Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
AJR Am J Roentgenol ; 208(3): W92-W100, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28026201

RESUMO

OBJECTIVE: The purpose of this study is to evaluate the roles of self-directed learning and continual feedback in the learning curve for tumor detection by novice readers of prostate MRI. MATERIALS AND METHODS: A total of 124 prostate MRI examinations classified as positive (n = 52; single Prostate Imaging Reporting and Data System [PI-RADS] category 3 or higher lesion showing Gleason score ≥ 7 tumor at MRI-targeted biopsy) or negative (n = 72; PI-RADS category 2 or lower and negative biopsy) for detectable tumor were included. These were divided into four equal-sized batches, each with matching numbers of positive and negative examinations. Six second-year radiology residents reviewed examinations to localize tumors. Three of the six readers received feedback after each examination showing the preceding case's solution. The learning curve, plotting accuracy over time, was assessed by the Akaike information criterion (AIC). Logistic regression and mixed-model ANOVA were performed. RESULTS: For readers with and without feedback, the learning curve exhibited an initial rapid improvement that slowed after 40 examinations (change in AIC > 0.2%). Accuracy improved from 58.1% (batch 1) to 71.0-75.3% (batches 2-4) without feedback and from 58.1% to 72.0-77.4% with feedback (p = 0.027-0.046), without a difference in the extent of improvement (p = 0.800). Specificity improved from 53.7% to 68.5-81.5% without feedback and from 55.6% to 74.1-81.5% with feedback (p = 0.006-0.010), without a difference in the extent of improvement (p = 0.891). Sensitivity improved from 59.0-61.5% (batches 1-2) to 71.8-76.9% (batches 3-4) with feedback (p = 0.052), though did not improve without feedback (p = 0.602). Sensitivity for transition zone tumors exhibited larger changes (p = 0.024) with feedback than without feedback. Sensitivity for peripheral zone tumors did not improve in either group (p > 0.3). Reader confidence increased only with feedback (p < 0.001). CONCLUSION: The learning curve in prostate tumor detection largely reflected self-directed learning. Continual feedback had a lesser effect. Clinical prostate MRI interpretation by novice radiologists warrants caution.


Assuntos
Avaliação Educacional/estatística & dados numéricos , Internato e Residência/estatística & dados numéricos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Radiologia/educação , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica/estatística & dados numéricos , Humanos , Curva de Aprendizado , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , New York , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ensino/estatística & dados numéricos
2.
Abdom Radiol (NY) ; 42(1): 290-297, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27576605

RESUMO

PURPOSE: To compare image quality and diagnostic performance for detecting local recurrence (LR) of prostate cancer after radical prostatectomy (RP) between standard dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and a high spatiotemporal resolution, continuously acquired Golden-angle RAdial Sparse Parallel acquisition employing compressed sensing reconstruction ("GRASP"). METHODS: A search was conducted for prostate MRI examinations performed in patients with PSA ≥0.2 ng/mL after RP in whom follow-up evaluation allowed classification as positive (≥50% PSA reduction after pelvic radiation or positive biopsy) or negative (<50% PSA reduction after pelvic radiation; spontaneous PSA normalization) for LR, yielding 13 patients with standard DCE (11 LR+) and 12 with GRASP (10 LR+). Standard DCE had voxel size 3.0 × 1.9 × 1.9 mm and temporal resolution 5.5 s. GRASP had voxel size 1.0 × 1.1 × 1.1 cm and was retrospectively reconstructed at 2.3 s resolution. Two radiologists evaluated DCE sequences for image quality measures (1-5 scale) and the presence of LR. RESULTS: GRASP achieved higher scores than standard DCE from both readers (p < 0.001-0.136) for anatomic clarity (R1: 4.4 ± 0.8 vs. 2.8 ± 0.67 R2: 4.8 ± 0.5 vs. 3.2 ± 0.6), sharpness (3.6 ± 0.9 vs. 2.5 ± 0.7; 4.6 ± 0.5 vs. 2.6 ± 0.5), confidence in interpretation (3.8 ± 0.8 vs. 3.1 ± 0.9; 3.8 ± 1.0 vs. 3.1 ± 1.2), and conspicuity of detected lesions (4.7 ± 0.5 vs. 3.8 ± 1.1; 4.5 ± 0.5 vs. 3.8 ± 1.0). For detecting LR, GRASP also achieved higher sensitivity (70% vs. 36%; 80% vs. 45%), specificity (R1 and R2: 100% vs. 50%), and accuracy (75% vs. 38%; 83% vs. 46%) for both readers. CONCLUSION: Although requiring larger studies, high spatiotemporal resolution GRASP achieved substantially better image quality and diagnostic performance than standard DCE for detecting LR in patients with elevated PSA after prostatectomy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Prostatectomia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Clin Nucl Med ; 42(1): e58-e60, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27775934

RESUMO

Interpretation of iodine I whole-body scintigraphy can be challenging, as there are many nonpathologic findings that may present with increased radiotracer uptake. Radiotracer uptake has been reported in the literature involving the salivary glands, thymus, renal cysts, skin contamination, and other benign etiologies. We present the case of an incidental right wrist ganglion cyst demonstrating persistent increased uptake on I whole-body scintigraphy.


Assuntos
Cistos Glanglionares/diagnóstico por imagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Imagem Corporal Total , Adulto , Radioisótopos de Cobalto , Humanos , Achados Incidentais , Radioisótopos do Iodo , Imageamento por Ressonância Magnética , Masculino , Compostos Radiofarmacêuticos , Punho/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA