Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38878148

RESUMO

Heart failure (HF) is a heterogenous disease requiring precise diagnostics and knowledge of pathophysiological processes. Since structural and functional imaging data are scarce we hypothesized that cardiac magnetic resonance (CMR)-based analyses would provide accurate characterization and mechanistic insights into different HF groups comprising preserved (HFpEF), mid-range (HFmrEF) and reduced ejection fraction (HFrEF). 22 HFpEF, 17 HFmrEF and 15 HFrEF patients as well as 19 healthy volunteers were included. CMR image assessment contained left atrial (LA) and left ventricular (LV) volumetric evaluation as well as left atrioventricular coupling index (LACI). Furthermore, CMR feature-tracking included LV and LA strain in terms of reservoir (Es), conduit (Ee) and active boosterpump (Ea) function. CMR-based tissue characterization comprised T1 mapping as well as late-gadolinium enhancement (LGE) analyses. HFpEF patients showed predominant atrial impairment (Es 20.8%vs.25.4%, p = 0.02 and Ee 8.3%vs.13.5%, p = 0.001) and increased LACI compared to healthy controls (14.5%vs.23.3%, p = 0.004). Patients with HFmrEF showed LV enlargement but mostly preserved LA function with a compensatory increase in LA boosterpump (LA Ea: 15.0%, p = 0.049). In HFrEF LA and LV functional impairment was documented (Es: 14.2%, Ee: 5.4% p < 0.001 respectively; Ea: 8.8%, p = 0.02). This was paralleled by non-invasively assessed progressive fibrosis (T1 mapping and LGE; HFrEF > HFmrEF > HFpEF). CMR-imaging reveals insights into HF phenotypes with mainly atrial affection in HFpEF, ventricular affection with atrial compensation in HFmrEF and global impairment in HFrEF paralleled by progressive LV fibrosis. These data suggest a necessity for a personalized HF management based on imaging findings for future optimized patient management.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38819601

RESUMO

4D-flow MRI is a promising technique for assessing vessel hemodynamics. However, its utilization is currently limited by the lack of reference values, particularly for pulmonary vessels. In this work, we have analysed flow and velocity in the pulmonary trunk (PT), left and right pulmonary arteries (LPA and RPA, respectively) in Landrace pigs at both rest and stress through the software MEVISFlow. Nine healthy Landrace pigs were acutely instrumented closed-chest and transported to the CMR facility for evaluation. After rest measurements, dobutamine was administered to achieve a 25% increase in heart rate compared to rest. 4D-flow MRI images have been analysed through MEVISFlow by two independent observers. Inter- and intra-observer reproducibility was quantified using intraclass correlation coefficient. A significant difference between rest and stress regarding flow and velocity in all the pulmonary vessels was observed. Mean flow increased 55% in PT, 75% in LPA and 40% in RPA. Mean peak velocity increased 55% in PT, 75% in LPA and 66% in RPA. A good-to-excellent reproducibility was observed in rest and stress for flow measurements in all three arteries. An excellent reproducibility for velocity was found in PT at rest and stress, a good one for LPA and RPA at rest, while poor reproducibility was found at stress. The current study showed that pulmonary flow and velocity assessed through 4D-flow MRI follow the physiological alterations during cardiac cycle and after stress induced by dobutamine. A clinical translation to assess pulmonary diseases with 4D-flow MRI under stress conditions needs investigation.

3.
Sci Rep ; 14(1): 634, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182625

RESUMO

Cardiovascular magnetic resonance (CMR)-derived hemodynamic force (HDF) analyses have been introduced recently enabling more in-depth cardiac function evaluation. Inter-study reproducibility is important for a widespread clinical use but has not been quantified for this novel CMR post-processing tool yet. Serial CMR imaging was performed in 11 healthy participants in a median interval of 63 days (range 49-87). HDF assessment included left ventricular (LV) longitudinal, systolic peak and impulse, systolic/diastolic transition, diastolic deceleration as well as atrial thrust acceleration forces. Inter-study reproducibility and study sample sizes required to demonstrate 10%, 15% or 20% relative changes of HDF measurements were calculated. In addition, intra- and inter-observer analyses were performed. Intra- and inter-observer reproducibility was excellent for all HDF parameters according to intraclass correlation coefficient (ICC) values (> 0.80 for all). Inter-study reproducibility of all HDF parameters was excellent (ICC ≥ 0.80 for all) with systolic parameters showing lower coeffients of variation (CoV) than diastolic measurements (CoV 15.2% for systolic impulse vs. CoV 30.9% for atrial thrust). Calculated sample sizes to detect relative changes ranged from n = 12 for the detection of a 20% relative change in systolic impulse to n = 200 for the detection of 10% relative change in atrial thrust. Overall inter-study reproducibility of CMR-derived HDF assessments was sufficient with systolic HDF measurements showing lower inter-study variation than diastolic HDF analyses.


Assuntos
Hemodinâmica , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Átrios do Coração , Espectroscopia de Ressonância Magnética
4.
Sci Rep ; 14(1): 1094, 2024 01 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212323

RESUMO

Cardiac magnetic resonance (CMR) is the gold standard for the diagnostic classification and risk stratification in most patients with cardiac disorders. The aim of the present study was to investigate the ability of Strain-encoded MR (SENC) for the prediction of major adverse cardiovascular events (MACE). A systematic review and meta-analysis was performed according to the PRISMA Guidelines, including patients with or without cardiovascular disease and asymptomatic individuals. Myocardial strain by HARP were used as pulse sequences in 1.5 T scanners. Published literature in MEDLINE (PubMed) and Cochrane's databases were explored before February 2023 for studies assessing the clinical utility of myocardial strain by Harmonic Phase Magnetic Resonance Imaging (HARP), Strain-encoded MR (SENC) or fast-SENC. In total, 8 clinical trials (4 studies conducted in asymptomatic individuals and 4 in patients with suspected or known cardiac disease) were included in this systematic review, while 3 studies were used for our meta-analysis, based on individual patient level data. Kaplan-Meier analysis and Cox proportional hazard models were used, testing the ability of myocardial strain by HARP and SENC/fast-SENC for the prediction of MACE. Strain enabled risk stratification in asymptomatic individuals, predicting MACE and the development of incident heart failure. Of 1332 patients who underwent clinically indicated CMR, including SENC or fast-SENC acquisitions, 19 patients died, 28 experienced non-fatal infarctions, 52 underwent coronary revascularization and 86 were hospitalized due to heart failure during median 22.4 (17.2-28.5) months of follow-up. SENC/fast-SENC, predicted both all-cause mortality and MACE with high accuracy (HR = 3.0, 95% CI = 1.2-7.6, p = 0.02 and HR = 4.1, 95% CI = 3.0-5.5, respectively, p < 0.001). Using hierarchical Cox-proportional hazard regression models, SENC/fast-SENC exhibited incremental value to clinical data and conventional CMR parameters. Reduced myocardial strain predicts of all-cause mortality and cardiac outcomes in symptomatic patients with a wide range of ischemic or non-ischemic cardiac diseases, whereas in asymptomatic individuals, reduced strain was a precursor of incident heart failure.


Assuntos
Cardiopatias , Insuficiência Cardíaca , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Prognóstico
5.
Diagnostics (Basel) ; 14(2)2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38248031

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary widely in the degree of automation, resulting in differences in terms of reproducibility and time spent. AIM: To compare the reproducibility and time spent of two CCTA analysis software tools using different algorithms for the quantitative assessment of coronary plaque volumes and composition in two independent patient cohorts. METHODS: The study population included 100 patients from two different cohorts: 50 patients from a single-center (Siemens Healthineers, SOMATOM Force (DSCT)) and another 50 patients from a multi-center study (5 different > 64 slice CT scanner types). Quantitative measurements of total calcified and non-calcified plaque volume of the right coronary artery (RCA), left anterior descending (LAD), and left circumflex coronary artery (LCX) were performed on a total of 300 coronaries by two independent readers, using two different CCTA analysis software tools (Tool #1: Siemens Healthineers, syngo.via Frontier CT Coronary Plaque Analysis and Tool #2: Siemens Healthineers, successor CT Coronary Plaque Analysis prototype). In addition, the total time spent for the analysis was recorded with both programs. RESULTS: The patients in cohorts 1 and 2 were 62.8 ± 10.2 and 70.9 ± 11.7 years old, respectively, 10 (20.0%) and 35 (70.0%) were female and 34 (68.0%) and 20 (40.0%), respectively, had hyperlipidemia. In Cohort #1, the inter- and intra-observer variabilities for the assessment of plaque volumes per patient for Tool #1 versus Tool #2 were 22.8%, 22.0%, and 26.0% versus 2.3%, 3.9%, and 2.5% and 19.7%, 21.4%, and 22.1% versus 0.2%, 0.1%, and 0.3%, respectively, for total, noncalcified, and calcified lesions (p < 0.001 for all between Tools #1 and 2 both for inter- and intra-observer). The inter- and intra-observer variabilities using Tool #2 remained low at 2.9%, 2.7%, and 3.0% and 3.8%, 3.7%, and 4.0%, respectively, for total, non-calcified, and calcified lesions in Cohort #2. For each dataset, the median processing time was higher for Tool #1 versus Tool #2 (459.5 s IQR = 348.0-627.0 versus 208.5 s; IQR = 198.0-216.0) (p < 0.001). CONCLUSION: The plaque analysis Tool #2 (CT-guided PCI) encompassing a higher degree of automated support required less manual editing, was more time-efficient, and showed a higher intra- and inter-observer reproducibility for the quantitative assessment of plaque volumes both in a representative single-center and in a multi-center validation cohort.

6.
Infection ; 52(1): 93-104, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37434025

RESUMO

BACKGROUND: The severe acute respiratory syndrome corona virus 2 (SARS-CoV-2) pandemic causes a high burden of acute and long-term morbidity and mortality worldwide despite global efforts in containment, prophylaxis, and therapy. With unprecedented speed, the global scientific community has generated pivotal insights into the pathogen and the host response evoked by the infection. However, deeper characterization of the pathophysiology and pathology remains a high priority to reduce morbidity and mortality of coronavirus disease 2019 (COVID-19). METHODS: NAPKON-HAP is a multi-centered prospective observational study with a long-term follow-up phase of up to 36 months post-SARS-CoV-2 infection. It constitutes a central platform for harmonized data and biospecimen for interdisciplinary characterization of acute SARS-CoV-2 infection and long-term outcomes of diverging disease severities of hospitalized patients. RESULTS: Primary outcome measures include clinical scores and quality of life assessment captured during hospitalization and at outpatient follow-up visits to assess acute and chronic morbidity. Secondary measures include results of biomolecular and immunological investigations and assessment of organ-specific involvement during and post-COVID-19 infection. NAPKON-HAP constitutes a national platform to provide accessibility and usability of the comprehensive data and biospecimen collection to global research. CONCLUSION: NAPKON-HAP establishes a platform with standardized high-resolution data and biospecimen collection of hospitalized COVID-19 patients of different disease severities in Germany. With this study, we will add significant scientific insights and provide high-quality data to aid researchers to investigate COVID-19 pathophysiology, pathology, and chronic morbidity.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , SARS-CoV-2 , Pandemias/prevenção & controle , Qualidade de Vida , Alemanha/epidemiologia , Estudos Observacionais como Assunto
7.
Clin Res Cardiol ; 113(3): 469-480, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38095711

RESUMO

AIM: To evaluate the ability of fast strain-encoded (SENC) cardiac magnetic resonance (CMR) derived myocardial strain and native T1 mapping to discriminate between hypertrophic cardiomyopathy (HCM) and cardiac amyloidosis. METHODS: Ninety nine patients (57 with hypertrophic cardiomyopathy and 42 with cardiac amyloidosis) were systematically analysed. LV-ejection fraction, LV-mass index, septal wall thickness and native T1 mapping values were assessed. In addition, global circumferential and longitudinal strain and segmental circumferential and longitudinal strain in basal, mid-ventricular, and apical segments were calculated. A ratio was built by dividing native T1 values by basal segmental strain (T1-to-basal segmental strain ratio). RESULTS: Myocardial strain was equally distributed in apical and basal segments in HCM patients, whereas an apical sparing with less impaired apical strain was noticed in cardiac amyloidosis (apical-to-basal-ratio of 1.01 ± 0.23 versus 1.20 ± 0.28, p < 0.001). T1 values were significantly higher in amyloidosis compared to HCM patients (1170.7 ± 66.4 ms versus 1078.3 ± 57.4ms, p < 0.001). The T1-to-basal segmental strain ratio exhibited high accuracy for the differentiation between the two clinical entities (Sensitivity = 85%, Specificity = 77%, AUC = 0.90, 95% CI = 0.81-0.95, p < 0.001). Multivariable analysis showed that age and the T1-to-basal-strain-ratio were the most robust factors for the differentiation between HCM and cardiac amyloidosis. CONCLUSION: The T1-to-basal-segmental strain ratio, combining information from segmental circumferential and longitudinal strain and native T1 mapping aids the differentiation between HCM and cardiac amyloidosis with high accuracy and within a fast CMR protocol, obviating the need for contrast agent administration.


Assuntos
Amiloidose , Cardiomiopatia Hipertrófica , Humanos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Miocárdio/patologia , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética/métodos , Amiloidose/diagnóstico , Espectroscopia de Ressonância Magnética
8.
Int J Cardiol ; 396: 131563, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37926379

RESUMO

BACKGROUND: Myocardial deformation assessment by cardiovascular magnetic resonance-feature tracking (CMR-FT) has incremental prognostic value over volumetric analyses. Recently, atrial functional analyses have come to the fore. However, to date recommendations for optimal resolution parameters for accurate atrial functional analyses are still lacking. METHODS: CMR-FT was performed in 12 healthy volunteers and 9 ischemic heart failure (HF) patients. Cine sequences were acquired using different temporal (20, 30, 40 and 50 frames/cardiac cycle) and spatial resolution parameters (high 1.5 × 1.5 mm in plane and 5 mm slice thickness, standard 1.8 × 1.8 × 8 mm and low 3.0 × 3.0 × 10 mm). Inter- and intra-observer reproducibility were calculated. RESULTS: Increasing temporal resolution is associated with higher absolute strain and strain rate (SR) values. Significant changes in strain assessment for left atrial (LA) total strain occurred between 20 and 30 frames/cycle amounting to 2,5-4,4% in absolute changes depending on spatial resolution settings. From 30 frames/cycle onward, absolute strain values remained unchanged. Significant changes of LA strain rate assessment were observed up to the highest temporal resolution of 50 frames/cycle. Effects of spatial resolution on strain assessment were smaller. For LA total strain a general trend emerged for a mild decrease in strain values obtained comparing the lowest to the highest spatial resolution at temporal resolutions of 20, 40 and 50 frames/cycle (p = 0.006-0.046) but not at 30 frames/cycle (p = 0.140). CONCLUSION: Temporal and to a smaller extent spatial resolution affect atrial functional assessment. Consistent strain assessment requires a standard spatial resolution and a temporal resolution of 30 frames/cycle, whilst SR assessment requires even higher settings of at least 50 frames/cycle.


Assuntos
Função do Átrio Esquerdo , Imagem Cinética por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Átrios do Coração/diagnóstico por imagem , Função Ventricular Esquerda , Valor Preditivo dos Testes
9.
Sci Rep ; 13(1): 22656, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-38114509

RESUMO

Heart failure (HF) presents manifestations in both cardiac and vascular abnormalities. Pulmonary hypertension (PH) is prevalent in up 50% of HF patients. While pulmonary arterial hypertension (PAH) is closely associated with pulmonary artery (PA) stiffness, the association of HF caused, post-capillary PH and PA stiffness is unknown. We aimed to assess and compare PA stiffness and blood flow hemodynamics noninvasively across HF entities and control subjects without HF using CMR. We analyzed data of a prospectively conducted study with 74 adults, including 55 patients with HF across the spectrum (20 HF with preserved ejection fraction [HFpEF], 18 HF with mildly-reduced ejection fraction [HFmrEF] and 17 HF with reduced ejection fraction [HFrEF]) as well as 19 control subjects without HF. PA stiffness was defined as reduced vascular compliance, indicated primarily by the relative area change (RAC), altered flow hemodynamics were detected by increased flow velocities, mainly by pulse wave velocity (PWV). Correlations between the variables were explored using correlation and linear regression analysis. PA stiffness was significantly increased in HF patients compared to controls (RAC 30.92 ± 8.47 vs. 50.08 ± 9.08%, p < 0.001). PA blood flow parameters were significantly altered in HF patients (PWV 3.03 ± 0.53 vs. 2.11 ± 0.48, p < 0.001). These results were consistent in all three HF groups (HFrEF, HFmrEF and HFpEF) compared to the control group. Furthermore, PA stiffness was associated with higher NT-proBNP levels and a reduced functional status. PA stiffness can be assessed non-invasively by CMR. PA stiffness is increased in HFrEF, HFmrEF and HFpEF patients when compared to control subjects.Trial registration The study was registered at the German Clinical Trials Register (DRKS, registration number: DRKS00015615).


Assuntos
Insuficiência Cardíaca , Adulto , Humanos , Artéria Pulmonar/diagnóstico por imagem , Análise de Onda de Pulso , Volume Sistólico/fisiologia , Espectroscopia de Ressonância Magnética , Prognóstico
10.
J Cardiovasc Dev Dis ; 10(8)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37623329

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) imaging with gadolinium-based contrast agents offers unique non-invasive insights into cardiac tissue composition. Myocardial extracellular volume (ECV) has evolved as an objective and robust parameter with broad diagnostic and prognostic implications. For the gadolinium compound gadobutrol, the recommended dose for cardiac imaging, including ECV measurements, is 0.1 mmol/kg (single dose). This dose was optimized for late enhancement imaging, a measure of focal fibrosis. Whether a lower dose is sufficient for ECV measurements is unknown. We aim to evaluate the accuracy of ECV measurements using a half dose of 0.05 mmol/kg gadobutrol compared to the standard single dose of 0.1 mmol/kg. METHODS AND RESULTS: From a contemporary trial (NCT04747366, registered 10 February 2021), a total of 25 examinations with available T1 mapping before and after 0.05 and 0.1 mmol/kg gadobutrol were analyzed. ECV values were calculated automatically from pre- and post-contrast T1 relaxation times. T1 and ECV Measurements were performed in the midventricular septum. ECV values after 0.05 and 0.1 mmol/kg gadobutrol were correlated (R2 = 0.920, p < 0.001). ECV values after 0.05 mmol/kg had a bias of +0.9% (95%-CI [0.4; 1.4], p = 0.002) compared to 0.1 mmol/kg gadobutrol, with limits of agreement from -1.5 to 3.3%. CONCLUSIONS: CMR with a half dose of 0.05 mmol/kg gadobutrol overestimated ECV by 0.9% compared with a full dose of 0.1 mmol/kg, necessitating adjustment of normal values when using half-dose ECV imaging.

11.
J Cardiovasc Dev Dis ; 10(7)2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37504550

RESUMO

BACKGROUND: Left ventricular global longitudinal strain (LV GLS) is a superior predictor of adverse cardiac events in patients with myocardial infarction and heart failure. We investigated the ability of morphological features of infarcted myocardium to detect acute left ventricular (LV) dysfunction and predict LV functional recovery after three months in patients with acute ST-segment elevation myocardial infarction (STEMI). METHODS: Sixty-six STEMI patients were included in the C-reactive protein (CRP) apheresis in Acute Myocardial Infarction Study (CAMI-1). LV ejection fraction (LVEF), LV GLS, LV global circumferential strain (LV GCS), infarct size (IS), area-at-risk (AAR), and myocardial salvage index (MSI) were assessed by CMR 5 ± 3 days (baseline) and 12 ± 2 weeks after (follow-up) the diagnosis of first acute STEMI. RESULTS: Significant changes in myocardial injury parameters were identified after 12 weeks of STEMI diagnosis. IS decreased from 23.59 ± 11.69% at baseline to 18.29 ± 8.32% at follow-up (p < 0.001). AAR and MVO also significantly reduced after 12 weeks. At baseline, there were reasonably moderate correlations between IS and LVEF (r = -0.479, p < 0.001), LV GLS (r = 0.441, p < 0.001) and LV GCS (r = 0.396, p = 0.001) as well as between AAR and LVEF (r = -0.430, p = 0.003), LV GLS (r = 0.501, p < 0.001) and weak with LV GCS (r = 0.342, p = 0.020). At follow-up, only MSI and change in LV GCS over time showed a weak but significant correlation (r = -0.347, p = 0.021). Patients with larger AAR at baseline improved more in LVEF (p = 0.019) and LV GLS (p = 0.020) but not in LV GCS. CONCLUSION: The CMR tissue characteristics of myocardial injury correlate with the magnitude of LV dysfunction during the acute stage of STEMI. AAR predicts improvement in LVEF and LV GLS, while MSI is a sensitive marker of LV GCS recovery at three months follow-up after STEMI.

13.
Am J Cardiovasc Dis ; 13(2): 73-86, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37213319

RESUMO

AIMS: No data is available about the significance of cardiovascular magnetic resonance (CMR) derived vascular distensibility (VD) and vessel wall ratio (VWR) for risk stratification in patients with type 2 diabetes mellitus (T2DM). Therefore, this study aimed to investigate the effects of T2DM on VD and VWR using CMR in both central and peripheral territories. METHODS: Thirty-one T2DM-patients and nine controls underwent CMR. Angulation of the aorta, the common carotid, and the coronary arteries was performed to obtain cross-sectional vessel areas. RESULTS: In T2DM the Carotid-VWR and the Aortic-VWR correlated significantly. Mean values of Carotid-VWR and Aortic-VWR were significantly higher in T2DM than in controls. Coronary-VD was significantly lower in T2DM than in controls. No significant difference in Carotid-VD or Aortic-VD in T2DM vs. controls, respectively, could be observed. In a subgroup of thirteen T2DM patients with coronary artery disease (CAD), Coronary-VD was significantly lower and Aortic-VWR was significantly higher compared to T2DM patients without CAD. CONCLUSION: CMR allows a simultaneous evaluation of the structure and function of three important vascular territories to detect vascular remodeling in T2DM.

14.
Front Cardiovasc Med ; 10: 1102502, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37077748

RESUMO

4D PC MRI of the aorta has become a routinely available examination, and a multitude of single parameters have been suggested for the quantitative assessment of relevant flow features for clinical studies and diagnosis. However, clinically applicable assessment of complex flow patterns is still challenging. We present a concept for applying radiomics for the quantitative characterization of flow patterns in the aorta. To this end, we derive cross-sectional scalar parameter maps related to parameters suggested in literature such as throughflow, flow direction, vorticity, and normalized helicity. Derived radiomics features are selected with regard to their inter-scanner and inter-observer reproducibility, as well as their performance in the differentiation of sex-, age- and disease-related flow properties. The reproducible features were tested on user-selected examples with respect to their suitability for characterizing flow profile types. In future work, such signatures could be applied for quantitative flow assessment in clinical studies or disease phenotyping.

15.
J Cardiovasc Med (Hagerstown) ; 24(4): 244-252, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36938808

RESUMO

BACKGROUND AND AIMS: High epicardial adipose tissue (EAT) attenuation is a key characteristic of adipose tissue dysfunction and associated with coronary artery disease (CAD). As little is known about the modulation of EAT attenuation by metabolic disorders, we investigated the association between EAT attenuation and CAD risk factors, CAD presence and CAD severity in type 2 diabetes mellitus (T2DM) patients. METHODS: We included 276 inpatients with T2DM and 305 control patients with normal glucose metabolism (NGM), who underwent cardiac computed tomography angiography (CCTA) and coronary artery calcium (CAC) scoring. EAT attenuation and volume were evaluated by contrast-enhanced CCTA image analysis. Furthermore, segment stenosis scores (SSSs) of the left main coronary artery (LMCA), left anterior descending artery (LAD), left circumflex artery (LCX), right coronary artery (RCA), diagonal/intermediate branch (D/I) and obtuse marginal branch (OM) were calculated to assess CAD severity. RESULTS: T2DM patients showed higher significant CAC scores, coronary plaque prevalence, total SSSs and LMCA-SSSs, LAD-SSSs, LCX-SSSs, RCA-SSSs and D/I-SSSs compared with NGM controls. In contrast to NGM controls, EAT volume was significantly increased in T2DM patients, whereas EAT attenuation was similar. In T2DM patients, EAT attenuation was associated with discrete CAD risk factors, the presence of coronary and triple-vessel plaques, as well as LAD-SSSs, LCX-SSSs, RCA-SSSs and total SSSs. In addition, EAT attenuation was only associated with the total SSS of calcified plaques, but not with noncalcified plaques. CONCLUSION: In T2DM patients, high EAT attenuation is associated with the presence and severity of CAD in general and with coronary stenosis caused by calcified plaques in particular.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Diabetes Mellitus Tipo 2 , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/complicações , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Angiografia Coronária/métodos , Pericárdio/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/complicações , Vasos Coronários/diagnóstico por imagem , Constrição Patológica , Tecido Adiposo/diagnóstico por imagem
16.
Front Cardiovasc Med ; 10: 1038337, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36844739

RESUMO

Aims: Heart failure (HF) does not only reduce the life expectancy in patients, but their life is also often limited by HF symptoms leading to a reduced quality of life (QoL) and a diminished exercise capacity. Novel parameters in cardiac imaging, including both global and regional myocardial strain imaging, promise to contribute to better patient characterization and ultimately to better patient management. However, many of these methods are not part of clinical routine yet, their associations with clinical parameters have been poorly studied. An imaging parameters that also indicate the clinical symptom burden of HF patients would make cardiac imaging more robust toward incomplete clinical information and support the clinical decision process. Methods and results: This prospective study conducted at two centers in Germany between 2017 and 2018 enrolled stable outpatient subjects with HF [n = 56, including HF with reduced ejection fraction (HFrEF), HF with mid-range ejection fraction (HFmrEF), and HF with preserved ejection fraction (HFpEF)] and a control cohort (n = 19). Parameters assessed included measures for external myocardial function, for example, cardiac index and myocardial deformation measurements by cardiovascular magnetic resonance imaging, left ventricular global longitudinal strain (GLS), the global circumferential strain (GCS), and the regional distribution of segment deformation within the LV myocardium, as well as basic phenotypical characteristics including the Minnesota Living with Heart Failure Questionnaire (MLHFQ) and the 6-minute walk test (6MWT). If less than 80% of the LV segments are preserved in their deformation capacity the functional capacity by 6MWT (6 minutes walking distance: MyoHealth ≥ 80%: 579.8 ± 177.6 m; MyoHealth 60-<80%: 401.3 ± 121.7 m; MyoHealth 40-<60%: 456.4 ± 68.9 m; MyoHealth < 40%: 397.6 ± 125.9 m, overall p-value: 0.03) as well as the symptom burden are significantly impaired (NYHA class: MyoHealth ≥ 80%: 0.6 ± 1.1 m; MyoHealth 60-<80%: 1.7 ± 1.2 m; MyoHealth 40-<60%: 1.8 ± 0.7 m; MyoHealth < 40%: 2.4 ± 0.5 m; overall p-value < 0.01). Differences were also observed in the perceived exertion assessed by on the Borg scale (MyoHealth ≥ 80%: 8.2 ± 2.3 m; MyoHealth 60-<80%: 10.4 ± 3.2 m; MyoHealth 40-<60%: 9.8 ± 2.1 m; MyoHealth < 40%: 11.0 ± 2.9 m; overall p-value: 0.20) as well as quality of life measures (MLHFQ; MyoHealth ≥ 80%: 7.5 ± 12.4 m; MyoHealth 60-<80%: 23.4 ± 23.4 m; MyoHealth 40-<60%: 20.5 ± 21.2 m; MyoHealth < 40%: 27.4 ± 24.4 m; overall p-value: 0.15)-while these differences were not significant. Conclusion: The share of LV segments with preserved myocardial contraction promises to discriminate between symptomatic and asymptomatic subjects based on the imaging findings, even when the LV ejection fraction is preserved. This finding is promising to make imaging studies more robust toward incomplete clinical information.

17.
N Engl J Med ; 388(6): 575, 2023 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-36780689

Assuntos
Miocardite , Humanos
18.
JACC Cardiovasc Imaging ; 16(5): 609-624, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36752429

RESUMO

BACKGROUND: Myocardial injury in patients with COVID-19 and suspected cardiac involvement is not well understood. OBJECTIVES: The purpose of this study was to characterize myocardial injury in a multicenter cohort of patients with COVID-19 and suspected cardiac involvement referred for cardiac magnetic resonance (CMR). METHODS: This retrospective study consisted of 1,047 patients from 18 international sites with polymerase chain reaction-confirmed COVID-19 infection who underwent CMR. Myocardial injury was characterized as acute myocarditis, nonacute/nonischemic, acute ischemic, and nonacute/ischemic patterns on CMR. RESULTS: In this cohort, 20.9% of patients had nonischemic injury patterns (acute myocarditis: 7.9%; nonacute/nonischemic: 13.0%), and 6.7% of patients had ischemic injury patterns (acute ischemic: 1.9%; nonacute/ischemic: 4.8%). In a univariate analysis, variables associated with acute myocarditis patterns included chest discomfort (OR: 2.00; 95% CI: 1.17-3.40, P = 0.01), abnormal electrocardiogram (ECG) (OR: 1.90; 95% CI: 1.12-3.23; P = 0.02), natriuretic peptide elevation (OR: 2.99; 95% CI: 1.60-5.58; P = 0.0006), and troponin elevation (OR: 4.21; 95% CI: 2.41-7.36; P < 0.0001). Variables associated with acute ischemic patterns included chest discomfort (OR: 3.14; 95% CI: 1.04-9.49; P = 0.04), abnormal ECG (OR: 4.06; 95% CI: 1.10-14.92; P = 0.04), known coronary disease (OR: 33.30; 95% CI: 4.04-274.53; P = 0.001), hospitalization (OR: 4.98; 95% CI: 1.55-16.05; P = 0.007), natriuretic peptide elevation (OR: 4.19; 95% CI: 1.30-13.51; P = 0.02), and troponin elevation (OR: 25.27; 95% CI: 5.55-115.03; P < 0.0001). In a multivariate analysis, troponin elevation was strongly associated with acute myocarditis patterns (OR: 4.98; 95% CI: 1.76-14.05; P = 0.003). CONCLUSIONS: In this multicenter study of patients with COVID-19 with clinical suspicion for cardiac involvement referred for CMR, nonischemic and ischemic patterns were frequent when cardiac symptoms, ECG abnormalities, and cardiac biomarker elevations were present.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Traumatismos Cardíacos , Miocardite , Humanos , Miocardite/patologia , COVID-19/complicações , Estudos Retrospectivos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Troponina , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA