computador , Humanos , Eritrócitos Anormais/citologia , Doenças Hematológicas/diagnóstico por imagem , Doenças Hematológicas/patologia , Prognóstico , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Aprendizado de Máquina , Forma Celular
7.
Am J Transplant ; 23(4): 512-519, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36732087

RESUMO

ABO compatibility is important for kidney transplantation, with longer waitlist times for blood group B kidney transplant candidates. However, kidneys from non-A1 (eg, A2) subtype donors, which express less A antigen, can be safely transplanted into group B recipients. ABO subtyping is routinely performed using anti-A1 lectin, but DNA-based genotyping is also possible. Here, we compare lectin and genotyping testing. Lectin and genotype subtyping was performed on 554 group A deceased donor samples at 2 transplant laboratories. The findings were supported by 2 additional data sets of 210 group A living kidney donors and 124 samples with unclear lectin testing sent to a reference laboratory. In deceased donors, genotyping found 65% more A2 donors than lectin testing, most with weak lectin reactivity, a finding supported in living donors and samples sent for reference testing. DNA sequencing and flow cytometry showed that the discordances were because of several factors, including transfusion, small variability in A antigen levels, and rare ABO∗A2.06 and ABO∗A2.16 sequences. Although lectin testing is the current standard for transplantation subtyping, genotyping is accurate and could increase A2 kidney transplant opportunities for group B candidates, a difference that should reduce group B wait times and improve transplant equity.


Assuntos
Transplante de Rim , Humanos , Genótipo , Incompatibilidade de Grupos Sanguíneos , Doadores de Tecidos , Doadores Vivos , Sistema ABO de Grupos Sanguíneos/genética , Isoanticorpos
8.
Blood Adv ; 7(3): 317-320, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-35994632

RESUMO

Many people of African ancestry have lower absolute neutrophil counts (ANCs) without increased risk for infection. This is associated with the Duffy-null phenotype (nonexpression of the Duffy antigen on red blood cells), which is commonly found in those of African descent. Currently, there are no studies that compare the ANC of individuals with Duffy-null phenotype to those with Duffy non-null phenotypes within a self-identified Black population. The aim of this study was to assess the impact of Duffy status on ANCs based on complete blood counts with differential and Duffy testing in a healthy population of self-identified Black individuals at a single primary care center. This study found that 66.7% (80 of 120) of Black individuals have the Duffy-null phenotype and that there is a significant difference in ANCs between Duffy-null and Duffy non-null individuals (median, 2820 cells per µL vs 5005 cells per µL; P < .001). Additionally, 19 of 80 (23.8%) Duffy-null individuals had an ANC of <2000 cells per µL compared with no (0) Duffy non-null individuals. The Duffy-null phenotype is clinically insignificant; however, inappropriate reference ranges can propagate systemic racism. Therefore, we advocate for the development of Duffy-null-specific ANC reference ranges as well as replacing the term benign ethnic neutropenia with Duffy-nullassociated neutrophil count.


Assuntos
Neutropenia , Neutrófilos , Humanos , Negro ou Afro-Americano/genética , Contagem de Leucócitos , População Negra/genética , Neutropenia/genética
9.
Transfusion ; 62(8): 1559-1570, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35808950

RESUMO

BACKGROUND: At the start of the coronavirus disease 2019 (COVID-19) pandemic, widespread blood shortages were anticipated. We sought to determine how hospital blood supply and blood utilization were affected by the first wave of COVID-19. STUDY DESIGN AND METHODS: Weekly red blood cell (RBC) and platelet (PLT) inventory, transfusion, and outdate data were collected from 13 institutions in the United States, Brazil, Canada, and Denmark from March 1st to December 31st of 2020 and 2019. Data from the sites were aligned based on each site's local first peak of COVID-19 cases, and data from 2020 (pandemic year) were compared with data from the corresponding period in 2019 (pre-pandemic baseline). RESULTS: RBC inventories were 3% lower in 2020 than in 2019 (680 vs. 704, p < .001) and 5% fewer RBCs were transfused per week compared to 2019 (477 vs. 501, p < .001). However, during the first COVID-19 peak, RBC and PLT inventories were higher than normal, as reflected by deviation from par, days on hand, and percent outdated. At this time, 16% fewer inpatient beds were occupied, and 43% fewer surgeries were performed compared to 2019 (p < .001). In contrast to 2019 when there was no correlation, there was, in 2020, significant negative correlations between RBC and PLT days on hand and both percentage occupancy of inpatient beds and percentage of surgeries performed. CONCLUSION: During the COVID-19 pandemic in 2020, RBC and PLT inventories remained adequate. During the first wave of cases, significant decreases in patient care activities were associated with excess RBC and PLT supplies and increased product outdating.


Assuntos
COVID-19 , Pandemias , COVID-19/epidemiologia , Transfusão de Eritrócitos , Eritrócitos , Hospitais , Humanos , Estados Unidos
10.
Transfusion ; 62(8): 1511-1518, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35866570

RESUMO

BACKGROUND: Anti-CD38 antibodies such as daratumumab (DARA) are critical therapies for multiple myeloma and other diseases. Unfortunately, anti-CD38 antibodies cause panreactivity in indirect antiglobulin tests (IATs), complicating blood compatibility testing. The anti-CD38 interference is most often mitigated by treating reagent red blood cells (RBCs) with dithiothreitol (DTT). However, when using the DTT method, not all RBC antibody specificities can be detected (e.g., anti-K), and the DTT method is impractical for some transfusion services. We evaluated the ability of a new anti-idiotype antibody to neutralize DARA in vitro and eliminate the anti-CD38 interference. STUDY DESIGN AND METHODS: A recombinant monoclonal rabbit anti-DARA idiotype antibody ("anti-DARA") was generated. The ratio of anti-DARA required to neutralize DARA in spiked samples was evaluated in IATs performed in gel. IATs performed in tube were used to demonstrate that anti-DARA allows alloantibody detection in the presence of DARA. Plasma samples from 29 patients receiving DARA were treated with a fixed quantity of anti-DARA (120 µg) before performing antibody detection tests (screens) in tube. RESULTS: Anti-DARA used at or above a 1:1 ratio with DARA eliminated the DARA interference with IATs. Anti-DARA allowed detection of both alloanti-E and alloanti-K in the presence of DARA. In 27/29 (93.1%) clinical samples, 120 µg anti-DARA was sufficient to neutralize the DARA in 100 µl patient plasma. DISCUSSION: An anti-DARA:DARA ratio as low as 1:1 is sufficient to neutralize DARA in solution. A fixed amount of anti-DARA eliminates the anti-CD38 interference in most patient samples.


Assuntos
Anticorpos Monoclonais , Mieloma Múltiplo , Animais , Teste de Coombs , Ditiotreitol/uso terapêutico , Mieloma Múltiplo/tratamento farmacológico , Coelhos
11.
Microbiol Spectr ; 10(2): e0021122, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35311584

RESUMO

The use of anti-spike (S) serologic assays as surrogate measurements of SARS-CoV-2 vaccine induced immunity will be an important clinical and epidemiological tool. The characteristics of a commercially available anti-S antibody assay (Roche Elecsys anti-SARS-CoV-2 S) were evaluated in a cohort of vaccine recipients. Levels were correlated with pseudotype neutralizing antibodies (NAb) across SARS-CoV-2 variants. We recruited adults receiving a two-dose series of mRNA-1273 or BNT162b2 and collected serum at scheduled intervals up to 8 months post-first vaccination. Anti-S and NAb levels were measured, and correlation was evaluated by (i) vaccine type and (ii) SARS-CoV-2 variant (wild-type, Alpha, Beta, Gamma, and three constructs Day 146*, Day 152*, and RBM-2). Forty-six mRNA vaccine recipients were enrolled. mRNA-1273 vaccine recipients had higher peak anti-S and NAb levels compared with BNT162b2 (P < 0.001 for anti-S levels; P < 0.05 for NAb levels). When anti-S and NAb levels were compared, there was good correlation (all r values ≥ 0.85) in both BNT162b2 and mRNA-1273 vaccine recipients across all evaluated variants; however, these correlations were nonlinear in nature. Lower correlation was identified between anti-S and NAb for the Beta variant (r = 0.88) compared with the wild-type (WT) strain (r = 0.94). Finally, the degree of neutralizing activity at any given anti-S level was lower for each variant compared with that of the WT strain, (P < 0.001). Although the Roche anti-S assay correlates well with NAb levels, this association is affected by vaccine type and SARS-CoV-2 variant. These variables must be considered when interpreting anti-S levels. IMPORTANCE We evaluated anti-spike antibody concentrations in healthy mRNA vaccinated individuals and compared these concentrations to values obtained from pseudotype neutralization assays targeting SARS-CoV-2 variants of concern to determine how well anti-spike antibodies correlate with neutralizing titers, which have been used as a marker of immunity from COVID-19 infection. We found high peak anti-spike concentrations in these individuals, with significantly higher levels seen in mRNA-1273 vaccine recipients. When we compared anti-spike and pseudotype neuralization titers, we identified good correlation; however, this correlation was affected by both vaccine type and variant, illustrating the difficulty of applying a "one size fits all" approach to anti-spike result interpretation. Our results support CDC recommendations to discourage anti-spike antibody testing to assess for immunity after vaccination and cautions providers in their interpretations of these results as a surrogate of protection in COVID-vaccinated individuals.


Assuntos
COVID-19 , SARS-CoV-2 , Vacina de mRNA-1273 contra 2019-nCoV , Adulto , Anticorpos Neutralizantes , Anticorpos Antivirais , Vacina BNT162 , COVID-19/diagnóstico , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , SARS-CoV-2/genética , Vacinas Sintéticas , Vacinas de mRNA
12.
Transfusion ; 62(1): 1, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35023157
14.
Am J Ther ; 29(4): e385-e393, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31833874

RESUMO

BACKGROUND: The optimal monitoring strategy for anticoagulation management in extracorporeal membrane oxygenation (ECMO) remains a clinical controversy. The Extracorporeal Life Support Organization Anticoagulation Guidelines suggest that multiple anticoagulation assays may be needed but do not specify a preferred management strategy. STUDY QUESTION: In adult ECMO patients, which anticoagulation assays demonstrate the highest correlation with unfractionated heparin (UFH) dose requirements? STUDY DESIGN: We performed a retrospective chart review of adult patients cannulated to ECMO between February 2013 and July 2015. MEASURES AND OUTCOMES: The primary outcome was the correlation between activated clotting time (ACT), activated partial thromboplastin time (aPTT), and anti-Xa and UFH dose. Secondary outcomes included correlations between anticoagulation assays. Correlations were calculated for the entire cohort, with subgroup analysis of venoarterial and venovenous ECMO patients. RESULTS: Forty-eight patients were included in the analysis, 26 initially cannulated to venoarterial ECMO and 22 to veno-venous ECMO. The median duration of ECMO therapy was 7 days. Mean UFH requirements were 1149 units/h or 15.3 units/kg/h. Total UFH dose was most correlated with anti-Xa levels (r = 0.467), whereas weight-based heparin dose was most correlated with aPTT (0.405). For correlations between anticoagulation assays, anti-Xa and aPTT were more highly correlated with each other (r = 0.633) compared with ACT. CONCLUSIONS: In adult patients requiring ECMO, anti-Xa and aPTT monitoring were correlated more closely with UFH dosing than ACT.


Assuntos
Oxigenação por Membrana Extracorpórea , Heparina , Adulto , Anticoagulantes , Heparina de Baixo Peso Molecular , Humanos , Tempo de Tromboplastina Parcial , Estudos Retrospectivos
15.
Transfusion ; 62(1): 44-50, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34726274

RESUMO

BACKGROUND: A wrong blood in tube (WBIT) error signifies a blood sample that does not match the patient identified on the sample label. WBIT errors can result in ABO mistransfusions. STUDY DESIGN AND METHODS: In this international, multicenter, descriptive study, healthcare facilities provided detailed information on WBIT errors occurring from 1/1/2019 to 12/31/2020. Factors contributing to WBIT errors were classified as protocol violations, knowledge gaps, and slips/lapses. RESULTS: 331 WBIT errors were compiled from 36 centers in 11 countries. WBIT errors were most frequently detected through pretransfusion sample testing (191, 58%), with 38 (20%) detected by a second ("check") sample. WBIT errors were divided almost evenly between intended patient drawn/wrong label applied (166, 50%) and wrong patient drawn/intended label applied (158, 48%). Information on contributing factors was available for 260 WBIT errors; most involved a combination of protocol violations and slips/lapses (139, 53%). The most frequent contributing factor was another patient's sample labels or tubes being available during phlebotomy (61%). Protocol violations were more likely to result in wrong patient being drawn (p = .0007). In 43 WBIT errors, electronic positive patient identification (ePPID) was not used when available or was used incorrectly. CONCLUSIONS: Protocol violations and slips/lapses frequently contribute to WBIT errors. Sample collection processes should be designed to minimize error opportunities; staff should be educated on why protocol compliance is critical for patient safety. Using ePPID does not eliminate all WBIT errors. Institutions using ePPID may elect to require check sample verification as an added safety measure.


Assuntos
Erros Médicos , Segurança do Paciente , Humanos , Pesquisa
16.
Transfusion ; 61(9): 2601-2610, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34268775

RESUMO

BACKGROUND: Wrong blood in tube (WBIT) errors can lead to ABO mistransfusions. It is unknown if WBIT errors are more likely in specific healthcare locations or if specific collection practices influence the commission of WBIT errors. STUDY DESIGN AND METHODS: Data on pretransfusion samples from calendar year 2019 were collected retrospectively by 39 transfusion services in nine countries. We compared the proportion of WBIT errors made in emergency departments (EDs), inpatient wards, and outpatient clinics. RESULTS: In total, 143 WBIT errors were detected among 1,394,862 samples for an unadjusted aggregate WBIT proportion of 1.03/10,000 samples. Using a pooled random effects model, the WBIT proportion was estimated to be significantly higher in EDs (1.23/10,000 samples, 95% CI 0.62-2.43) than inpatient wards (0.71/10,000, 95% CI 0.44-1.14; p < .001) or outpatient clinics (0.24/10,000, 95% CI 0.08-0.65; p < .001) and significantly higher in inpatient wards than outpatient clinics (p = .043). The use of electronic positive patient identification (ePPID) systems was associated with a significantly lower WBIT proportion in the ED (odds ratio, OR: 0.32, 95% CI: 0.11-0.96, p = .041), but not in inpatient wards (OR: 0.45, 95% CI: 0.20-1.01, p = .054) or outpatient clinics (OR: 1.95, 95% CI: 0.39-9.74, p = .415). DISCUSSION: Normalized for the number of samples drawn per location, the WBIT proportion in EDs was 1.7 times higher than inpatient wards and 5.1 times higher than outpatient clinics. EDs represent higher-risk clinical locations for WBIT errors, and electronic positive patient identification (ePPID) may provide a greater impact on safety in EDs relative to other clinical areas.


Assuntos
Coleta de Amostras Sanguíneas , Serviço Hospitalar de Emergência , Erros Médicos , Doadores de Sangue , Coleta de Amostras Sanguíneas/efeitos adversos , Transfusão de Sangue , Estudos Transversais , Humanos , Estudos Retrospectivos , Reação Transfusional/etiologia
18.
Transfusion ; 60(6): 1294-1307, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32473076

RESUMO

BACKGROUND: The MNS blood group system is defined by three homologous genes: GYPA, GYPB, and GYPE. GYPB encodes for glycophorin B (GPB) carrying S/s and the "universal" antigen U. RBCs of approximately 1% of individuals of African ancestry are U- due to absence of GPB. The U- phenotype has long been attributed to a deletion encompassing GYPB exons 2 to 5 and GYPE exon 1 (GYPB*01N). STUDY DESIGN AND METHODS: Samples from two U-individuals underwent Illumina short read whole genome sequencing (WGS) and Nanopore long read WGS. In addition, two existing WGS datasets, MedSeq (n = 110) and 1000 Genomes (1000G, n = 2535), were analyzed for GYPB deletions. Deletions were confirmed by Sanger sequencing. Twenty known U- donor samples were tested by a PCR assay to determine the specific deletion alleles present in African Americans. RESULTS: Two large GYPB deletions in U- samples of African ancestry were identified: a 110 kb deletion extending left of GYPB (DEL_B_LEFT) and a 103 kb deletion extending right (DEL_B_RIGHT). DEL_B_LEFT and DEL_B_RIGHT were the most common GYPB deletions in the 1000 Genomes Project 669 African genomes (allele frequencies 0.04 and 0.02). Seven additional deletions involving GYPB were seen in African, Admixed American, and South Asian samples. No samples analyzed had GYPB*01N. CONCLUSIONS: The U- phenotype in those of African ancestry is primarily associated with two different complete deletions of GYPB (with intact GYPE). Seven additional less common GYPB deletion backgrounds were found. GYPB*01N, long assumed to be the allele commonly encoding U- phenotypes, appears to be rare.


Assuntos
Negro ou Afro-Americano/genética , Éxons , Deleção de Genes , Glicoforinas/genética , Sistema do Grupo Sanguíneo MNSs/genética , Humanos
20.
Transfusion ; 60 Suppl 1: S1, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32134126
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA