Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Struct Heart ; 7(5): 100180, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37745677

RESUMO

Background: Despite the demonstrated benefits of transcatheter aortic valve replacement (TAVR), subclinical leaflet thrombosis and hypoattenuated leaflet thickening are commonly seen as initial indications of decreased valve durability and augmented risk of transient ischemic attack. Methods: We developed a multiscale patient-specific computational framework to quantify metrics of global circulatory function, metrics of global cardiac function, and local cardiac fluid dynamics of the aortic root and coronary arteries. Results: Based on our findings, TAVR might be associated with a high risk of blood stagnation in the neo-sinus region due to the lack of sufficient blood flow washout during the diastole phase (e.g., maximum blood stasis volume increased by 13, 8, and 2.7 fold in the left coronary cusp, right coronary cusp, and noncoronary cusp, respectively [N = 26]). Moreover, in some patients, TAVR might not be associated with left ventricle load relief (e.g., left ventricle load reduced only by 1.2 % [N = 26]) and diastolic coronary flow improvement (e.g., maximum coronary flow reduced by 4.94%, 15.05%, and 23.59% in the left anterior descending, left circumflex coronary artery, and right coronary artery, respectively, [N = 26]). Conclusions: The transvalvular pressure gradient amelioration after TAVR might not translate into adequate sinus blood washout, optimal coronary flow, and reduced cardiac stress. Noninvasive personalized computational modeling can facilitate the determination of the most effective revascularization strategy pre-TAVR and monitor leaflet thrombosis and coronary plaque progression post-TAVR.

2.
Sci Rep ; 13(1): 8948, 2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37268642

RESUMO

In recent years, transcatheter aortic valve replacement (TAVR) has become the leading method for treating aortic stenosis. While the procedure has improved dramatically in the past decade, there are still uncertainties about the impact of TAVR on coronary blood flow. Recent research has indicated that negative coronary events after TAVR may be partially driven by impaired coronary blood flow dynamics. Furthermore, the current technologies to rapidly obtain non-invasive coronary blood flow data are relatively limited. Herein, we present a lumped parameter computational model to simulate coronary blood flow in the main arteries as well as a series of cardiovascular hemodynamic metrics. The model was designed to only use a few inputs parameters from echocardiography, computed tomography and a sphygmomanometer. The novel computational model was then validated and applied to 19 patients undergoing TAVR to examine the impact of the procedure on coronary blood flow in the left anterior descending (LAD) artery, left circumflex (LCX) artery and right coronary artery (RCA) and various global hemodynamics metrics. Based on our findings, the changes in coronary blood flow after TAVR varied and were subject specific (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). Additionally, valvular pressure gradient, left ventricle (LV) workload and maximum LV pressure decreased by 61.5%, 4.5% and 13.0% respectively, while mean arterial pressure and cardiac output increased by 6.9% and 9.9% after TAVR. By applying this proof-of-concept computational model, a series of hemodynamic metrics were generated non-invasively which can help to better understand the individual relationships between TAVR and mean and peak coronary flow rates. In the future, tools such as these may play a vital role by providing clinicians with rapid insight into various cardiac and coronary metrics, rendering the planning for TAVR and other cardiovascular procedures more personalized.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
4.
Sci Rep ; 13(1): 8033, 2023 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-37198194

RESUMO

Given the associated risks with transcatheter aortic valve replacement (TAVR), it is crucial to determine how the implant will affect the valve dynamics and cardiac function, and if TAVR will improve or worsen the outcome of the patient. Effective treatment strategies, indeed, rely heavily on the complete understanding of the valve dynamics. We developed an innovative Doppler-exclusive non-invasive computational framework that can function as a diagnostic tool to assess valve dynamics in patients with aortic stenosis in both pre- and post-TAVR status. Clinical Doppler pressure was reduced by TAVR (52.2 ± 20.4 vs. 17.3 ± 13.8 [mmHg], p < 0.001), but it was not always accompanied by improvements in valve dynamics and left ventricle (LV) hemodynamics metrics. TAVR had no effect on LV workload in 4 patients, and LV workload post-TAVR significantly rose in 4 other patients. Despite the group level improvements in maximum LV pressure (166.4 ± 32.2 vs 131.4 ± 16.9 [mmHg], p < 0.05), only 5 of the 12 patients (41%) had a decrease in LV pressure. Moreover, TAVR did not always improve valve dynamics. TAVR did not necessarily result in a decrease (in 9 out of 12 patients investigated in this study) in major principal stress on the aortic valve leaflets which is one of the main contributors in valve degeneration and, consequently, failure of heart valves. Diastolic stresses increased significantly post-TAVR (34%, 109% and 81%, p < 0.001) for each left, right and non-coronary leaflets respectively. Moreover, we quantified the stiffness and material properties of aortic valve leaflets which correspond with the reduced calcified region average stiffness among leaflets (66%, 74% and 62%; p < 0.001; N = 12). Valve dynamics post-intervention should be quantified and monitored to ensure the improvement of patient conditions and prevent any further complications. Improper evaluation of biomechanical valve features pre-intervention as well as post-intervention may result in harmful effects post-TAVR in patients including paravalvular leaks, valve degeneration, failure of TAVR and heart failure.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Hemodinâmica
5.
J Am Heart Assoc ; 12(11): e029310, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37232234

RESUMO

Background Despite the proven benefits of transcatheter aortic valve replacement (TAVR) and its recent expansion toward the whole risk spectrum, coronary artery disease is present in more than half of the candidates for TAVR. Many previous studies do not focus on the longer-term impact of TAVR on coronary arteries, and hemodynamic changes to the circulatory system in response to the anatomical changes caused by TAVR are not fully understood. Methods and Results We developed a multiscale patient-specific computational framework to examine the effect of TAVR on coronary and cardiac hemodynamics noninvasively. Based on our findings, TAVR might have an adverse impact on coronary hemodynamics due to the lack of sufficient coronary blood flow during diastole phase (eg, maximum coronary flow rate reduced by 8.98%, 16.83%, and 22.73% in the left anterior descending, left circumflex coronary artery, and right coronary artery, respectively [N=31]). Moreover, TAVR may increase the left ventricle workload (eg, left ventricle workload increased by 2.52% [N=31]) and decrease the coronary wall shear stress (eg, maximum time averaged wall shear stress reduced by 9.47%, 7.75%, 6.94%, 8.07%, and 6.28% for bifurcation, left main coronary artery, left anterior descending, left circumflex coronary artery, and right coronary artery branches, respectively). Conclusions The transvalvular pressure gradient relief after TAVR might not result in coronary flow improvement and reduced cardiac load. Optimal revascularization strategy pre-TAVR and progression of coronary artery disease after TAVR could be determined by noninvasive personalized computational modeling.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Resultado do Tratamento , Hemodinâmica , Fatores de Risco
6.
Med Image Anal ; 87: 102795, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37060702

RESUMO

Aortic stenosis (AS) is an acute and chronic cardiovascular disease and If left untreated, 50% of these patients will die within two years of developing symptoms. AS is characterized as the stiffening of the aortic valve leaflets which restricts their motion and prevents the proper opening under transvalvular pressure. Assessments of the valve dynamics, if available, would provide valuable information about the patient's state of cardiac deterioration as well as heart recovery and can have incredible impacts on patient care, planning interventions and making critical clinical decisions with life-threatening risks. Despite remarkable advancements in medical imaging, there are no clinical tools available to quantify valve dynamics invasively or noninvasively. In this study, we developed a highly innovative ultrasound-based non-invasive computational framework that can function as a diagnostic tool to assess valve dynamics (e.g. transient 3-D distribution of stress and displacement, 3-D deformed shape of leaflets, geometric orifice area and angular positions of leaflets) for patients with AS at no risk to the patients. Such a diagnostic tool considers the local valve dynamics and the global circulatory system to provide a platform for testing the intervention scenarios and evaluating their effects. We used clinical data of 12 patients with AS not only to validate the proposed framework but also to demonstrate its diagnostic abilities by providing novel analyses and interpretations of clinical data in both pre and post intervention states. We used transthoracic echocardiogram (TTE) data for the developments and transesophageal echocardiography (TEE) data for validation.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Ecocardiografia Transesofagiana
7.
Sci Rep ; 12(1): 21357, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36494362

RESUMO

Transcatheter aortic valve replacement (TAVR) is a frequently used minimally invasive intervention for patient with aortic stenosis across a broad risk spectrum. While coronary artery disease (CAD) is present in approximately half of TAVR candidates, correlation of post-TAVR complications such as paravalvular leakage (PVL) or misalignment with CAD are not fully understood. For this purpose, we developed a multiscale computational framework based on a patient-specific lumped-parameter algorithm and a 3-D strongly-coupled fluid-structure interaction model to quantify metrics of global circulatory function, metrics of global cardiac function and local cardiac fluid dynamics in 6 patients. Based on our findings, PVL limits the benefits of TAVR and restricts coronary perfusion due to the lack of sufficient coronary blood flow during diastole phase (e.g., maximum coronary flow rate reduced by 21.73%, 21.43% and 21.43% in the left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)). Moreover, PVL may increase the LV load (e.g., LV load increased by 17.57% (N = 6)) and decrease the coronary wall shear stress (e.g., maximum wall shear stress reduced by 20.62%, 21.92%, 22.28% and 25.66% in the left main coronary artery (LMCA), left anterior descending (LAD), left circumflex (LCX) and right coronary artery (RCA) respectively (N = 6)), which could promote atherosclerosis development through loss of the physiological flow-oriented alignment of endothelial cells. This study demonstrated that a rigorously developed personalized image-based computational framework can provide vital insights into underlying mechanics of TAVR and CAD interactions and assist in treatment planning and patient risk stratification in patients.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/etiologia , Prognóstico , Células Endoteliais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hemodinâmica , Vasos Coronários , Resultado do Tratamento
8.
Sci Rep ; 12(1): 9718, 2022 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-35690596

RESUMO

Accurate hemodynamic analysis is not only crucial for successful diagnosis of coarctation of the aorta (COA), but intervention decisions also rely on the hemodynamics assessment in both pre and post intervention states to minimize patient risks. Despite ongoing advances in surgical techniques for COA treatments, the impacts of extra-anatomic bypass grafting, a surgical technique to treat COA, on the aorta are not always benign. Our objective was to investigate the impact of bypass grafting on aortic hemodynamics. We investigated the impact of bypass grafting on aortic hemodynamics using a patient-specific computational-mechanics framework in three patients with COA who underwent bypass grafting. Our results describe that bypass grafting improved some hemodynamic metrics while worsened the others: (1) Doppler pressure gradient improved (decreased) in all patients; (2) Bypass graft did not reduce the flow rate substantially through the COA; (3) Systemic arterial compliance increased in patients #1 and 3 and didn't change (improve) in patient 3; (4) Hypertension got worse in all patients; (5) The flow velocity magnitude improved (reduced) in patient 2 and 3 but did not improve significantly in patient 1; (6) There were elevated velocity magnitude, persistence of vortical flow structure, elevated turbulence characteristics, and elevated wall shear stress at the bypass graft junctions in all patients. We concluded that bypass graft may lead to pseudoaneurysm formation and potential aortic rupture as well as intimal hyperplasia due to the persistent abnormal and irregular aortic hemodynamics in some patients. Moreover, post-intervention, exposures of endothelial cells to high shear stress may lead to arterial remodeling, aneurysm, and rupture.


Assuntos
Coartação Aórtica , Humanos , Aorta/diagnóstico por imagem , Aorta/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Células Endoteliais , Hemodinâmica , Hidrodinâmica
9.
J Am Heart Assoc ; 11(2): e022664, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35023351

RESUMO

Background Despite ongoing advances in surgical techniques for coarctation of the aorta (COA) repair, the long-term results are not always benign. Associated mixed valvular diseases (various combinations of aortic and mitral valvular pathologies) are responsible for considerable postoperative morbidity and mortality. We investigated the impact of COA and mixed valvular diseases on hemodynamics. Methods and Results We developed a patient-specific computational framework. Our results demonstrate that mixed valvular diseases interact with COA fluid dynamics and contribute to speed up the progression of the disease by amplifying the irregular flow patterns downstream of COA (local) and exacerbating the left ventricular function (global) (N=26). Velocity downstream of COA with aortic regurgitation alone was increased, and the situation got worse when COA and aortic regurgitation coexisted with mitral regurgitation (COA with normal valves: 5.27 m/s, COA with only aortic regurgitation: 8.8 m/s, COA with aortic and mitral regurgitation: 9.36 m/s; patient 2). Workload in these patients was increased because of the presence of aortic stenosis alone, aortic regurgitation alone, mitral regurgitation alone, and when they coexisted (COA with normal valves: 1.0617 J; COA with only aortic stenosis: 1.225 J; COA with only aortic regurgitation: 1.6512 J; COA with only mitral regurgitation: 1.3599 J; patient 1). Conclusions Not only the severity of COA, but also the presence and the severity of mixed valvular disease should be considered in the evaluation of risks in patients. The results suggest that more aggressive surgical approaches may be required, because regularly chosen current surgical techniques may not be optimal for such patients.


Assuntos
Coartação Aórtica , Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Humanos , Coartação Aórtica/complicações , Coartação Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Morbidade
10.
Front Bioeng Biotechnol ; 9: 643453, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34307316

RESUMO

Due to the high individual differences in the anatomy and pathophysiology of patients, planning individualized treatment requires patient-specific diagnosis. Indeed, hemodynamic quantification can be immensely valuable for accurate diagnosis, however, we still lack precise diagnostic methods for numerous cardiovascular diseases including complex (and mixed) valvular, vascular, and ventricular interactions (C3VI) which is a complicated situation made even more challenging in the face of other cardiovascular pathologies. Transcatheter aortic valve replacement (TAVR) is a new less invasive intervention and is a growing alternative for patients with aortic stenosis. In a recent paper, we developed a non-invasive and Doppler-based diagnostic and monitoring computational mechanics framework for C3VI, called C3VI-DE that uses input parameters measured reliably using Doppler echocardiography. In the present work, we have developed another computational-mechanics framework for C3VI (called C3VI-CT). C3VI-CT uses the same lumped-parameter model core as C3VI-DE but its input parameters are measured using computed tomography and a sphygmomanometer. Both frameworks can quantify: (1) global hemodynamics (metrics of cardiac function); (2) local hemodynamics (metrics of circulatory function). We compared accuracy of the results obtained using C3VI-DE and C3VI-CT against catheterization data (gold standard) using a C3VI dataset (N = 49) for patients with C3VI who undergo TAVR in both pre and post-TAVR with a high variability. Because of the dataset variability and the broad range of diseases that it covers, it enables determining which framework can yield the most accurate results. In contrast with C3VI-CT, C3VI-DE tracks both the cardiac and vascular status and is in great agreement with cardiac catheter data.

11.
Sci Rep ; 11(1): 10888, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34035325

RESUMO

One of the most common acute and chronic cardiovascular disease conditions is aortic stenosis, a disease in which the aortic valve is damaged and can no longer function properly. Moreover, aortic stenosis commonly exists in combination with other conditions causing so many patients suffer from the most general and fundamentally challenging condition: complex valvular, ventricular and vascular disease (C3VD). Transcatheter aortic valve replacement (TAVR) is a new less invasive intervention and is a growing alternative for patients with aortic stenosis. Although blood flow quantification is critical for accurate and early diagnosis of C3VD in both pre and post-TAVR, proper diagnostic methods are still lacking because the fluid-dynamics methods that can be used as engines of new diagnostic tools are not well developed yet. Despite remarkable advances in medical imaging, imaging on its own is not enough to quantify the blood flow effectively. Moreover, understanding of C3VD in both pre and post-TAVR and its progression has been hindered by the absence of a proper non-invasive tool for the assessment of the cardiovascular function. To enable the development of new non-invasive diagnostic methods, we developed an innovative image-based patient-specific computational fluid dynamics framework for patients with C3VD who undergo TAVR to quantify metrics of: (1) global circulatory function; (2) global cardiac function as well as (3) local cardiac fluid dynamics. This framework is based on an innovative non-invasive Doppler-based patient-specific lumped-parameter algorithm and a 3-D strongly-coupled fluid-solid interaction. We validated the framework against clinical cardiac catheterization and Doppler echocardiographic measurements and demonstrated its diagnostic utility by providing novel analyses and interpretations of clinical data in eleven C3VD patients in pre and post-TAVR status. Our findings position this framework as a promising new non-invasive diagnostic tool that can provide blood flow metrics while posing no risk to the patient. The diagnostic information, that the framework can provide, is vitally needed to improve clinical outcomes, to assess patient risk and to plan treatment.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/fisiopatologia , Circulação Sanguínea , Angiografia por Tomografia Computadorizada , Diagnóstico Precoce , Ecocardiografia Doppler , Humanos , Medicina de Precisão , Estudos Retrospectivos , Resultado do Tratamento
12.
Sci Rep ; 10(1): 9048, 2020 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-32493936

RESUMO

Coarctation of the aorta (COA) is a congenital narrowing of the proximal descending aorta. Although accurate and early diagnosis of COA hinges on blood flow quantification, proper diagnostic methods for COA are still lacking because fluid-dynamics methods that can be used for accurate flow quantification are not well developed yet. Most importantly, COA and the heart interact with each other and because the heart resides in a complex vascular network that imposes boundary conditions on its function, accurate diagnosis relies on quantifications of the global hemodynamics (heart-function metrics) as well as the local hemodynamics (detailed information of the blood flow dynamics in COA). In this study, to enable the development of new non-invasive methods that can quantify local and global hemodynamics for COA diagnosis, we developed an innovative fast computational-mechanics and imaging-based framework that uses Lattice Boltzmann method and lumped-parameter modeling that only need routine non-invasive clinical patient data. We used clinical data of patients with COA to validate the proposed framework and to demonstrate its abilities to provide new diagnostic analyses not possible with conventional diagnostic methods. We validated this framework against clinical cardiac catheterization data, calculations using the conventional finite-volume method and clinical Doppler echocardiographic measurements. The diagnostic information, that the framework can provide, is vitally needed to improve clinical outcomes, to assess patient risk and to plan treatment.


Assuntos
Coartação Aórtica/diagnóstico , Coartação Aórtica/terapia , Processamento de Imagem Assistida por Computador/métodos , Aorta/fisiopatologia , Cateterismo Cardíaco , Cardiologia , Simulação por Computador , Ecocardiografia Doppler , Hemodinâmica , Humanos , Hidrodinâmica , Angiografia por Ressonância Magnética/métodos , Modelos Cardiovasculares
13.
J Am Heart Assoc ; 9(5): e015063, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32106747

RESUMO

Background Mixed valvular disease (MVD), mitral regurgitation (MR) from pre-existing disease in conjunction with paravalvular leak (PVL) following transcatheter aortic valve replacement (TAVR), is one of the most important stimuli for left ventricle (LV) dysfunction, associated with cardiac mortality. Despite the prevalence of MVD, the quantitative understanding of the interplay between pre-existing MVD, PVL, LV, and post-TAVR recovery is meager. Methods and Results We quantified the effects of MVD on valvular-ventricular hemodynamics using an image-based patient-specific computational framework in 72 MVD patients. Doppler pressure was reduced by TAVR (mean, 77%; N=72; P<0.05), but it was not always accompanied by improvements in LV workload. TAVR had no effect on LV workload in 22 patients, and LV workload post-TAVR significantly rose in 32 other patients. TAVR reduced LV workload in only 18 patients (25%). PVL significantly alters LV flow and increases shear stress on transcatheter aortic valve leaflets. It interacts with mitral inflow and elevates shear stresses on mitral valve and is one of the main contributors in worsening of MR post-TAVR. MR worsened in 32 patients post-TAVR and did not improve in 18 other patients. Conclusions PVL limits the benefit of TAVR by increasing LV load and worsening of MR and heart failure. Post-TAVR, most MVD patients (75% of N=72; P<0.05) showed no improvements or even worsening of LV workload, whereas the majority of patients with PVL, but without that pre-existing MR condition (60% of N=48; P<0.05), showed improvements in LV workload. MR and its exacerbation by PVL may hinder the success of TAVR.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resistência Vascular/fisiologia , Pressão Ventricular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Ecocardiografia Doppler , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Função Ventricular Esquerda/fisiologia
14.
Minim Invasive Ther Allied Technol ; 27(5): 284-291, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29271289

RESUMO

INTRODUCTION: Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. MATERIAL AND METHODS: In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. RESULTS: Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. CONCLUSION: The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.


Assuntos
Encéfalo/metabolismo , Desenho Assistido por Computador , Fígado/metabolismo , Agulhas , Animais , Bovinos , Géis , Cloreto de Polivinila/química , Impressão Tridimensional , Software
15.
Math Biosci ; 285: 75-80, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28038944

RESUMO

Heart failure is one of the most important issues that has been investigated in recent research studies. Variations that occur in apparatus of mitral valve, such as chordae tendineaea rupture, can affect the valve function during ventricular contraction and lead to regurgitation from the left ventricle into the left atrium. One method for understanding mitral valve function in such conditions is computational analysis. In this paper, we develop a finite element model of mitral valve prolapse, considering the direct effect of left ventricular motion on blood flow interacting with the mitral valve. Ventricular wall motion is used as a constraint for fluid domain. Arbitrary Lagrangian-Eulerian finite element method formulation is used for numerical solution of transient dynamic equations of the fluid domain. Leaflets' stresses and chordal forces during prolapse are determined and compared to previous healthy results, as well as flow characteristics in the computational domain. Results show considerable increases in the stress magnitudes of interior and posterior leaflets in prolapse condition in comparison with previous healthy studies. In addition, chordae tendineae forces are distributed non-uniformly with higher maximum value here, as a result of other chordae tendineae rupture.


Assuntos
Ventrículos do Coração/fisiopatologia , Hemodinâmica/fisiologia , Prolapso da Valva Mitral/fisiopatologia , Modelos Cardiovasculares , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA