Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Neurooncol ; 168(2): 249-257, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38568377

RESUMO

PURPOSE: To investigate the effect of intraoperative magnetic resonance imaging (Io MRI) on overall and progression-free survival (OS and PFS), on the extent of resection (EOR) in patients with glioma, and impact of the radiological diagnosis on the decision to continue the surgery when a residual mass was detected on Io MRI. METHODS: The study comprised 153 glioma patients who received surgical treatment between 2013 and 2023. One-hundred twenty-five of them had Io MRI guidance during surgery. The remainder 28 patients constituted the control group who did not undergo Io MRI. All patients' age at surgery, gender, initial radiological diagnosis, primary tumor localization, EOR, last histopathological diagnosis, and the follow-up periods were recorded. RESULTS: The rate of tumor recurrence in Io MRI cases was significantly lower compared to the cases in the control group (p < .0001). It was decided to continue the operation in 45 Io MRI applied cases. This raised the gross total resection (GTR) rate from 33.6% to 49.6% in the Io MRI group. The frequency of GTR was significantly higher in patients with an initial radiological diagnosis of low grade glioma than those with high grade glioma. The shortest OS was seen in occipital gliomas. CONCLUSION: In this study, the convenience provided by the high-field MRI device was explored and proven both in reducing the tumor burden, increasing the PFS, and providing the surgeon with a maximal resection in the first operation.


Assuntos
Neoplasias Encefálicas , Glioma , Imageamento por Ressonância Magnética , Humanos , Glioma/cirurgia , Glioma/diagnóstico por imagem , Glioma/patologia , Masculino , Feminino , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Estudos Retrospectivos , Adulto Jovem , Procedimentos Neurocirúrgicos/métodos , Seguimentos , Adolescente , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/cirurgia , Recidiva Local de Neoplasia/patologia , Monitorização Intraoperatória/métodos
2.
Turk J Med Sci ; 52(4): 1118-1129, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36326362

RESUMO

BACKGROUND: Cervical instability can be caused by a variety of factors, including trauma, tumors, or infection. The cervical transpedicular screw (CPS) is one of the most modern procedures for treating cervical instability. Despite the fact that numerous innovative techniques for CPS have been proposed, the appropriate screw entry points and screw directions have yet to be thoroughly established. The aim of this study is to determine the screw insertion angles and screw entry point distances based on reference points, pedicle axis lengths, and pedicle axis intersections for each vertebra from cervical (C) C2 to C7 in both right and left by gender and age groups. METHODS: In this study, computed tomography (CT) images of patients who underwent cervical examination for any reason were evaluated retrospectively. A total of 100 patients (59 men and 41 females), ranging in age from 18 to 79 years (mean 43 years), were randomly selected for the study. Patients with a history of cervical pathology or surgery were excluded. CT images turned into 3D reconstructed images and density settings were made so that bone tissue could be best observed using OsiriX software. Pedicle axis length (PAL), pedicle transverse angle (PTA), pedicle sagittal angle (PSA), distance of screw entry point to lateral notch (DLN), distance of screw entry point to inferior articular process (DIAP), and pedicle axis intersections were measured. RESULTS: According to our findings, the optimal entry point should be 2-4 mm medial to the lateral notch and 8-12 mm superior to inferior articular process. PTA ranges between 30 to 45°, while PSA ranges between 11 to 15°. Except for the C2 pedicles, which were slightly shorter, the pedicle axis lengths (PAL) were similar from C3 to C7 in the total group. The intersection of the right and left pedicle axes was determined to be the most in C4 (51.21% in females and 72.88% in males). DISCUSSION: This study has shown that intersections of the pedicle axis must be considered in both genders, especially in C4. Standardizing optimal entry points and trajectories is crucial for improving the CPS technique's safety and effectiveness.


Assuntos
Vértebras Cervicais , Doenças da Coluna Vertebral , Humanos , Feminino , Masculino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Estudos Retrospectivos , Parafusos Ósseos , Doenças da Coluna Vertebral/patologia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA