Arch Pathol Lab Med ; 2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38031817

RESUMO

CONTEXT.­: The prothrombin time (PT) and activated partial thromboplastin time (APTT) are screening tests used to detect congenital or acquired bleeding disorders. An unexpected PT and/or APTT prolongation is often evaluated using a mixing test with normal plasma. Failure to correct ("noncorrection") prolongation upon mixing is attributed to an inhibitor, whereas "correction" points to factor deficiency(ies). OBJECTIVE.­: To define an optimal method for determining correction or noncorrection of plasma mixing tests through an international, multisite study that used multiple PT and APTT reagents and well-characterized plasma samples. DESIGN.­: Each testing site was provided 22 abnormal and 25 normal donor plasma samples, and mixing studies were performed using local PT and APTT reagents. Mixing study results were evaluated using 11 different calculation methods to assess the optimal method based on the expected interpretation for factor deficiencies (correction) and noncorrection (inhibitor effect). Misprediction, which represents the failure of a mixing study interpretation method, was assessed. RESULTS.­: Percentage correction was the most suitable calculation method for interpreting PT mixing test results for nearly all reagents evaluated. Incubated PT mixing tests should not be performed. For APTT mixing tests, percentage correction should be performed, and if the result indicates a factor deficiency, this should be confirmed with the subtraction III calculation where the normal pooled plasma result (run concurrently) is subtracted from the mixing test result with correction indicated by a result of 0 or less. In general, other calculation methods evaluated that performed well in the identification of factor deficiency tended to have high misprediction rates for inhibitors and vice versa. CONCLUSIONS.­: No single method of mixing test result calculation was consistently successful in accurately distinguishing factor deficiencies from inhibitors, with between-reagent and between-site variability also identified.

2.
Res Pract Thromb Haemost ; 7(3): 100128, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37122532

RESUMO

Background: Anti-platelet factor 4 (PF4) antibodies in vaccine-induced immune thrombotic thrombocytopenia (VITT) appear to be transient, with discrepant persistence depending on the platform used for detection. Objectives: We aimed to report a longitudinal study of antibody persistence using 2 ELISA platforms and 2 platelet-activating functional assays in a clinical cohort of patients with VITT referred for follow-up testing. Methods: In total, 32 Australian patients with VITT or pre-VITT, confirmed by expert adjudication, with samples referred for clinical follow-up were included. Clinical follow-up assays, including Stago and Hyphen ELISAs, procoagulant platelet flow cytometry, and modified PF4-serotonin-release assay, were performed according to the pattern of reactivity for that patient at diagnosis. Results: The median follow-up was 24 weeks after diagnosis. A general decline in anti-PF4 antibody levels and platelet-activating capacity over time was observed with a more rapid median time to resolution of 16 weeks by functional assay vs 24 weeks by Stago ELISA. Decline in platelet-activating antibody levels detected by functional assays mirrored Stago ELISA titer but not Hyphen. However, 87% of patients received a documented second vaccination and 74% received an mRNA booster with no reported adverse events. Conclusion: Anti-PF4 antibodies persist longer than functional platelet-activating antibodies in VITT but do not warrant avoidance of subsequent vaccinations. Persistence detection is assay-dependent. Stago ELISA may be a surrogate where functional assays are unavailable for follow-up testing of confirmed patients with VITT.

3.
Methods Mol Biol ; 2663: 429-440, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204728

RESUMO

Vaccine-induced immune thrombotic thrombocytopenia (VITT) was first described in 2021 and represents an adverse reaction to adenoviral vector COVID-19 vaccines AstraZeneca ChAdOx1 nCoV-19 (AZD1222) and Johnson & Johnson Ad26.COV2.S vaccine. VITT is a severe immune platelet activation syndrome with an incidence of 1-2 per 100,000 vaccinations. The features of VITT include thrombocytopenia and thrombosis within 4-42 days of first dose of vaccine. Affected individuals develop platelet-activating antibodies against platelet factor 4 (PF4). The International Society on Thrombosis and Haemostasis recommends both an antigen-binding assay (enzyme-linked immunosorbent assay, ELISA) and a functional platelet activation assay for the diagnostic workup of VITT. Here, the application of multiple electrode aggregometry (Multiplate) is presented as a functional assay for VITT.


Assuntos
COVID-19 , Trombocitopenia , Vacinas , Humanos , ChAdOx1 nCoV-19 , Ad26COVS1 , Vacinas contra COVID-19/efeitos adversos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Anticorpos , Eletrodos , Fator Plaquetário 4
4.
Methods Mol Biol ; 2663: 589-595, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37204738

RESUMO

Emicizumab is a bi-specific antibody that in recent years has been introduced in many countries as a prophylactic agent for bleed prevention in cases of severe hemophilia A, and in some cases of moderate HA. It can be used in individuals with HA with and without FVIII inhibitors, because the drug is not a target for these inhibitors. Emicizumab was developed as a fixed weight-based dose and does not normally need laboratory monitoring, but in some circumstances such as a treated HA patient with unexpected bleeding episodes, a laboratory assay is justified. This chapter describes to performance of a one-stage clotting assay to measure emicizumab.


Assuntos
Anticorpos Biespecíficos , Hemofilia A , Humanos , Hemostasia , Hemofilia A/tratamento farmacológico , Hemorragia/prevenção & controle , Anticorpos Biespecíficos/uso terapêutico , Fator VIII
5.
Semin Thromb Hemost ; 49(6): 571-579, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36055261

RESUMO

Mixing studies have long been in the clinical laboratory armamentarium for investigating unexpected, prolonged activated partial thromboplastin time (aPTT) or prothrombin time (PT). The purpose of the mixing study is to identify whether the aPTT/PT prolongation is secondary to a factor deficiency versus an inhibitor, which would present as a "corrected" and "noncorrected" mixing study, respectively. The differentiation between a factor deficiency and inhibitor may likely further direct clinical decisions, including additional diagnostic testing or factor replacement therapy. While aPTT/PT mixing studies are simple tests to perform, there is a lack of standardization for both the testing protocol and the interpretation of what is considered to be a corrected or noncorrected mixing study result. This review will describe the common indications for the mixing test, preanalytic variables that may affect mixing study performance, and describe several methods for interpreting the results of aPTT and PT mixing tests.


Assuntos
Transtornos da Coagulação Sanguínea , Humanos , Tempo de Protrombina , Tempo de Tromboplastina Parcial , Testes de Coagulação Sanguínea/métodos , Transtornos da Coagulação Sanguínea/diagnóstico , Padrões de Referência
6.
J Thromb Haemost ; 20(12): 2896-2908, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36107495

RESUMO

BACKGROUND: Vaccine-induced thrombotic thrombocytopenia (VITT) is a rare complication of adenovirus-based vaccines aimed to prevent and minimize COVID-19 and related pathophysiology. OBJECTIVES: To describe patterns of testing for anti-platelet factor 4 (PF4) antibodies using various ELISA assays in a large Australian cohort and comparative functional platelet activation assays in a subset. PATIENTS/METHODS: Asserachrom HPIA IgG ELISA was performed in 1284 patients over a period of 12 months, supplemented in select cohorts by comparative ELISA using three other methods (n = 78-179), three different functional assays (flow cytometry, serotonin release assay, and/or Multiplate; n = 476), and rapid immunological chemiluminescence anti-PF4 assay (n = 460), in a multicenter study. RESULTS: For first episode presentations, 190/1284 (14.8%) ELISA tests were positive. Conversely, most (445/460; 96.7%) chemiluminescence anti-PF4 test results were negative. All functional assays showed associations of higher median ELISA optical density with functional positivity and with high rates of ELISA positivity (64.0% to 85.2%). Data also identified functional positivity in 14.8%-36.0% of ELISA negative samples, suggesting false negative VITT by HPIA IgG ELISA in upward of one third of assessable cases. CONCLUSION: To our knowledge, this is the largest multicenter evaluation of anti-PF4 testing for investigation of VITT. Discrepancies in test results (ELISA vs. ELISA or ELISA vs. functional assay) in some patients highlighted limitations in relying on single methods (ELISA and functional) for PF4 antibody detection in VITT, and also highlights the variability in phenotypic test presentation and pathomechanism of VITT.


Assuntos
COVID-19 , Trombocitopenia , Trombose , Vacinas , Humanos , Fator Plaquetário 4 , Heparina/efeitos adversos , Austrália , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Trombose/diagnóstico , Fatores Imunológicos/efeitos adversos , Imunoglobulina G
7.
Blood Coagul Fibrinolysis ; 33(7): 402-411, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35867944

RESUMO

Coagulation factor testing is commonly performed within haemostasis laboratories, either to assess for bleeding disorders, such as haemophilia, or to investigate unexplained prolongation in routine coagulation assays. The aim of this evaluation was to harmonize procedures and normal reference ranges (NRRs) for investigation of coagulation factors on the ACL TOP 50 family of instruments in a large laboratory network. We employed comparative evaluations using newly installed ACL TOPs 550 and 750 and HemosIL reagents vs. existing 'reference' instrumentation and reagents, predominantly Stago and Siemens, as well as assessment of factor sensitivity in routine coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT). Also, establishment of coagulation factor NRRs using normal plasma samples. HemosIL factor assays showed good comparability with the existing reference methods ( R > 0.9). Factor sensitivity for PT and APTT assays were acceptable at around 30 U/dl. NRRs were established and harmonized across the laboratory network. This evaluation of factor testing on ACL TOP 50 Family instruments identified overall acceptable performance using Werfen reagents and enabled harmonization of coagulation factor testing in our large network.


Assuntos
Fatores de Coagulação Sanguínea , Laboratórios , Testes de Coagulação Sanguínea/métodos , Humanos , Tempo de Tromboplastina Parcial , Tempo de Protrombina/métodos
8.
Int J Lab Hematol ; 44(5): 934-944, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35754202

RESUMO

INTRODUCTION: The platelet function analyzer (PFA) is a popular platelet function screening instrument, highly sensitive to von Willebrand disease (VWD) and to aspirin therapy, with moderate sensitivity to defects in platelet function and/or deficiencies in platelet number. There are two models, the original PFA-100 and the contemporary PFA-200. Normal reference ranges (NRRs) provided by the manufacturer are the same for both models, instead being based on the type of test cartridge, for which there are two main ones: collagen/epinephrine (C/Epi) and collagen/adenosine diphosphate (C/ADP). METHODS: Comparative evaluations of PFA testing and reporting in six different sites of a large pathology network, aiming to harmonize NRRs and test reporting across all network sites. A separate comparative study of testing a range of samples (n > 150) on a PFA-100 versus that on a PFA-200. Review of contemporary literature. RESULTS: Each site was identified to have a different reporting NRR, which after consolidating data permitted establishment of an agreed harmonized NRR for use across the network (C/Epi: 90-160; C/ADP: 70-124; based on n > 180). Similarly, each site reported and interpreted results in different ways, and after discussion and consolidation, a harmonized approach to interpretation and reporting was achieved. The separate comparative study of PFA-100 versus PFA-200 testing confirmed instrument equivalence. CONCLUSION: We achieved harmonized NRRs and reporting for PFA testing across a large pathology network. Our approach may be useful for other laboratory networks wishing to harmonize PFA testing.


Assuntos
Testes de Função Plaquetária , Doenças de von Willebrand , Difosfato de Adenosina , Plaquetas , Colágeno , Epinefrina , Humanos , Sensibilidade e Especificidade , Doenças de von Willebrand/diagnóstico
9.
Pathology ; 54(6): 755-762, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35577608

RESUMO

Emicizumab is a recombinant, humanised bispecific antibody which acts as a FVIII mimetic and is a therapeutic option for haemophilia A. Plasma emicizumab levels may sometimes be required. Multiple one-stage clotting assays (OSA) and one human component chromogenic assay (CSA) were used to measure emicizumab both centrally and by a field study. The study samples drug concentrations range included within therapy range of 35-70 µg/mL. All assays were modified from traditional FVIII assays to enable replacement of plasma calibrators with emicizumab calibrators. Central laboratory OSA mean recovery levels (target) for six spike levels of emicizumab were close to target at 120.5 (120), 81.6 (80), 40.9 (40), 21.4 (20), 10.7 (10) and 5.5 (5) µg/mL. Field study OSA mean recoveries were similarly close to target. Between method coefficients of variation were <9% in both the central laboratory and field study assays, except for the 5 µg/mL sample which was 12.3%. CSA mean recoveries were within 10% of target at 80, 50 and 20 µg/mL levels. This study affirms that emicizumab can be measured by OSA using many types of activated partial thromboplastin time (APTT) reagents and is also measurable by the human CSA. The assays showed good precision, accuracy and linearity both locally and in a field study setting.


Assuntos
Anticorpos Biespecíficos , Hemofilia A , Humanos , Anticorpos Biespecíficos/farmacologia , Anticorpos Biespecíficos/uso terapêutico , Anticorpos Monoclonais Humanizados , Austrália , Fator VIII/uso terapêutico , Hemofilia A/diagnóstico , Hemofilia A/tratamento farmacológico
10.
Int J Lab Hematol ; 44(3): 654-665, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35234361

RESUMO

INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new "single platform" of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utility in LA testing. METHODS: Comparative evaluations of LA testing using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing "reference," predominantly Stago, instrumentation, and reagents. Evaluations comprised both dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (APTT)-based assays. Establishment of normal reference ranges (NRR). RESULTS: The HemosIL dRVVT-based assays showed good comparability with the existing Stago reference method (R > 0.9) and could be considered as verified as fit for purpose. A variety of APTT assays was additionally evaluated for LA utility, and we identified from the assessment good utility of a non-Werfen solution in Hyphen BioMed Cephen reagents. NRR were established based on ≥120 normal individual plasma samples. CONCLUSION: This evaluation of LA reagents on ACL TOP 50 Family instruments identified overall acceptable performance of both dRVVT (Werfen solution) and APTT (non-Werfen solution) to enable harmonization of LA testing in our large network.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Testes de Coagulação Sanguínea/métodos , Humanos , Laboratórios , Tempo de Tromboplastina Parcial , Tempo de Protrombina/métodos
11.
J Thromb Haemost ; 20(4): 975-988, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35038779

RESUMO

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is a prothrombotic, immune-mediated adverse drug reaction associated with high rates of thrombosis-related morbidity and mortality caused by FcγRIIa-activating pathogenic antibodies to PF4-heparin. Procoagulant platelets are a platelet subset that promote thrombin generation, are clinically relevant in prothrombotic diseases, and are formed when platelet G-protein-coupled receptor (GPCR) and ITAM-linked receptors are co-stimulated. OBJECTIVES: We examined the procoagulant platelet response of healthy donors to platelet agonists in the presence of HIT plasma and determined the contribution of FcγRIIa. PATIENTS/METHODS: Our previously established flow cytometry-based procoagulant platelet assay was modified to incorporate plasma samples, performed using FcγRIIa-responsive donor platelets. Plasma samples were serotonin-release assay-confirmed HIT (HIT+), or negative on HIT screening. RESULTS: In response to GPCR stimulation, only HIT+ plasma produced a heparin-dependent sensitization that required active FcγRIIa. As a potential diagnostic tool, the procoagulant platelet assay achieved 98% accuracy in identifying clinically verified HIT when performed blinded to the diagnoses of a validation cohort. Samples inducing a higher procoagulant platelet response were more likely from patients with thrombotic complications. Thrombin stimulation markedly increased the procoagulant platelet response with HIT+ plasma that was heparin independent and only partially reversed by FcγRIIa blockade, possibly reflecting ongoing thrombotic risk after heparin cessation. CONCLUSIONS: We demonstrate that HIT plasma together with platelet agonists increased the procoagulant platelet proportions, which may contribute to thrombotic risk in HIT. Targeting procoagulant platelet activation may represent a novel treatment strategy. This assay may be a rapid, clinically relevant functional assay for accurately detecting pathological HIT antibodies.


Assuntos
Trombocitopenia , Trombose , Anticoagulantes/efeitos adversos , Plaquetas , Heparina/efeitos adversos , Humanos , Ativação Plaquetária , Fator Plaquetário 4 , Trombina , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico
12.
Sci Rep ; 11(1): 7975, 2021 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-33846433

RESUMO

Extracorporeal membrane oxygenation (ECMO) support has a high incidence of both bleeding and thrombotic complications. Despite clear differences in patient characteristics and pathologies between veno-venous (VV) and veno-arterial (VA) ECMO support, anticoagulation practices are often the same across modalities. Moreover, there is very little data on their respective coagulation profiles and comparisons of thrombin generation in these patients. This study compares the coagulation profile and thrombin generation between patients supported with either VV and VA ECMO. A prospective cohort study of patients undergoing VA and VV ECMO at an Intensive care department of a university hospital and ECMO referral centre. In addition to routine coagulation testing and heparin monitoring per unit protocol, thromboelastography (TEG), multiplate aggregometry (MEA), calibrated automated thrombinography (CAT) and von-Willebrand's activity (antigen and activity ratio) were sampled second-daily for 1 week, then weekly thereafter. VA patients had significantly lower platelets counts, fibrinogen, anti-thrombin and clot strength with higher d-dimer levels than VV patients, consistent with a more pronounced consumptive coagulopathy. Thrombin generation was higher in VA than VV patients, and the heparin dose required to suppress thrombin generation was lower in VA patients. There were no significant differences in total bleeding or thrombotic event rates between VV and VA patients when adjusted for days on extracorporeal support. VA patients received a lower median daily heparin dose 8500 IU [IQR 2500-24000] versus VV 28,800 IU [IQR 17,300-40,800.00]; < 0.001. Twenty-eight patients (72%) survived to hospital discharge; comprising 53% of VA patients and 77% of VV patients. Significant differences between the coagulation profiles of VA and VV patients exist, and anticoagulation strategies for patients of these modalities should be different. Further research into the development of tailored anticoagulation strategies that include the mode of ECMO support need to be completed.


Assuntos
Artérias/fisiologia , Coagulação Sanguínea/fisiologia , Oxigenação por Membrana Extracorpórea , Hemostasia/fisiologia , Trombina/metabolismo , Veias/fisiologia , Adulto , Anticoagulantes/farmacologia , Automação , Coagulação Sanguínea/efeitos dos fármacos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Fator Xa/metabolismo , Feminino , Hemorragia/etiologia , Hemostasia/efeitos dos fármacos , Heparina/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Tromboplastina Parcial , Tromboelastografia
15.
J Thromb Haemost ; 18(8): 1874-1883, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32311825

RESUMO

BACKGROUND: Patients with hemophilia B are increasingly treated with extended half-life (EHL) factor IX (FIX) concentrates. For the laboratory, introduction of these EHL concentrates presents a major challenge. To understand the variation in FIX activity levels, all available diagnostic assays need to be directly compared. METHODS: The ECAT, UKNEQAS, and RCPAQAP have collaboratively performed a global survey to evaluate the quality of FIX measurements using FIX deficient plasma samples spiked with recombinant FIX (rFIX), rFIXFP, rFIXFc, and N9-GP to levels at typical FIX trough (6 IU/dL) and peak levels (60 IU/dL). Participants were asked to use their routine protocols, using one-stage assays (OSA) or chromogenic assays (CA). RESULTS: In samples spiked with 6 IU/dL product, median (25%-75% range) FIX activity levels (OSA), were 8.0 IU/dL (7.0-9.2) for rFIX, 6.0 IU/dL (4.0-7.1) for rFIXFP, 6.6 IU/dL (5.5-8.0) for rFIXFc, and 4.9 IU/dL (3.5-8.4) for N9-GP. In samples spiked with 60 IU/dL, FIX activity levels measured (using OSA) was 63.0 IU/dL (59.9-67.0) for rFIX, 42.5 IU/dL (28.2-47.0) for rFIXFP, 50.0 IU/dL (45.0-55.0) for rFIXFc, and 34.0 IU/dL (24.8-67.5) for N9-GP. Considerable differences were observed between reagents for all samples. With CA, there was also quite some variation, but no differences between reagents. CONCLUSION: Large variation is observed in the measurement of FIX activity levels after administration of rFIX and EHL FIX products. For N9-GP, most silica-based assays show especially high levels. It is essential to standardize and improve reliability of measurements of these concentrates as diagnosis and treatment monitoring is based on these results.


Assuntos
Fator IX , Hemofilia B , Meia-Vida , Hemofilia B/diagnóstico , Hemofilia B/tratamento farmacológico , Humanos , Controle de Qualidade , Proteínas Recombinantes , Reprodutibilidade dos Testes
17.
Semin Thromb Hemost ; 45(1): 22-35, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30630206

RESUMO

The activated partial thromboplastin time (APTT) assay is a very common coagulation test, used for several reasons. The test is conventionally used for assessing the contact factor (intrinsic) pathway of blood coagulation, and thus for screening deficiencies in this pathway, most typically factors VIII, IX, and XI. The APTT is also sensitive to contact factor deficiencies, including factor XII, prekallikrein, and high-molecular-weight kininogen. The APTT may also be elevated in a variety of conditions, including liver disease, vitamin K deficiency, and disseminated intravascular coagulation. The APTT can also be used for monitoring unfractionated heparin (UFH) therapy, as well as for screening lupus anticoagulant (LA) or for assessing thrombosis risk. Which of these separate uses is important to a given laboratory or clinician depends on the laboratory and the clinical context. For example, UFH sensitivity is important in hospital-based laboratories, where UFH therapy is used, but not in hospital-based laboratories where low-molecular-weight heparin (LMWH) is largely employed or where UFH may be assessed by anti-factor Xa testing, or in private/community laboratories not associated with a hospital system. High sensitivity to (low levels of) factors VIII, IX, and XI is generally preferred, as their deficiencies are clinically significant. Also preferred, but not usually achieved, is low sensitivity to factor XII and other contact factors, as these deficiencies are usually asymptomatic. Nevertheless, a good knowledge of factor sensitivity is usually needed, if only to help explain the reasons for a prolonged APTT in a given patient, or whether factor testing or other investigation is required. A good working knowledge of reagents sensitivity to LA is also advisable, especially when the reagent is used as part of a LA test panel, or else as a "general-purpose screening reagent." The current report is aimed at providing some guidance around these questions, and is intended as a kind of "how to" guide, that will enable laboratories to assess APTT reagents in regard to their sensitivity to heparin, LA, and clotting factors. The report also provides some advice on generation of normal reference ranges, as well as solutions for troubleshooting prolonged APTTs, when performing factor testing or searching for inhibitors.


Assuntos
Fatores de Coagulação Sanguínea/metabolismo , Heparina/metabolismo , Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial/métodos , Humanos , Valores de Referência
18.
Methods Mol Biol ; 1646: 75-83, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28804819

RESUMO

The activated partial thromboplastin time (APTT) is a useful global assay for the assessment of the contact factor pathway of hemostasis and its inhibitors. The test is usually performed on fully automated analyzers using commercially prepared reagents. The three main clinical areas of interest are detection of factor deficiencies, detection of lupus anticoagulants and in the monitoring of therapy with unfractionated heparin. Methods are described here for assessing APTT reagents for their sensitivity to clotting time prolongation in each of these areas of interest.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea , Transtornos de Proteínas de Coagulação/sangue , Monitoramento de Medicamentos/métodos , Heparina/uso terapêutico , Inibidor de Coagulação do Lúpus/sangue , Tempo de Tromboplastina Parcial/métodos , Coagulação Sanguínea/efeitos dos fármacos , Transtornos de Proteínas de Coagulação/diagnóstico , Humanos , Indicadores e Reagentes
19.
Methods Mol Biol ; 1646: 85-90, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28804820

RESUMO

Mixing tests in coagulation studies allow the laboratory to correctly differentiate factor deficiency from inhibitors as the cause of a prolonged clotting time. This is important in terms of subsequent laboratory follow-up and clinical patient management. In this chapter, a suggested method of performing mixing tests is given, with procedures applying two different formulas for interpretation, the percent correction and the index of circulating anticoagulant.


Assuntos
Transtornos de Proteínas de Coagulação/sangue , Transtornos de Proteínas de Coagulação/diagnóstico , Tempo de Tromboplastina Parcial/métodos , Tempo de Protrombina/métodos , Coagulação Sanguínea , Humanos
20.
Methods Mol Biol ; 1646: 295-304, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28804837

RESUMO

Specific coagulation factor inhibitors, most notably to coagulation factor VIII, can develop in patients with hemophilia after exposure to replacement factor or as an acquired (autoimmune) event. Such inhibitors can be detected by a combination of prolonged coagulation screening tests, such as the activated partial thromboplastin time, plus a non-correcting mixing test. Non-correction may only be evident, or else may be extenuated, with incubation at 37 °C. The Bethesda assay for quantitation of inhibitor strength is based on a combination of mixing tests followed by specific factor assays.


Assuntos
Fator VIII/antagonistas & inibidores , Hemofilia A/sangue , Tempo de Tromboplastina Parcial/métodos , Autoanticorpos/sangue , Autoanticorpos/metabolismo , Coagulação Sanguínea , Testes Diagnósticos de Rotina , Fator VIII/análise , Fator VIII/metabolismo , Hemofilia A/diagnóstico , Hemofilia A/metabolismo , Humanos , Tempo de Protrombina