RESUMO
In our study, we designed and developed a glucose biosensor that operates without a battery or chip. This biosensor utilizes the principles of radio frequency (RF) to operate. For the construction of a glucose-sensitive interdigitated capacitor (IDC), a famous glucose-sensitive substance called phenylboronic acid (PBA) is combined with a polyvinyl chloride (PVC) and n,n-dimethylacetamide (DMAC) solution. According to the theory of radio frequency sensing, the resonance frequency shifts whenever there is a change in the capacitance of the glucose-sensitive IDC. This change is caused by the fluctuations in glucose concentrations. As far as we are aware, this is the first glucose sensor that employs the RF principle to detect changes in glucose solution concentrations using PBA as the principal glucose-sensitive material. The sensor can detect glucose levels with remarkable sensitivity, around 40.89 kHz/decade, and a broad dynamic range covering 10 µM to 1 M. Additionally, the designed biosensor has excellent linearity performance, with a value of around 0.988. The proposed glucose biosensor has several benefits: lightweight, inexpensive, easy to build, and an acceptable selectivity response. Our study concludes by comparing the proposed RF sensor's effectiveness to that of existing glucose sensors, which it outperforms.
RESUMO
Here, we designed and developed an organic field-effect transistor (OFET)-based gas sensor by applying solvatochromic dye (Nile red, NR) with twisted intramolecular charge-transfer (TICT) behavior depending on the polarity of the surrounding molecules, as an auxiliary NR sensing medium (aNR-SM). As a polar molecule approaches, intra-charge transfers from the donor diethylamine group to the ketone group occur in the NR molecule, resulting in the twisting of the donor functional group and thereby increasing its dipole moment. Using this characteristic, NR was applied as an auxiliary sensing medium to the OFET for detecting ammonia (NH3), a representative toxic gas. The Top-NR case, where the aNR-SM covers only the top of the organic semiconductor layer, showed the best gas sensing performance, and its response and recovery rates were improved by 46 and 94%, respectively, compared to the pristine case. More importantly, a sensitivity of 0.87 ± 0.045 ppm-1 % was measured, having almost perfect linearity (0.999) over the range of measured NH3 concentrations, which is the result of solving the saturation problem in the sensing characteristics of the OFET-based gas sensor. Our result not only improved the sensing performance of the OFET-based sensor but also made an important advance in that the reliability of the sensing performance was easily secured by applying solvatochromic and TICT behaviors of an auxiliary sensing medium.
RESUMO
The crystalline and morphological structures of polymer semiconducting films were controlled by selecting appropriate thermal properties of the polymeric chains, thereby improving polymer field-effect transistor (FET) performances. Poly(dioctyl-quaterthiophene-dioctyl-bithiazole) (PDQDB), comprising 5,5'-bithiazole and oligothiophene rings, was used as the basis for the polymer semiconductor studies. The Tg and Tm values of the thin-film state, rather than those of the bulk polymer state, were important in this study. A PDQDB film with a Tg of 101 °C in the thin-film state showed the highest maximum and average µFET values of 0.194 and 0.141 cm2 V-1 s-1, respectively, in an FET device at a post-processing temperature of 100 °C. On the other hand, relatively low average µFET values of 0.115, 0.098, and 0.079 cm2 V-1 s-1 were observed in FET devices prepared from PDQDB films with Tg values of 130, 165, and 180 °C, respectively, despite the dramatic increase in film crystallinity. With the variations in µFET, what we have noticed is that the standard deviations of the measured µFET values varied with the Tg values: 36.0% for the Tg = 165 °C film and 51.1% for the Tg = 180 °C film, indicating that the organic field-effect transistors performances were not uniform. These results were closely related to nano- and microscale nonuniformity in the PDQDB film structure in the presence of excessively activated grain structures. These variations were correlated with the crystalline and morphological structures of the PDQDB films prepared under various processing conditions.
RESUMO
In this study, we propose a highly sensitive multichannel pH sensor that is based on an optical-fiber pulse width modulation (PWM) technique. According to the optical-fiber PWM method, the received sensing signal's pulse width changes when the optical-fiber pH sensing-element of the array comes into contact with pH buffer solutions. The proposed optical-fiber PWM pH-sensing system offers a linear sensing response over a wide range of pH values from 2 to 12, with a high pH-sensing ability. The sensitivity of the proposed pH sensor is 0.46 µs/pH, and the correlation coefficient R² is approximately 0.997. Additional advantages of the proposed optical-fiber PWM pH sensor include a short/fast response-time of about 8 s, good reproducibility properties with a relative standard deviation (RSD) of about 0.019, easy fabrication, low cost, small size, reusability of the optical-fiber sensing-element, and the capability of remote sensing. Finally, the performance of the proposed PWM pH sensor was compared with that of potentiometric, optical-fiber modal interferometer, and optical-fiber Fabry-Perot interferometer pH sensors with respect to dynamic range width, linearity as well as response and recovery times. We observed that the proposed sensing systems have better sensing abilities than the above-mentioned pH sensors.
RESUMO
In this paper, we propose a temperature/thermal sensor that contains a Rhodamine-B sensing membrane. We applied two different sensing methods, namely, fiber-optic pulse width modulation (PWM) and an interdigitated capacitor (IDC)-based temperature sensor to measure the temperature from 5 °C to 100 °C. To the best of our knowledge, the fiber-optic PWM-based temperature sensor is reported for the first time in this study. The proposed fiber-optic PWM temperature sensor has good sensing ability; its sensitivity is ~3.733 mV/°C. The designed temperature-sensing system offers stable sensing responses over a wide dynamic range, good reproducibility properties with a relative standard deviation (RSD) of ~0.021, and the capacity for a linear sensing response with a correlation coefficient of R² ≈ 0.992 over a wide sensing range. In our study, we also developed an IDC temperature sensor that is based on the capacitance variation principle as the IDC sensing element is heated. We compared the performance of the proposed temperature-sensing systems with different fiber-optic temperature sensors (which are based on the fiber-optic wavelength shift method, the long grating fiber-optic Sagnac loop, and probe type fiber-optics) in terms of sensitivity, dynamic range, and linearity. We observed that the proposed sensing systems have better sensing performance than the above-mentioned sensing system.
RESUMO
In this paper, an electronic tongue/taste sensor array containing different interdigitated capacitor (IDC) sensing elements to detect different types of tastes, such as sweetness (glucose), saltiness (NaCl), sourness (HCl), bitterness (quinine-HCl), and umami (monosodium glutamate) is proposed. We present for the first time an IDC electronic tongue using sensing membranes containing solvatochromic dyes. The proposed highly sensitive (30.64 mV/decade sensitivity) IDC electronic tongue has fast response and recovery times of about 6 s and 5 s, respectively, with extremely stable responses, and is capable of linear sensing performance (R² ≈ 0.985 correlation coefficient) over the wide dynamic range of 1 µM to 1 M. The designed IDC electronic tongue offers excellent reproducibility, with a relative standard deviation (RSD) of about 0.029. The proposed device was found to have better sensing performance than potentiometric-, cascoded compatible lateral bipolar transistor (C-CLBT)-, Electronic Tongue (SA402)-, and fiber-optic-based taste sensing systems in what concerns dynamic range width, response time, sensitivity, and linearity. Finally, we applied principal component analysis (PCA) to distinguish between various kinds of taste in mixed taste compounds.
Assuntos
Nariz Eletrônico , Paladar , Corantes , Glucose , Reprodutibilidade dos Testes , LínguaRESUMO
In this paper, we proposed an interdigitated capacitor (IDC)-based glucose biosensor to measure different concentrations of glucose from 1 µM to 1 M. We studied four different types of solvatochromic dyes: Auramine O, Nile red, Rhodamine B, and Reichardt's dye (R-dye). These dyes were individually incorporated into a polymer [polyvinyl chloride (PVC)] and N,N-Dimethylacetamide (DMAC) solution to make the respective dielectric/sensing materials. To the best of our knowledge, we report for the first time an IDC glucose biosensing system utilizing a solvatochromic-dye-containing sensing membrane. These four dielectric or sensing materials were individually placed into the interdigitated electrode (IDE) by spin coating to make four IDC glucose biosensing elements. The proposed IDC glucose biosensor has a high sensing ability over a wide dynamic range and its sensitivity was about 23.32 mV/decade. It also has fast response and recovery times of approximately 7 s and 5 s, respectively, excellent reproducibility with a standard deviation of approximately 0.023, highly stable sensing performance, and real-time monitoring capabilities. The proposed IDC glucose biosensor was compared with an IDC, potentiometric, FET, and fiber-optic glucose sensor with respect to response time, dynamic range width, sensitivity, and linearity. We observed that the designed IDC glucose biosensor offered excellent performance.
Assuntos
Técnicas Biossensoriais/métodos , Glucose/análise , Corantes/química , EletrodosRESUMO
In this study, we designed and developed an interdigitated capacitor (IDC)-based taste sensor array to detect different taste substances. The designed taste sensing array has four IDC sensing elements. The four IDC taste sensing elements of the array are fabricated by incorporating four different types of lipids into the polymer, dioctyl phenylphosphonate (DOPP) and tetrahydrofuran (THF) to make the respective dielectric materials that are individually placed onto an interdigitated electrode (IDE) via spin coating. When the dielectric material of an IDC sensing element comes into contact with a taste substance, its dielectric properties change with the capacitance of the IDC sensing element; this, in turn, changes the voltage across the IDC, as well as the output voltage of each channel of the system. In order to assess the effectiveness of the sensing system, four taste substances, namely sourness (HCl), saltiness (NaCl), sweetness (glucose) and bitterness (quinine-HCl), were tested. The IDC taste sensor array had rapid response and recovery times of about 12.9 s and 13.39 s, respectively, with highly stable response properties. The response property of the proposed IDC taste sensor array was linear, and its correlation coefficient R2 was about 0.9958 over the dynamic range of the taste sensor array as the taste substance concentration was varied from 1 µM to 1 M. The proposed IDC taste sensor array has several other advantages, such as real-time monitoring capabilities, high sensitivity 45.78 mV/decade, good reproducibility with a standard deviation of about 0.029 and compactness, and the circuitry is based on readily available and inexpensive electronic components. The proposed IDC taste sensor array was compared with the potentiometric taste sensor with respect to sensitivity, dynamic range width, linearity and response time. We found that the proposed IDC sensor array has better performance. Finally, principal component analysis (PCA) was applied to discriminate different types of taste of the mixed taste substances.
RESUMO
In this paper, we propose a volatile organic compound (VOC) gas sensing system with high sensitivity and a wide dynamic range that is based on the principle of the heterodyne frequency modulation method. According to this method, the time period of the sensing signal shift when Nile Red containing a VOC-sensitive membrane of a fiber-optic sensing element comes into contact with a VOC. This sensing membrane produces strong, fast and reversible signals when exposed to VOC gases. The response and recovery times of the proposed sensing system were less than 35 s, and good reproducibility and accuracy were obtained.
Assuntos
Tecnologia de Fibra Óptica/instrumentação , Gases/análise , Microquímica/instrumentação , Refratometria/instrumentação , Compostos Orgânicos Voláteis/análise , Desenho de Equipamento , Análise de Falha de Equipamento , Gases/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Compostos Orgânicos Voláteis/químicaRESUMO
In this paper, we proposed a new type high sensitive volatile organic compounds (VOCs) gas sensor array that is based on the pulse width modulation technique. Four different types of solvatochromic dyes and two different types of polymers, were used to make the five different types of sensing membranes. These were deposited on the five side-polished optical fibers by a spin coater to make the five different sensing elements of the array. In order to ascertain the effectiveness of the sensors, five VOC gases were tested. Finally, principal component analysis (PCA) has been used to discriminates different types of VOCs.