Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Asian Pac J Cancer Prev ; 25(6): 2105-2112, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38918673

RESUMO

PURPOSE: The aim of this study was to investigate the detector size effect on small-field dosimetry and compare the performance of 6MV WFF/FFF techniques. METHODS: We investigated the detector size effect on small-field dosimetry and compared the performance of 6MV WFF/FFF techniques. PDD, profile curves, and absorbed dose were measured in water under reference conditions with 6MV (WFF/FFF) techniques. We employed Farmer FC65-P, CC13, CC01, and IBA Razor diode, with Versa Lineac. Subsequently, we replicated this assessment for small-fields under 5cmx5cm dimensions. RESULTS: For both 6MV WFF/FFF, significant dose differences (Dmax=1.47cm), were ±4.55%, ±6.7, ±12.75% and ±33.3% for 4cmx4cm, 3cmx3cm, 2cmx2cm, and 1cmx1cm, respectively. The average difference relative to D10 was observed to be ±4.66%, ±5.73%, ±6.58%, and ±8.75% for the previous field sizes. Differences between WFF/FFF are neglected values at all field sizes>2.3%, also, the output of the largest detector FC65-P is lower at 55% in the smallest field size. Variation in the profile doesn't exceed a difference of >5% in flatness between WFF/FFF at depth10cm, across all fields, while symmetry is >1%, but radiation output is considerably lower at 55% for FC65-P chamber in 2cmx2cm, 1cmx1cm compared to the CC01 chamber and Razor diode. Significant differences in 1cmx1cm, where FC65-P chamber exhibits around 49% difference compared to Razor diode with 6MV (WFF/FFF).  Conclusions: Significant differences were observed in doses with various detectors. Detector-size influences the dose. WFF/FFF techniques show no major differences in small-fields dosimetry. Utilize some situations the advantage of FFF boasting a higher dose rate, consequently reducing treatment time to half.


Assuntos
Radiometria , Humanos , Radiometria/métodos , Dosagem Radioterapêutica , Aceleradores de Partículas/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Imagens de Fantasmas
2.
Pol J Radiol ; 85: e586-e594, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33204373

RESUMO

PURPOSE: To explore whether radiomic features of fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomo-graphy-computed tomography (PET/CT) has association with bone marrow infiltration (BMI) in comparison to other conventional PET metrics. MATERIAL AND METHODS: Forty-four patients (with pathologically proven lymphoma disease) underwent staging 18F-FDG PET/CT scan. Primary tumour was semi-automatically or manually segmented with a threshold standardised uptake value (SUV) of 3. A total of 73 features were extracted from eight different textures. Spearman correlation was used to test the correlation of features with conventional quantitative metrics such as SUV, metabolic tumour volume, and total lesion glycolysis. Specificity and sensitivity (including 95% confidence intervals [CI]) for each of the studied parameters were derived using receiver operative characteristic (ROC) curves. Univariate and multivariate analyses were used to identify independent predictors associated with BMI. RESULTS: Correlation between conventional PET metrics and features ranged between 0.50 and 0.97 for positive correlation (33 significant association features) and ranged from -0.52 to -0.97 for inverse correlation (three significant association features) for both strong and moderate correlations. Analysis of ROC curves showed that high-intensity long-run emphasis 4 bin, high-intensity large zone emphasis 64 bin, long-run emphasis (LRE) 64 bin, large-zone emphasis 64 bin, max spectrum 8 bin, busyness 64 bin, and code similarity 32 and 64 bin were significant discriminators of BMI among other features (area under curve > 0.682, p < 0.05). Univariate analyses of texture features showed that code similarity and long-run emphasis (both 64 bin) were significant predictors of bone marrow involvement. Multivariate analyses revealed that LRE (64 bin, p = 0.031) with an odds ratio of 1.022 and 95% CI of (1.002-1.043) were independent variables for bone marrow involvement. CONCLUSIONS: 18F-FDG PET/CT radiomic features are synergistic to visual assessment of BMI in patients diagnosed with lymphoma using 18F-FDG PET/CT. Further assessment of long-run emphasis is highly warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA