Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Interact Cardiovasc Thorac Surg ; 34(6): 990-998, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34957518

RESUMO

OBJECTIVES: Catheter ablation of long-standing persistent atrial fibrillation (LSPAF) remains challenging, with suboptimal success rates obtained following multiple procedures. Thoracoscopic ablation has shown effective at creating transmural lesions around the pulmonary veins and box; however, long-term rhythm follow-up data are lacking. This study aims, for the first time, to assess the long-term outcomes of thoracoscopic pulmonary vein and box ablation in LSPAF. METHODS: Rhythm follow-up consisted of continuous rhythm monitoring using implanted loop recorders or 24-h Holter recordings. Rhythm status and touch-up interventions were assessed up to 5 years. RESULTS: Seventy-seven patients with symptomatic LSPAF underwent thoracoscopic ablation in 2 centres. Freedom from atrial arrhythmias at 5 years was 50% following a single thoracoscopic procedure and 68% allowing endocardial touch-up procedures (performed in 21% of patients). The mean atrial fibrillation burden in patients with continuous monitoring was reduced from 100% preoperatively to 0.1% at the end of the blanking period and 8.0% during the second year. Antiarrhythmic drug use decreased from 49.4% preoperative to 12.1% and 14.3% at 2 and 5 years, respectively (P < 0.001). Continuous rhythm monitoring resulted in higher recurrence detection rates compared to 24-h Holter monitoring at 2-year follow-up (hazard ratio: 6.5, P = 0.003), with comparable recurrence rates at 5-year follow-up. CONCLUSIONS: Thoracoscopic pulmonary vein and box isolation are effective in long-term restoration of sinus rhythm in LSPAF, especially when complemented by endocardial touch-up procedures, as demonstrated by the 68% freedom rate at 5 years. Continuous rhythm monitoring revealed earlier, but not more numerous documentation of recurrences at 5-year follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Seguimentos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Toracoscopia/efeitos adversos , Toracoscopia/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA