Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Korean J Anesthesiol ; 77(3): 364-373, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38480982

RESUMO

BACKGROUND: In recent years, the suprainguinal fascia iliaca compartment block (SFICB) has become more common in clinical practice. This assessor-blinded dose-finding study aimed to determine the minimum effective concentration (MEC90, MEC95) of bupivacaine for a single-injection SFICB in patients undergoing arthroscopic anterior cruciate ligament repair. METHODS: This prospective study was conducted at a tertiary hospital (postoperative recovery room and ward). The SFICB was performed as a postsurgical intervention after spinal anesthesia. Seventy patients were allocated using the biased-coin design up-and-down sequential method. The ultrasound-guided SFICB was performed using different bupivacaine concentrations, and standard multimodal analgesia was administered to all patients. Block success was defined as the absence of pain or presence of only tactile sensation during the pinprick test conducted on the anterior and lateral regions of the mid-thigh six hours postoperatively. RESULTS: According to isotonic regression and bootstrap CIs, the MEC90 value of bupivacaine for a successful SFICB was 0.123% (95% CI [0.098, 0.191]) and the MEC95 value was 0.188% (95% CI [0.113, 0.223]). CONCLUSIONS: Our study showed that the MEC90 and MEC95 values for bupivacaine administered via an SFICB for analgesia were 0.123% and 0.188%, respectively. One advantage of using lower concentrations of bupivacaine is the associated reduction in quadriceps weakness.


Assuntos
Anestésicos Locais , Bupivacaína , Fáscia , Bloqueio Nervoso , Dor Pós-Operatória , Ultrassonografia de Intervenção , Humanos , Bupivacaína/administração & dosagem , Estudos Prospectivos , Masculino , Feminino , Anestésicos Locais/administração & dosagem , Ultrassonografia de Intervenção/métodos , Bloqueio Nervoso/métodos , Adulto , Dor Pós-Operatória/prevenção & controle , Fáscia/efeitos dos fármacos , Fáscia/diagnóstico por imagem , Pessoa de Meia-Idade , Relação Dose-Resposta a Droga , Analgesia/métodos , Adulto Jovem , Artroscopia/métodos
2.
Medicina (Kaunas) ; 59(11)2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-38003979

RESUMO

Purpose: The aim of this study was to evaluate the presence of residual instability in the knee after ACL reconstruction through the analysis of MRI findings. Methods: This study included patients who underwent isolated ACL reconstruction between December 2019 and December 2021, and had preoperative and postoperative MRI, clinical scores, and postoperative isokinetic measurements. The anterior tibial translation (ATT) distance, coronal lateral collateral ligament (LCL) sign, and femorotibial rotation (FTR) angle were compared preoperatively and postoperatively. The correlation between the changes in preoperative-postoperative measurements and postoperative measurements with clinical scores and isokinetic measurements was examined. The clinical outcomes were compared based on the presence of a postoperative coronal LCL sign. Inclusion criteria were set as follows: the time between the ACL rupture and surgery being 6 months, availability of preoperative and postoperative clinical scores, and objective determination of muscle strength using isokinetic dynamometer device measurements. Patients with a history of previous knee surgery, additional ligament injuries other than the ACL, evidence of osteoarthritis on direct radiographs, cartilage injuries lower limb deformities, and contralateral knee injuries were excluded from this study. Results: This study included 32 patients. After ACL reconstruction, there were no significant changes in the ATT distance (preoperatively: 6.5 ± 3.9 mm, postoperatively: 5.7 ± 3.2 mm) and FTR angle (preoperatively: 5.4° ± 2.9, postoperatively: 5.2° ± 3.5) compared to the preoperative measurements (p > 0.05). The clinical measurements were compared based on the presence of a postoperative coronal LCL sign (observed in 17 patients, not observed in 15 patients), and no significant differences were found for all parameters (p > 0.05). There were no observed correlations between postoperative FTR angle, postoperative ATT distance, FTR angle change, and ATT distance change values with postoperative clinical scores (p > 0.05). Significant correlations were observed between the high strength ratios generated at an angular velocity of 60° and a parameters FTR angle and ATT distance (p-values: 0.028, 0.019, and r-values: -0.389, -0.413, respectively). Conclusions: Despite undergoing ACL reconstruction, no significant changes were observed in the indirect MRI findings (ATT distance, coronal LCL sign, and FTR angle). These results suggest that postoperative residual tibiofemoral rotation and tibial anterior translation may persist; however, they do not seem to have a direct impact on clinical scores. Furthermore, the increase in tibial translation and rotation could potentially negatively affect the flexion torque compared to the extension torque in movements requiring high torque at low angular velocities.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamentos Laterais do Tornozelo , Humanos , Rotação , Ligamentos Laterais do Tornozelo/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Amplitude de Movimento Articular/fisiologia , Extremidade Inferior , Reconstrução do Ligamento Cruzado Anterior/métodos , Imageamento por Ressonância Magnética , Fenômenos Biomecânicos , Cadáver
3.
Diagnostics (Basel) ; 13(17)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37685325

RESUMO

BACKGROUND AND OBJECTIVE: Anterior cruciate ligament (ACL) injuries are very common among the athletic population. ACL reconstruction (ACLR) performed because of these injuries is one of the procedures performed by orthopedic surgeons using different grafting methods. This study aims to compare the data related to post-operative 6-month isokinetic strength values, strength-related asymmetry rates, time parameters, and joint angle in athletes who underwent ACLR with the Modified All-inside (4ST) technique, on both the healthy knee (HK) and the ACLR-applied sides. MATERIALS AND METHODS: A total of 20 athletes from various sports on whom the 4ST ACLR technique had been applied by the same surgeon were evaluated retrospectively. Lysholm, Tegner, and International Knee Documentation Committee (IKDC) scores of the patients were obtained pre-operative and at 6 months post-operative. Isokinetic knee extension (Ex) and flexion (Flx) strengths on the HK and ACLR sides of the patients were evaluated with a series of four different angular velocities (60, 180, 240, and 300°/s). In addition to peak torque (PT) and hamstring/quadriceps ratio (H/Q) parameters, the findings were also evaluated with additional parameters such as joint angle at peak torque (JAPT), time to peak torque (TPT), reciprocal delay (RD), and endurance ratio (ER). RESULTS: There was a significant improvement in the mean Lysholm, Tegner, and IKDC scores after surgery compared with pre-operative levels (p < 0.05). As for PT values, there were significant differences in favor of the HK in the 60, 180, and 300°/s Ex phases (p < 0.05). In terms of the H/Q and (hamstring/hamstring)/(quadriceps/quadriceps) (HH/QQ) ratios, there were significant differences at 300°/s (p < 0.05). In terms of JAPT, there were significant differences in the 300°/s Ex and 180°/s Flx phases (p < 0.05). In terms of TPT, there were significant differences in the 300°/s Ex phase (p < 0.05). In terms of RD and ER, no significant difference was observed between the HK and ACLR sides at any angular velocity. CONCLUSIONS: Although differences were observed in PT values, particularly in the Ex phase, this did not cause a significant change in H/Q ratios. Similar results were observed for additional parameters such as JAPT, TPT, RD, and ER. The results show that this ACLR technique can be used in athletes in view of strength gain and a return to sports.

4.
J Clin Med ; 12(18)2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37763016

RESUMO

BACKGROUND: Total Knee Arthroplasty (TKA) is one of the most commonly performed orthopedic procedures, and patients complain of severe pain in the postoperative period. The supra-inguinal fascia iliaca block (SIFIB) works as an anteriorly applied lumbar plexus block and is frequently used in hip surgeries. In this study, we evaluated the effect of SIFIB in patients undergoing TKA under spinal anesthesia. METHODS: This study is a prospective, randomized, assessor-blinded feasibility study conducted in a tertiary hospital. Eighty-six patients with ASA I-III were initially enrolled, and after exclusions, 80 patients were randomized into two equal groups (SIFIB and control groups). The standard multimodal analgesia was applied to the control group, while SIFIB was additionally applied to the block group. The study measured the morphine requirement in PCA and pain intensity using Numeric Rating Scores between the two groups. RESULTS: the 24-h cumulative morphine consumption was lower in Group SIFIB. Although there was a decrease in NRS at rest scores in the SIFIB group during some time periods, pain was moderate, and no differences in pain scores were recorded during exercise in all patients. CONCLUSIONS: In patients undergoing TKA under spinal anesthesia, a single shot of SIFIB results in a significant reduction in the amount of morphine consumed in hours. This effect was most likely related to a decrease in pain at rest in the SIFIF group.

5.
J Clin Med ; 12(12)2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37373696

RESUMO

INTRODUCTION: The purpose of this study was to demonstrate that patients undergoing ACL reconstruction with quadrupled semitendinosus suspensory femoral and tibial fixation have comparable results in muscle strength and knee function to those undergoing ACL reconstruction with four-strand semitendinosus-gracilis suspensory femoral fixation and a bioabsorbable tibial interference screw fixation. MATERIALS AND METHODS: Between 2017 and 2019, 64 patients who were operated on by the same surgeon were included. Patients underwent ACL reconstruction technique with quadrupled semitendinosus suspensory femoral and tibial button fixation in Group 1, and patients underwent ACL reconstruction with coupled four-strand semitendinosus-gracilis suspensory femoral fixation and a bioabsorbable tibial interference screw in Group 2. Evaluation of patients was performed with the Lysholm and Tegner activity scale preoperatively and at the 1st and 6th months postoperatively. At the 6-month visit, isokinetic testing of the operated and non-operated limbs was performed in both groups. RESULTS: There was no significant difference in the age, weight, and BMI values of the patients in Groups 1 and 2 (p < 0.05). According to the strength values of the operated sides of the patients in Group 1 and Group 2, there was no significant difference in the angular velocities of 60° s-1, 180° s-1, and 240° s-1 in both extension and flexion phases between the operated sides of Groups 1 and 2 (p < 0.05). CONCLUSIONS: Patients who have ACL reconstruction with quadrupled semitendinosus suspensory femoral and tibial fixation have comparable muscle strength and knee function to those who undergo ACL reconstruction with four-strand semitendinosus-gracilis suspensory femoral fixation and a bioabsorbable tibial interference screw.

6.
Cureus ; 15(2): e34992, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36938192

RESUMO

Purpose The goal of this study was to determine the antibacterial activity of bone cement in polymethyl methacrylate (PMMA) structures with varying amounts of silver nanoparticles (AgNPs) included. Additionally, we aimed to evaluate whether AgNPs affect the biomechanical properties of PMMA cement in our study. Materials and methods Between April 2020 and June 2020, we conducted a series of experiments to demonstrate the antibacterial characteristics by adding silver nanoparticles to PMMA bone cement. PMMA bone cement (Cemex, Tecres Company, Verona, Italy) was used as the base material. Seven different samples were prepared in order to evaluate the amount and presence of AgNPs. Cement samples containing AgNPs and teicoplanin at different concentrations and empty cement (control, without teicoplanin and AgNPs) were placed on Petri plates. The agar diffusion method was used to determine the antibacterial effect (Kirby-Bauer). Results Kirby-Bauer assays demonstrated that AgNPs added to bone cement increased the antimicrobial activity compared to antibiotic-free or only teicoplanin-loaded cement. It was observed that increasing the AgNPs ratio further increased the antimicrobial activity. Conclusion AgNPs in various combinations enhance antimicrobial activity synergistically while maintaining the mechanical strength of bone cement. Increasing the amount of AgNPs results in a significant increase in antimicrobial activity.

7.
J Pers Med ; 13(3)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36983648

RESUMO

BACKGROUND AND OBJECTIVES: Anterior cruciate ligament (ACL) ruptures are common injuries, and ACL reconstruction (ACLR) is among the most common surgical procedures in sports surgery. Our research aims to compare the 6-month post-operative results of the modified all-inside (MAI) ACLR technique, single leg hop tests (SLHT), and Y balance tests applied in different directions on the operated and non-operated sides. MATERIALS AND METHODS: A retrospective cohort of 22 male recreational athletes who underwent MAI ACLR techniques performed by the same surgeon were evaluated. The functional knee strengths of the participants on the operated and non-operated sides were evaluated with five different tests of SLHTs: single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) with hop for distance (MRH). Their dynamic balance was evaluated with the Y balance Test. RESULTS: Compared to pre-operative levels, there was a significant improvement in the mean Lysholm, Tegner, and IKDC scores during the post-operative period (p < 0.05). There was a difference between SH, THD, CHD, MSTH, and MRH on the operated and non-operative sides (p < 0.05). There was no difference between Y balance scores on the operated and non-operative sides, and there were no differences between LSI scores resulting from SLHTs (p > 0.05). There were no significant relationships between YBT (composite scores) and SH, TH, CH, MSTH, and MRH distances in the healthy leg (p > 0.05), but a significant correlation with only CH in the ACL leg (p < 0.05). CONCLUSIONS: Our research shows that sixth-month post-operative SLHT findings were lower on the ACL side compared to the healthy side in patients tested with the MAI ACLR technique. However, when these scores are evaluated in terms of balance, it can be seen that both sides reveal similar findings. The similarity of LSIs in SLHTs applied in different directions, and balance scores of ACL and healthy sides revealed that the MAI technique is also an ACLR technique that can be used in athletes from a functional point of view.

8.
Orthop J Sports Med ; 11(3): 23259671231155153, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36875338

RESUMO

Background: Anterior cruciate ligament reconstruction (ACLR) using the complete tibial tunnel technique and adjustable-loop cortical suspensory fixation is known to leave a "dead space" that holds the loop device in the tibial tunnel. The consequence of the dead space and its effect on graft healing are still uncertain. Purpose: To investigate morphological changes in the tibial tunnel and their effect on graft healing, and to identify factors affecting bone healing in the tibial loop tunnel after ACLR with a quadrupled semitendinosus tendon autograft using adjustable suspensory fixation. Study Design: Case series; Level of evidence, 4. Methods: Included were 48 patients (34 male, 14 female; mean age, 25.2 ± 5.6 years) who underwent ACLR with a quadrupled semitendinosus tendon autograft using adjustable suspensory fixation. To evaluate tibial tunnel morphology, computed tomography was performed at 1 day and 6 months postoperatively. At 1 year postoperatively, graft healing was assessed on magnetic resonance imaging using the graft signal-to-noise quotient (SNQ). Multivariate regression and correlation analyses were performed to determine any associations between volumetric changes in bone healing and operative variables. Results: At 6 months after ACLR, a mean of 63.2% of the tibial loop tunnel was filled by bone. Multivariate regression analysis showed that remnant preservation was significantly associated with the loop tunnel filling rate (P < .001). At 1 year after ACLR, the tibial loop tunnel was almost completely closed (98.5%). There were no correlations between loop tunnel volume and graft integration or graft SNQ. A significant but weak correlation was found between graft tunnel volume and intratunnel graft SNQ (P = .10) as well as integration grade in the tibial tunnel (P = .30). Conclusion: Excellent bone filling in the tibial loop tunnel was seen at 1 year after ACLR. Remnant preservation was significantly associated with the loop tunnel filling rate. A weak correlation was found between graft tunnel volume and intratunnel graft SNQ as well as integration grade in the tibial tunnel.

9.
J Knee Surg ; 36(10): 1069-1076, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35820431

RESUMO

This study compared the clinical outcomes of patients treated with described "modified all-inside" anterior cruciate ligament reconstruction (ACLR) technique with those of patients treated with suspensory femoral fixation and a bioabsorbable tibial interference screw with the ACLR technique. From 2017 to 2019, 98 patients who underwent ACLR surgery by two surgeons using either of the techniques were included in this study. Patients in group 1 were treated with the "modified all-inside" ACLR technique. In this technique, only the semitendinosus tendon was harvested as a four-strand graft and fixed to the tibia and femur with suspensory buttons. Patients in group 2 were treated with suspensory femoral fixation and a bioabsorbable tibial interference screw ACL reconstruction technique. Patients' functional outcomes were evaluated by the Lysholm score, Tegner activity scale, and International Knee Documentation Committee (IKDC) subjective score. Postoperative knee stability of the patients was evaluated using the Lachman test and the pivot-shift test. The mean ages of the patients were 31.1 (16-55) and 28.7 (18-48) years in groups 1 and 2, respectively. The average follow-up durations were 26 (20-30) and 25.9 (22-30) months for both groups. There was no significant difference between the preoperative and postoperative Lysholm's score, Tegner's activity score, and IKDC subjective score in groups 1 and 2. There were no major complications or reruptures in either group. ACLR incorporating the "modified all-inside" ACLR technique obtained significant clinical outcomes compared to ACLR with a suspensory femoral fixation and a bioabsorbable tibial interference screw.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Músculos Isquiossurais , Humanos , Tíbia/cirurgia , Fêmur/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Parafusos Ósseos , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/etiologia
10.
Cureus ; 14(2): e22684, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35242486

RESUMO

Background Scaphoid waist fractures make up 66% of scaphoid fractures and are mostly non-displaced. The purpose of this study was to demonstrate that percutaneous screw fixation is preferable to cast immobilization in the treatment of non-displaced or minimally displaced scaphoid waist fractures. Methodology Between 2017 and 2019, we conducted a retrospective review of patients aged 17-65 years who underwent treatment for acute non-displaced scaphoid waist fractures. In total, 52 patients with scaphoid waist fractures were included in the analysis, 25 of whom underwent percutaneous screw treatment and 27 were treated with a short plaster cast. Patient satisfaction, pain, range of motion, and grip strength were evaluated using the Mayo Modified Wrist Score (MMWS). In addition, the time to return to work/sports, union time, complications, and non-union status were evaluated. Results A total of 52 (35 male, 15 female) patients were enrolled in this study. The average follow-up time was 24.9 months (range, 24-29 months). The mean age was 28.12 years (range, 17-45 months). Group 1 consisted of 25 patients who underwent percutaneous screw fixation, and group 2 consisted of 27 patients who were treated with a short plaster cast. There were significant differences in return to work, return to sports, and union time between the two groups (p < 0.001). The sixth-month MMWS was significantly different between the two groups (p < 0.001), but the first-year MMWS was not significantly different between the two groups (p = 0.864). There were no complications in both groups. Conclusions With percutaneous screw fixation, acute non-displaced or minimally displaced scaphoid waist fractures demonstrated a high rate of union and early return to work/sports.

11.
Cureus ; 14(2): e22173, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35308678

RESUMO

Introduction Implants used in orthopedic surgery can be colonized by bacteria that form biofilm layers complicating treatment. We aimed to determine titanium implants' antibacterial and biofilm-degrading properties when coated with sodium borate (NaB) and calcium borate (CaB) minerals. Methods We analyzed twenty-four different implants. Three implants were not coated, three were coated with only a carrier polymer (alginate), and eighteen were coated with either CaB or NaB at different concentrations. The implants were incubated with Staphylococcus aureus, and then the bacterial colonies were enumerated. Results The highest microbial load was observed on the implant coated with alginate (1000 colony-forming units [CFU]/mL). The implant without coating contained a microbial load of 420 CFU/mL. The microbial loads of the implants coated with 0.75 mg/mL CaB or 0.25, 0.5, and 0.75 mg/mL NaB (100, 200, 0, and 0 CFU/mL, respectively) were lower than that of the implant without coating. No biofilm formation was observed on implant surfaces coated with 0.5 mg/mL NaB, 0.75 mg/mL NaB, or 0.75 mg/mL CaB; biofilm formation was observed on the implant without coating and alginate-coated implants surfaces. Conclusion At high concentrations, borate minerals (NaB and CaB) have a potent antibacterial effect on colonization and biofilm formation on the implant surface. These elements may be used in implant coating in the future because of their potential antibacterial effects.

12.
Medicina (Kaunas) ; 58(3)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35334611

RESUMO

Background and Objectives: Anterior cruciate ligament (ACL) tears are common injuries in the athletic population, and accordingly, ACL reconstruction (ACLR) is among the most common orthopedic surgical procedures performed in sports medicine. This study aims to compare the semitendinosus/gracilis (ST/G) and ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia (MAI) ACLR techniques. We aimed to compare the results of single-leg hop tests (SLHT) applied in different directions and limb symmetry indices (LSI) in athletes with a 6-month post-operative ACLR history. Materials and Methods: A retrospective cohort of 39 athletes from various sports branches who underwent MAI (n = 16) and ST/G (n = 23) ACLR techniques by the same surgeon were evaluated. The knee strength of the participants on the operated and non-operated sides was evaluated with five different SLHTs. The SLHT included the single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) hop for distance (MRH). Results: There was a significant improvement in the mean Lysholm, Tegner, and IKDC scores in the post-operative leg for both techniques (p < 0.05) compared to the pre-operative levels. When there was a difference between the SH of the operative and the non-operative legs in the ST/G technique (p < 0.05), there was no significant difference in the other hop distance for both ST/G and MAI (p > 0.05). There was no difference between the techniques regarding the LSI scores. Conclusions: The fact that our research revealed similar LSI rates of the SLHTs applied in different directions in the ST/G and MAI techniques assumes that the MAI technique can be an ACLR technique which can be functionally used in athletes.


Assuntos
Músculos Isquiossurais , Perna (Membro) , Atletas , Autoenxertos , Fêmur/cirurgia , Humanos , Estudos Retrospectivos , Volta ao Esporte , Tíbia/cirurgia
13.
J Clin Med ; 12(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36614863

RESUMO

Background and Objectives: Anterior cruciate ligament (ACL) injuries are common injuries with a high incidence among people with high physical activity levels. Therefore, ACL reconstruction (ACLR) is one of the most common surgical procedures performed in sports medicine. This study aims to compare the pre- and 6-month post-operative isokinetic knee strengths in healthy (HK) and ACL knees of patients who underwent semitendinous/gracilis (ST/G) ACLR. Materials and Methods: A retrospective cohort of 21 recreational athletes who underwent ST/G ACLR by the same surgeon were evaluated. The pre- and 6-month post-operative isokinetic knee extension (Ex) and flexion (Flx) strengths of the HK and ACLR patients were evaluated in a series consisting of three different angular velocities (60, 180 and 240°/s). Of all the findings, peak torque (PT) and hamstring/quadriceps (H/Q) parameters were evaluated. Results: There was a significant improvement in post-operative Lysholm, Tegner and IKDC scores compared to pre-operative scores (p < 0.05). There were significant differences in pre-operative and post-operative knee Ex and Flx strengths at angular velocities of 60°, 180° and 240°/s in both the ACLR and HK groups (p < 0.001). There was no significance at 240°/s Flx for ACLR (p > 0.05). As for H/Q ratios, there was a significant difference between pre- and post-operative values only at 60°/s angular velocity in both ACLR and HC (p < 0.005). Conclusions: The pre-operative and 6-month post-operative results of the ST/G ACLR showed that there was a high level of recovery, particularly in quadriceps strength, while the increase in strength was less in the hamstring. The significance observed at 60°/s in H/Q ratios was within normal ranges. It can be argued that the ST/G ACLR method is feasible for people with high physical activity levels and for athletes.

14.
Cureus ; 13(7): e16278, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34373824

RESUMO

Background Medical screws are widely used in orthopedic surgery for fracture fixation. The antibacterial effectiveness of propolis is well known. In this study, we aimed to demonstrate the antibacterial effectiveness of medical screws coated with propolis. Methodology Between March 2019 and April 2020, we formed five experimental groups and investigated the antibacterial activities of different amounts of propolis and polymer-coated screws. Staphylococcus aureus was used to determine the antibacterial activity. Carbopol, chosen as the model polymer, was used to improve the adhesion of propolis to the screws. Agar diffusion test of surface-coated screws was used to evaluate the antibacterial effect. Results The mean zone diameters were 24.3 ± 1.1, 23.0 ± 0.8, 21.8 ± 1.6, 19.3 ± 0.6, and 20.2 ± 0.8 mm for IS-7.5, IS-5.0, IS-2.5, IS-P, and IS-P-7.5, respectively. The IS-7.5 group had the most antibacterial activities. The antibacterial activities of the medical screws determined using the agar diffusion method were significantly increased by the propolis coating on the screws. Our results showed that the propolis-coated screws had antibacterial activity against S. aureus. Conclusions As a result, we believe that the combination of gel and propolis is an effective method in increasing the antibacterial resistance of medical screws and preventing the formation of a biofilm layer of microorganisms.

15.
J Biomater Sci Polym Ed ; 32(8): 980-993, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33492195

RESUMO

Polymethyl methacrylate (PMMA), called as bone cement, has been used in implant surgery, initially in dental practices, then in arthroplasty surgery for decades. Bone cement is a highly preferred chemical in the field of orthopedics due to its bone-like hardness and mechanical strength. Meanwhile, antibiotic-loaded cements are used in joints and similar surgeries are generally due to the risk of infection. In this study, we aimed to demonstrate the effects of borate mineral loading into bone cement on enhancing the antibacterial resistivity and cell integration as well as retaining mechanical properties. Moreover, the incorporation of minerals into bone cements makes them much more cost-friendly biomaterials for surgical operations. Herein, antibacterial properties were evaluated by using vancomycin- and gentamycin-susceptible strains of Enterococcus faecalis and Staphylococcus aureus whereas cell viability tests were performed by osteoblast cell lines. Three sets of the bone cements, plain, calcium borate-, and sodium borate-loaded, were prepared through commercial procedures and subjected to mechanical, antibacterial and cell viability tests. Percentage deformation determined by compression tests under 0.100 MPa pressure was determined in the range of 12.58%-10.67% in respect to the amount of sodium borate mineral loaded whereas that was determined in the range of 12.54%-9.87% in respect to the amount of calcium borate mineral loaded. Micro-CT results also supported good mineral integration and structural features of the composite bone cements. Furthermore, mineral incorporation enhanced the cell viability, in other words, cellular integrity, up to 101.28% for sodium borate-loaded (NB75, 7.5 g mineral) and 72.04% for calcium borate-loaded (CB75, 7.5 g mineral) bone cement according to the negative control group, fresh culture medium. As a conclusion, both of these minerals could be classified as promising alternatives for developing bone cements with better antibacterial resistivity and cellular integration properties.


Assuntos
Boratos , Polimetil Metacrilato , Antibacterianos/farmacologia , Cimentos Ósseos , Minerais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA