Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Rev Sci Instrum ; 92(6): 063520, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243585

RESUMO

A NASA-built x-ray microcalorimeter spectrometer has been installed on the MST facility at the Wisconsin Plasma Physics Laboratory and has recorded x-ray photons emitted by impurity ions of aluminum in a majority deuterium plasma. Much of the x-ray microcalorimeter development has been driven by the needs of astrophysics missions, where imaging arrays with few-eV spectral resolution are required. The goal of our project is to adapt these single-photon-counting microcalorimeters for magnetic fusion energy research and demonstrate the value of such measurements for fusion science. Microcalorimeter spectrometers combine the best characteristics of the x-ray instrumentation currently available on fusion devices: high spectral resolution similar to an x-ray crystal spectrometer and the broadband coverage of an x-ray pulse height analysis system. Fusion experiments are increasingly employing high-Z plasma-facing components and require measurement of the concentration of all impurity ion species in the plasma. This diagnostic has the capability to satisfy this need for multi-species impurity ion data and will also contribute to measurements of impurity ion temperature and flow velocity, Zeff, and electron density. Here, we introduce x-ray microcalorimeter detectors and discuss the diagnostic capability for magnetic fusion energy experiments. We describe our experimental setup and spectrometer operation approach at MST, and we present the results from an initial measurement campaign.

2.
Rev Sci Instrum ; 91(8): 083110, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32872938

RESUMO

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 µm-200 µm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 µm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

3.
Artigo em Inglês | MEDLINE | ID: mdl-31160861

RESUMO

Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for ESA's Athena satellite mission. X-0IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU. Singlecolumn TDM measurements have best-fit energy resolution of (1.91 ± 0.01) eV for the Al Kα complex (1.5 keV), (2.10 ± 0.02) eV for Ti Kα (4.5 keV), (2.23 ± 0.02) eV for Mn Kα (5.9 keV), (2.40 ± 0.02) eV for Co Kα (6.9 keV), and (3.44 ± 0.04) eV for Br Kα (11.9 keV). Three-column measurements have best-fit resolution of (2.03 ± 0.01) eV for Ti Kα and (2.40 ± 0.01) eV for Co Kα. The degradation due to the multiplexed readout ranges from 0.1 eV at the lower end of the energy range to 0.5 eV at the higher end. The demonstrated performance meets X-IFU's energy-resolution and energy-range requirements. True 40-row TDM readout, without repeated rows, of kilopixel scale arrays of X-IFU-like TESs is now under development.

4.
J Low Temp Phys ; 193(3-4): 321-327, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31186584

RESUMO

We have specialized astronomical applications for X-ray microcalorimeters with superconducting transition edge sensors (TESs) that require exceptionally good TES performance, but which operate in the small-signal regime. We have therefore begun a program to carefully characterize the entire transition surface of TESs with and without the usual zebra stripes to see if there are reproducible local "sweet spots" where the performance is much better than average. These measurements require precise knowledge of the circuit parameters. Here, we show how the Shapiro effect can be used to precisely calibrate the value of the shunt-resistor. We are also investigating the effects of stress and external magnetic fields to better understand reproducibility problems.

5.
J Dev Orig Health Dis ; 8(4): 418-435, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28610639

RESUMO

The phenotype of the human embryo conceived through in vitro fertilization (IVF), that is its morphology, developmental kinetics, physiology and metabolism, can be affected by numerous components of the laboratory and embryo culture system (which comprise the laboratory environment). The culture media formulation is important in determining embryo phenotype, but this exists within a culture system that includes oxygen, temperature, pH and whether an embryo is cultured individually or in a group, all of which can influence embryo development. Significantly, exposure of an embryo to one suboptimal component of the culture system of laboratory typically predisposes the embryo to become more vulnerable to a second stressor, as has been well documented for atmospheric oxygen and individual culture, as well as for oxygen and ammonium. Furthermore, the inherent viability of the human embryo is derived from the quality of the gametes from which it is created. Patient age, aetiology, genetics, lifestyle (as well as ovarian stimulation in women) are all known to affect the developmental potential of gametes and hence the embryo. Thus, as well as considering the impact of the IVF laboratory environment, one needs to be aware of the status of the infertile couple, as this impacts how their gametes and embryos will respond to an in vitro environment. Although far from straight forward, analysing the interactions that exist between the human embryo and its environment will facilitate the creation of more effective and safer treatments for the infertile couple.


Assuntos
Blastocisto/fisiologia , Serviços de Laboratório Clínico/normas , Fertilização in vitro/normas , Fenótipo , Blastocisto/citologia , Meios de Cultura/normas , Técnicas de Cultura Embrionária/métodos , Técnicas de Cultura Embrionária/normas , Feminino , Fertilização in vitro/métodos , Humanos
6.
Rev Sci Instrum ; 87(11): 11D503, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910640

RESUMO

The Hitomi Soft X-ray Spectrometer (SXS) was a pioneering non-dispersive imaging x-ray spectrometer with 5 eV FWHM energy resolution, consisting of an array of 36 silicon-thermistor microcalorimeters at the focus of a high-throughput soft x-ray telescope. The instrument enabled astrophysical plasma diagnostics in the 0.3-12 keV band. We introduce the SXS calibration strategy and corresponding ground calibration measurements that took place from 2012-2015, including both the characterization of the microcalorimeter array and measurements of the x-ray transmission of optical blocking filters.

7.
Rev Sci Instrum ; 87(11): 11E516, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910505

RESUMO

We characterized the dissociation fraction of a thermal dissociation atomic hydrogen source by injecting the mixed atomic and molecular output of the source into an electron beam ion trap containing highly charged ions and recording the x-ray spectrum generated by charge exchange using a high-resolution x-ray calorimeter spectrometer. We exploit the fact that the charge exchange state-selective capture cross sections are very different for atomic and molecular hydrogen incident on the same ions, enabling a clear spectroscopic diagnostic of the neutral species.

8.
Rev Sci Instrum ; 83(10): 10E111, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126933

RESUMO

Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W(64+), which has become the line of choice for the ITER (Latin "the way") core imaging x-ray spectrometer. Close-by standards are the Hf Lß(3) line and the Ir Lα(2) line, which bracket the W(64+) line by ±30 eV; other standards are given by the Ir Lα(1) and Lα(2) lines and the Hf Lß(1) and Lß(2) lines, which bracket the W(64+) line by ±40 and ±160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W(64+) line obtained both with an x-ray microcalorimeter and a crystal spectrometer.

9.
Rev Sci Instrum ; 81(10): 10E314, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034013

RESUMO

The calibration of the soft x-ray spectral response of a large radius of curvature, high resolution grating spectrometer (HRGS) with a back-illuminated charge-coupled device detector is reported. The instrument is cross-calibrated for the 10-50 Å waveband at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) x-ray source with the EBIT calorimeter spectrometer. The HRGS instrument is designed for laser-produced plasma experiments and is important for making high dynamic range measurements of line intensities, line shapes, and x-ray sources.

10.
Rev Sci Instrum ; 81(10): 10E319, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034017

RESUMO

We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of ∼6-60 Å. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer.

11.
Rev Sci Instrum ; 81(10): 10E323, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034021

RESUMO

We describe the anticipated performance of an x-ray microcalorimeter instrument on ITER. As part of the core imaging x-ray spectrometer, the instrument will augment the imaging crystal spectrometers by providing a survey of the concentration of heavy ion plasma impurities in the core and possibly ion temperature values from the emission lines of different elemental ions located at various radial positions.

12.
Vet Ther ; 11(3): E1-14, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20960415

RESUMO

Although probiotics are generally considered to be safe, their increasingly widespread use warrants better understanding of their risks in companion animals. This study evaluated the safety and tolerance of dietary supplementation with a canine-derived probiotic, Bifidobacterium animalis strain AHC7 (Prostora, Procter & Gamble Pet Care), fed to growing beagles beginning at approximately 6 months of age (11 males; 9 females). Probiotic B. animalis AHC7 administered orally once per day at a dose of up to 5 x 1010 colony-forming units for at least 12 consecutive weeks was well tolerated with no safety concerns.


Assuntos
Bifidobacterium/fisiologia , Probióticos/efeitos adversos , Ração Animal/análise , Fenômenos Fisiológicos da Nutrição Animal , Animais , Dieta/veterinária , Suplementos Nutricionais , Cães , Fezes/química , Fezes/microbiologia , Feminino , Masculino , Probióticos/administração & dosagem
13.
Phys Rev Lett ; 105(6): 063201, 2010 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-20867978

RESUMO

We have measured K-shell x-ray spectra of highly ionized argon and phosphorus following charge exchange with molecular hydrogen at low collision energy in an electron beam ion trap using an x-ray calorimeter array with ∼6 eV resolution. We find that the emission at the high end of the Lyman series is greater by a factor of 2 for phosphorus than for argon, even though the measurement was performed concurrently and the atomic numbers are similar. This does not agree with current theoretical models and deviates from the trend observed in previous measurements.

14.
Vet Ther ; 10(3): 121-30, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20037966

RESUMO

This study evaluated the effect of supplementation with canine-derived probiotic Bifidobacterium animalis strain AHC7 (lams Prostora, Procter & Gamble Pet Care) on the resolution rate of acute idiopathic diarrhea in dogs randomly assigned to receive a placebo (n=18) or the probiotic (n=13). Nutritional management with the probiotic fed at 2 x 10(10) CFU/day significantly reduced the time to resolution (3.9 +/- 2.3 versus 6.6 +/- 2.7 days; P < .01) and reduced the percentage of dogs that were administered metronidazole (38.5% versus 50.0%) compared with placebo. Probiotic B. animalis AHC7 may provide veterinarians another tool for management of acute diarrhea in dogs.


Assuntos
Ração Animal/análise , Bifidobacterium , Diarreia/veterinária , Dieta/veterinária , Doenças do Cão/terapia , Probióticos , Animais , Anti-Infecciosos/uso terapêutico , Diarreia/terapia , Cães , Metronidazol/uso terapêutico
15.
Rev Sci Instrum ; 79(10): 10E309, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044471

RESUMO

The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification of filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.

16.
Phys Rev Lett ; 98(14): 142501, 2007 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-17501268

RESUMO

The energy splitting of the 229Th ground-state doublet is measured to be 7.6+/-0.5 eV, significantly greater than earlier measurements. Gamma rays produced following the alpha decay of 233U (105 muCi) were counted in the NASA/electron beam ion trap x-ray microcalorimeter spectrometer with an experimental energy resolution of 26 eV (FWHM). A difference technique was applied to the gamma-ray decay of the 71.82 keV level that populates both members of the doublet. A positive correction amounting to 0.6 eV was made for the unobserved interband decay of the 29.19 keV state (29.19-->0 keV).

17.
Phys Rev Lett ; 96(25): 253201, 2006 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-16907303

RESUMO

By implementing a large-area, gain-stabilized microcalorimeter array on an electron beam ion trap, the electron-impact excitation cross sections for the dominant x-ray lines in the Fe XVII spectrum have been measured as a function of electron energy establishing a benchmark for atomic calculations. The results show that the calculations consistently predict the cross section of the resonance line to be significantly larger than measured. The lower cross section accounts for several problems found when modeling solar and astrophysical Fe XVII spectra.

18.
Science ; 300(5625): 1558-9, 2003 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-12791989

RESUMO

In laboratory experiments using the engineering spare microcalorimeter detector from the ASTRO-E satellite mission, we recorded the x-ray emission of highly charged ions of carbon, nitrogen, and oxygen, which simulates charge exchange reactions between heavy ions in the solar wind and neutral gases in cometary comae. The spectra are complex and do not readily match predictions. We developed a charge exchange emission model that successfully reproduces the soft x-ray spectrum of comet Linear C/1999 S4, observed with the Chandra X-ray Observatory.

19.
Am J Vet Res ; 62(4): 609-15, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11327473

RESUMO

OBJECTIVE: To compare fermentation characteristics of fructooligosaccharides (FOS) and other fiber substrates that are commonly found in canine diets. SAMPLE POPULATION: Fecal samples from 3 adult dogs. PROCEDURE: The ability of fiber substrates to be used in microbial fermentation reactions was assessed by use of an in vitro fermentation system. Dogs were fed a commercially available food, and feces were collected for use as the microbial inoculum. Substrates used were beet pulp, cellulose, soy fiber, mannanoligosaccharides (MOS), FOS, and 4 inulin products (inulin 1, 2, 3, and 4). Each substrate was incubated anaerobically with fecal inoculum and growth media for 6, 12, and 24 hours, and production of short-chain fatty acids (SCFA) was measured. RESULTS: Total production of SCFA was higher for fermentation of the 4 inulin products and FOS, whereas fermentation of beet pulp, MOS, and soy fiber resulted in moderate concentrations of SCFA. Fermentation of cellulose produced the lowest concentrations of total SCFA without detection of butyrate or lactate. Butyrate production was greatest for fermentation of the 4 inulin products and FOS. Total lactate production was greatest for FOS and inulin 4. As expected, production of SCFA increased for all substrates as fermentation time increased. CONCLUSIONS AND CLINICAL RELEVANCE: Canine fecal microflora ferment FOS-containing substrates in a similar manner, with little fermentation of cellulose-based carbohydrates. Furthermore, results of an in vitro fermentation system indicate that fiber type affects the metabolic activity of microorganisms, thus influencing the amount and nature of the end products of fermentation.


Assuntos
Colo/metabolismo , Colo/microbiologia , Fibras na Dieta/metabolismo , Cães/metabolismo , Oligossacarídeos/metabolismo , Animais , Ácidos Graxos Voláteis/análise , Ácidos Graxos Voláteis/biossíntese , Fezes/química , Feminino , Fermentação , Ácido Láctico/análise , Ácido Láctico/biossíntese , Masculino
20.
EMBO J ; 20(9): 2236-45, 2001 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-11331589

RESUMO

In Drosophila, dosage compensation is controlled by the male-specific lethal (MSL) complex consisting of MSL proteins and roX RNAs. The MSL complex is specifically localized on the male X chromosome to increase its expression approximately 2-fold. We recently proposed a model for the targeted assembly of the MSL complex, in which initial binding occurs at approximately 35 dispersed chromatin entry sites, followed by spreading in cis into flanking regions. Here, we analyze one of the chromatin entry sites, the roX1 gene, to determine which sequences are sufficient to recruit the MSL complex. We found association and spreading of the MSL complex from roX1 transgenes in the absence of detectable roX1 RNA synthesis from the transgene. We mapped the recruitment activity to a 217 bp roX1 fragment that shows male-specific DNase hypersensitivity and can be preferentially cross-linked in vivo to the MSL complex. When inserted on autosomes, this small roX1 segment is sufficient to produce an ectopic chromatin entry site that can nucleate binding and spreading of the MSL complex hundreds of kilobases into neighboring regions.


Assuntos
Cromatina/genética , Proteínas Cromossômicas não Histona , DNA Helicases , Proteínas de Ligação a DNA/genética , Mecanismo Genético de Compensação de Dose , Proteínas de Drosophila , Proteínas Repressoras/genética , Animais , Linhagem Celular , Mapeamento Cromossômico , Proteínas de Ligação a DNA/metabolismo , Drosophila , Éxons , Expressão Gênica , Substâncias Macromoleculares , Masculino , Modelos Genéticos , Proteínas Nucleares/genética , RNA Helicases/metabolismo , RNA Mensageiro/biossíntese , Proteínas Repressoras/metabolismo , Proteínas de Saccharomyces cerevisiae , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Transcrição Gênica , Transgenes , Cromossomo X/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA