Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
Can J Cardiol ; 40(4): 576-584, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38007219

RESUMO

BACKGROUND: The EARLY-AF (NCT02825979), STOP AF First (NCT03118518), and Cryo-FIRST (NCT01803438) randomised controlled trials (RCTs) demonstrated that cryoballoon pulmonary vein isolation reduces atrial fibrillation (AF) recurrence compared with antiarrhythmic drugs (AADs) in patients with symptomatic paroxysmal atrial fibrillation (PAF). The present study developed a cost-effectiveness model (CEM) of first-line cryoablation compared with first-line AADs for PAF, from the Canadian health care payer's perspective. METHODS: Data from the 3 RCTs were analysed to estimate key CEM parameters. The model structure used a decision tree for the first 12 months and a Markov model with a 3-month cycle length for the remaining lifetime time horizon. Costs were set at 2023 Canadian dollars, health benefits were expressed as quality-adjusted life years (QALYs), and both were discounted 3% annually. Probabilistic sensitivity analysis (PSA) considered parameter uncertainty. RESULTS: The statistical analysis estimated that first-line cryoablation generates a 47% reduction (P < 0.001) in the rate of AF recurrence, a 73% reduction in the rate of subsequent ablation (P < 0.001), and a 4.3% (P = 0.025) increase in health-related quality of life, compared with first-line AADs. The PSA indicates that an individual treated with first-line cryoablation accrues less costs (-$3,862) and more QALYs (0.19) compared with first-line AADs. Cryoablation is cost-saving in 98.4% of PSA iterations and has a 99.9% probability of being cost-effective at a cost-effectiveness threshold of $50,000 per QALY gained. Cost-effectiveness results were robust to changes in key model parameters. CONCLUSIONS: First-line cryoballoon ablation is cost-effective when compared with AADs for patients with symptomatic PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Análise Custo-Benefício , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Canadá/epidemiologia , Resultado do Tratamento , Recidiva
4.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37799799

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

5.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37283271

RESUMO

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Criança , Humanos , Fascículo Atrioventricular , Resultado do Tratamento , Doença do Sistema de Condução Cardíaco , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Eletrocardiografia/métodos
6.
Can J Diabetes ; 47(4): 352-358, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37074240

RESUMO

OBJECTIVES: Diabetes has been reported to be associated with an increased risk of death among patients with COVID-19. However, the available studies lack detail on COVID-19 illness severity and measurement of relevant comorbidities. METHODS: We conducted a multicentre, retrospective cohort study of patients 18 years of age and older who were hospitalized with COVID-19 between January 1, 2020, and November 30, 2020, in Ontario, Canada, and Copenhagen, Denmark. Chart abstraction emphasizing comorbidities and disease severity was performed by trained research personnel. The association between diabetes and death was measured using Poisson regression. The main outcome measure was in-hospital 30-day risk of death. RESULTS: Our study included 1,133 hospitalized patients with COVID-19 in Ontario and 305 in Denmark, of whom 405 and 75 patients, respectively, had pre-existing diabetes. In both Ontario and Denmark, patients with diabetes were more likely to be older; have chronic kidney disease, cardiovascular disease, and higher troponin levels; and be receiving antibiotics, when compared with adults without diabetes. In Ontario, 24% (n=96) of adults with diabetes died compared with 15% (n=109) of adults without diabetes. In Denmark, 16% (n=12) of adults with diabetes died in hospital compared with 13% (n=29) of those without diabetes. In Ontario, the crude mortality ratio among patients with diabetes was 1.60 (95% confidence interval [CI], 1.24 to 2.07) and in the adjusted regression model it was 1.19 (95% CI, 0.86 to 1.66). In Denmark, the crude mortality ratio among patients with diabetes was 1.27 (95% CI, 0.68 to 2.36) and in the adjusted model it was 0.87 (95% CI, 0.49 to 1.54). Meta-analysis of the 2 rate ratios from each region resulted in a crude mortality ratio of 1.55 (95% CI, 1.22 to 1.96) and an adjusted mortality ratio of 1.11 (95% CI, 0.84 to 1.47). CONCLUSION: The presence of diabetes was not strongly associated with in-hospital COVID-19 mortality independent of illness severity and other comorbidities.


Assuntos
COVID-19 , Diabetes Mellitus , Humanos , Adulto , Adolescente , Estudos de Coortes , Ontário/epidemiologia , Estudos Retrospectivos , SARS-CoV-2 , Fatores de Risco , Hospitalização , Diabetes Mellitus/epidemiologia , Mortalidade Hospitalar , Dinamarca/epidemiologia
7.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
8.
J Hosp Med ; 17(10): 793-802, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36040111

RESUMO

BACKGROUND: There is wide variation in mortality among patients hospitalized with COVID-19. Whether this is related to patient or hospital factors is unknown. OBJECTIVE: To compare the risk of mortality for patients hospitalized with COVID-19 and to determine whether the majority of that variation was explained by differences in patient characteristics across sites. DESIGN, SETTING, AND PARTICIPANTS: An international multicenter cohort study of hospitalized adults with laboratory-confirmed COVID-19 enrolled from 10 hospitals in Ontario, Canada and 8 hospitals in Copenhagen, Denmark between January 1, 2020 and November 11, 2020. MAIN OUTCOMES AND MEASURES: Inpatient mortality. We used a multivariable multilevel regression model to compare the in-hospital mortality risk across hospitals and quantify the variation attributable to patient-level factors. RESULTS: There were 1364 adults hospitalized with COVID-19 in Ontario (n = 1149) and in Denmark (n = 215). In Ontario, the absolute risk of in-hospital mortality ranged from 12.0% to 39.8% across hospitals. Ninety-eight percent of the variation in mortality in Ontario was explained by differences in the characteristics of the patients. In Denmark, the absolute risk of inpatients ranged from 13.8% to 20.6%. One hundred percent of the variation in mortality in Denmark was explained by differences in the characteristics of the inpatients. CONCLUSION: There was wide variation in inpatient COVID-19 mortality across hospitals, which was largely explained by patient-level factors, such as age and severity of presenting illness. However, hospital-level factors that could have affected care, including resource availability and capacity, were not taken into account. These findings highlight potential limitations in comparing crude mortality rates across hospitals for the purposes of reporting on the quality of care.


Assuntos
COVID-19 , Adulto , Estudos de Coortes , Mortalidade Hospitalar , Hospitalização , Humanos , Ontário/epidemiologia
9.
J Interv Card Electrophysiol ; 65(2): 481-489, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35739438

RESUMO

BACKGROUND: Transseptal puncture to achieve left atrial access is necessary for many cardiac procedures, including atrial fibrillation ablation. More recently, there has been an increasing need for left atrial access using large caliber sheaths, which increases risk of perforation associated with the initial advancement into the left atrium. We compared the effectiveness of a radiofrequency needle-based transseptal system versus conventional needle for transseptal access. METHODS: This prospective controlled trial randomized 161 patients with symptomatic paroxysmal atrial fibrillation undergoing cryoballoon pulmonary vein isolation to transseptal access with a commercially available transseptal system (radiofrequency needle plus stiff pigtail wire; RF + Pigtail group) versus conventional transseptal access (standard group). The primary outcome was time required for left atrial access. Secondary outcomes included failure of the assigned transseptal system, radiation exposure, and complications. RESULTS: The median transseptal puncture time was significantly shorter using the radiofrequency needle plus stiff pigtail wire transseptal system compared with conventional transseptal (840 ± 323 vs. 956 ± 407 s, P = 0.0489). Compared to conventional transseptal puncture, fewer transseptal attempts were required (1.0 ± 0.5 RF applications vs. 1.3 ± 0.8 mechanical punctures, P = 0.0123) and the fluoroscopy time was significantly shorter (72.0 [IQR 48.0, 129.0] vs. 93.0 [IQR 60.0, 171.0] s, P = 0.0490) with the radiofrequency needle plus stiff pigtail wire transseptal system. Failure to achieve transseptal LA access with the assigned system was rarely observed (1.3% vs. 5.7%, P = 0.2192). There were no procedural complications observed with either system. CONCLUSIONS: The use of a radiofrequency needle plus stiff pigtail wire resulted in shorter time to left atrial access and reduced fluoroscopy time compared to left atrial access using conventional transseptal equipment. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT03199703.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Estudos Prospectivos , Punções , Resultado do Tratamento
10.
Heart Rhythm ; 19(9): 1484-1490, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35562056

RESUMO

BACKGROUND: The reported success rate of His-bundle pacing (HBP) in patients with infranodal atrioventricular (AV) conduction disease is only 52%-76%. The success rate of left bundle branch area pacing (LBBAP) in this cohort is not well studied. OBJECTIVE: The purpose of this study was to evaluate the feasibility, safety, and electrophysiological characteristics of LBBAP in patients with AV conduction disease. METHODS: Patients with AV conduction disease referred for pacemaker implantation at 2 centers between February 2019 and June 2021 were considered for LBBAP. Baseline demographic characteristics, procedural success rates, electrophysiological parameters, and complications were assessed. RESULTS: LBBAP was successful in 340 of 364 patients (93%). Mean age was 72 ± 13 years, and mean follow-up was 331 ± 244 days. Pacing indications were Mobitz I in 27 patients (7%), Mobitz II or 2:1 AV block or high-grade AV block in 94 patients (26%), complete heart block in 199 patients (55%), and sick sinus syndrome with isolated bundle branch block in 44 patients (12%). Left bundle branch block and right bundle branch block were present in 57 patients (16%) and 140 patients (38%), respectively. Procedural success rates did not differ between indications (92.6%, 93.6%, 92.9%, and 95%, respectively) or between patients with narrow (<120 ms) vs wide QRS (≥120 ms). Mean LBBAP threshold was 0.77 ± 0.34 V at 0.4 ms at implant and remained stable during follow-up. There were 4 (1.2%) acute LBBAP lead dislodgments. CONCLUSION: LBBAP is safe and feasible with high success rates for patients with AV conduction disease. In contrast to HBP, LBBAP success rates remain high over the entire spectrum of AV conduction disease, and lead parameters remain stable during follow-up.


Assuntos
Bloqueio Atrioventricular , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/terapia , Fascículo Atrioventricular , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Eletrocardiografia , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
CJC Open ; 3(10): 1310-1312, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34888512

RESUMO

Leadless pacemakers have become an effective alternative to conventional transvenous pacemakers to prevent the risk of lead failure, pocket complications, and iatrogenic tricuspid regurgitation. The current transcatheter approach for tricuspid valve repair can limit the implantation of these devices, unless the procedure is performed with appropriate image guidance. We present the case of a patient with severe tricuspid regurgitation secondary to pacemaker lead impingement who, despite the implantation of a tricuspid clip, received a leadless pacemaker. The procedure was successfully guided by transthoracic echocardiography, an alternative to transesophageal or intracardiac echocardiography.


Les stimulateurs cardiaques sans électrodes sont devenus une solution de rechange efficace aux stimulateurs transveineux classiques pour prévenir le risque de défaillance des électrodes, les complications liées à la loge et la régurgitation tricuspidienne iatrogène. L'approche actuelle de réparation de la valve tricuspide par cathétérisme peut empêcher l'implantation de ces dispositifs, à moins que l'intervention ne soit réalisée avec un guidage par image approprié. Nous présentons le cas d'un patient ayant une régurgitation tricuspidienne grave consécutive à la compression des électrodes d'un stimulateur cardiaque qui, malgré l'implantation d'un clip tricuspide, a reçu un stimulateur cardiaque sans électrodes. L'intervention a été guidée avec succès au moyen d'une échocardiographie par voie transthoracique, une solution de rechange à l'échocardiographie transœsophagienne ou intracardiaque.

12.
J Atr Fibrillation ; 14(2): 20200477, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34950370

RESUMO

OBJECTIVE: To evaluate the feasibility, safety, and clinical efficacy of non-fluoroscopic radiofrequency catheter ablation of atrial fibrillation (AF) in comparison to traditional fluoroscopy-guided ablation in a local Canadian community cohort. METHODS: We retrospectively studied consecutive patients with paroxysmal and persistent AF undergoing pulmonary vein isolation (PVI) guided by intracardiac echocardiography (ICE) and Carto system (CartoSound module). ICE-guided PVI without fluoroscopy (Zero-fluoro group) was performed in 116 patients, and conventional fluoroscopy-guided PVI (Traditional group) was performed in 131 patients. RESULTS: Two hundred and forty-seven patients with AF (60.7% male; mean age: 62.2 ± 10.6 years; paroxysmal AF =63.1%) who underwent PVI were studied. Mean procedure times were similar between both groups (136.8±33.4 minutes in the zero-fluoro group vs. 144.3±44.9 minutes in the traditional group; p=0.2). Acute PVI was achieved in all patients. Survival from early AF recurrence was 85% and 81% in the zero-fluoro and traditional groups, respectively (p = 0.06). Survival from late AF recurrence (12-months) between the zero-fluoro and traditional groups was also similar (p=0.1). Moreover, there were no significant differences between complication rates, including hematoma (p = 0.2) and tamponade (p = 1),between both groups. CONCLUSIONS: Zero-fluoroscopy ICE and CartoSound-guided AF ablation may be safe and feasible in patients undergoing PVI compared to conventional fluoroscopy-guided ablation.

13.
J Cardiovasc Electrophysiol ; 32(9): 2515-2521, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34245466

RESUMO

OBJECTIVES: To evaluate the safety and feasibility of left bundle branch area pacing (LBBAP) in patients with valvular interventions. METHODS: Eighty-four patients were included in this study. All patients underwent recent surgical or percutaneous valvular interventions. LBBAP was attempted in all patients. Implant success rates, peri- and postprocedure electrocardiogram, pacing parameters, and complications were assessed at implant, and during follow-up. RESULTS: LBBAP implantation was successful in 80/84 (95%) patients. Mean age was 74.1 ± 13.8 years and 56% patients were male. Prior valvular replacements included: percutaneous aortic (26), surgical aortic (36), combined surgical aortic plus mitral (6), MVR (10), tricuspid (1), and pulmonic (1). Average LVEF was 52.6 ± 11%. Majority of patients underwent LBBAP due to atrioventricular block (76%) and sinus node disease (13%). Total procedure duration was 74.1 ± 12.5 min and fluoroscopic duration was 9.7 ± 6.8 min. Pacing parameters were stable during follow-up period of 10.0 ± 6.3 months. Pacing QRS duration was significantly narrower than baseline QRS duration (131.5 ± 31.4 ms vs. 114.3 ± 13.7 ms, p < .001, respectively). No acute complications were observed. Mean follow-up was 10.0 ± 6.3 months (median: 8.4 months, min: 1 and max: 24 months). During follow-up, there were three device infections and two patients had loss of LBBA capture within 1 month of implant. CONCLUSIONS: LBBAP is a feasible and safe pacing modality in patients with prior interventions for valvular heart disease.


Assuntos
Bloqueio Atrioventricular , Septo Interventricular , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Eletrocardiografia , Estudos de Viabilidade , Sistema de Condução Cardíaco , Humanos , Masculino , Pessoa de Meia-Idade
15.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
16.
JACC Clin Electrophysiol ; 6(14): 1773-1782, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33357573

RESUMO

OBJECTIVES: This study sought to evaluate the safety and feasibility of conduction system pacing by performing left bundle branch area pacing (LBBAP). BACKGROUND: There are limited data from single centers showing that LBBAP may circumvent the technical and electrophysiological challenges encountered with His bundle pacing. METHODS: Patients referred for pacemaker implantation at 2 centers between February 1, 2019, and March 31, 2020, were considered for LBBAP. LBBAP was performed by implanting a lumen-less, exposed helix lead approximately 2 cm distal to the His bundle and deep into the septum using a specialized delivery sheath. Implant success rates, complications, and electrophysiological parameters were assessed. RESULTS: LBBAP was successful in 305 of 341 patients (89%). Mean age was 72 ± 12 years; 45% were women; and 39% had QRS duration (QRSd) >130 ms, 22% right bundle branch block, 11% left bundle branch block, and 6% intraventricular conduction defect. Pacing indications were sinus node dysfunction in 28.7%, atrioventricular block in 52.5%, cardiac resynchronization therapy in 8.8%, and refractory atrial fibrillation in 10% of patients. Procedural duration was 74.7 ± 34 min and fluoroscopic time was 10.4 ± 8.1 min. The mean baseline QRSd and paced QRSd in the overall cohort was 114 ± 29.8 ms versus 112 ± 11.7 ms (p < 0.001) and in patients with infra-Hisian disease was 144.5 ± 19 ms versus 115 ± 12 ms (p < 0.001), respectively. Mean left ventricular activation time was 71.7 ± 11 ms at high output and 74.7 ± 11 ms at low output. LBB potentials were noted in 41% patients. Pacing threshold and R waves were 0.74 ± 0.3 V at 0.4 ms and 10.7 ± 4.9 mV at time of implantation and were stable at 1-, 3-, 6-, and 12-month follow-ups. The only major complications were 3 LBBAP lead dislodgements, 2 within 24 h and 1 at 2 weeks. CONCLUSIONS: LBBA pacing is safe, feasible, and a reliable alternative to His bundle pacing for providing physiological pacing. Randomized controlled studies are needed to confirm the safety, feasibility, and clinical outcomes of LBBAP.


Assuntos
Terapia de Ressincronização Cardíaca , Eletrocardiografia , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Europace ; 22(7): 1017-1025, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32531030

RESUMO

AIMS: Atrial fibrillation (AF) significantly impairs patients' quality of life (QOL). We performed this study to investigate the effect of AF-ablation success and atrial fibrillation burden (AFB) on QOL measures. METHODS AND RESULTS: Overall, 230 patients with paroxysmal AF refractory to antiarrhythmic drugs were enrolled and underwent ablation in a multicentre, prospective cohort. Electrocardiogram, 48-h Holter, Canadian Cardiovascular Society Severity of Atrial Fibrillation (CCS-SAF), short form-12 (SF-12), and Atrial Fibrillation Effect on Quality of life (AFEQT) scales were used to assess patients. Atrial fibrillation burden was defined as total duration of AF during the month prior to each visit (h/month). The change in AFB was calculated as the difference between the month prior to the 12-month post-ablation and the baseline pre-ablation. The Minimal Clinically Important Difference (MCID) was considered as a 19-point change for AFEQT and 3-5-point change for SF-12 scores. There was significant rise in the AFEQT and SF12 and decrease in CCS-SAF score post-AF ablation; however, the magnitude of these changes was greater in patients without AF recurrence (P < 0.05). The QOL score that best differentiated patients with and without recurrence was AFEQT, while, CCS-SAF was the most specific score. Patients with AFB decrease >19 h/month had significantly greater change in QOL scores. Atrial fibrillation burden < 24 h/month at 12-months post-ablation was associated with significant changes in QOL and CCS-SAF when adjusting for baseline scores and other covariates. These changes were consistent with the MCID of these measures. CONCLUSION: Patients experience significant improvements in QOL post-ablation, which correlate with a decrease in AFB despite ongoing brief recurrences of AF. CLINICAL TRIAL REGISTRATION: NCT01562912. https://www.clinicaltrials.gov/ct2/show/NCT01562912? term=capcost&rank=1.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Humanos , Estudos Prospectivos , Qualidade de Vida , Recidiva , Resultado do Tratamento
19.
J Med Case Rep ; 13(1): 239, 2019 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-31375131

RESUMO

BACKGROUND: Pseudoaneurysm of thoracic aorta as a complication of blunt trauma to the chest, can present with a variety of symptoms due to mass compression effect. Here we report the first pseudoaneurysm of thoracic aorta presenting with chronic cough and inappropriate sinus tachycardia. The purpose of this case report is to highlight pseudoaneurysm of thoracic aorta as a rare differential diagnosis for inappropriate sinus tachycardia. CASE PRESENTATION: Here we report a case of 29-year-old white woman, a nurse, with history of a motor vehicle accident. She initially presented to medical attention with inappropriate sinus tachycardia 2 years following the motor vehicle accident during her pregnancy. Six years later she underwent sinoatrial node modification after failing a number of medications. Days prior to the ablation she developed a mild cough which became constant within a week following ablation. A computed tomography scan of her chest performed as part of a workup revealed an outpouching of the inferomedial aspect of the aortic arch, which was compressing her left main bronchus. She underwent arch repair surgery and recovered without complications. Four years later she presented with significant symptomatic sinus bradycardia requiring pacemaker placement. CONCLUSIONS: This is the first reported case of thoracic pseudoaneurysm of aorta presenting with inappropriate sinus tachycardia due to compression of the vagal nerve and cough as a result of the left main bronchus compressive effect; it highlights the importance of considering structural abnormalities in a differential diagnosis of inappropriate sinus tachycardia before any interventions.


Assuntos
Falso Aneurisma/diagnóstico , Nó Sinoatrial/anormalidades , Adulto , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/inervação , Angiografia por Tomografia Computadorizada , Tosse/etiologia , Diagnóstico Diferencial , Feminino , Humanos , Nó Sinoatrial/diagnóstico por imagem , Nó Sinoatrial/cirurgia , Taquicardia Sinusal/diagnóstico
20.
Pacing Clin Electrophysiol ; 42(7): 942-950, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31157407

RESUMO

BACKGROUND: Multipolar phased pulmonary vein ablation catheter (PVAC), specifically its second-generation (PVAC-Gold), has been associated with reduced procedural time for atrial fibrillation (AF) ablation compared to traditional catheters. We performed this study to compare the efficacy of PVAC with point-by-point radiofrequency (RF) ablation. METHODS: This is a multicenter-cohort study (2012-2017), involving patients with symptomatic, paroxysmal AF refractory to at least one antiarrhythmic medication. Overall, 230 patients were enrolled to (A) PVAC and (B) control groups. Subanalyses were done for ablations performed with PVAC-Gold, and for ablations performed without left atrial (LA) ablation in addition to pulmonary vein isolation. Electrocardiogram and 48-h Holter monitoring were used to assess patients at 3, 6, 9, and 12 months postablation. Recurrence was defined as any atrial arrhythmia >30 s excluding an initial 3-month blanking period. RESULTS: Freedom from any atrial arrhythmia at 12 months postablation was 35.70% and 52.80% in groups A and B, respectively (P = .01). Freedom from atrial arrhythmia was not significantly different when limiting the PVAC cohort to PVAC-Gold and excluding patients with additional LA ablation (A: 44.30%; B: 44.30%, P = .80). Procedural and ablation time was significantly lower in group A than B. Multivariate regression model showed female gender (odds ratio [OR] = 2.90) and recurrence during blanking period (OR = 6.60) as significant predictors of recurrence. CONCLUSION: This study suggests that PVAC may achieve less freedom from AF than point-by-point RF; however, efficacy is similar when comparing PVAC-Gold and point-by-point stand-alone PV isolation. PVAC is associated with significantly reduced procedural times for AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA